SAFETY INFORMATION
WARNING
•
Use this appliance only for its intended purpose as
described in this Owner’s Manual.
•
This air conditioner must be properly installed in accordance
with the Installation Instructions before it is used.
•
Never unplug your air conditioner by pulling on the power
cord. Always grip plug firmly and pull straight out from the
receptacle.
•
Replace immediately all electric service cords that have
become frayed or otherwise damaged. A damaged power
supply cord must be replaced with a new power supply
cord obtained from the manufacturer and not repaired.
Do not use a cord that shows cracks or abrasion damage
along its length or at either the plug or connector end.
•
Turn the unit OFF and unplug your air conditioner before
cleaning.
WARNING
RISK OF FIRE. Could cause serious injury or death.
•
DO NOT use an extension cord with this Window Air
Conditioner.
For your safety, the information in this manual must be followed to minimize the risk of fire, electric
shock or personal injury.
USE OF EXTENSION CORDS
•
GE Appliances does not support any servicing of the air
conditioner. We strongly recommend that you do not
attempt to service the air conditioner yourself.
•
For your safety…do not store or use combustible
materials, gasoline or other flammable vapors or liquids in
the vicinity of this or any other appliance.
•
All air conditioners contain refrigerants, which under federal
law must be removed prior to product disposal. If you are
getting rid of an old product with refrigerants, check with
the company handling disposal about what to do.
•
If the receptacle does not match the plug, the receptacle
must be changed out by a qualified electrician.
•These R410A air conditioning systems require
contractors and technicians to use tools, equipment and
safety standards approved for use with this refrigerant.
DO NOT use equipment certified for R22 refrigerant
only.
•
DO NOT use surge protectors or multi-outlet adaptors
with this Window Air Conditioner.
HOW TO CONNECT ELECTRICITY
Do not, under any circumstances, cut or remove the third
(ground) prong from the power cord. For personal safety, this
appliance must be properly grounded.
DO NOT use an adapter plug with this appliance.
The power cord of this appliance is equipped with a 3-prong
(grounding) plug which mates with a standard 3-prong
(grounding) wall outlet to minimize the possibility of electric
shock hazard from this appliance.
Power cord includes a current interrupter device. A test
and reset button is provided on the plug case. The device
should be tested on a periodic basis by first pressing the
TESTешччтсдсзчлисчлиRESETешччтсълмпиупшккизinto the outlet. If the TESTешччтсзтицстччхмутхмйчли
RESETешччтсъмппстчцчдьискдкиззмцжтсчмсшишцитйчлидмх
conditioner and contact a qualified service technician.
WARNING
•
This product contains a lithium button/coin cell battery.
If a new or used lithium button/coin cell battery is
swallowed or enters the body, it can cause severe
internal burns and can lead to death in as little as 2 hours.
Always completely secure the battery compartment. If
the battery compartment does not close securely, stop
using the product, remove the batteries, and keep it
away from children.
Chemical Burn Hazard. Keep batteries away from children.
Have the wall outlet and circuit checked by a qualified
electrician to make sure the outlet is properly grounded.
Where a 2-prong wall outlet is encountered, it is your
personal responsibility and obligation to have it replaced with
a properly grounded 3-prong wall outlet.
The air conditioner should always be plugged into its own
individual electrical outlet which has a voltage rating that
matches the rating plate.
This provides the best performance and also prevents
overloading house wiring circuits which could cause a fire
hazard from overheated wires.
See the Installation Instructions, Electrical Requirements
section for specific electrical connection requirements.
•
If you think batteries might have been swallowed or placed
inside any part of the body, seek immediate medical
attention.
•
The cells shall be disposed of properly, including keeping
them away from children.
• Even used cells may cause injury.
449-7827-2
READ AND SAVE THESE INSTRUCTIONS
CONTROLS
ENGLISH
Features and appearance will vary.
Lights beside the touch pads on the air conditioner control panel
indicate the selected settings.
