Motion Sensing
Halogen Fixture
Model SL-5525
Features
•Turns on lighting when motion is detected.
•Automatically turns lighting off.
•Photocell keeps the lighting off during daylight hours.
•LED indicates motion was sensed (day or night).
This package includes:
Plastic Hanger
6 Screws |
Gasket |
|
(3 sizes included) |
||
|
||
1 Halogen |
|
|
Lamp |
|
|
Sensor |
|
|
3 Wire |
|
|
Connectors |
|
|
Mounting Strap Light Control |
||
Mounting Bolt |
|
|
Light Shield |
Rubber Plug |
|
|
Requirements
•The Light Control requires 120-volts AC.
•If you want to use Manual Mode, the control must be wired through a switch.
•Some codes require installation by a qualified electrician.
•This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations.
© 2004 DESA Specialty Products™
OPERATION
Mode: |
On-Time: |
Works: Day |
Night |
|
|
|
|
Test |
5 Sec |
x |
x |
Auto |
1, 5, 10 min. |
|
x |
Manual |
Until Dawn* |
|
x |
|
|
|
|
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1 1/2 minutes for the circuitry to calibrate.
TEST
Put the ON-TIME switch on the bottom ON-TIME of the sensor in the TEST position.
10 5 1 TEST
AUTO
ON-TIME
Put the ON-TIME switch in the 1, 5,
or 10 minute position.
10 5 1 TEST
MANUAL MODE
Manual mode only works at night because daylight returns the sensor to AUTO.
Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.
Manual mode works only with the ON-TIME switch in the 1, 5, or 10 position.
1 Second OFF
then...
|
|
|
|
|
|
|
... back on. |
|
|
|
|
|
|
|
|
|
Mode Switch Summary |
||||||
|
|
|
|
|
|
||
|
TEST |
|
|
|
Move ON-TIME Switch to |
||
|
|
|
|||||
|
|
|
|
|
|
1, 5, or 10 minutes |
|
|
|
|
|
|
|
|
|
|
AUTO |
|
|
|
|
|
Flip light switch off |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
for one second |
|
|
|
|
|
|
|
then back on* |
|
|
|
|
|
|
|
MANUAL MODE
*If you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time the control will be in the AUTO mode.
595-5295-11
INSTALLATION
For easy installation, select an existing light with a wall switch for replacement.
For best performance, mount the fixture about 8 ft. (2.4 m) above the ground.
CAUTION: To Avoid Fire Or Burn Hazards:
•Allow fixture to cool before touching. The bulb and the fixture operate at high temperatures.
•Keep fixture at least 1" (2.5 cm) from combustible materials. Do not aim at objects closer than 3 ft. (1 m).
•Use only T3, 250W (max.) tungsten halogen 120 VAC lamps.
Note the position of the various parts of the fixture for the type of installation for your application and adjust the lamp head and sensor as shown below.
Wall Mount |
Eave Mount |
Lens Retainer
Light Shield, with opening at this side
Lens Retainer
For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock. Also for proper under eave operation, remove the protective backingfromtheLightShieldandstickonasshownbelow.
For eave mount only:
Swing the sensor head towards the clamp screw
joint. |
Controls |
|
|
|
Clamp Screw |
Then rotate the sensor head clockwise 180° so the controls face down.
Controls
Light Shield
Opening
Controls
If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.
BULB INSTALLATION.
When relamping, turn power off and let the fixture cool.
Remove glass cover and remove the old bulb by pushing the bulb towards the socket indicated on the metal reflector.
To insert the new bulb, follow the instructions printed on the metal reflector.
Check that the bulb is seated properly.
Reinstall the glass cover.
WIRE THE LIGHT CONTROL.
Turn the power to the lighting circuit off at the fuse or circuit breaker box.
Remove the existing light fixture.
Install mounting strap to junction box using screws appropriate for your junction box.
The plastic hanger can be used to hold the fixture while wiring. The small end of the plastic hanger can be threaded through the hole in the center of the cover plate. The small end then goes into one of the slots on the mounting strap.
Thread all fixture wires through the large holes in the gasket as shown.
Connect the junction box wires to the light fixture wires as shown. Twist together and secure with wire connectors.
Mounting Strap |
|
Black to Black |
White to White |
|
Rubber |
|
Plug |
Mounting
Bolt
Gasket
Connect any fixture ground wire(s) and the cover plate ground screw to the junction box ground wire.
MOUNT THE LIGHT CONTROL.
Align the Light Control cover plate and cover plate gasket. Secure with the mounting bolt.
Push the Rubber Plug firmly into place.
If a wet location junction box was not used, caulk the wall plate mounting surface with silicone weather sealant.
2 |
595-5295-11 |
TEST AND ADJUSTMENT
Turn on the circuit breaker and light switch.
NOTE: Sensor has about 1 1/2 minutes warm up period before it will detect motion. When first turned on, wait about 1 1/2 minutes.
Turn the RANGE control to the mid position and the ON-TIME control to the TEST position.
ON-TIME |
RANGE |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
10 5 1 TEST
MIN MAX
Bottom of Sensor
Avoid aiming the control at:
•Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.
•Areas where pets or traffic may trigger the control.
•Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.
180°
8 ft.
(2.4 m)
70 ft.
(21 m)
Maximum Range |
Maximum |
|
Coverage Angle |
The detector is most sensitive to motion across its field of view.
