Hikvision DS-K2M060 User Manual

DS-K2M060 Secure Door Control Unit
User Manual
V1.0.0
UD01462B
1
Secure Door Control Unit Hikvision.com
User Manual
COPYRIGHT © 2016 Hangzhou Hikvision Digital Technology Co., Ltd. ALL RIGHTS RESERVED. Any and all information, including, among others, wordings, pictures, graphs are the properties of Hangzhou Hikvision Digital Technology Co., Ltd. or its
subsidiaries (hereinafter referred to be “Hikvision”). This user manual (hereinafter referred to be “the Manual”) cannot be reproduced, changed,
translated, or distributed, partially or wholly, by any means, without the prior written permission of Hikvision. Unless otherwise stipulated, Hikvision does not make any warranties, guarantees or representations, express or implied, regarding to the Manual.
About this Manual
This Manual is applicable to Secure Door Control Unit. The Manual includes instructions for using and managing the product. Pictures, charts, images and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change, without notice, due to firmware updates or other reasons. Please find the latest version in the company website (http://overseas.hikvision.com/en/). Please use this user manual under the guidance of professionals.
Trademarks Acknowledgement
Hikvision in various jurisdictions. Other trademarks and logos mentioned below are the properties of their respective owners.
Legal Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, IS PROVIDED “AS
IS”, WITH ALL FAULTS AND ERRORS, AND HIKVISION MAKES NO WARRANTIES,
EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF THIRD PARTY. IN NO EVENT WILL HIKVISION, ITS DIRECTORS, OFFICERS, EMPLOYEES, OR AGENTS BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL , OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA OR DOCUMENTATION, IN CONNECTION WITH THE USE OF THIS PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. REGARDING TO THE PRODUCT WITH INTERNET ACCESS, THE USE OF PRODUCT SHALL BE WHOLLY AT YOUR OWN RISKS. HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER
and other Hikvision’s trademarks and logos are the properties of
i
Secure Door Control Unit Hikvision.com
DAMAGES RESULTING FROM CYBER ATTACK, HACKER ATTACK, VIRUS INSPECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED. SURVEILLANCE LAWS VARY BY JURISDICTION. PLEASE CHECK ALL RELEVANT LAWS IN YOUR JURISDICTION BEFORE USING THIS PRODUCT IN ORDER TO ENSURE THAT YOUR USE CONFORMS THE APPLICABLE LAW. HIKVISION SHALL NOT BE LIABLE IN THE EVENT THAT THIS PRODUCT IS USED WITH ILLEG ITIMATE PURPOSES. IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER PREVAILS.
Regulatory Information FCC Information FCC compliance: This equipment has been tested and found to comply with the
limits for a digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
FCC Conditions
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operation.
EU Conformity Statement
This product and - if applicable - the supplied accessories too are marked with "CE" and comply therefore with the applicable harmonized European standards listed under the EMC Directive 2004/108/EC, the RoHS Directive 2011/65/EU.
2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information, see: www.recyclethis.info.
ii
Secure Door Control Unit Hikvision.com
Warnings Follow these safeguards to prevent serious injury or death.
Cautions Follow these precautions to
prevent potential injury or material
damage.
2006/66/EC (battery directive): This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union. See the product documentation for specific battery information. The battery is marked with this symbol, which may include lettering to indicate cadmium (Cd), lead
to your supplier or to a designated collection point. For more information see:
www.recyclethis.info.
Industry Canada ICES-003 Compliance This device meets the CAN ICES-3 (A)/NMB-3(A) standards requirements.
Safety Instruction
These instructions are intended to ensure that user can use the product correctly to avoid danger or property loss. The precaution measure is divided into Warnings and Cautions:
Warnings: Neglecting any of the warnings may cause serious injury or death. Cautions: Neglecting any of the cautions may cause injury or equipment damage.
Warnings
All the electronic operation should be strictly compliance with the electrical
safety regulations, fire prevention regulations and other related regulations in your local region.
Please use the power adapter, which is provided by normal company. The
power consumption cannot be less than the required value.
Do not connect several devices to one power adapter as adapter overload may
cause over-heat or fire hazard.
Please make sure that the power has been disconnected before you wire,
install or dismantle the device.
When the product is installed on wall or ceiling, the device shall be firmly
fixed.
If smoke, odors or noise rise from the device, turn off the power at once and
unplug the power cable, and then please contact the service center.
(Pb), or mercury (Hg). For proper recycling, return the battery
iii
Secure Door Control Unit Hikvision.com
If the product does not work properly, please contact your dealer or the
nearest service center. Never attempt to disassemble the device yourself. (We shall not assume any responsibility for problems caused by unauthorized repair or maintenance.)