1234
MODE
SPEED
COOL
FAN ECO
AUTO
LOW
MED
HIGH
5
87
FILTER
WIFI
9
Air Conditioner Controls
1. Power Pad
Turns air conditioner on and off. When turned on, the
display will show the room temperature.
2. Display
Shows the room temperature or time remaining on the
Delay timer. Shows the Set temperature while setting the
temperature in Cool or Eco modes.
3. Temp and Delay Increase ޔ /Decrease ޕ Pads
Use to set temperature or delay time. Temperature can be
set in Cool and Eco mode.
4. Mode Pad
Use to set the air conditioner to Fan Only, Cool, or Eco
mode.
5. Fan Speed Pad
In Cool or Eco mode: Use to set the fan speed to Auto,
High, Med or Low on the unit.
In Fan Only mode: Use to set the fan speed to High, Med,
or Low on the unit.
6. Delay Pad (set by remote control only)
Delay ON—When the air conditioner is off, it can be set
to automatically come on in 1 to 24 hours at its previous
mode and fan settings.
Delay OFF—When the air conditioner is on, it can be set to
automatically turn off in 1 to 24 hours.
How to set:
Press the Delay pad on the remote control. Each touch of
the Increase ޔ / Decrease ޕ pads on the remote control will
set the timer in 1-hour intervals.
To review the remaining time on the Delay timer, press
the Delay pad on the remote control. Use the Increase ޔ /
Decrease ޕ pads on the remote control to set a new time if
desired.
To cancel the timer, press Decrease ޕ pad on the remote
control until the set time is zero.
ON/OFF
MODE
SPEED
DELAY
TEMP/TIME
TEMP/TIME
SLEEP
Solid light indicates WiFi
connected
Blinking light indicates
connecting
See Appliance Communication
section in this manual
1
4
5
6
3
Remote Control
7. Sleep Pad (set by air conditioner controls only)
The SLEEP mode sets the unit to gradually change
settings over an 8 hour period to allow for some
increased energy efficiency during sleep hours.
The SLEEP mode is available only in COOL and FAN only
settings.
Press the SLEEP mode pad and its light will illuminate.
The fan indicator will stay at the same setting but the air
conditioner will automatically change the FAN speed to
low in either COOL or FAN only mode.
In FA N only mode, the fan will stay in the LOW speed
setting for 8 hours. After 8 hours, the air conditioner will
resume the settings that were in place before the SLEEP
mode pad was pressed.
In COOL mode, the fan will stay in the LOW speed
setting for 8 hours from the time the SLEEP mode pad
was pressed. The air conditioner will also raise the set
point 2°F in 30 minutes and 2°F more in another 30
minutes where it will remain for the next 7 hours. After 8
hours, the air conditioner will resume the settings that
were in place before the SLEEP mode pad was pressed.
While the unit is in SLEEP mode, pressing any pad will
return it to the settings that were in place before the
SLEEP mode pad was pressed.
8. Filter Reset Pad
This feature automatically notifies you that the air filter
must be cleaned. The indicator light will come on after 240
hours of operation. Clean the air filter (refer to page 6),
place it back in the front panel, and press the Filter Reset
pad. The light will go off.
9. WiFi Connect Pad
Enables connection of the air conditioner to the home
WiFi.
Download the Haier Home App
For details go to Haierappliances.com.
49-7827-25
ENGLISH
USING THE AIR CONDITIONER
Do Not Operate in Freezing Outdoor Conditions
This cool-only air conditioner was not designed for freezing
outdoor conditions.
Control Panel Lights On/Off Feature
This air conditioner has a control panel lights on/off feature
where its lights will turn off when there is no activity with the
controls for over one minute. To wake up the controls, press
any pad on the controls and the lights will come on to show
the previous settings.
Remote Control
• To ensure proper operation, aim the remote control at the
signal receiver on the air conditioner.
• The remote control signal has a range of up to 20 feet.
Cool Mode
Use the Cool mode at Low, Med, High or Speed for cooling.
Use the Temperature Increase ޔ / Decrease ޕpads to
set the desired temperature between 64°F and 86°F in 1°F
increments.
