Instruction Manual
HI147-00
HI147-01
Check-fridge thermometers
http://www.hannainst.com
These Instruments are in
Compliance with the CE Directives
Dear Customer,
Thank you for choosing a Hanna product. This manual will
provide you with the necessary information for the correct
operation of the meter. Please read it carefully before using
the meter. If you need additional technical information, do
not hesitate to e-mail us at tech@hannainst.com.
These instruments are in compliance with the
PRELIMINARY EXAMINATIONPRELIMINARY EXAMINATION
PRELIMINARY EXAMINATION
PRELIMINARY EXAMINATIONPRELIMINARY EXAMINATION
Remove the instrument from the packing material and examine it carefully. If any damage has occurred during
shipment, immediately notify your Dealer or the nearest
Hanna Customer Service Center.
The meters are supplied with 1 x 1.5V AAA battery.
Note: Conserve all packing material until the instrument has
been observed to function correctly. Any defective item
must be returned in its original packing.
Hanna Instruments reserves the right to modify the design, construction
and appearance of its products without advance notice.
directives.
GENERAL DESCRIPTIONGENERAL DESCRIPTION
GENERAL DESCRIPTION
GENERAL DESCRIPTIONGENERAL DESCRIPTION
These thermometers are specially designed with a food compatible silicone cable, and can be used for continuous
monitoring of temperature in food care areas.
Simply attach the meter to outside a fridge or metal cabinet.
This is possible thanks to the two magnets located on the
back of the unit. The probe can then be inserted inside the
cabinet or fridge for continuous temperature monitoring.
A switch allows a rapid check of the meter calibration at any
time.
Two models are available:
• HI 147-00 displays temperatures in Centigrade degrees
• HI 147-01 displays temperatures in Fahrenheit degrees.
FUNCTIONAL DESCRIPTIONFUNCTIONAL DESCRIPTION
FUNCTIONAL DESCRIPTION
FUNCTIONAL DESCRIPTIONFUNCTIONAL DESCRIPTION
1. Liquid Crystal Display (LCD)
2. ON/OFF switch
3. Food compatible silicone cable
4. Temperature probe
5. TEST/READ switch
SPECIFICATIONSSPECIFICATIONS
SPECIFICATIONS
SPECIFICATIONSSPECIFICATIONS
HI 147-00
Range -50.0 to +150.0°C
Resolution 0.1°C
(@25ºC/77ºF) ±0.3°C (-20 to 90°C)
Accuracy
±0.5°C (outside)
Typical EMC Deviation ±0.5°C
HI 147-01
Range -58.0 to +302°F
Resolution 0.1°F (-58.0 to 199.9°F), 1°F (200 to 302°F)
(@25ºC/77ºF) ±0.5°F (-4 to 194°F)
Accuracy
±1°F (outside)
Typical EMC Deviation ±1°F
Common specifications
Probe Stainless steel probe with 1m silicone cable
Battery Type/Life 1 x 1.5V AAA
typical 3 years of continuous use
Dimensions 93 x 39 x 31mm (3.7 x 1.5 x 1.2”)
Weight 60g (2.1oz)
OPERATIONAL GUIDEOPERATIONAL GUIDE
OPERATIONAL GUIDE
OPERATIONAL GUIDEOPERATIONAL GUIDE
TAKING MEASUREMENTS
• Turn the meter ON and select READ on the TEST/READ
switch.
• The temperature value will be displayed on the LCD.
• Wait for a few seconds for the reading to stabilize.
CALIBRATION CHECK
Select TEST on the TEST/READ switch. If the meter is calibrated, the display will stabilize and show “0.0” (HI 147-00)
or “32.0” (HI 147-0) in a few seconds. To return to measurement mode, move the TEST/READ switch back to READ.
Contact your dealer or your nearest Hanna Service Center for
recalibration, if necessary.
Notes:Notes:
Notes:
Notes:Notes:
• Do NOT wrench the probe or put heavy objects on the
cable. If the cable is damaged, the meter
needs to be
replaced.
• Variations in readings or fading display can indicate a low
battery level.
BATTERY REPLACEMENTBATTERY REPLACEMENT
BATTERY REPLACEMENT
BATTERY REPLACEMENTBATTERY REPLACEMENT
When the display fades, remove the two screws on the back.
Remove the cover and replace the 1.5V AAA battery while
paying attention to its polarity.
Replace the cover and tighten the two screws.
Battery should be replaced only in a safe area using the
battery type specified in this instruction sheet.
CE DECLARATION OF CONFORMITYCE DECLARATION OF CONFORMITY
CE DECLARATION OF CONFORMITY
CE DECLARATION OF CONFORMITYCE DECLARATION OF CONFORMITY
Recommendations for Users
Before using these products, make sure
that they are entirely suitable for the
environment in which they are used. Operation of these instruments in residential
areas could cause unacceptable interferences to radio and TV equipment. Any
variation introduced by the user to the
supplied equipment may degrade the
instrument’s EMC performance. To avoid
electrical shock, do not use these instruments when voltages at the measurement surface exceed 24 VAC or 60 VDC.
To avoid damages or burns, do not perform any measurement in microwave ovens.
WARRANTYWARRANTY
WARRANTY
WARRANTYWARRANTY
HI 147-00 and HI 147-01 are warranted for one year against defects in workmanship and
materials when used for its intended purpose and maintained according to instructions. This
warranty is limited to repair or replacement free of charge.
Damages due to accident, misuse, tampering or lack of prescribed maintenance are not covered.
If service is required, contact the dealer from whom you purchased the instrument. If under warranty,
report the model number, date of purchase, serial number and the nature of the failure. If the repair
is not covered by the warranty, you will be notified of the charges incurred. If the instrument is to be
returned to Hanna Instruments, first obtain a Returned Goods Authorization Number from the
Customer Service department and then send it with shipment costs prepaid. When shipping any
instrument, make sure it is properly packaged for complete protection.
To validate your warranty, fill out and return the enclosed warranty card within 14 days from the
date of purchase.
All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of
the copyright owner, Hanna Instruments Inc., Woonsocket, Rhode Island, 02895 , USA.
09/2000 - R1