Honeywell DR4500A Data Sheet

Document 49003, p. 1 of 6
Copyright © 2002 all rights reserved
800-323-4340 www.coleparmer.com
International fax: 847-549-1700 In Canada, call Labcor at 800-363-5900
In the UK, call Cole Parmer Instrument Co. Ltd. at 0500 345 300
warranty
2
year
Honeywell®DR4500A 12" Digital Recorder
Customize your own system
with optional features and advanced functions
Identify the specific recorder and options you would like to order from each option table. Complete the Key Numbers Form to determine your custom order number by using the “Key No.” in each of the five tables on the following pages. Then call our Customer Contact Department to place your order.
Note: Tables 1, 2, and 4 use a composite of option key numbers. A complete order number must have the specified number of digits filled in. There are restrictions to options based on other selections. Please see the “notes” section when indicated for further information.
Creates and prints the chart as data is recorded
User configurable—set parameters to meet your needs
ITEM No.
EXTERNAL
EXTERNAL
SOFTWARE
OPTIONS
OUTPUTS
INTERFACE
OPTIONS
& PEN
TABLE
TABLE 1
TABLE 2
TABLE 3
TABLE 4
6 digits — 4 digits 2 digits 3 digits 1 digit 7 digits
DR45AT — { _ _ _ _ } — { _ _ } { _ _ _ } { _ } { _ _ _ _ _ _ 0}
KEY NUMBERS FORM
Honeywell—Reg TM Honeywell Inc
How To Develop Your Custom Order Number
Copyright © 2002 all rights reserved
800-323-4340 www.coleparmer.com
International fax: 847-549-1700 In Canada, call Labcor at 800-363-5900
In the UK, call Cole Parmer Instrument Co. Ltd. at 0500 345 300
Document 49003, p. 2 of 6
C-P Catalog no. Description ITEM No.
EX-80663-00 Digital Circular Recorder, 1 Channel DR45AT-1000 EX-80663-10 Digital Circular Recorder, 2 Channel DR45AT-1100 EX-80663-20 Digital Circular Recorder, 3 Channel DR45AT-1110 EX-80663-30 Digital Circular Recorder, 4 Channel DR45AT-1111
ITEM NUMBER TABLE
Option Tables
Custom Order Number Example DR45AT–1100–44–000–H–00NK00–0:
To determine a custom order number, refer to the applicable table per each bullet listing
For further details, or for help in specifying a
custom recorder application, contact our
Application Specialists at (800) 323-4340.
More Information
Item Table
“EX-80663-10, Two Channel Recorder ".
Choose key number DR45AT–1100
Table 1: External Outputs
“Control Output 1 - Setpoint programming".
Choose key number 4 _ “Control Output 2 - Setpoint programming". Choose key number 4 _ . Completes key number 44.
Table 2: External Interface and Pen Selection
“Output - None”. Choose key number 0 _ _
“Pen - Truline High Speed”.
Choose key number _ 0 _
“Inputs - None". Choose key number _ _ 0 Combined key number 000.
Table 3: Software Options
"Math". Choose key number H
Table 4: Options
“Door - Gray with glass window". Choose key number 0 _ _ _ _ _ _ "Door Accessories - Standard latch". Choose key number _ 0 _ _ _ _ _ "Chart Accessories - Chart illumination". Choose key number _ _ N _ _ _ _ "Approval/Certificate - CE mark". Choose key number _ _ _ K _ _ _ "Customization - None". Choose key number _ _ _ _ 000 Combined key number 00NK000
Final Order Number:
DR45AT - 1100 - 44 - 000 - H - 00NK000
Copyright © 2002 all rights reserved
800-323-4340 www.coleparmer.com
International fax: 847-549-1700 In Canada, call Labcor at 800-363-5900
In the UK, call Cole Parmer Instrument Co. Ltd. at 0500 345 300
Document 49003, p. 3 of 6
DR45AT Item
Key No.
Option Description
1000 1100 1110 1111
Auxiliary 4-20 mA ◗◗◗◗ 1 _ _ RS485 MODBUS® RTU Communications ◗◗◗◗ 3 _ _
Output
RS485 MODBUS® RTU Communications +
◗◗◗◗ 4 _ _
Auxiliary 4-20 mA None ◗◗◗◗ 0 _ _ Truline High Speed Pen ◗◗◗◗ _ 0 _
Pen
Abrasion resistant pen (see Note 4) ◗◗◗◗ _ 1 _ 2 alarms / 2 digital inputs ◗◗◗◗ _ _ 1
Inputs 1 alarm / 1 timer / 2 digital inputs ◗◗◗◗ _ _ 4
None ◗◗◗◗ _ _ 0
Note 4: This option is only available with chart rotations of 24 or 744 hours.
