Hanna Instruments HI 84184 User Manual

Instruction Manual
HI 84184
ISE Fluoride
Meter
www.hannainst.com
1
information for the correct use of the instrument. Please read it carefully before using the meter. If you need additional technical information, do not hesitate to e-mail us at tech@hannainst.com.
This instrument is in compliance with
directives.
TABLE OF CONTENTS
PRELIMINARY EXAMINATION................................................................................................. 3
GENERAL DESCRIPTION ........................................................................................................ 3
SPECIFICATIONS................................................................................................................... 4
PRINCIPLE OF OPERATION .................................................................................................... 4
FUNCTIONAL DESCRIPTION................................................................................................... 5
START UP ............................................................................................................................ 6
GUIDE TO DISPLAY CODES ..................................................................................................... 6
TIPS FOR AN ACCURATE MEASUREMENT ............................................................................. 13
MEASUREMENT PROCEDURE .............................................................................................. 13
FUSE REPLACEMENT .......................................................................................................... 15
ELECTRODE CONDITIONING AND MAINTENANCE .................................................................. 15
ACCESSORIES .....................................................................................................................18
WARRANTY........................................................................................................................19
MODEL IDENTIFICATION
Two models are available:
HI 84184-01 - 115 Vac power supply HI 84184-02 - 230 Vac power supply
WARRA (NTY
All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner, Hanna Instruments Inc., Woonsocket, Rhode Island, 02895 , USA.
2
PRELIMINARY EXAMINATION
Please examine this product carefully. Make sure that the instrument is not damaged. If any damage occured during shipment, please notify your Dealer.
Each HI 84184 instrument is supplied complete with:
• Reagents set for 20 tests
• One 1000 µL automatic pipette
• Four plastic tips for the 1000 µL automatic pipette
• Two 50 mL beakers
• Two 20 mL beakers
HI 61010 Fluoride half cell
HI 5315 Reference half cell
HI 7662-T Temperature probe
• Stir bar (2 pcs.)
• Power cable
HI 7075 Refilling solution (4×30 mL)
• One 1 mL syringe
• One 1 mL pipette
• Instruction sheet
• Instruction manual
Note:Save all packing material until you are sure that the instrument works correctly.
Any defective item must be returned in its original packing.
GENERAL DESCRIPTION
The HI 84184 is a low cost, easy to use, fluoride ISE instrument that performs automatic analysis with all the necessary calculations assuring to the user a simple and effective interface.
The instrument comes with a powerful and effective built-in algorithm to analyse the shape of the ISE electrode response and to determine the reaction completion.
By simply pressing the Start key, the instrument performs automatic analysis, all the necessary calculations and verifications. The result is immediately displayed in convenient units, then the instrument is ready for another measurement.
SIGNIFICANCE OF USE
Fluoride ion (F-) comes from grapes used for wine and its usual concentration value varies between
0.1 and 2 mg/L. Higher levels of fluoride content in wine can derive from cryolite used by farmers as an insecticide in the vine.
The HI 84184 ISE Fluoride meter measures the fluoride content in wine using an ion selective electrode. The used method is double standard addition, and the result is readily displayed in F
3
-
mg/L (ppm).
SPECIFICATIONS
Range 0.0 to 5.0 mg/L (ppm) F Resolution 0.1 mg/L (ppm) F
-
-
Accuracy ±5% of reading (see note) Sample volume 50 mL
Temperature Compensation Automatic from 0 to 80 °C Electrodes HI 61010 Fluoride half cell
HI 5315 Reference half cell Temperature Probe HI 7662-T (included) LOG feature 50 samples Stirring speed 500 rpm Environment 0 to 50 °C (32 to 122 °F); max 95% RH non-condensing Power supply 220V/50Hz; 10VA Dimensions 208 x 214 x 163 mm (8.2 x 8.4 x 6.4") (with beaker) Weight 2200 g (77.6 oz.)
Note: Above 3 mg/L the instrument process information about the approximate fluoride content.
REQUIRED REAGENTS Code Description Quantity/Test HI 84184-0 TISAB W/5 10 mL HI 84184-1 Standard 1 1 mL HI 84184-2 Standard 2 1 mL
PRINCIPLE OF OPERATION
The determination of fluoride concentration is made according to double standard addition method. This technique enables an unknown concentration and the electrode’s slope factor to be determined simultaneously.
The Automatic Temperature compensation is available using HI 7662-T temperature probe. By setting the electrode isopotential point and enabling temperature compensation option in Setup menu, the obtained concentration is temperature compensated.
The accuracy of the obtained result depends on the stability of the mV reading in every step of the measurement.
Three selectable stability criteria can be selected in Setup menu. Select Medium or Accurate criteria in order to have accurate analysis.
4
FUNCTIONAL DESCRIPTION
INSTRUMENT DESCRIPTION
FRONT PANEL
1) Graphic LCD
2) Functional keys
3) Keypad
4) Electrode holder
REAR PANEL
5) Fluoride half cell 10) Temperature probe socket
6) Reference half cell 11) BNC electrode connector
7) Temperature probe 12) Power switch
8) Electrode holder 13) Fuse
9) Reference socket 14) Power cable connector
5
KEYPAD DESCRIPTION
1) ESC - to leave the current screen and to return either to the previous screen or to the
main screen. In the setup parameter modifying mode by pressing ESC the value is not modified.
2)
3) HELP - to access/leave the instrument’s contextual help
4)
5) Functional Keys
- to modify a parameter value, to scroll the information from the instrument’s setup
- to modify a parameter value, to scroll the information from the instrument’s setup
START UP
• Place the instrument on a flat table. Do not place the instrument in direct sunlight.
• Connect the instrument to mains socket with ground connection and the correct voltage and
frequency. See the label on the instrument rear for this.
• Connect the HI 61010 fluoride half cell, the HI 5315 reference half cell and the HI 7662-T
temperature probe.
• Turn the instrument ON using the power switch from the rear panel of the instrument and
wait until main screen is displayed.
GUIDE TO DISPLAY CODES
During the instrument’s operation a series of information is displayed on the LCD.
1) current time information area
2) instrument status area
3) functional keys area
4) stability criteria
5) stirrer and reading status area
6
Loading...
+ 14 hidden pages