Motion
Motion
Loosen the clamp screw in |
Clamp |
|
the sensor ball joint and gen- |
||
Screw |
||
tly rotate the sensor. |
||
|
||
Walk through the coverage |
Ball |
|
area noting where you are |
||
Joint |
||
when the lights turn on (also, |
||
|
||
theLEDwillflashseveraltimes |
|
|
when motion is detected). |
|
|
Move the sensor head up, |
|
|
down, or sideways to change |
Aim Sensor |
|
the coverage area. Keep the |
Down for Short |
|
sensor at least 1" (2.5 cm) |
||
Coverage |
||
away from the lamp. |
||
|
Adjust the RANGE as needed.RANGEsettoohigh mayincreasefalsetriggering.
Secure the sensor head by tightening the clamp screw. Do not overtighten the screw.
Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 10 minutes).
SPECIFICATIONS
Range . . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with surrounding temperature].
Sensing Angle . . . . . . . Up to 180°
Electrical Load . . . . . . . Up to 250 Watts Maximum Incandescent.
Power Requirements. . 120 VAC, 60 Hz
Operating Modes . . . . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . . . 1, 5, 10 minutes Replacement lamp . . . T3, 250W (or less) halogen
120 VAC
DESA Specialty Products™ reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.
|
Sensor |
Least Sensitive |
Most Sensitive |
595-5295-11 |
3 |
TROUBLESHOOTING GUIDE
SYMPTOM |
POSSIBLE CAUSE |
|
|
|
|
Light will not |
1. |
Light switch is turned off. |
come on. |
2. |
Bulb is loose or burned out. |
|
3. |
Fuse is blown or circuit breaker is |
|
|
turned off. |
|
4. |
Daylight turn-off is in effect (recheck |
|
|
after dark). |
|
5. |
Incorrect circuit wiring, if this is a |
|
|
new installation. |
|
6. |
Re-aim the sensor to cover desired |
|
|
area. |
|
|
|
Light comes on |
1. |
Light control may be installed in a |
in daylight. |
|
relatively dark location. |
|
2. |
Light control is in test. (Set control |
|
|
switch to an ON-TIME position.) |
|
|
|
Light comes on |
1. |
Light control may be sensing small |
for no apparent |
|
animals or automobile traffic (re- |
reason. |
|
aim sensor). |
|
2. |
Sensitivity is set too high. (Reduce |
|
|
sensitivity.) |
|
|
|
Lights flash |
1. |
Sensor is detecting its own light. |
once, then stay |
|
(Reposition lamp to keep area be- |
off in Manual |
|
low the sensor relatively dark.) |
Mode. |
|
|
|
|
|
SYMPTOM |
POSSIBLE CAUSE |
|
|
|
|
Light stays on |
1. The lamp is positioned too close to |
|
continuously. |
|
the sensor or pointed at nearby ob- |
|
|
jects that cause heat to trigger the |
|
|
sensor. (Reposition the lamp away |
|
|
from the sensor or nearby objects.) |
|
2. |
Sensor is pointed toward a heat |
|
|
source like an air vent, dryer vent, or |
|
|
brightly-painted heat-reflective sur- |
|
|
face. (Reposition sensor.) |
|
3. |
Control is in Manual Mode. (Set to |
|
|
Auto.) |
|
|
|
Light flashes |
1. |
Heat or light from the lamp may be |
on and off. |
|
turning the Light Control on and off. |
|
|
(Reposition the lamp away from the |
|
|
sensor.) |
|
2. |
Heat being reflected from other ob- |
|
|
jects may be affecting the sensor. |
|
|
(Reposition sensor.) |
|
3. |
Light Control is in the Test mode and |
|
|
warming up. (Flashing is normal un- |
|
|
der these conditions). |
|
4. |
If eave installation, Light Shield not |
|
|
installed properly. (Install Light Shield |
|
|
according to instructions.) |
|
|
|
TECHNICAL SERVICE
Please call 1-800-858-8501 for assistance before returning product to store.
If you experience a problem, follow this guide. You may also want to visit our Web site at: www.desatech.com. If the problem persists, call* for assistance at 1-800-858-8501, 7:30 AM to 4:30 PM CST (M-F). You may also write* to: DESA Specialty Products™
ATTN: Technical Service Specialty Products P.O. Box 90004, Bowling Green, KY 42102-9004
* If contacting Technical Service, please have the following information available: Model Number, Date of Purchase, and Place of Purchase.
No Service Parts Available for this Product
TEN YEAR LIMITED WARRANTY
This is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary from state to state or province to province.
For a period of ten years from the date of purchase, any malfunction caused by factory defective parts or workmanship will be corrected at no charge to you.
Not Covered - Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs, batteries, and other expendable items are not covered by this warranty. Unauthorized service or modification of the product or of any furnished component will void this warranty in its entirety. This warranty does not include reimbursement for inconvenience, installation, setup time, loss of use, unauthorized service, or return shipping charges.
This warranty covers only DESA Specialty Products™ assembled products and is not extended to other equipment and components that a customer uses in conjunction with our products.
THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WAR-
RANTY, REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY
PARTICULAR PURPOSE OR USE, AND SPECIFICALLY IN LIEU OF ALL SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES.
REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY ON THE PART OF DESA SPECIALTY PRODUCTS™ FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROFITS, WHETHER OR NOT FORESEEABLE. Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Proof of purchase is required for warranty claims.
4 |
595-5295-11 |