EXTERNAL INTERFACE AND PEN SELECTION - TABLE 2
Communications option—Provides RS-485 serial communication for configuration and monitoring of your process
Digital inputs—Provides two digital inputs which act as remote switches. When contact is closed, recorder can be set to go to a setpoint, switch to manual mode, begin or hold execution of the setpoint ramp or program, or reset the totalizer.
Use a composite of options for a 3-digit key number for this table. (See example on page 1)
DR45AT Item
Key No.
Option Description
1000 1100 1110 1111
Control
Setpoint programming ◗◗◗◗ 4 _
Output 1
FM approval (see Note 1) ◗◗◗◗ 6 _ None ◗◗◗◗ 0 _
Control
Setpoint programming (see Note 2) ◗◗◗◗ _ 4
Output 2
FM approval (see Note 3) ◗◗◗◗ _ 6 None ◗◗◗◗ _ 0
Note 1: This option is only available with 4-20 mA control output. Note 2: This option is only available with Control Output 1 - Setpoint programming. This option is not available with key numbers DR45AT - 1000. Note 3: This option is only available with Control Output 1 - FM approval and with 4-20 mA control output. This option is not available with key numbers DR45AT - 1000.
EXTERNAL OUTPUTS - TABLE 1
Setpoint programming—Single-setpoint ramp: configure to ramp over a time interval of 1 to 255 minutes. Setpoint program: configure up to 12 ramp/soak segments
All control outputs come standard with Accutune II tuning capability. Use a composite of options for a 2-digit key number for this table. (See example on page 1 )
MODBUS—Reg TM of Schneider Automation, Inc.
Copyright © 2002 all rights reserved
800-323-4340 www.coleparmer.com
International fax: 847-549-1700 In Canada, call Labcor at 800-363-5900
In the UK, call Cole Parmer Instrument Co. Ltd. at 0500 345 300
Document 49003, p. 4 of 6
DR45AT Item
Key No.
Option Description
1000 1100 1110 1111
Totalization ◗◗◗◗ A
Input 1 Totalization + math ◗◗◗◗ K
Math (see Note 5) ◗◗◗◗ B Totalization ◗◗◗◗ E
Inputs 1 & 2
Totalization + math ◗◗◗◗ L None ◗◗◗◗ 0
Note 5: Math includes Summer, Multiple Divider with Square Root, Multiplier with Square Root, Multiplier Divider, Multiplier, Subtractor Multiplier, HiLo Select, and Polynominal Equation.
SOFTWARE OPTIONS - TABLE 3
Totalizer function—Totalize a variable, such as a flow signal, on one or two channels. Displays an 8-digit indication of totalized value; includes reset capability.
Math function algorithms—Pre-configured algorithms include summer, multiplier/divider, multiplier, and subtractor/multiplier.
Copyright © 2002 all rights reserved
800-323-4340 www.coleparmer.com
International fax: 847-549-1700 In Canada, call Labcor at 800-363-5900
In the UK, call Cole Parmer Instrument Co. Ltd. at 0500 345 300
Document 49003, p. 5 of 6
Note 6: This option is not available with UL, CSA, or FM agency approvals; or TABLE 4 key numbers
_ _ _ L _ _ _, _ _ _ M _ _ _, _ _ _ P _ _ _, _ _ _ R _ _ _, _ _ _ U _ _ _, _ _ _ W _ _ _, _ _ _ N _ _ _, _ _ _ C _ _ _, _ _ _ T _ _ _, or _ _ _ S _ _.
Note 7: This option is not available with TABLE 4 key numbers 2 _ _ _ _ _ _, 3 _ _ _ _ _ _, 4 _ _ _ _ _ _, 7 _ _ _ _ _ _. Note 8: This option is not available with TABLE 4 key numbers 2 _ _ _ _ _ _, 3_ __ _ _ _, 4_ __ _ _ _, 7 _ _ _ _ _ _, A _ _ _ _ _ _, or B _ _ _ _ _ _. Note 9: This option is not available with CE mark option; or TABLE 4 key numbers
_ _ _ K _ _ _, _ _ _ L _ _ _,
_ _ _ M _ _ _, _ _ _ N _ _ _, or _ _ _ W _ _ _.
Item
Key No.
