Cautions
The machine is adaptive in following situation
I. Applicable ambient temperature range:
Indoor
Cooling
Outdoor
Indoor
Heating
Outdoor
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05RN-F or H07RN-F
3. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V.
4. The distance between the indoor unit and the floor should be more than 2m.
5. The wiring method should be in line with the local wiring standard.
6. After installation, the power plug should be easily reached.
7. The waste battery should be disposed properly.
8. The appliance is not intended to use by young children or infirm persons without supervision.
9.Young children should be supervised ensure that they do not play with the appliance.
10.The appliance must be installed on strong enough supporter.
11.The wiring diagram is attached inside the machine.
Maximum: D.B / W.B 32oC/23oC Minimum: D.B / W.B
Maximum: D.B Minimum: D.B Maximum: D.B
Minimum: D.B Maximum: D.B / W.B Minimum: D.B / W.B
18oC/14oC 43oC/26oC
18oC 27oC
15oC 24oC/18oC
-7oC/-8oC
2
Parts and Functions
Indoor Unit
Inlet grille
Air filter
Test running switch(manual)
Used only for test running in cooling when room temp. is below 16oC. Don't use it in normal operation.
Emergency switch(manual)
Used when remote controller is lost or defective. Unit will run temporarily.
Remote signal receiver
A beeping sound is generated when a signal from remote controller is received.
Vertical flap
Use remote controller to adjust up and down air flow. (Don't adjust it manually.)
Power indicator
Lights up when unit starts.
Timer mode indicator
Lights up when Timer operation is selected.
Operation mode indicator
Lights up during compressor running.
Actual inlet grille may vary from the one shown in the manual according to the product purchased
Outdoor Unit
HSU-07RE03/R2 HSU-09RE03/R2 HSU-12RE03/R2
OUTLET
INLET
HSU-18RE03/R2 HSU-22RE03/R2
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
3
Parts and Functions
Operation
1
2 3
4
11
12
13
14
15
16
17
Clock set
A U T O
ON/OFF
MODE SET
FAN
SWING
SLEEP
LOCK RESET
o
PM
C
TEMP
TIMER
CLOCK
Buttons and display of the remote controller.
1. Mode display AUTO
COOL DRY HEAT FAN
2. SWING display
3. FAN SPEED display
4. SLEEP display
5. LOCK display
6. SIGNAL SENDING
7. TIMER OFF display
8. TIMER ON display
9. CLOCK display
10. TEMP display
11. POWER ON/OFF
Used for unit start and stop.
12. MODE
Used to select AUTO run, COOL, DRY, HEAT and FAN operation
13. FAN
Used to select fan speed LO, MED, HI, AUTO
14. HOUR
Used to set clock and timer setting.
15. SWING
Used to set auto fan direction.
16. SLEEP
Used to select sleep mode.
17. LOCK
Used to lock buttons and LCD display.
18. TEMP.
Used to select your desired temp.
19. SET
Used to confirm timer and clock settings.
20. TIMER
Used to select TIMER ON, TIMER OFF, TIMER ON-OFF
21. CLOCK
Used to set correct time
22. RESET
Used to reset the controller back to
normal condition.
ON OFF
AM
5 6
7
8
9
10
18
19
20
21
22
LO MED HIAUTO
When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows: Press CLOCK button, "AM" or "PM" flashes. Press or to set correct time. Each press will increase or decrease 1min. If the button is kept depressed, time will change quickly. After time setting is confirmed, press SET, "AM "and "PM" stop flashing, while clock starts working.
NOTE: Cooling only unit do not have displays and functions related with heating
Hints
After replacing with new batteries, remote controller will conduct self-check, displaying all information on LCD. Then, it will become normal.
4
Parts and Functions
Operation
Buttons and display of the remote controller.
If the unit which you purchased has healthy function, Remote controller should
like the following figure:
1. Mode display AUTO
COOL DRY HEAT FAN
2. SWING display
3. FAN SPEED display
4. SLEEP display
5. LOCK display
6. SIGNAL SENDING
7. TIMER OFF display
8. TIMER ON display
9. CLOCK display
10. TEMP display
11. POWER ON/OFF
Used for unit start and stop.
12. MODE
Used to select AUTO run, COOL, DRY, HEAT and FAN operation
13. FAN
Used to select fan speed LO, MED, HI, AUTO
14. HOUR
Used to set clock and timer setting.
15. SWING
Used to set auto fan direction.
16. SLEEP
Used to select sleep mode.
