Aller à www.honeywellaidc.com pour le français.
Vai a www.honeywellaidc.com per l'italiano.
Gehe zu www.honeywellaidc.com für Deutsch.
Ir a www.honeywellaidc.com para español.
Note: Refer to your user’s guide for information about cleaning your
device.
For localized language versions of this document, go to
www.honeywellaidc.com.
Getting Started
Turn off computer’s power before connecting the scanner, then
power up the computer once the scanner is fully connected.
Page 3
USB Connection
Keyboard Wedge Connection
Page 4
Serial (RS-232) Connection
Reading Techniques
The view finder projects an aiming
beam that should be centered over
the bar code, but it can be
positioned in any direction for a
good read.
Hold the scanner over the bar code,
pull the trigger, and center the
aiming beam on the bar code.
The aiming beam is smaller when
the scanner is closer to the code and larger when it is farther from the
code. Hold the scanner close to smaller bar codes, and farther away
from large bar codes to get a proper read.
If the bar code is highly reflective (e.g., laminated), you may need to
tilt the scanner at an angle so the bar code can be scanned.
Page 5
Standard Product Defaults
Standard Product Defaults
The following bar code resets all standard product default settings.
Page 6
Interface
AT/PS2 Keyboard Wedge
(Default)
RS-232
USB Keyboard (PC)
Emulate External Keyboard
Japan DOS/V
USB Japanese Keyboard (PC)
Scan the bar code that describes the PC or interface you are using.
Page 7
Keyboard Country
Program Keyboard Country
Save
Scan the Program Keyboard Country bar code below, then scan
the numeric bar code(s) from the back of this sheet, then the Save
bar code to program the keyboard for your country. As a general
rule, the following characters are not supported by the scanner for
countries other than the United States:
@ | $ # { } [ ] = / ‘ \ < > ~.
Country CodeScanCountry CodeScan
Belgium1Italy5
Denmark8Norway9
Finland2Spain10
France3Switzerland6
Germany/Austria4USA (Default)0
Great Britain7
Note: For a complete list of country codes, see the User’s Guide for
your product at our website,
www.honeywellaidc.com.
Page 8
Trigger
Manual Trigger
(Default)
Presentation Mode
Streaming Presentation Mode
The following bar codes will allow you to use the reader in Manual
Trigger mode (need to press the trigger to read) or Presentation
mode (the reader is activated when it “sees” a bar code).
Streaming Presentation™
Note: Streaming Presentation Mode applies only to units with the
Advanced Illumination feature. Units with the advanced
illumination feature have a software revision of 31205480-118
or newer.
When in Streaming Presentation mode, the imager leaves the scan
illumination on all the time and continuously searches for bar codes.
Page 9
Reread Delay
Medium Reread Delay
Add CR Suffix
Remove Suffix
Add Tab Suffix
This sets the time period before the scanner can read the
code a second time. Setting a reread delay protects against
accidental rereads of the same bar code.
same
bar
Suffix
If you want a carriage return after the bar code, scan the Add CR
Suffix bar code. To add a tab after the bar code, scan the Add Tab
Suffix bar code. Otherwise, scan the Remove Suffix bar code to
remove the suffixes.
Page 10
Add Code ID Prefix to all Symbologies
Add Code ID Prefix To All Symbologies
(Temporary)
Enable
(Default)
Disable
Scan the following bar code if you wish to add a Code ID prefix to all
symbologies at once.
Note: For a complete list of Code IDs, see the User’s Guide for your
product at our website,
www.honeywellaidc.com.
Function Code Transmit
When this selection is enabled and function codes are contained
within the scanned data, the imager transmits the function code to the
terminal. Charts of these function codes are provided in your User’s
Guide. When the imager is in keyboard wedge mode, the scan code
is converted to a key code before it is transmitted.
Page 11
Data Format Editor Instructions
Enter Data Format
Clear All Data Formats
Save
The following are abbreviated instructions for entering a data format.
For complete instructions refer to your User’s Guide, available at our
website,
1. Scan the Enter Data Format symbol.
2. Primary/Alternate Format: scan 0 for Primary Format
3. Terminal Type: scan 099 for any terminal type
4. Code I.D.: scan 99 for any bar code type
5. Length: scan 9999 for any length bar code.
6. Editor commands: use the Programming Chart that follows.
7. Scan Save to save your entries.
www.honeywellaidc.com.
Page 12
Programming Chart
0
2
1
4
3
5
6
7
8
Page 13
A
B
C
D
E
F
9
Save
Page 14
Visual Xpress™
To obtain access to additional features for the imager, use Visual
Xpress, available from our website at www.honeywellaidc.com. For
complete download instructions and descriptions of Visual Xpress
features, refer to your User’s Guide.
Technical Assistance
Contact information for technical support, product service, and repair
can be found at
www.honeywellaidc.com.
Limited Warranty
Refer to www.honeywellaidc.com/warranty_information for your
product’s warranty information.
User Documentation
For localized versions of this document, and to download the User’s
Guide, go to
www.honeywellaidc.com.
Patents
For patent information, go to www.honeywellaidc.com/patents.
Disclaimer
Honeywell International Inc. (“HII”) reserves the right to make changes in
specifications and other information contained in this document without prior
notice, and the reader should in all cases consult HII to determine whether
any such changes have been made. The information in this publication does
not represent a commitment on the part of HII.
HII shall not be liable for technical or editorial errors or omissions contained
herein; nor for incidental or consequential damages resulting from the
furnishing, performance, or use of this material.
Page 15
This document contains proprietary information that is protected by copyright.
All rights are reserved. No part of this document may be photocopied,
reproduced, or translated into another language without the prior written
consent of HII.