Options Description
DR4301 DR4302 DR4311 DR4312
Gray with glass window ◗◗◗◗0 _ _ _ _ _ _ Gray with acrylic window ◗◗◗◗1 _ _ _ _ _ _ NEMA 4 SST door with glass
◗◗◗◗2 _ _ _ _ _ _
window (see Note 6) NEMA 4 SST door with acrylic
◗◗◗◗3 _ _ _ _ _ _
window (see Note 6)
Door Blue with glass window ◗◗◗◗5 _ _ _ _ _ _
Blue with acrylic window ◗◗◗◗6 _ _ _ _ _ _ Black with glass window ◗◗◗◗8 _ _ _ _ _ _ Black with acrylic window ◗◗◗◗9 _ _ _ _ _ _ Heavy duty SS door with glass window ◗◗◗◗A _ _ _ _ _ _ Heavy duty SS door with acrylic window ◗◗◗◗B_ _ _ _ _ _ Standard latch (see Note 7) ◗◗◗◗_ 0 _ _ _ _ _
Door Accessories Keyed latch ◗◗◗◗_ A _ _ _ _ _
Door lock (see Note 8) ◗◗◗◗_ K _ _ _ _ _ Configuration Lockout/Chart plate seal ◗◗◗◗_ _ L _ _ _ _
Chart
Configuration Lockout/Chart plate seal,
◗◗◗◗_ _ M _ _ _ _
and chart illumination (see Note 9)
Accessories
Chart illumination (see Note 9) ◗◗◗◗_ _ N _ _ _ _ None ◗◗◗◗_ _ 0 _ _ _ _
OPTIONS - TABLE 4 (con't next page)
Physical features—For added protection, the recorders are available with NEMA 4 doors, acrylic windows, and door locks to prevent unauthorized entry.
Instrument Power—Add excitation voltage to your recorder—no need for a separate power supply for your transmitter. The 24 VDC output powers up to two transmitters.
Chart illumination—Illuminates chart area to improve visibility in low-light areas. Use a composite of options for a 7-digit key number for this table.
Copyright © 2002 all rights reserved
800-323-4340 www.coleparmer.com
International fax: 847-549-1700 In Canada, call Labcor at 800-363-5900
In the UK, call Cole Parmer Instrument Co. Ltd. at 0500 345 300
Document 49003, p. 6 of 6
Catalog no. Description Price Replacement thermal pen for digital recorders EX-80663-92 Thermal pen $154.00/ea Replacement thermal paper for recorders EX-80663-90 Pack of 100 sheets 51.25/pk
Note 10: This option is only available with TABLE 1 key numbers 00, 60, and 66; and TABLE 2 key numbers _ _ 0. Note 11: You must supply Input Actuation Type and Range for each input with the order to have unit
custom calibrated.
OPTIONS - TABLE 4 (con’t)
Approvals—Recorders can be UL-listed, CSA-approved, CE-marked, or FM-approved (may be combined). Use a composite of options for a 7-digit key number for this table.
Item
Key No.
Options Description
DR4301 DR4302 DR4311 DR4312
CE Mark ◗◗◗◗_ _ _ K _ _ _ CE mark, plus UL listing ◗◗◗◗_ _ _ L _ _ _ CE mark, plus CSA certification ◗◗◗◗_ _ _ W _ _ _ CE mark, plus FM approval (see Note 10) ◗◗◗◗_ _ _ M _ _ _ CE mark, plus UL listing, FM approval
◗◗◗◗_ _ _ N _ _ _
and CSA certification (see Note 10)
Approval/ UL listing ◗◗◗◗_ _ _ P _ _ _ Certification CSA certification ◗◗◗◗_ _ _ C _ _ _
FM approved – Class 1, Div.2,
◗◗◗◗
_ _ _ R _ _ _
Groups A,B,C,D (see Note 10) UL listing and FM approval (see Note 10)
◗◗◗◗_ _ _ S_ _ _
UL listing and CSA certification ◗◗◗◗_ _ _ T _ _ _ UL listing and CSA certification, plus
◗◗◗◗
_ _ _ U _ _ _
FM approval (see Note 10) None ◗◗◗◗_ _ _ 0 _ _ _
Customer identification tag
◗◗◗◗
_ _ _ _ T 0 0
30 character maximum Certificate of conformance (F3391)
◗◗◗◗_ _ _ _ B 0 0
Custom calibration/ test report (F3399)
◗◗◗◗
_ _ _ _ C 0 0
Customization (see Note 11)
Certificate of conformance identification tag
◗◗◗◗_ _ _ _ D 0 0
Customer calibration and identification tag (see Note 11)
◗◗◗◗_ _ _ _ E 0 0
None
◗◗◗◗_ _ _ _ 0 0 0
Replacement Items