HI 150 Series
Thermometers
Manufactors since 1978
Dear Customer,
Thank you for choosing a Hanna product. This manual will
provide you with the necessary information for correct operation. Please read it carefully before using the meter. If you
need additional technical information, do not hesitate to email us at tech@hannainst.com.
These instruments are in compliance with the directives.
PRELIMINARY EXAMINATIONPRELIMINARY EXAMINATION
PRELIMINARY EXAMINATION
PRELIMINARY EXAMINATIONPRELIMINARY EXAMINATION
Remove the instrument from the packing material
and examine it carefully. If any damage has occurred during shipment, immediately notify your
Dealer or the nearest Hanna Customer Service Center.
The meters are supplied with 12 VDC power adapter.
Note: Conserve all packing material until the in-
strument has been observed to function
correctly because any defective item must be
returned in its original packing.
These Instruments are in
Compliance with the CE
Directives
HI 150 is an indicator with a relay Output and
built-in LED Alarm Signal for the monitoring of
temperature.
Constructed in a compact casing and with a molded
eye, HI 150 can be installed on the QC bench or
wherever necessary to control the ambient temperature of food chain, from the storage room to
the point of delivery.
The housing has been completely sealed against
vapors and humidity.
The measurement range is from -20 to 60ºC with
an excellent ±0.5ºC accuracy. The stainless steel
encapsulated sensor is positioned right on the
outer body of this thermometer to provide a rapid
response.
In order to ensure that temperature control is
never interrupted, HI 150 runs permanently on a
12 VDC power supply. Temperature is constantly
displayed on a large LCD so that the operator can
check it at any time.
HI 150 also offers a unique alarm control. Any
value from 0 to 50.0ºC (HI 150-00) or -20 to
20ºC (HI 150-10) can be adjusted as the setpoint
through a trimmer located on the back of the
meter. Should the temperature vary from this userselectable setpoint, the red LED blinks and the
relay is activated to warn of an abnormality or
switch on a system. The built-in LED is well visible
from a distance.
This alarm relay is a cost-saving feature with a
tremendous potential that can help you in automating your temperature control. It can also be
used as a forewarning that the refrigeration or air
conditioning unit is malfunctioning, or that a door
has been left open, or point to any other mishaps,
common in a busy workplace.
HI 150 is a convenient and inexpensive way to
ensure that temperature never varies too much
from acceptable levels. It frees workers from having to manually check the temperature and
immediately signals if and when an abnormality
arises.
HI150-00HI150-00
HI150-00
HI150-00HI150-00
Range -20.0 to 60.0ºC
Resolution 0.1ºC
Accuracy ±0.5ºC
Setpoint Selectable from 0.0 to 50.0 ºC
Hysteresis ±0.5ºC around setpoint
Alarm LED blinks and alarm relay activated
when measured temperature is
lower than the setpoint
Relay Through contacts inside the meter
Sensor Incorporated, encapsulated stainless
steel
Environment -20 to 60ºC; RH 100%
Power supply External 12 VDC (included)
Dimensions 86 x 94 x 33mm (3.4 x 3.7 x 1.3”)
Weight 150g (5.2oz.)
HI150-10HI150-10
HI150-10
HI150-10HI150-10
Range -20.0 to 60.0ºC
Resolution 0.1ºC
Accuracy ±0.5ºC
Setpoint Selectable from -20.0 to 20.0 ºC
Hysteresis ±0.5ºC around setpoint
Alarm LED blinks and alarm relay activated
when measured temperature is
higher than the setpoint
Relay Through contacts inside the meter
Sensor Incorporated, encapsulated stainless
steel
Environment -20 to 60ºC; RH 100%
Power supply External 12 VDC (included)
Dimensions 86 x 94 x 33 mm (3.4 x 3.7 x 1.3”)
Weight 150g (5.2oz.)
1. Molded eye
2. Alarm LED
3. Access for relay contacts
4. 12VDC power adapter
(included)
5. Power supply connector
6. Sensor
7. Liquid Cristal Display
OPERATIONAL GUIDEOPERATIONAL GUIDE
OPERATIONAL GUIDE
OPERATIONAL GUIDEOPERATIONAL GUIDE
TAKING MEASUREMENTS
• Turn the meter on by connecting the 12 VDC
power adapter to the meter and to the mains.
• A value will appear on the LCD to indicate the
temperature. Wait for a few minutes for the
display to stabilize.
ADJUSTING THE SETPOINT
With the HI 150, you can select your own setpoint
and be alerted with a visual LED alarm when an
abnormal situation arises.
• Unscrew and remove the rear panel and gasket
seal to access the MEASURE/SET switch.
• Move the switch to the left (SET Mode).
• With a small
screwdriver adjust the setpoint trimmer to display the desired value in the 0 to 50 ºC or -20
to 20ºC range (based on the model).
• Make sure the switch is moved back to the right
(MEASURE Mode).
RELAY CONNECTIONRELAY CONNECTION
RELAY CONNECTION
RELAY CONNECTIONRELAY CONNECTION
• To utilize the relay function open the casing as
explained for setpoint calibration.
After wiring close the casing properly. The relay
wires should pass through the access hole.
• Whenever the temperature reading reaches the
setpoint ( considering the hysteresis ), the alarm
LED blinks and relay is activated.
Recommendations for Users
Before using these products, make sure that they are entirely suitable
for the environment in which they are used.
Operation of these instruments in residential areas could cause unacceptable interferences to radio and TV equipment.
The metal band at the end of the probe is sensitive to electrostatic discharges. Avoid touching this metal band at all times.
During operation, ESD wrist straps should be worn to avoid possible damage to the probe by electrostatic discharges.
Any variation introduced by the user to the supplied equipment may degrade the instrument’s EMC performance.
To avoid electrical shock, do not use these instruments when voltages at the
measurement surface exceed 24 VAC or 60 VDC.
Use plastic beakers to minimize any EMC interferences.
To avoid damages or burns, do not perform any measurement in micro-
wave ovens.
CE DECLARATIONCE DECLARATION
CE DECLARATION
CE DECLARATIONCE DECLARATION
OF CONFORMITYOF CONFORMITY
OF CONFORMITY
OF CONFORMITYOF CONFORMITY
WARRANTYWARRANTY
WARRANTY
WARRANTYWARRANTY
HI 150-00/10 thermometer is warranted for one year
against defects in workmanship and materials when
used for their intended purpose and maintained according to instructions. The sensor are warranted for a
period of one year also. This warranty is limited to
repair or replacement free of charge.
Damages due to accident, misuse, tampering or lack
of prescribed maintenance are not covered.
If service is required, contact the dealer from whom
you purchased the instrument. If under warranty, report
the model number, date of purchase, serial number
and the nature of the failure. If the repair is not
covered by the warranty, you will be notified of the
charges incurred. If the instrument is to be returned to
Hanna Instruments, first obtain a Returned Goods
Authorization Number from the Customer Service department and then send it with shipment costs prepaid.
When shipping any instrument, make sure it is properly packaged for complete protection.
To validate your warranty, fill out and return the
enclosed warranty card within 14 days from the date of
purchase.
All rights are reserved. Reproduction in whole or in
part is prohibited without the written consent of the
copyright owner, Hanna Instruments Inc., Woonsocket,
Rhode Island, 02895 , USA.
• Replace the rear panel and the gasket, ensuring
the unit is properly closed.
Hanna Instruments reserves the right to modify the
design, construction and appearance of its products
without advance notice.
http://www.hannainst.com
ISTRHI150R2 02/2000