Heath Zenith SL-5411-WH User Manual

0 (0)

Motion Sensor Light

Control

As an ENERGY STAR® Partner, Heath®/Zenith has determined that this product meets the ENERGY STAR® guidelines for energy efficiency.

This product is ENERGY STAR® compliant when used with 120 Watt bulbs.

Model SL-5411

Features

Turns on lighting when motion is detected.

Automatically turns lighting off.

Photocell keeps the lighting off during daylight hours.

LED indicates motion was sensed (day or night).

This package includes:

Lamp

 

 

Holders

 

Rubber Plug

 

 

Cover

 

Plastic Hanger

 

 

Plate

 

 

 

Sensor

 

Light Control

2 Wire

 

 

 

 

Connectors

Mounting Bolt

Mounting Strap

 

Gasket

6 Screws

2 Flood Lamps (3 sizes included) (some versions)

Requirements

The light control requires 120-volts AC.

If you want to use Manual Mode, the control must be wired through a switch.

Some codes require installation by a qualified electrician.

This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations.

OPERATION

Mode:

On-Time

Works: Day

Night

Test

5 Seconds

x

x

Auto

1, 5, or 10 Min

 

x

Manual

Until Dawn*

 

x

* resets to Auto Mode at dawn.

Note: When first turned on wait about 1 1/2 minutes for the circuitry to calibrate.

TEST

Put the ON-TIME switch on the bottom ON-TIME of the sensor in the TEST position.

10 5 1 TEST

AUTO

Put the ON-TIME switch in the 1, 5,

ON-TIME

or 10 minute position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 5 1 TEST

 

 

 

 

 

 

 

MANUAL MODE

 

 

 

 

 

 

Manual mode only works at night because daylight returns the sensor to AUTO.

Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.

Manual mode works only with the ON-TIME switch in the 1, 5, or 10 position.

1 Second

OFF then...

 

 

 

 

 

 

 

 

... back on.

 

 

 

 

 

 

 

 

 

 

Mode Switching Summary

 

 

 

 

 

 

TEST

 

 

 

 

Move ON-TIME Switch to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1, 5, or 10 minutes

 

 

 

 

 

 

 

 

AUTO

 

 

 

 

 

Flip light switch off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for one second then

 

 

 

 

 

 

 

 

back on*

MANUAL MODE

 

 

 

 

 

 

 

*If you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time the control will be in the AUTO mode.

© 2007 HeathCo LLC

598-1128-03

Heath Zenith SL-5411-WH User Manual

INSTALLATION

For easy installation, select an existing light with a wall switch for replacement.

Route the light control’s wires through the large gasket holes.

Twist the junction box wires and fixture wires together as shown. Secure with wire connectors.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wall Mount

Eave Mount

For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock.

For eave mount only:

Swing the sensor head towards the clamp screw

joint.

Controls

 

 

Clamp Screw

Then rotate the sensor head clockwise 180° so the controls face down.

Controls

Controls

If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.

Wire the Light Control

WARNING: Turn power off at circuit breaker or fuse.

Remove the existing light fixture.

Install the mounting strap as shown using two screws that fit your junction box.

The plastic hanger can be used to hold the fixture while wiring. The small end of the plastic hanger can be threaded through the hole in the center of the cover plate. The small end then goes into one of the slots on the mounting strap.

Mounting

 

 

 

Black to

 

White to

Strap

Black

 

White

 

 

 

 

Rubber

Plug

Mounting

Bolt

Gasket

Junction box ground wire to green ground screw on fixture.

Mount the Light Control

Align the light control cover plate and cover plate gasket. Secure with the mounting bolt.

Push the Rubber Plug firmly into place.

If a wet location junction box was not used, caulk the wall plate mounting surface with silicone weather sealant.

To avoid water damage and electrical shock, keep lamp holders 30° below horizontal.

 

Keep lamps at least

 

1" (2.5 cm) from the

Lock Nut

sensor.Do not allow

 

the lamps to block

Lens

the lens.

Adjust the lamp holders by loosening the lock nuts but do not rotate the lamp holders more than 180° from the factory setting. When screwing in the floodlamps, do not overtighten.

598-1128-03

Clamp
Screw
Ball
Joint
Aim Sensor Down for Short Coverage
Aim Sensor Higher for Long Coverage

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on, wait 1 1/2 minutes.

Turn the RANGE control to the mid position and the ON-TIME control to the TEST position.

ON-TIME

RANGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 5 1 TEST

MIN MAX

Bottom of Sensor

Avoid aiming the control at:

Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.

8 ft.

150°

 

(2.4 m)

 

70 ft.

 

(21 m)

 

Maximum Range

Maximum

 

Coverage Angle

The detector is most sensitive to motion across its field of view.

Motion

Motion

Loosen the clamp screw in the sensor ball joint and gently rotate the sensor.

