Honeywell 72838 User Manual

Non-programmable Thermostat
Thermostat non programmable
Termostato no programable
72838 TH401
Owner’s Guide
Guide du propriétaire
Guía del usuario
400-401-001-A
Need Help?
We are here to help. Call 1-800-468-1502.
Besoin d’aide?
Nous sommes là. Composez le 1 800-468-1502.
¿Asistencia?
Estamos aquí para ayudarlo. Llame al 1 800-468-1502.
72838 / TH401
Table of contents
About your new thermostat ............................................................................ 1
Temperature display and setting .................................................................... 2
Removing the faceplate.................................................................................. 3
Wiring ............................................................................................................. 4
Installing the faceplate.................................................................................... 5
Setup procedure.............................................................................................6
Setup menu.................................................................................................... 7
In case of difficulty..........................................................................................8
Specifications .................................................................................................9
Warranty....................................................................................................... 10
Customer assistance.................................................................................... 11
ENGLISH
Owner’s Guide
About your new thermostat
This thermostat can be used to control an electric heating system such as a baseboard heater, a radiant floor, a radiant ceiling, a convector or a fan-forced
ENGLISH
heater.
The thermostat CANNOT be used with:
• a resistive load under 0.83 A
• a resistive load over 10.4 A
• a system driven by a contactor or a relay (inductive load)
• a central heating system
SUPPLIED PARTS
• One (1) thermostat
• Two (2) 6-32 mounting screws
• Two (2) solderless connectors
1
72838 / TH401
Temperature display and setting
Appears when the setpoint is displayed
Temperature display
Appears when the thermostat is configured for 5-minute cycles. The thermostat must be set to this configuration if it is controlling a fan-forced heater.
Heating intensity indicator. (No image appears when heating is off.)
The thermostat normally displays the actual (ambient) temperature.
• To view the setpoint temperature, briefly press the Up or Down button. The setpoint will
be displayed for 5 seconds and the screen illuminated for 12 seconds.
• To change the setpoint temperature, press the Up or Down button until the desired
value is displayed.
2
Up button Down button
ENGLISH
Owner’s Guide
Removing the faceplate
TURN OFF POWER OF THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRIC SHOCK.
ENGLISH
Loosen the screw holding the faceplate to the base. The screw cannot be completely removed and remains captive on the base. Remove the faceplate from the base by pulling the bottom half.
3
72838 / TH401
Wiring
Connect any one of thermostat wires to the
2-wire installation
heater (load) wire and the other one to the power supply wire using solderless connectors for copper wires. (The thermostat wires are non-polarized; either wire can be connected to the load or to the power supply.)
NOTE: All cables and connections must conform to the local electrical code. Special CO/ALR solderless connectors must be used when connecting with aluminium conductors.
4
4-wire installation
ENGLISH
Owner’s Guide
Installing the faceplate
Install the base onto an electrical box.
ENGLISH
Reinstall the faceplate on the base and secure it in place with the screw.
NOTE: Keep the air vents of ther­mostat clean and unobstructed at all times.
5
72838 / TH401
Setup procedure
The setup menu is shown on the following page.
n Press the Up and Down buttons simultaneously for three seconds to enter
the setup menu.
o Press the Up or Down button to change the option. p Press the Up and Down buttons simultaneously for one second to advance
to the next parameter.
q When the last parameter is displayed, press the Up and Down buttons for
three seconds to save any changes and exit the menu.
NOTE: cally save any changes you have made and will then
If you do not press any button for one minute,
6
the thermostat will automati-
return to its normal display
ENGLISH
.
Owner’s Guide
Setup menu
Parameter Options
ENGLISH
Temperature display format
Display and
default setting
•°C
•°F
Heating cycle
Minimum setpoint 5°C - 20°C (41°F - 68°F)
Maximum setpoint 15°C - 30°C (59°F - 86°F)
• Std (conventional heating): 15 seconds
• Fan (fan-forced heating): 5 minutes
7
In case of difficulty
72838 / TH401
PROBLEM SOLUTIONS
Thermostat is hot. This is normal.
Remediate if any the following conditions exists:
Displayed tempera­ture is wrong.
Display disappears and reappears after a few minutes.
• The thermostat is exposed to air draft.
• The sticker on the thermostat’s screen has not been removed.
• The thermostat is located near or above a heat source such as a light dimmer.
The thermal protection device on the heater has temporarily opened. This can happen if the heater is obstructed by furniture or curtain and has overheated, or if the heater’s thermal protection device is too sensitive.
8
ENGLISH
Owner’s Guide
Specifications
- Supply: 120/240 VAC, 60 Hz
- Minimum load: 0.83 A (resistive only)
ENGLISH
- Maximum load: 10.4 A (resistive only)
- Display range: 0°C to 50°C (32°F to 122°F)
- Setpoint range: 5°C to 30°C (40°F to 85°F)
- Storage: -20°C to 50°C (-4°F to 120°F)
- Heating cycle length: 15 seconds / 5 minutes (user-selectable)
- Permanent memory: You do not need to adjust the temperature following a power outage.
200 W @ 240 VAC 100 W @ 120 VAC
2500 W @ 240 VAC 1250 W @ 120 VAC
9
Loading...