Cautions
Do not drop the device or subject it to physical shock, and do not expose it to
high electromagnetism radiation. Avoid the equipment installation on vibrations surface or places subject to shock (ignorance can cause equipment damage).
Do not place the device in extremely hot (refer to the specification of the
device for the detailed operating temperature), cold, dusty or damp locations, and do not expose it to high electromagnetic radiation.
The device cover for indoor use shall be kept from rain and moisture. Exposing the equipment to direct sun light, low ventilation or heat source such
as heater or radiator is forbidden (ignorance can cause fire danger).
Do not aim the device at the sun or extra bright places. A blooming or smear
may occur otherwise (which is not a malfunction however), and affecting the endurance of sensor at the same time.
Please use the provided glove when open up the device cover, avoid direct
contact with the device cover, because the acidic sweat of the fingers may erode the surface coating of the device cover.
Please use a soft and dry cloth when clean inside and outside surfaces of the
device cover, do not use alkaline detergents.
Please keep all wrappers after unpack them for future use. In case of any
failure occurred, you need to return the device to the factory with the original wrapper. Transportation without the original wrapper may result in damage on the device and lead to additional costs.
iv
Secure Door Control Unit www.hikvision.com
Contents
Chapter 1 Overview................................................................ 2
1.1 Introduction ................................................................. 2
1.2 Introducing the Appearance ......................................... 2
1.2.1 Front View .............................................................. 2
1.2.2 Rear View (Dial-up) ................................................. 3
1.3 Introducing Indicators .................................................. 4
Chapter 2 Installation ............................................................. 6
2.1 Introduction of DIP Switch ............................................ 6
2.2 Wiring Cables ............................................................... 8
2.3 Installing Secure Door Control Unit ............................ 12
Chapter 3 Wiring External Device ........................................ 14
1
Secure Door Control Unit www.hikvision.com
Chapter 1 Overview
1.1 Introduction
DS-K2M060 Secure Door Control Unit (hereinafter referred as unit) can be applied to keep the door in the status before down when the door is down or damaged. DS-K2M060 Secure Door Control Unit is the interlayer between the access control terminal and the lock, including the door contact, the lock, the exit button, the Wiegand card reader and so on. It is much safer to apply the secure door control unit with the access control terminal.
1.2 Introducing the Appearance
1.2.1 Front View
The front view of DS- K2M060 Secure Door Control Unit is shown as below:
Figure 1. 1 Front View of Secure Door Control Unit
2
Secure Door Control Unit www.hikvision.com
3
2
1
4
No.
Name
1
Cable Interface of RS-485, Power, LED Control, etc.
2
Tampering Prevention Switch
3
DIP Switch (For details, see Chapter 2.1
Introduction of DIP Switch)
4
Wiegand Interface
1.2.2 Rear View (Dial-up)
The rear view of DS- K2M060 Secure Door Control Unit is shown as below:
Figure 1. 2 Rear View of Secure Door Control Unit
Table 1. 1 Description of Rear View
3
Secure Door Control Unit www.hikvision.com
Solid Red
The unit is powered on.
Flicking Green
The tempering prevention switch is open. Tempering alarm.
Solid Green
The tempering prevention switch is open. The device is running.
Flicking Green
The RS 485 communication is built.
Solid Greed
The RS 485 communication is not built.
Green
The indicator will be solid green for a while when the opening door action is done. (The opening door action includes swiping the card, remote opening door and so on.)
Notes:
Make sure the unit is powered on. Make sure the unit is connecting the lock.
Green
The indicator is solid green when the door is open. When the door is closed, the indicator is off.
Notes:
Make sure the unit is powered on. Make sure the unit is connecting the door
contact.
1.3 Introducing Indicators
The Indicators of DS-K2M060 Secure Door Control Unit are POWER, RUN, RX, TX, RELAY, SENSOR and BUTTON. The following tables introduce the meaning of different indicators status:
POWER:
RUN:
RX, TX - RS 485 Communication Indicator:
RELAY: Indicate the lock status:
SENSOR – Indicate the door contact status:
4
Secure Door Control Unit www.hikvision.com
Green
The green light is on when press the Exit button. When release the button, the green light will be off.
Notes:
Make sure the unit is powered on. Make sure the unit is connecting the Exit
button.
