Honeywell 7845GSMR User Manual

Page 1
Honeywell is focused on providing the future of alarm communication solutions for the security industry. Alternative communication methods are critical in the marketplace due to VoIP, migration from POTS and global growth of digital networks.
Honeywell’s Digital Cellular Communicators deliver secure, reliable and complementary digital communications via the GSM (Global System for Mobile) network. Our use of Dual-Path GPRS service with SMS backup provides substantial benefits to protect your investment by future-proofing your recurring revenue.
This groundbreaking communications solution offers full data reporting and uploading/downloading with most Honeywell control panels. In addition, with on-board zone inputs and optional dialer capture capability, we’re compatible with other manufacturers’ security panels as well.
The addition of the snap-in GSML and VISTA-GSM lines allow for integration of the GSM modules directly into the Honeywell VISTA-21iP and LYNX control panels – making installation faster and easier.
All signals are delivered to Honeywell’s AlarmNet Network Control Center, which routes the information to the appropriate central station. The state of the art AlarmNet Network Control Center is fully redundant and monitored 24/7. AlarmNet has the ability to route messages using AlarmNet-i and 800 PLUS services, providing true redundancy and multi-path message delivery.
• Full Contact ID or ADEMCO High-Speed Reporting
Contact ID reporting using ECP mode with compatible Honeywell control panels or combined with dialer capture for non-ECP capable control panels.
• 256-bit AES Encryption
Advanced encryption standard used for secure communications.
• Dual-Path Technology
Uses GPRS (General Packet Radio Service) as primary digital cellular path and automatically switches to SMS (Short Message Service) if GPRS is unavailable.
• Upload/Download
With select Honeywell control panels using GPRS. Requires Compass version 1.5.8.54a or higher.
• Dynamic Signaling with Certain Honeywell Control Panels
Provides management of control panel dialer and digital cellular communicator. Programmable priority and delays determine signal path.
• Diagnostic LEDs
Provide signal strength and status indications.
• QOS
Quality of Service diagnostics via AlarmNet supply vital information including when a message was received, battery voltage, input voltage, signal strength and message path.
• Web-Based Programming
Allows complete interactive programming from AlarmNet Direct. https://services.alarmnet.com/Alarmn etDirect
• Intelligent Supervision
Any message generated serves as a supervision message per optional 24 hour or 30 day intervals. This feature effectively limits required messages to be sent.
• Remote Services Capability*
Optional Total Connect value-added web-based or SMS system control as well as e-mail notification of system events.
*Service subscription required.
FEATURES
Features that apply to all four products
SERVICE
G
GSM Communicators
GSMCF
7845GSMR
GSML VISTA-GSM
Page 2
FEATURES
GSM Communicators
• Universal Control Panel Compatibility
Flexible modes of operation allow ECP alarm reporting by Honeywell control panels, 4204 relay mode for Honeywell controls (that do not support ECP alarm reporting) and zone triggering for use with other control panels.
• Dialer Capture Ready
Compatible with Dialer Capture Intelligence Device DCID (for LYNX) or
DCID-EXT (other control panels). Captures Contact ID messages from the panel’s phone line and sends them to the central station via the GSM radio.
• Six Input Zones
Digital processing for improved detection and false alarm protection
• Tamper Protected Enclosure
Built-in tamper sends a report when a tamper condition is detected and a restore when cleared.
• Built-in Power Supply
On board charging circuit design accommodates back-up battery. Includes primary power and battery supervision.
• Back-Up Battery
6V 3.1Ah supplied to deliver up to 24 hours of standby operation.
Features that apply to the 7845GSMR and GSMCF only
• No Power Supply Required
Fully powered (primary and backup battery) from the control panel.
• Integration
Snap-in module allows for quick and easy installation of the GSM module directly into the LYNX (GSML) and VISTA panels (VISTA-GSM).
Features that apply to the VISTA-GSM and GSML only
SPECIFICATIONS
GSML
Physical
• Dimensions: 5.625" x 2.25"
Electrical
• Input Voltage: 12VDC
(powered by the LYNXR-I Series/ReadyGuard-RI Series Control) (Range: 5.5 VDC-12 VDC)
• Quiescent Current: 40mA
• Peak Current During Transmit:
650mA
GSML Antenna
• Type: Dual band, dipole, with flying lead coax
• PCB VSWR: <2:1
• Bands: 824-896 MHz,
1850-1990 MHz
• Impedance: 50 ohms
• Polarization: Vertical
• Dimensions: 20mm x 125mm
• Gain (Peak): 0 dBi
• Cable: 60mm of 1.37mm lead coax
• Connector Type: MMCX Male
VISTA-GSM
Physical
• Dimensions: 2.2" x 4.0"
Electrical
• Input Voltage 4.1V
• Peak Current During Transmit:
1.6A
• Quiescent Current: 20mA
VISTA-GSM Antenna
• Type: Dual band, dipole
• VSWR: <2:1
• Bands: 824-896 MHz, 1850-1990 MHz
• Impedance: 50 ohms
• Polarization: Vertical
• Dimensions: 161mm x 26mm
• Gain (Peak): 0-4 dBi
• Connector Type: SMA male
2
Page 3
SPECIFICATIONS
GSM Communicators
Power
Input Operating Voltages:
– 10.5–14.3VDC or 9–16.5VAC
Backup Battery:
– 6V 3.1A (24 hours standby)
Current Requirements:
– 50mA standby – 1A peak transmit
Transmission Power:
– 850 MHz 1 Watt to 1900 MHz 2 Watts
Mechanical
Dimensions:
– 8" H x 7.5" W x 1.86" D
Operating Temperature:
– -20° to 55° C (-4° to 131° F) can go to 70° C (158° F) but
will not be in spec for GSM network requirements
Humidity:
– 0% – 90% non-condensing
7845GSMR/GSMCF
3
Canadian Communications Agency Listings
U.S. Communications Agency Listings
Page 4
Applicable to all four products Applicable to the 7845GSMR and GSMCF only
7720P Programmer
K14139 Battery
(Included)
1332
Transformer
(1332CN for
Canada)
(Included)
DCID
Dialer Capture
Intelligence Device
(For Non-ECP LYNX controls)
DCID-EXT
Dialer Capture
Intelligence Device
(For Non-ECP capable
control panels)
ACCESSORIES
GSM Communicators
ORDERING
7845GSMR Digital Cellular Communicator with Remote Services Capability
GSMCN Digital Cellular Communicator for Canada with Remote Services Capability
7845GSMRG California Compliant Digital Cellular Communicator with Remote Services Capability
GSMCF Commercial Fire Communication Kit includes: 7845GSMR, Commercial Red Cabinet,
3 dB Antenna Kit
GSML Internal GSM Module for LYNX
GSMLCN Internal GSM Module for LYNX (Canada)
VISTA-GSM Plug-in GSM Module for VISTA-21iP
L/7845GSMR/D February 2009 © 2009 Honeywell International Inc.
Automation and Control Solutions
Honeywell Security & Communications 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747
www.honeywell.com
Loading...