17. LOCK
Used to lock buttons and LCD display.
18. TEMP.
Used to select your desired temp.
19. SET
Used to confirm timer and clock settings.
20. TIMER
Used to select TIMER ON, TIMER OFF, TIMER ON-OFF
21. CLOCK
Used to set correct time
22. RESET
Used to reset the controller back to
normal condition.
23. HEALTH
Used to set healthy operation
LO MED HIAUTO
11
12
13 14
15
16
17
1
ON
2 3
A U T O
OFF
AM
o
PM
C
5 6
7
8
9
4
ON/OFF TEMP
MODE SET
FAN TIMER
SWING CLOCK
SLEEP
HEALTH
LOCK RESET
10
18
19
20
21
22
BRIEF INTRODUCTION TO HEALTH OPERATION
The anion generator in the air conditioner can generate a lot of anion to effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room.
NOTE: Cooling only unit do not have displays and functions related with heating
Hints
After replacing with new batteries, remote controller will conduct self-check, displaying all information on LCD. Then, it will become normal.
5
Operation
Remote controller's operation
When in use, put the signal transmission head directly to the receiver hole on the indoor unit.
The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well.
Don't throw the controller, prevent it from being damaged. When electronic-started type fluorescent lamp or change-over
type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receivering the signals so the distance to the indoor unit should be shorter.
Loading of the battery
Load the batteries as illustrated. 2 R-03 batteries, resetting key (cylinder)
Remove the battery cover:
Slightly press " " and push down the cover.
Load the battery:
Be sure that the loading is in line with the" + "/"-" pole request as illustrated.
Put on the cover again Confirmation indicator:
In disorderation, reload the batteries or load the new batteries after 6mins.
Note:
Use two new same-typed batteries when loading. If the remote controller can't run normally or doesn't work at all, use a sharp pointed item to press the reset key.
Hint:
Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out just need to press reset key.
Power failure resume(please set and apply as necessary)
If sudden power failure occurs, the unit will resume original operation when power is supplied again.
Note:
When sudden power failure happens during unit operation in power failure resume mode, if the air conditioner is not desired for use in a long period, please shut off the power supply in case that the unit automatically resume operation when power is re-supplied, or press ON/OFF to turn off the unit when power resumes.
6
Operation
Auto run, Fan operation
Enjoy yourself by just a gentle press.
(1) Unit start
Press ON/OFF button, unit starts. Previous operation status appears on display. (Not Timer setting) Power indicator on indoor unit lights up.
(2) Select operation mode
Press MODE button. For each press, operation mode changes as follows:
AUTO COOL DRY HEAT FAN
Unit will run in selected mode. Stop display at " " AUTO or " "FAN.
(3) FAN
Press FAN button. For each press, fan speed changes as follows:
AM
ON/OFF TEMP
1
4
MODE
2
FAN
3
CLOCKSWING
SLEEP
HEALTH
LOCK
SET
TIMER
RESET
AUTO LO MED HI
Unit will run at selected fan speed. Note:AUTO is not available in FAN mode.
(4) Unit stop
Press ON/OFF button. Only time remains on LCD. All indicators on indoor unit go out. Vertical flap closed automatically.
Hints
Remote controller can memorize settings in each operation mode. To run it next time just select the operation mode and it will start with the previous setting. No reelecting is needed.(TIMER ON/OFF needs reelecting)
Cautions: Note: On cooling only unit, heating mode is not available, The above information is the
After replacing batteries, press ON/OFF, and display explanation of the displayed becomes as follows: information therefore varies Operation mode: AUTO, Temp. No with those displayed in actual Timer mode: No, Fan speed :AUTO operation.
7
Operation
COOL,HEAT and DRY operation
Recommendations:
Use COOL in summer. Use HEAT in winter Use DRY in spring, autumn and in damp climate.
(1) Unit start
Press ON/OFF button, unit starts. Previous operation status appears on display.(Not Timer setting) Power indicator on indoor unit lights up.
(2) Select operation mode
Press MODE button. For each press, operation mode changes as follows:
AUTO COOL DRY HEAT FAN
Unit will run in operation mode displayed on LCD. Stop display at your desired mode.
(3) Select temp. setting
Press TEMR button.
Every time the button is pressed, temp. setting increases 1oC Every time the button is pressed, temp. setting decreases 1oC
Unit will start running to reach the temp. setting on LCD.
o
C
ON/OFF TEMP
1
6
MODE
2
5
SLEEP
3
FAN
4
CLOCKSWING
HEALTH
AM
3
SET
TIMER
(4) Fan speed selection
Press FAN button. For each press, fan speed changes as follows:
AUTO LO MED HI
COOL operation starts when room
Unit runs at the speed displayed on LCD.