An electronic thermostat is used to maintain the room
temperature. The compressor will cycle on and off to keep
the room at the set level of comfort. Set the thermostat at a
lower number and the indoor air will become cooler. Set the
thermostat at a higher number and the indoor air will become
warmer.
It must not be used when the outdoor temperature is below
freezing (32°F).
To turn this feature off, press and hold the SLEEP pad,
on the unit, for 5 seconds. The unit will beep to signal the
successful toggle of the feature on and off.
• Make sure nothing is between the air conditioner and the
remote control that could block the signal.
• Make sure batteries are fresh and installed correctly as
indicated on the remote control.
while set to a Cool setting or if turned from a fan setting to
a Cool setting, it may take approximately 3 minutes for the
compressor to start and cooling to begin.
Cooling Descriptions
For Normal Cooling—Select the Cool mode and
High or Med fan with a middle set temperature.
For Maximum Cooling—Select the Cool mode
and High fan with a lower set temperature.
For Quieter and Nighttime Cooling—Select the
Cool mode and Low fan with a middle set temperature.
Eco Mode
Controls the fan.
ON—The fan will cycle on and off with the compressor. This
may result in wider variations of room temperature and
humidity. NOTE: the fan may continue to run for a short time
or may pulse intermittently after the compressor cycles off to
sample the room air.
OFF—The fan runs all the time, while the compressor cycles
on and off.
Fan Only Mode
Use the Fan Only Mode at Low, Med or High fan speed to
provide air circulation and filtering without cooling. Since
fan-only settings do not provide cooling, a Set temperature
cannot be entered. The room temperature will appear in the
display.
Auto Fan Mode
Set to Auto for the fan speed to automatically set to the
speed needed to provide optimum comfort settings with the
set temperature.
If the room needs more cooling, the fan speed will
automatically increase. If the room needs less cooling, the fan
speed will automatically decrease.
649-7827-2
USING THE AIR CONDITIONER
Air Direction
Use the lever to adjust the air direction left, right, up and
down.
CARE AND CLEANING
Grille and Case
Turn the air conditioner off and remove the plug from the wall
outlet before cleaning.
Air Filter
The air filter behind the front grille should be checked and
cleaned at least every 30 days or more often if necessary.
ENGLISH
To clean, use water and a mild detergent. Do not use bleach
or abrasives.
CAUTION
To remove:
Open the inlet grille by pulling downward on the tabs at the
top upper corners of the inlet grille until the grille is in a 45º
position. Remove the filter.
Clean the filter with warm, soapy water. Rinse and let the filter
dry before replacing it. Do not clean the filter in a dishwasher.
Outdoor Coils
The coils on the outdoor side of the air conditioner should be
checked regularly. If they are clogged with dirt or soot, they
may be professionally cleaned.
How to Insert the Battery in the Remote Control
1.
Remove the screw on the back of the battery cover.
2.
Pinch the slide lock and pull the battery tray out at the same
time.
3.
Insert new battery, making sure that the (+) and (–) of
battery are installed correctly.
dirt and lint will clog it and reduce performance.
NOTES:
•
Use one CR 2025 (3V) Lithium battery.
•
Remove the battery from the remote control if the system
is not going to be used for a long time.
4.
Reinsert the battery tray and reinstall the screw.
49-7827-27
ENGLISH
FOR MORE HELP, VISIT HAIERAPPLIANCES.COM OR CALL THE CONSUMER HELP LINE AT 1-877-337-3639.
INSTALLATION INSTRUCTIONS
BEFORE YOU BEGIN
Read these instructions completely and carefully.
•
IMPORTANT –Save these instructions
for local inspector’s use.
•
IMPORTANT –Observe all governing
codes and ordinances.
• Note to Installer – Be sure to leave these
instructions with the Consumer.
• Note to Consumer – Keep these instructions for
future reference.
• Skill level – Installation of this appliance requires
basic mechanical skills.
• Completion time – Approximately 1 hour
• We recommend that two people install
this product.