BUTTON – Indicate the Exit button
5
Secure Door Control Unit www.hikvision.com
Icon
Description
Represent 0 in binary mode
Represent 1 in binary mode
Chapter 2 Installation
2.1 Introduction of DIP Switch
For the DIP switch position, please refer to No.3 of Table 2.1 Description of Rear View. The DIP switch module is shown below. The number of DIP switch from left to right is 1 to 4.
Figure 2. 1 DIP Switch Module (Binary Code: 0000)
The table shows below is the description of the DIP switch.
Table 2. 1 Description of DIP Switch
For example, the binary codes of the following figure from No.1 to 4 are 0011 respectively.
6
Secure Door Control Unit www.hikvision.com
Figure 2. 2 DIP Switch Module (Binary Code: 0011)
The DIP switch in the secure door control unit is for the RS-485 communication. The code range is from 1 to 15, namely the binary code range between 0001 and 1111. The code cannot be repeated.
7
Secure Door Control Unit www.hikvision.com
Group A
Group B
Group D
Group E
A1
A2
B1 B2
D1 D2 D3
E1 E2 E3
Power Input
Sensor Input
Lock Output
RS-485
Red
Black
Green/Brown Black
White/Purple White/Black White/Red
Yellow
Black Blue
C1 C2
Door Button
Group C
Green/Black Black
Group
Cable
No.
Color
Name
Descriptions
A A1
Red
+12V
Power Input
A2
Black
GND
2.2 Wiring Cables
Purpose:
Wire cables between Access Control Terminal, Secure Door Control Unit and the lock input/output devices (Wiring to the Wiegand card reader is optional.) to establish the communication between them.
Steps:
1. Set the DIP switch code. The binary code range is between
0001 and 1111. For details, please refer to Chapter 2.1 Introduction of DIP Switch.
2. Plug the Terminal 1 to the Interface 1 as shown in Figure 2.3
and Figure 2.4.
Figure 2. 3 Terminals 1
The table displayed below shows the terminal 1 description:
Table 2. 2 Terminals Descriptions of Secure Door Control Unit
8
Secure Door Control Unit www.hikvision.com
Group
Cable
No.
Color
Name
Descriptions
B B1
Green/Brown
DOOR_SENSOR
Sensor Input
B2
Black
GND
C C1
Green/Black
DOOR_BUTTON
Door Button
C2
Black
GND
D
D1
White/Purple
RELAY_NC
Lock Output
D2
White/Black
RELAY_COM
D3
White/Red
RELAY_NO
E
E1
Yellow
RS485 +
RS-485
E2
Black
GND
E3
Blue
RS485 -
Interface 1
Figure 2. 4 Rear View of Secure Door Control Unit
9
Secure Door Control Unit www.hikvision.com
F1
F2 F3
F4
F5
F6
Wiegand
Brown
Purple
Orange Green
White
Black
Group
Cable No.
Color
Name
Descriptions
F
F1
Brown
OK
Wiegand
F2
Purple
BUZZER
F3
Orange
ERR
F4
Green
W0
F5
White
W1
F6
Black
GND
3. Plug the Wiegand Terminal 2 to the Wiegand as shown in
Figure 2.5 and Figure 2.6. The Interface 2 represents the Wiegand interface.
Figure 2. 5 Terminals 2
The table displayed below shows the terminal 2 descriptions:
Table 2. 3 Terminals Descriptions of Secure Door Control Unit
10
Secure Door Control Unit www.hikvision.com
Interface 2
Figure 2. 6 Rear View of Secure Door Control Unit
11
Secure Door Control Unit www.hikvision.com
2.3 Installing Secure Door Control Unit
Steps:
1. Drill holes on the wall or other places according to the
mounting template.
Note: The minimum bearing weight of the wall or other places
should be three times heavier than the device weight.
2. Insert the screw sockets of the setscrews in the drilled holes.
3. Plug the cables of power input, lock input, lock output and
RS-485 as well as the Wiegand cables to the target interfaces. (For details, please see Chapter 2.2 Wiring Cables)
4. Align the screw holes on the two sides of the secure door
control unit with the holes on the wall.
5. Fix and fasten the secure door control unit on the wall by the
supplied screws.
Note: Knock down the hole on the one side of the unit, as
shown in Figure 3.5, if cables need to go from the side.
12
Secure Door Control Unit www.hikvision.com
The hole can be knocked down.
Figure 2. 7 Fix on the Wall
13
Secure Door Control Unit www.hikvision.com
Chapter 3 Wiring External Device
The figure displayed below is the wiring introduction of external device:
Figure 3. 1 External Device Wiring
0100001060602
14
Secure Door Control Unit www.hikvision.com
Loading...