In DRY mode, when room temperature becomes lower than temp.setting+2oC,unit will run intermittently
temp. is higher than temp. setting.
Temp. setting+2oC
Temp. setting
at LOW speed regardless of FAN setting.
Hints
On cooling only unit, heating mode is not available. Remote controller can memorize each operation status. When starting it next time, just press ON/OFF button and unit will run in previous status.
LOCK
On reaching temp. setting, unit will run in mild DRY mode.
RESET
Ultra-low air flow
8
Operation
(5) Air flow direction adjustment
After operation mode is selected, vertical flap will open automatically according to the mode. Referring to the Fig.
COOL
About 10
o
Up and down (Use remote controller)
Press SWING button, vertical flap will move within the range shown in the Fig. Press SWING button stop it at a fixed position.
o
o
o
COOL
HEAT
About 10
About 45
About 60
Cautions:
It is advisable not to keep vertical flap at downward position for a long time in COOL or DRY mode, otherwise, condensate water might occur.
HEAT
About 60
o
Left and right air flow adjustment (manual)
Move the horizontal blade by a knob on air conditioner to adjust left and right direction referring to Fig.
Cautions:
When humidity is high, condensate water might occur at air outlet if all horizontal louvers are adjusted to left or right.
(6) Unit stop
Press ON/OFF button. Only time remains on LCD. All indicators on indoor unit go out. Vertical flap closes automatically.
Cautions:
Unit won't restart until 3 minutes have elapsed, due to system protection. HEAT mode is not available on cooling only unit.
Hints
As cold air flows downward in COOL mode, adjusting air flow horizontally will be much more helpful for a better air circulation. As warm air flows upward in HEAT mode, adjusting air flow downward will be much more helpful for a better air circulation. Be careful not to catch a cold when cold air blows downward. It is harmful to your health in summer to go frequently in and out of places where temp. difference is above 7oC. Temp. difference of 3-5oC will remove your fatigue. More than this, unit's load can be reduced and power consumption cut down as well. So, you'd better set a temp. difference of 3-5oC between indoor and outdoor temp. in COOL mode.
9
Operation
TIMER Operation
Set Clock correctly before starting Timer operation
You can let unit start or stop automatically at following times: Before you wake up in the morning, or get back from outside or after you fall asleep at night.
TIMER ON/OFF
(1)After unit start, select your desired operation mode. Operation mode will be displayed on LCD. Power indicator on indoor unit lights up.
(2)TIMER mode selection
Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows:
ON OFF ON OFF
TIMER ON TIMER OFF TIMER ON-OFF
blank
Select your desired TIMER mode (TIMER ON or TIMER OFF) ON or OFF will flash.
(3)Timer setting
Press HOUR / button.
Every time the button is pressed, time increases 10 min.
If button is kept depressed, time will change quickly.
Every time the button is pressed, time decreases 10 min. If button is kept depressed, time will change quickly. Time will be shown on LCD. It can be adjusted within 24 hours.
(4)Confirming your setting
After setting correct time, press SET button to confirm, "ON" or "OFF" stops flashing Time displayed: Unit starts or stops at x hour x min. (TIMER ON or TIMER OFF). Timer mode indicator on indoor unit lights up.
AM
o
C
ON/OFF TEMP
1
MODE
3
HEALTH
3
2
CLOCKSWING
FAN
SLEEP
LOCK
ON
SET
TIMER
RESET
4
To cancel TIMER mode
Just press TIMER button several times until TIMER mode disappears.
Hints
After replacing batteries or a power failure happens, Time setting should be reset.
Remote controller possesses memory function, when use TIMER mode next time, just
press SET button after mode selecting if timer setting is the same as previous one.
10
Operation
TIMER ON-OFF
(1)After unit start, select your desired operation mode Operation mode will be displayed on LCD. Power indicator on indoor unit lights up.
(2) Press TIMER button to change TIMER mode.
Every time the button is pressed, display changes as follows:
ON OFF ON OFF
TIMER ON TIMER OFF TIMER ON-OFF
blank
Select TIMER ON-OFF. "ON" will flash.
(3)Time setting for TIMER ON
Press HOUR button.
Every time the button is pressed, time increases 10 min.
If button is kept depressed, time will change quickly.
