Room Air Cleaning System
SUPPLY
MODULE
RETURN
MODULE
BLOWER
MODULE
M13442
APPLICATION
The F120 Room Air Cleaning System is designed to collect
particles by circulating room air through a media filter. When
equipped with an optional CPZ module, the system also
adsorbs gaseous contaminants and odors.
F120
SPECIFICATION DATA
FEATURES
• Specifically designed for use in offices, hospitals,
medical clinics, childcare centers, schools, conference
rooms, copy centers, laboratories, cafeterias, and
hospitality business.
• Ultra-quiet operation allo ws the sy stem to be used in
sound sensitive areas such as conference rooms,
offices, classrooms and libraries.
• Modular design of air supply and return allows
maximum flexibility when planning the appropriate air
recirculation pattern to maximize overall system
performance.
• Special return module filter removes both particulates
and gaseous contaminants from the air stream.
• Convenient roomside service for all filters.
• Easy-to-change prefilter extends the media filter life.
• Blower module can be mounted remotely from the
room to further reduce sound levels.
• Two-speed fan motor allows selecting high or low
airflow speeds.
• Optional exhaust feature allows installations to
maintain the space at a negative pressure with respect
to surrounding areas to prevent contaminants and
odors from moving into nearby areas.
• Installation is ideally suited to rooms with either twoby-four or two-by-two foot drop ceiling panels, but can
be installed in any wall or ceiling that allows ducting
space.
The F120 exhaust feature is used to maintain the space at a
negative pressurization relative to adjacent spaces to prevent
contaminants and odors from moving into nearby areas.
The air supply and return design of the F120 allows air
contaminants to be filtered at the center of the room with the
filtered air returned toward the sides of the room for maximum
room air cleaning.
The Honeywell Trademark is used under license from Honeywell
Intellectual Properties, Inc. by Air-Pure Systems.
Honeywell International Inc. makes no representations or warranties
with respect to this product.
68-3042-2 Revised 11-07
F120 ROOM AIR CLEANING SYSTEM
SPECIFICATIONS
IMPORTANT
The specifications given in this publication do not
include normal manufacturing tolerances. Therefore,
this unit may not exactly match the listed specifica-
—mounting hardware kit consisting of 12 mounting
brackets; 40 ft (12m) of 12-gauge high-tensile strength
wire; six standard T- bar mounts; duct tape;
—seven duct collar straps.
tions. This product is tested and calibrated under
closely controlled conditions, and som e mi no r di ff erences in performance can be expected if those conditions are changed.
Model:
F120
consists of:
—two filtered return modules with a return grille, prefilter,
and
—either a 99.97% HEPA filter or a 95% DOP filter and
CPZ module;
—four air supply modules with supply grilles;
—a blower module with a two-speed blower, four
recirculating air supply openings, four recirculating air
return openings and an optional exhaust opening;
Color:
Blower Housing: Unpainted galvanized steel.
Return and Supply Grilles: Off-white
Electrical Ratings:
120 Vac, 60 Hz 240 Vac, 60 Hz
Fan Speed
II (high) I (low) II (high) I (low)
a
Fan Speed
Current (A) 7.0 5.5 3.5 2.8
Power (W) 800 695 800 695
a
Off is “O”.
a
—75 ft (23m) of six-inch diameter flexible duct; 75 ft (23m)
of eight-inch diameter flexible duct;
Air Flow Capacity:
Model Voltage
Efficiency
Particulates at 0.3
micron (DOP Test)
VOC/Odors
(First Pass Average)
Gas, VOC, Odor
Control Module (2)
Air Vol cfm
(cu m/hr)
Air
Vol cfm
(cu m/hr)
F120A 1023 120 Vac 60 Hz 95% 85% CPZ 900 (1530) 1050 (1780)
F120A 1031 120 Vac 60 Hz 99.97% — — 900 (1530 1000
F120A 1015 120 Vac 60 Hz
a
With exhaust option installed.
b
Purchase filters separately.
bbb
——
(1700)
a
Filters:
HEPA: High efficiency p articulate air (HEPA) filter is 99.97 per-
cent efficient for 0.3 micron particulates when measured
with Military Standard 282 DOP test.
DOP: Hospital-grade DOP filter is 95 percent efficient for 0.3
micron particulates when measured with Military Standard
282 DOP test.
CPZ: Sorbent modules contain 11 pounds of sorbent. Adsorbs
higher molecular weight hydrocarbons and oxidizes acid
gases and lower molecular weight hydrocarbons.
Ambient Temperature Rating:
Shipping and Storage: -20°F to +150°F (-29°C to +66°C).
Operating: Ambient temperatures ≥90°F (32°C).
Can tolerate 104°F (40°C) for brief periods.
Sound Output Rating at 3.3 ft (1m):
High Speed: 52 dBA (below ASHRAE noise criteria (NC)
curve specifications for NC45 over speech recognition frequency range of 500 to 2000 Hz).
Low Speed: 45 dBA (below ASHRAE noise criteria (NC) curve
for NC35 over speech recognition frequency range of 500
to 2000 Hz).
Installation Weight:
Blower Module: 63 lb (28.6 kg).
Supply Module: (4 required): 8 lb (3.6 kg).
Return Module without filter (2 required): 24 lb (10.9 kg).
95% DOP Filter/CPZ Module (2 required): 21 lb (9.5 kg).
99.97% HEPA Filter (2 required): 10 lb (4.5 kg).
Shipping Weight:
F120 with 95% DOP Filter and CPZ Module: 207 lb (94 kg).
F120 with 99.97% HEPA Filter: 182 lb (83 kg).
F120A1015: 152 lb (69 kg).
F120A1007: 70 lb (32 kg).
Dimensions: