PRODUCT SPECIFICATIONS
Range:
DT-500, DT-500T
11 m x 9 m (35' x 30')
Alarm relay:
Energized Form A (NC)
100 mA, 30 VDC
Tamper:
25 mA, 30 VDC
Power requirements:
10 - 14.5 VDC
35 mA, 12 VDC
RFI immunity:
30 V/m
10 MHz - 1000 MHz
PIR white light immunity:
6,500 Lux
Frequencies:
Center band 2.45 GHz
Sensitivity:
2 - 4 steps within field of
view
SUPERVISION
If the microwave technology stops sending or receiving
signals, or the system electronics are not in normal working
order, the sensor's red LED will latch ON and alarm relay will
open.
The sensor can only recover from this state by cycling power.
If the problem still exists after cycling power, the sensor will
fail the power-up self-test, the red LED will latch ON, and
alarm relay will open. Self-test is performed at power-up and
every two hours after that.
NOTE: The sensor should be tested at least once each year
to ensure proper operation.
DT-500 Series DUAL TEC
®
Motion Sensor Supplemental Information
DETECTION PATTERNS
TOP VIEW
Wall Mounted
Wide Angle Lens with Microwave Pattern
SIDE VIEW
Wide Angle Lens
FCC Notice: This equipment has been tested and found to comply with
the limits for a field disturbance sensor, pursuant to Part 15 of the FCC Rules.
The user is cautioned that changes or modifications not expressly approved
by IntelliSense could void the user's authority to operate this equipment.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more
of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
IC Notice: Operation is subject to the following two conditions: (1) this
device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation of
the device.
This device requires a radio licence, unless it is installed totally inside a
building. (User must obtain this licence.)
Une licence est requise pour ces dispositifs, sauf pour ceux installés tout à fait
à l'intérieur d'un bâtiment. (Il faut que l'utilisateur obtienne cette licence.)
All Rights Reserved
Copyright 2001 IntelliSense.
5-051-502-00 Rev H
Operating temperature:
-10° to 49° C (14° to 120° F)
(UL: 0o to 49o C (32o to 120o F))
PIR fields of view (edges):
Standard lens
22 long range
12 intermediate
6 lower
4 down
Dimensions:
13 cm x 7 cm x 4 cm
5" H x 2-7/8" W x 1-5/8" D
Weight:
200 g (7 oz)
Packaged product:
260 g (9 oz)
Approvals/listings:
FCC certified
IC certified
UL listed
ULC Listed*
C-Tick
IMPORTANT: This sensor does not respond to walk-tests
in a conventional manner. Rather, it tracks motion and
analyzes the signals to confirm a valid alarm condition.
Internally the sensor registers, then confirms an alarm condition. To observe this, take 2 to 4 steps into the pattern then
stop and watch the LED.
ANIMAL IMMUNITY
To achieve the highest level of attainable animal immunity,
please use the following recommended mounting guidelines:
Mount the sensor at the standard height of 2.3 m
(7' 6").
Make sure an animal cannot get within 1.9 m (6')
of the sensor, such as by jumping on furniture or
shelving.
Make sure the sensor is level with the wall. Use
a leveling tool and position it vertically across
the face of the sensor. Improper installation can
reduce animal immunity levels.
Make sure the sensor has a clear line-of-sight to all
areas you wish to protect. If the PIR sensor is blocked,
the unit will not alarm.
Aim the sensor toward the interior of the room, point-
ing away from windows, moving machinery, and heat-
ing/cooling sources.
Each installation should be tested to determine the level of
attainable animal immunity, and tested again whenever the
animal configuration changes. The following worksheet
provides additional guidelines for determining the level of
expected immunity:
NOTE: Animal immunity characteristics have not been verified by
Underwriter's Laboratories, Inc.
IMPORTANT: For UL certificated installations, the DT-500 must be connected to a UL listed power supply or UL listed control unit capable of
providing a minimum of four hours of standby power.
*NOTE: The ULC label or listed marking on a product is the only evidence
provided by Underwriters Laboratories of Canada to identify products that
have been produced under the Listing and Follow-up Service.
This Class B digital apparatus meets all requirements of the Canadian
Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe B respecte toutes les exigences du
Règlement sur le matériel brouilleur du Canada.
SUPERVISION
If the microwave technology stops sending or receiving
signals, or the system electronics are not in normal working
order, the sensor's red LED will latch ON and alarm relay will
open.
The sensor can only recover from this state by cycling power.
If the problem still exists after cycling power, the sensor will
fail the power-up self-test, the red LED will latch ON, and
alarm relay will open. Self-test is performed at power-up and
every two hours after that.
NOTE: The sensor should be tested at least once each year
to ensure proper operation.
ANIMAL IMMUNITY WORKSHEET
Total combined animal weight(s) 45 kg (100 lb.)
Flooring Material: Flooring materials within the sensors fieldof-view will effect the levels of animal immunity. Generally, a
carpeted floor will achieve a higher level of immunity than a
cement floor.
Carpet: deduct 0
Wood: deduct 2.25 kg (5 lb.)
Tile/Cement: deduct 4.5 kg (10 lb.) ___________
Animal Heat Radiation*: Generally, the longer the hair on
an animal, the less heat or infrared energy they radiate. A
long hair animal tends to achieve a higher level of animal
immunity than a short hair animal.
Long Hair: deduct 0
Medium Hair: deduct 2.25 kg (5 lb.)
Short Hair: deduct 4.5 kg (10 lb.) ___________
Estimated animal immunity level =
___________
*Use in installations with dogs and cats.