Walk through the coverage area noting where you are when the lights turn on (also, the LED will flash several times when motion is detected).Move the sensor head up, down, or sideways to change the coverage area. Keep the sensor at least 1" (2.5 cm) away from the lamps.

Adjust the RANGE as needed. RANGE set too high may

increase false triggering.

Secure the sensor head by tightening the clamp screw.

Do not overtighten the screw.

Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 10 minutes).

Warning - Risk of fire. Do not aim the lamps at a combustible surface within 3 ft. (1 m).

SPECIFICATIONS

Range. . . . . . . Up to 70 ft. (21 m) [varies with surrounding temperature].

Sensing Angle. . . . Up to 150°

Electrical Load. . . . Up to 300 Watt Maximum Incandescent [Up to 150 Watt maximum each lamp holder.]

Power Requirements. 120 VAC, 60 Hz

Operating Modes. . . TEST, AUTO and MANUAL

MODE

Time Delay . . . . . 1, 5, 10 minutes Range. . . . . . . Adjustable

HeathCo LLC reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.

 

Sensor

Least Sensitive

Most Sensitive

598-1128-03

TROUBLESHOOTING GUIDE

SYMPTOM

 

POSSIBLE CAUSE

 

 

 

 

 

Lights will not come

1. Light switch is turned off.

on.

 

 

2. Flood light

is

loose or

 

 

 

 

burned out.

 

 

 

 

 

3.

Fuse is blown or circuit breaker

 

 

 

 

is turned off.

 

 

 

 

 

4.

Daylight turn-off is in effect (re-

 

 

 

 

check after dark).

 

 

 

 

5.

Incorrect circuit wiring, if this is a

 

 

 

 

new installation.

 

 

 

 

6.

Re-aim the sensor to cover de-

 

 

 

 

sired area.

 

 

Lights

come

on

1. Light control may be installed in

in daylight.

 

 

a relatively dark location.

 

 

 

2.

Light control is in Test.

 

 

 

 

(Set control switch to an

 

 

 

 

ON-TIME position).

 

Lights

come

on

1. Light control

may

be sensing

for no

apparent

 

small animals or automobile traf-

reason.

 

 

 

fic (re-aim sensor).

 

 

 

 

2.

Range is set too high .

 

 

 

 

(Reduce Range).

 

 

 

 

 

 

 

 

SYMPTOM

POSSIBLE CAUSE

 

 

 

 

Lights stay on

1. A flood lamp is positioned too close to

continuously.

 

the sensor or pointed at nearby objects

 

 

that cause heat to trigger the sensor.

 

 

(Reposition the lamp away from the

 

 

sensor or nearby objects).

 

2.

Light control is pointed toward a heat

 

 

source like an air vent, dryer vent, or

 

 

brightly-painted heat-reflective sur-

 

 

face. (Reposition sensor).

 

3.

LightcontrolisinManualMode.(Switch

 

 

to Auto.)

Lights flash on

1. Heat or light from the lamps may be

and off.

 

turning the light control on and off.

 

 

(Reposition the lamps away from the

 

 

sensor).

 

2. Heat being reflected from other objects

 

 

may be affecting the sensor. (Reposi-

 

 

tion sensor).

 

3. Light control is in the Test mode and

 

 

warming up.(Flashing is normal under

 

 

these conditions).

 

4. Light may be leaking through the flood-

 

 

lampreflectors.(Replacethelampswith

 

 

new high quality PAR 38 lamps).

 

 

 

Technical Service

Please call 1-800-858-8501 (English speaking only) for assistance before returning product to store.

If you experience a problem, follow this guide.You may also want to visit our Web site at: www.hzsupport.com. If the problem persists, call* for assistance at 1-800-858-8501 (English speaking only), 7:30 AM to 4:30 PM CST (M-F). You may also write* to:

HeathCo LLC

P.O. Box 90004, Bowling Green, KY 42102-9004 ATTN: Technical Service

* If contacting Technical Service, please have the following information available: Model Number, Date of Purchase, and Place of Purchase.

No Service Parts Available for this Product

TEN YEAR LIMITED WARRANTY

This is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary from state to state or province to province.

For a period of ten years from the date of purchase, any malfunction caused by factory defective parts or workmanship will be corrected at no charge to you.

Not Covered - Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs, batteries, and other expendable items are not covered by this warranty. Unauthorized service or modification of the product or of any furnished component will void this warranty in its entirety. This warranty does not include reimbursement for inconvenience, installation, setup time, loss of use, unauthorized service, or return shipping charges.

This warranty covers only HeathCo LLC assembled products and is not extended to other equipment and components that a customer uses in conjunction with our products.

THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY,

REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY PARTICULAR PURPOSE OR USE, AND SPECIFICALLY IN LIEU OF ALL SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES.

REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY ON THE PART OF HeathCo LLC FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROFITS, WHETHER OR NOT FORESEEABLE. Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Please keep your dated sales receipt, it is required for all warranty requests.

598-1128-03

Loading...
+ 8 hidden pages