• Proper installation is the responsibility
of the installer.
• Product failure due to improper installation is not
covered under the Warranty.
• You MUST use all supplied parts and use proper
installation procedures as described in these
instructions when installing this air conditioner.
ELECTRICAL REQUIREMENTS (CONT)
CAUTION
Do not, under any circumstances, cut or remove the
third (ground) prong from the power cord.
Do not change the plug on the power cord of this air
conditioner.
Aluminum house wiring may present special
problems—consult a qualified electrician.
Power cord includes a current interrupter device. A
test and reset button is provided on the plug case.
The device should be tested on a periodic basis by first
pressing the TESTешччтсдсзчлисчлиRESETешччтс
while plugged into the outlet. If the TESTешччтсзтиц
not trip or if the RESETешччтсъмппстчцчдьискдкиз
discontinue use of the air conditioner and contact a
qualified service technician.
TOOLS YOU WILL NEED
ELECTRICAL REQUIREMENTS
Models QHC18 and QHC24
The 3-prong grounding plug minimizes the
possibility of electric shock hazard. If the wall
outlet you plan to use is only a 2-prong outlet,
it is your responsibility to have it replaced with a
properly grounded 3-prong wall outlet.
These models require 230/208-volt AC,
protected with a time-delay fuse or circuit breaker.
These models should be installed on their own single
branch circuit for best performance and to prevent
overloading house or apartment wiring circuits, which
could cause a possible fire hazard from overheating
wires.
Model QHC15
These models require a 115/120-volt AC,
60-Hz grounded outlet protected with a
15-amp time-delay fuse or circuit breaker.
The 3-prong grounding plug minimizes the possibility of
electric shock hazard. If the wall outlet you plan to use is
only a 2-prong outlet, it is your responsibility to have it
replaced with a properly grounded 3-prong wall outlet.
Phillips head screwdriver
Drill and 1/8” drill bit
Pencil
LevelScissors or knife
Ruler or tape measure
849-7827-2
INSTALLATION INSTRUCTIONS
ENGLISH
Top Mounting Rail
(may be installed already)
Air
Conditioner
Foam Seal
Bottom Seal and
Side Seals (6)
Side Curtain
(2)
Side Curtain
Left
Frame
Right
ON/OFF
MODE
SPEED
DELAY
Installation
Bracket (2)
Window Lock
ABCD
3/8” Self-tapping
Screws (12)
Bracket
3/8” Bracket
Screws (6)
1” Wood
Screws (8)
Side Curtain
Foam (2)
2-1/2” Flat Head Bolt and
Lock Nut (2)
TEMP/TIME
TEMP/TIME
Remote Control
49-7827-29
ENGLISH
INSTALLATION INSTRUCTIONS
!аТЧНШаЫОЪЮТЫОЦОЧЭЬ
• These instructions are for a standard double-hung
window. You will need to modify them for other
types of windows.
• The air conditioner can be installed without the
side curtain panels if needed to fit in a narrow
window. See the window opening dimensions.
• All supporting parts must be secured to firm
wood, masonry or metal.
• The electrical outlet must be within reach of the
power cord.
• Follow the dimensions in the table and illustration
for your model.
ModelsAB
QHC15
QHC18
QHC24
(With side curtain panels)
19 1/8” min30”-39”
A
B
3. PREPARE THE AIR CONDITIONER
A. Remove three screws on each side of the case. Save
the screws for use later.
B. Insert a flat head screw driver between the front
Save these screws
for later use.
grille and the metal case along the sides. Gently pry
the grille from the case.
NOTE: Cover the flat head screw driver with tape to
prevent scratching the case.
2. STORM WINDOW REQUIREMENTS
A storm window frame will not allow the air
conditioner to tilt toward the outside, and will keep
it from draining properly. To adjust for this, attach
a piece of wood to the sill.
аШШНЩТОМОЬ
WIDTH: 2ė
LENGTH: Long enough to fit inside the window
frame.
THICKNESS: To determine the thickness, place