Honeywell ConneXt Loneworker Data sheet

MicroRAE
Wireless 4-Gas Monitor
The MicroRAE four-gas portable detector brings enhanced user-
friendliness and exibility to wireless gas detection. This enables
continuous, instant visibility of safety threats for faster, more informed
decisions, to protect workers, facilities, and the environment, and to
optimize operations.
The MicroRAE is a wireless diffusion detector that simultaneously
monitors up to four gases, including hydrogen sulde, carbon
connectivity options the MicroRAE can deliver real-time instrument
readings and alarm status to other wireless offerings such as ConneXt
Plus, ConneXt Pro, ConneXt Loneworker
KEY FEATURES
• Honeywell ConneXt compatible with Mesh and Wi wireless congurations
• Compact and lightweight
• IP-67 water- and dust-resistant case
• Strong, protective, concussion-proof design
• Real-time gas concentration readings, location, alarm and status enabled by state of-the-art wireless technology
• Unmistakable ve-way local and remote notication of alarm conditions
• Short bump test & calibration time
4
and Safety Communicator.
INDUSTRIES
Personal protection and general safety and compliance in:
• Lone Worker Applications
• Oil and Gas
• Waste water treatment
• Utilities
• Telecommunications
• Fireghting
• Petrochemicals
• Construction
• Man Down Alarm with real-time remote wireless notication
• GPS module for location
• Bluetooth to a Smart Phone device for uplink data communication and device conguration.
• Remote notication & Panic function
• Fully automated bump testing and calibration with AutoRAE 2
®
low energy connection
1
®
• Global approval for worldwide acceptance
• Filtered LEL sensor options to inhibit sensor poisoning
MicroRAE
Wireless 4-Gas Monitor
SPECIFICATIONS
Instrument Specications
Size 4.6" H x 3.0 (2.6)3.0" W x 0.9” D
Weight 7.03 oz (206 g) including Li-ion batter y and clip Sensors
Battery Rechargeable Li-ion
Running time 15 hours continuous non-wireless
Display Graphic Monochrome display
Keypad Two-button operation Direct Readout Real time reading of gas concentration and Man Down indicators
Alarms Multi-tone 100dB buzzer (at 11.8"/ 30 cm, typical), vibration alarm, and
Datalogging Continuous datalogging (6 month for 4 sensors at 1-minute intervals)
Communication & Data Download
Wireless Network RAE Dedicated Wireless Mesh network or Standard WiFi
Wireless Range (Typical)
EMC/RFI EMC directive: 2004/108/EC IP Rating IP-67 Calibration Two-point calibration (manual, or automatic with AutoRAE 2)
117 mm H x 76(66)74 mm W x 24 mm D
LEL Catalytic bead for combustibles Liquid Oxygen (O Electrochemical Sensor for C O, H
11 hours continuous wireless Note: All battery specications at 68° F (20° C); lower temperatures and alarm conditions will affect runtime.
1.73" W x 1.29" H (44 mm x 33 mm) with 2 color back light modes
Multiple units display options Wireless and GPS ON/OFF and reception quality STEL, TWA, peak, and minimum values Intelliash and policy enforcement indicators
ashing LEDs and on-screen indication of alarm conditions Alarms: latching, non latching or manual override Additional diagnostic alarm and display message for low battery Wireless connectivity alarm Man Down Alarm and real-time remote wireless notication
User-congurabel datalogging intervals (from 1 to 3,600 seconds)
Data download and instrument set-up and upgrades on PC via Travel Charger Wireless data and status transmission via built-in RF modem (optional)
Up to 650 ft (200m) for sub1GHz Mesh Radio Up to 330 ft (100m) for WiFi Up to 15 ft (5m) for BLE
)
2
S, HCN
2
3
3
Safety Certications
Temperature -4° to 140° F (-20° to 60° C) for T4 temperature code
Humidity 0% to 95% relative humidity (non-condensing) Attachments Stainless-steel alligator clip: wrist wrap (optional) Warranty 2-year warranty on device and sensors
Wireless ISM license free band. IEEE 802.15.4 Sub 1 GHz
Wireless Approvals FCC Par t15, CE R&TTE, Bluetooth 4.0, GPS, Others
US & Canada: Class I, Division 1, Groups A, B, C and D
II 2G Ex ia d IIC T4 Gb I M1 EX ia I Ma
2
IEEE 802.11 bands b/g 2.4 GHz
4
Default Sensor Specications
Gas Monitor Range Resolution
Oxygen (O2) 0 to 30.0% 0.1%
Combustible 0 to 100% LEL 1% LEL Carbon Monoxide (CO) 0 to 1,000 ppm 0 – 250 ppm / 1 ppm
Hydrogen Sulde (H
Hydrogen Cyanide (HCN) 0 to 50 ppm 0.2 ppm
S) 0 to 100 ppm 0 – 50 ppm / 0.1 ppm
2
250 – 1,000 ppm / 3 ppm
50 – 100 ppm / 1 ppm
ORDERING INFORMATION
• Refer to the Portables Pricing guide for monitor congurations and accessories
OPTIONAL ACCESSORIES
• AutoRAE 2 Automatic Test and Calibration Systems
• Gang Charger (5 units)
• Auxiliary lter
• Hand pump kit
• Truck mount charger
CORPORATE HEADQUARTERS
RAE Systems by Honey well
3775 North First Street San Jose, CA 95134 USA RAE-InsideSales@honeywell.com
DS -1121- 01
WORLDWIDE SALES OFFICES
USA/Canada 1.877.723.2878 Europe +800.333.222.44 /+41.44.943.4380 Middle East +971.4.450.5852 China +86.10.5885.8788-3000 Asia Pacic +852.2669.0828
1
Additional equipment and/or software licenses may be required to enable remote
wireless monitoring and alarm transmission
2
Against factory defects
3
Receiving > 80%
4
Contact RAE Systems for country specic wireless approvals and certicates.
Specications are subject to change