Every time the button is pressed, time decreases 10 min.
If button is kept depressed, time will change quickly.
Time will be shown on LCD. It can be adjusted within 24 hours. AM refers to morning and PM to afternoon
(4) Time confirming for TIMER ON
After time setting, press TIMER button to confirm. "ON" stops blinking, While "OFF" starts blinking. Time displayed: Unit starts at x hour x min.
(5)Time setting for TIMER OFF
Follow the same procedures in "Time setting for TIMER ON".
AM
o
C
ON/OFF TEMP
1
MODE
5
HEALTH
3
2
CLOCKSWING
FAN
SLEEP
LOCK
ON
SET
6
TIMER
4
RESET
(6) Time confirming for TIMER OFF
After time setting, press SET button to confirm, "OFF" stops flashing Time displayed: Unit stops at X hour X min.
To cancel TIMER mode
Just press TIMER button several times until TIMER mode disappears.
11
Operation
HEALTH Mode operation
(1) Press the ON/OFF switch.
(2) Press the "HEALTH" once," "
is displayed, now the air conditioner is operating the health function.
(3) Press the "HEALTH"again,then the health function stops.
A U T O
ON/OFF TEMP
MODE SET
FAN TIMER
SWING CLOCK
SLEEP
HEALTH
LOCK RESET
AM
o
C
BRIEF INTRODUCTION TO HEALTH OPERATION
The anion generator in the air conditioner can generate a lot of anion to effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room.
12
Operation
Emergency operation and test operation
Emergency Operation:
Carry out this operation only when the remote controller is defective or lost. When the emergency operation switch is pressed, a" Pi "sound starts once, which means the start of this operation. In this operation, it is not possible to change the settings of temperature and air flow speed, it is also impossible to do an operation by the timer. Follow the requirements below.
Pi
Room temperature
More than 23oC
Less than 23oC 23oC
Designated temperature
26oC
Timer mode
CONTINUOUS
CONTINUOUS
Air flow speed
AUTO
AUTO
Operation mode
COOL
HEAT
If an air conditioner is a model for both cooling and heating.
Cooling when the room temperature at the start of operation is above 23oC. Heating when the room temperature at the start of operation is below 23oC
Test operation:
Use this switch in the test operation when the room temperature is less 16oC, do not use it in the normal operation. Continue to press the test operation switch for more than 5 seconds. After you hear the "Pi" sound twice, release your finger from the switch, the cooling operation starts with the air flow speed setting "Hi".
Pi Pi
Removal of the restriction of emergency or test operation:
Press once more the emergency operation switch, or manipulate through the remote controller, a "Pi" sound causes the restriction of emergency or test operation to be removed. When the remote controller is manipulated for the removal, then the selected operation by the remote controller.
13
Operation
Comfortable SLEEP
Before going to bed at night, you can simply press the SLEEP button and unit will bring you a sound sleep in selected mode.
In COOL mode
One hour after SLEEP mode starts, temp. will become 1oC higher than temp. setting. After running for another 1 hour, temp. rises by 1oC further. Unit will run for 6 hours then stops automatically. Temp. is higher than temp. setting so that room temp. won't be too low
for your sleep.(As shown in Fig.l)
AM
ON/OFF TEMP
MODE
FAN
SLEEP
LOCK RESET
TIMER
CLOCKSWING
HEALTH
SET
In HEAT mode
One hour after SLEEP mode starts, temp. will become 2oC lower than temp. setting. After running for another 1 hour, temp. decreases by 2oC further. Unit will run for 3 hours at this temp. then increases another 1oC and stops automatically 3 hours later. Temp. is lower than temp. setting so that room temp. won't be too high for your sleep. (As shown in Fig .2)
Power Failure Resume Function
If the unit is started for the first time, the compressor will not start running unless 3 minutes have elapsed. When the power resumes after power failure, the unit will run automatically, the power indicator lights up, and 3 minutes later the compressor starts running with the indicator lighting up.
Note:
In AUTO mode, unit will run in SLEEP function according to operation mode. In FAN mode, comfortable sleep is not available.
SLEEP operation starts SLEEP operation stops
Approx. 6 hrs
1 hr
1 hr
Temp. setting Unit stop
Rises 1oC
Rises 1oC
Fig.1
Temp. setting Unit stop
1 hr
SLEEP mode starts SLEEP mode stops
decreases 2oC
1 hr
3 hrs
decreases 2oC
Approx. 3 hrs
Rises 1oC
Fig.2
14
Maintenance
Different models have different appearance
Cleaning of unit casing
Cut off power supply before cleaning unit casing with soft cloth. In case of heavy stain, clean it with neutral detergent. squeeze water in the cloth, wipe off the detergent on unit casing completely.
