INSTALLATION AND SETUP GUIDE
MAGNET ALIGNMENT STRIP
CASE
HOLDING
POSTS (2)
PLATE
MOUNTING
HOLES (2)
CONCEALED
WIRING
ENTRY HOLE
CASE
LOCKING
TAB
Diagram 1. Mounting Plate
GENERAL INFORMATION
The 5816AP is a Door/Window Transmitter
intended for use in systems that support 5800AP
wireless devices. It has its own unique serial
number permanently assigned during
manufacture. You must “enroll” the transmitter
serial number in the control prior to its usage in
the system. Refer to the control unit’s installation
instructions for further details.
programming of the control unit, 5816AP
transmitters shall be defined as the Input Type
“RF” (i.e., supervised RF).
The 5816AP has
two
unique zones; the
a wired closed circuit contact loop and the
for its built-in reed switch (used in conjunction with
a magnet as described below). Either or both
zones may be used.
A built-in cover tamper switch is activated when
the cover is removed.
INSTALLATION
Mounting
For proper orientation of the unit in relation to the
mounting plate, loop wiring, and/or magnet, read
all of this section before installing the unit.
The description that follows assumes that the unit
will be mounted as shown in the diagrams, with
the magnet (if used) located to the unit’s right. The
unit may, however, be installed in
as long as the relationship of the unit to its
mounting plate and (if used) magnet is
maintained.
Although two holes are provided in the unit that
would permit mounting directly to a surface (holes
‘A’ in Diagram 2) it is recommended that the
mounting plate be used, for ease in removing the
unit for servicing should it become necessary.
5816-002-V0
Note:
first
any
direction,
During
is for
second
N6482-4V1 4/05 Rev. A
ADEMCO 5816AP
Door/Window Transmitter
HOLES "A" (2)
(SEE TEXT)
ANTENNA
COVER
TAMPER
SWITCH
COVER
HOLDING
HOOKS (2)
LOCKING TAB
RELEASE
WINDOW
Diagram 2. Transmitter, Cover Removed
Before mounting the transmitter permanently,
SURFACE WIRING
conduct Go/No Go tests (see control’s
instructions) to verify adequate signal strength
and reorient or relocate the transmitter if
necessary.
1. Remove the transmitter’s cover by inserting
the flat blade of a small screwdriver into the
pry-off slot at the end of the unit farthest from
the cover’s decorative ribs, and twisting the
blade.
2. Disengage the supplied mounting plate
from the unit by inserting the blade of a small
screwdriver into the locking tab release
window (see Diagram 2) and pressing it
against the locking tab (see Diagram 1) while
sliding the plate downward along the case
back.
3. If a wired contact loop is to be used with
concealed
wiring, feed the wires through the
concealed wiring entry hole at one corner of
the mounting plate.
surface
For
wiring entry, a thin “breakout”
area is provided in the case wall. Wiring can
be run through this “breakout” in the case
when attaching the case in step 5.
4. Install the mounting plate, with its case
holding posts pointing up (in this example), in
the location selected as described in the
control unit’s installation instructions. Use the
flat head screws supplied.
5. Attach the case back to the mounting plate
by sliding the keyhole slots in the case back
down onto the mounting plate’s case holding
posts. The locking tab will click as the case
back locks in place.
6. If the unit’s reed switch is to be used, a No.
5799 Magnet (obtain separately) shall be
mounted adjacent to the alignment marks on
the case and the mounting plate’s alignment
strip (see Diagram 2).
A
+
BATTERY
REED
SWITCH
(INPUT 2)
–
A
BREAKOUT FOR
COVER PRY-OFF POINT
ALIGN MAGNET
WITH MARKS ON
CASE AND GUIDE
ON MTG. PLATE
MAGNET
(OBTAIN
SEPARATELY)
NOTE
HAS 2
1/2” MAX.
UNIQUE
ZONES
LOOP
TERMINALS
(INPUT 1)
SLOT FOR CONCEALED
WIRING ACCESS
5816
5816-001-V0
Note:
Wiring Connections
With the battery still not inserted, connect the
contact loop (if used) to the unit’s loop terminals
(see Figure 2).
circuit devices.
The contact loop must use closed
Note: If the contact loop is not to be used, no
connection is needed across its terminals.
