Honeywell 202516TXR User Manual

L506 Wireless Lamp Control Module Installation Guide
The L506 FET dimmer can drive dimmable CFL loads and other loads:
100W Incandescent
35W Dimmable CFL or 100W incandescent equivalent
25W LED or 100W incandescent equivalent
As an alternative to the L206 lamp socket module, the L506 provides wireless lamp control with a smaller footprint. Designed for standard medium lamp sockets (E26 Edison), the RF-equipped device can be controlled from any INNCOM IRAS device with an RF transceiver. The socket is equipped with a mechanical button that can control the load and assist in device binding. The L506 series will eventually incorporate sibling products designed for other lamp socket types.
Installation
The installer must be a trained,
experienced service technician.
When installing this product:
1. Read the instructions carefully.
Failure to follow them could
damage the product or cause
hazardous conditions.
2. Check the ratings given in the
product guide to make sure the
product is suitable for your
application..
3. Use the L506 module
only with a recognized
or listed lamp holder
assembly.
CAUTION: The distance between the bulb and the
shade should be equal to or greater than required by the original UL listing for the lamp base. Improper placement is a fire hazard.
Mounting
The L506 may be mounted in vertical/bulb up, horizontal, or vertical/bulb down fixtures. The bulb-down orientation should generally be confined to open air installations; if used with a shade, the fixture should be further derated (see table below).
1. If the lamp’s Edison socket has a
switch, make sure it is in the full
on position, then remove or
disable it.
2. The L506 dimmer-equipped lamp
must be within 60 feet (indoors) of
an RF transceiver/repeater.
3. Unplug the lamp cord from the
power source (e.g., wall socket).
4. Remove any shade and lamp
harp.
5. Remove the bulb; screw the L506
dimmer/switch into the lamp
socket.
6. Reinstall the bulb, then the lamp
harp (if used). Rotate the harp if
necessary to clear the L506
socket. Plug the lamp back into
the power supply.
CAUTION:
Derating: Do not exceed an ambient air temperature of 25˚C surrounding the L506 Lamp Controller when operating the lamp with the specified loads and orientations, as outlined in the following table.
Maximum Ratings
Incandescent
Dimmable CFL
LED 25W 10W
*Open air only. If fixture enclosed, further derating is necessary
Vertical Base Down (bulb up) or
Horizontal
100W
35W
Vertical
Base Up
(bulb
down)*
60W
20W
Communications
The L506 can switch on a light using the built-in on/off button. For remote and dimming operation, the L506 must be located within 60 ft. of an originating RF transmitter (any IRAS RF device can be configured as a repeater). The L506 must be commissioned. The outline below assumes the installer understands the commissioning process in general; specific commissioning procedures can be found on the property-specific commissioning sheet.
Commissioning
The L506 must be bound to an RF control device such as an e528 thermostat.
1. The L506 enters bind mode for the
first 2 minutes after powering up;
www.inncom.com 1
to re-enter bind mode, unscrew
the L506 from the fixture and then
screw it back in.
2. On the e528, enter the Service
menu.
Press and hold the F°/C°
button
Press and release
OFF/AUTO
Press and release DISPLAY
Release F°/C°
3. Use the UP or DOWN arrows to
go to the Address parameter
(ADR).
4. Press DISPLAY. Use the
UP/DOWN arrows to enter the
ADR value from the
commissioning sheet.
5. Press OFF/AUTO; a single beep
should sound.
6. On the L506, press and hold the
built-in on/off button for 5 seconds.
The e528 will beep quickly 3 times
to confirm binding.
Parameter Rating
Dimensions: 63.3mm L × 47.3mm
W x 98mm H (with
socket)
Approvals
FCC Part 15b, Class
A, UL
FCC ID: GTC202516TXR
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and
found to comply with the limits for a
Class B digital device, pursuant to
Part 15 of the FCC Rules. These
limits are designed to provide
reasonable protection against
by turning the equipment off and on,
the user is encouraged to try to
correct the interference by one of the
following measures:
—Reorient or relocate the receiving
antenna.
—Increase the separation between
the equipment and receiver.
—Connect the equipment into an
outlet on a circuit different from that
to which the receiver is connected.
—Consult the dealer or an
experienced radio/TV technician for
help.
Any changes or modifications not
expressly approved by the party
responsible for compliance could
Operation
Besides being used in the binding operation, the built-in button on the L506 can control the lighting load. Press and hold the button to adjust lighting (dimming) levels up or down. A quick press will turn the light off or on.
The L506 has a status indicator LED. When the lamp is on, the LED is too.
Technical Specifications
Parameter Rating
Power 110-120VAC, 50/60Hz
0.9A dimmable output
Standby power Standby current Operating Environment
1.3W 11mA
0–25 C˚
harmful interference in a residential
installation. This equipment
generates, uses, and can radiate
radio frequency energy and, if not
installed and used in accordance with
the instructions, may cause harmful
interference to radio
communications. However, there is
no guarantee that interference will
not occur in a particular installation. If
this equipment does cause harmful
interference to radio or television
reception, which can be determined
void the user's authority to operate
this equipment.
C ID: 1609A-202516TXR
This device complies with Industry
Canada license-exempt RSS
standard(s). Operation is subject to
the following two conditions: (1) this
device may not cause interference,
and (2) this device must accept any
interference, including interference
that may cause undesired operation
of the device.
Le présent appareil est conforme aux
www.inncom.com 2
Loading...
+ 1 hidden pages