Cleaning of remote controller
Cleaning of air filter
1.Open inlet grille by pulling it upward.
3.Clean the filter Use a vacuum cleaner to remove dust,or wash the filter with water. After washing, dry the filter completely in the shade.
5.Close the inlet grille.
Don't use water to wash unit casing, please use dry cloth. Don't use glass cleaner or cloth soaked with chemicals.
Air Filter
2.Remove air filter Push up the filter's center tab slightly until it is caesura of the stopper. Remove it by pulling down.
4.Attach the filter Attach filter behind the stopper so that the "Front" indication is facing to the front. Make sure that it is completely behind the stopper, otherwise problems might occur.
15
Maintenance
Better use of air conditioner
Proper room temperature. Cleaning of the air filter.
Proper
temperature
Once every
two weeks
Closing of doors and windows
Effective use of the timer.
during operation
Curtains or blinds
for windows
Never fail to observe the followings
Do not sprinkle water over
the unit.
Do not block the inlet or outlet.
Avoid time-wasteful operation
Do not pull power plug. Do not use for other purposes.
Such as food preservation plant cultivation or animal breeding.
16
Trouble shooting
Before asking for service, check the following first.
Normal Performance inspection
Phenomenon
The system does not restart immediately.
Noise is heard
Smells are generated.
Mist or steam are blown out.
Cause or check points
When unit is stopped, it won't restart immediately until 3 minutes have elapsed to protect the system. When the electric plug is pulled out and reinserted, the protection circuit will work for 3 minutes to protect the air conditioner.
During unit operation or at stop, a swishing or gurgling noise may be heard. At first 2-3 minutes after unit start, this noise is more noticeable. (This noise is generated by refrigerant flowing in the system.) During unit operation, a cracking noise may be heard. This noise is generated by the casing expanding or shrinking because of temperature changes Should there be a big noise from air flow in unit operation, air filter may be too dirty.
This is because the system circulates smells from the interior air such as the smell of furniture, cigarettes.
During COOL or DRY operation, indoor unit may blow out mist. This is due to the sudden cooling of indoor air.
Does not work at all.
Multiple
check
Poor cooling
Application temp. range of air conditioner -7oC~43oC.
Is power plug inserted? Is there a power failure? Is fuse blown out?
Is the air filter dirty? Normally it should be cleaned every 15 days. Are there any obstacles before inlet and outlet? Is temperature set correctly? Are there some doors or windows left open? Is there any direct sunlight through the window during the cooling operation?(Use curtain) Are there too much heat sources or too many people in the room during cooling operation?
17
Indice
Precauciones Piezas y funciones Funcionamiento Mantenimiento Resolución de problemas
18 19-21
22-29
30-31
32
17
Precauciones
La máquina puede adaptarse a las siguientes condiciones
1. Rango aplicable de temperatura ambiente:
Interior
Refrigeración
Exterior
Interior
Calefacción
Exterior
2. Si el cable de alimentación está dañado, debe ser sustituido por el fabricante o su agente de mantenimiento o una persona con cualificación similar. El tipo de cable de conexión es H05RN-F o H07RN-F.
3. Si el fusible de la placa PC está roto, cambiarlo por uno del tipo T 3.15A /250V.
4. La distancia entre la unidad interior y el suelo debe ser superior a 2 m.
5. El método de cableado debe ser conforme a la norma local sobre cableado.
6. Después de la instalación, se debe poder llegar con facilidad al enchufe de red.
7. La pila agotada debe eliminarse de forma adecuada.
8. El electrodoméstico no está diseñado para ser utilizado por menores o personas discapacitadas sin supervisión de un adulto.
9. Debe controlarse a los menores para que no jueguen con el aparato de aire acondicionado.
10. El aparato debe instalarse sobre un soporte suficientemente resistente.
11. El diagrama del cableado se adjunta en el interior de la máquina
Máximo: D.B / W.B Mínimo: D.B / W.B
Máximo: D.B Mínimo: D.B
Máximo: D.B Mínimo: D.B
Máximo: D.B / W.B Mínimo: D.B / W.B
32oC/23oC 18oC/14oC
43oC/26oC 18oC
27oC 15oC
24oC/18oC
-7oC/-8oC
18
Loading...
+ 45 hidden pages