BATTERY INSTALLATION/REPLACEMENT
1. Remove the transmitter’s cover (if it is not
already off) as described in
2. Observe correct polarity and insert the
Mounting
Step 1.
battery provided into the battery holder (see
Diagram 2).
antenna.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference
received, including interference that may cause
undesired operation.
Regular maintenance and inspection (at least annually) by the installer and frequent testing by the user are vital to
continuous satisfactory operation of any alarm system.
The installer should assume the responsibility of developing and offering a regular maintenance program to the
user, as well as acquainting the user with the proper operation and limitations of the alarm system and its
component parts. Recommendations must be included for a specific program of frequent testing (at least weekly) to
insure the system’s operation at all times.
Take care not to bend the
FCC ID: CFS8DL5816AP
TO THE INSTALLER
Replace battery
Panasonic CR123A, Duracell DL123A,
Sanyo CR123A, Varta CR123A, or
ADEMCO 466.
3. To replace the cover, engage the hooks
along one edge and snap shut.
SPECIFICATIONS
Transmission Frequency: 315MHz
Dimensions: 1-9/16”W x 3-1/16”H x 1-3/16”D
(40mm x 78mm x30mm)
Battery: 3V Lithium (see Note in step 2 of
BATTERY INSTALLATION/REPLACEMENT
BATTERY CAUTION: Risk of fire, explosion
and burns. Do not recharge, disassemble, heat
above 212 F (100 C) or incinerate. Dispose of
used batteries promptly. Keep away from
children.
only
with:
)
REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS DEVICE IS
USED, FOR LIMITATIONS OF THE ENTIRE ALARM SYSTEM.
Honeywell International Inc., acting through its Security & Custom Electronics business ("Seller") 165 Eileen Way, Syosset,
New York 11791, warrants its product(s) to be in conformance with its own plans and specifications and to be free from
defects in materials and workmanship under normal use and service for 24 months from the date stamp control on the
product(s) or, for product(s) not having a manufacturer’s date stamp, for 12 months from date of original purchase unless the
installation instructions or catalog sets forth a shorter period, in which case the shorter period shall apply. Seller's obligation
shall be limited to repairing or replacing, at its option, free of charge for materials or labor, any product(s) which is proved not
in compliance with Seller's specifications or proves defective in materials or workmanship under normal use and service.
Seller shall have no obligation under this Limited Warranty or otherwise if the product(s) is altered or improperly repaired or
serviced by anyone other than Honeywell factory service. For warranty service, return product(s) transportation prepaid, to
Honeywell Factory Service, 165 Eileen Way, Syosset, New York 11791.
THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, OF MERCHANTABILITY, OR FITNESS FOR A PARTICULAR
PURPOSE OR OTHERWISE, WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO CASE
SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF
THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, OR UPON ANY OTHER BASIS OF LIABILITY
WHATSOEVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER'S OWN NEGLIGENCE OR FAULT.
Seller does not represent that the product(s) it sells may not be compromised or circumvented; that the product(s) will
prevent any personal injury or property loss by burglary, robbery, fire or otherwise; or that the product(s) will in all cases
provide adequate warning or protection. Customer understands that a properly installed and maintained alarm system may
only reduce the risk of a burglary, robbery, fire, or other events occurring without providing an alarm, but it is not insurance or
a guarantee that such will not occur or that there will be no personal injury or property loss as a result. CONSEQUENTLY,
SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROPERTY DAMAGE OR OTHER LOSS BASED
ON A CLAIM THAT THE PRODUCT(S) FAILED TO GIVE WARNING. HOWEVER, IF SELLER IS HELD LIABLE,
WHETHER DIRECTLY OR INDIRECTLY, FOR ANY LOSS OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY
OR OTHERWISE, REGARDLESS OF CAUSE OR ORIGIN, SELLER'S MAXIMUM LIABILITY SHALL NOT IN ANY CASE
EXCEED THE PURCHASE PRICE OF THE PRODUCT(S), WHICH SHALL BE THE COMPLETE AND EXCLUSIVE
REMEDY AGAINST SELLER.
This warranty replaces any previous warranties and is the only warranty made by Seller on this product(s). No increase or
alteration, written or verbal, of the obligations of this Limited Warranty is authorize.
LIMITED WARRANTY
165 Eileen Way, Syosset, New York 11791
ÊN6482-4V1ÁŠ
N6482-4V1 Rev.A 4/05
Copyright © 2004 Honeywell International, Inc.
www.honeywell.com/security