Haier HCC3320AES, HCC6320AES Installation Guide

0 (0)
24”, 30” and 36” Electric Radiant Cooktops
Tables de cuisson électriques radiantes
de 24”, 30” et 36”
Supercies de cocción eléctricas radiantes
de 24”, 30” y 36”
Installation Instructions
Instructions d’installation
Instrucciones de instalación
HCC6320AES
OFF
OFF
HI
HI
MED
MED
LO
LO
HI
HI
LO
OFF
MED
DUAL
SINGLE
SINGLE
OFF
HI
MED
LO
HI
HI
LO
MED
OFF
MED
DUAL
HOT SURFACES
ENGLISH
Installation Manual
3
Table of Contents
Page
Special Warnings ..............................................................
Product Dimensions and Cutout Requirements.............
Important
Preparation Suggestions.....................................
Cooktop Installation..........................................................
Electrical Connections..................................................
..
General information...........................................................
3-Wire branch
circuit ......................................................... 1
4-Wire
branch circuit ......................................................... 1
Pay attention to these symbols present in this
manual
DANGER
You can be killed or seriously injured if you don't
IMMEDIATELY follow instructions.
WARNING
 This is the safety alert symbol. This symbol
alerts you to potential hazards that can kill or
hurt you and others.
 You can be killed or seriously injured if you
don't follow these instructions.
READ AND SAVE
THESE INSTRUCTIONS.
To installer:
Leave these instructions with the appliance.
To customer:
Retain these instructions for future reference.
WARNING
 If the information in this manual is not followed
exactly, a fire or explosion may result in
personal injury or death.
 Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of
this or any other appliance.
WARNING
Special Warnings
Please read all instructions before using this appliance
Proper installation is your responsibility. Have a
qualified technician install this cooktop.
Important:
 Observe all governing codes and ordinances.
 Write down the model and serial numbers before
installing the cook top. Both numbers are on the
serial rating plate located on bottom of cooktop
box.
Before Starting Installation
WARNING
It is the customer's responsibility to contact a
qualified electrical installer. To assure that the
electrical installation is Adequate and in
conformity with national electrical code:
ANSI/NFPA 70-latest edition** or CSA standards
C22.1-94, Canadian Electrical Code, part No.0-
M91 - latest edition*** and all local codes and
ordinances.
Copies of the standards listed may be obtained from:
** National Fire Protection Association One Batterymarch Park
Quincy, Massachusetts 02269
*** CSA International 8501 East Pleasant Valley Rd. Cleveland,
OH 44131-5575
To eliminate the risk of burns by reaching over
heated surface units, cabinet storage space located
above the surface units should be avoided. If he
cabinet storage is to be provided, the risk can be
reduced by installing a range hood that projects
horizontally a minimum of 5" (12.7 cm) beyond the
bottom of cabinet.
IMPORTANT: Save these instructions for the local electrical inspector use.
INSTALLER: Please leave this manual with owner for future reference.
OWNER: Please keep this manual for future reference.
ENGLISH
Installation Manual
4
Figure 3. Cutout dimensions and requirements

LENGTH OFF CUT
A
LENGTH OFF CUT
B
1-1/2” (3.8CM)
MIN CLEARANCE
SEE NOTE
R
FROM EDGE OF CUTOUT
AND FRONT EDGE OF
COUNTERTOP
2-1/2” (6.5 cm)
SLOT FOR
CABLE
ROUTING
3-1/2” (9 cm)
2-1/2” (6.5 cm)
1-1/4” (
3.2 cm) Canadian
CUTOUT DIMENSION
2-1/4” (5.7cm) US
D
G
C
E
F
CUTOUT REQUIREMENTS
WALL COVERING CABINETS,
AND COUNTERTOP MUST
WITHSTAND HEAT UP TO 93° C (200° F)
30”
(76.2 cm)
21”
(53.3
cm)
2” 3/16
(5.6 cm)
21”
(53.3 cm)
2” 3/16
( 5.6 cm)
36”
(91.4 cm)
24”
(61 cm)
21”
(53.3 cm)
3” 1/8
(7.9 cm)
Figure 1. Energy regulator
Figure 2

ENGLISH
Installation Manual
5
Important Preparation Suggestions
1. Chamfer all exposed edges of decorative laminate
to prevent damage from chipping.
2. Radius corners of cutout and file to Insure
smooth edges and prevent corner cracking.
Recommend 1/4“or 3/8“diameter drill In each
corner.
3. Rough edges, inside corners which have not been
rounded and forced fits can contribute to cracking
of the countertop laminate.
This cooktop has been designed with wide
tolerances of cut-out to cover possible
replacement with other brands. We recommend
to that you consider the minimum dimension of
cut-out size In the case of new
Installation.
Some cut out sizes for possible replacements:
CUTOUT
WIDTH
A B C D E F G
24” (60 cm)
22 5/8”
(57.4 cm)
22 13/16”
(58.0 cm)
19-1/4”
(49.0 cm)
19-9/16”
(49.7 cm)
24”
(60 cm) min
18” (45.7 cm)
min Height from
countertop to
nearest cabinet
on either side
of unit
30” (76.2 cm)
min.(see note*)
Clearance from
countertop to
unprotected
overhead
surface
2” (5 cm) min
Clearance from
cutout to side
wall on the left
and right of the
unit
13” (33 cm)
Depth of
unprotected
overhead
cabinets
30” (76.2cm)
28-11/16”
(72.9 cm)
28 15/16”
(73.5 cm)
19-1/4”
(49.0 cm)
19-9/16”
(49.7 cm)
30”
(76.2 cm) min
36” (91.4 cm)
34-1/16”
(86.5 cm)
34-5/16”
(87.2 cm)
19-1/4”
(49.0 cm)
19-9/16”
(49.7 cm)
36”
(91.4 cm) min
IMPORTANT
Under the cooktop it is necessary to install a
partition as shown in gure 2-3.
* NOTE
24” (61 cm) min. clearance if bottom of wood or metal cabinets is protected
by not less than 1/4“ (0.6 cm) 
ame retardant millboard covered with no less
than No. 28 MSG sheet steel 0.015” (0.04 cm) stainless steel, or 0.024”
(0.06 cm) aluminum or 0.020” (0.05cm) copper. 30”(76.2 cm) min.
clearance between top of cooking platform and bottom of unprotected
wood or metal cabinet
Dim . Inches cm
24” 22 13/16” x 19-9/16”
58.0 x 49.7
30” 28-15/16” x 19-9/16”
73.5 x 49.7
36” 34-5/16” x 19-9/16”
87.2 x 49.7
ENGLISH
Installation Manual
6
Cooktop Installation
WARNING
 Excessive Weight Hazard
Use two or more people to move and install
cooktop.
Failure to do so can result in back or other injury.
 Cut Hazard
Beware of sharp edges. Use the polystyrene ends
when carrying the product. Failure to use caution
could result in minor injury or cuts.
 Always consult t
he countertop manufacturer for
specific instructions.
 Ensure the countertop is square and level and
ensure no structural members interfere with space
requirements.
 Prepare the cut-out according to the instructions
(see cut-out dimensions).
 Make sure the wall coverings, countertop and
cabinets around the cooktop can withstand heat
(up to 200 °F / 93 °C).
Figure 4. Tools you will need
Step 1
Remove packaging materials and literature package
from the cooktop before beginning installation.
Remove Installation Manual from literature pack and
read them carefully before you begin.
Figure 5. Parts
COOKTOP
INTERNAL PACKAGING
CARDBOARD
TOP-CARDBOARD
MANUAL
TOP PACKAGING
GASKET
SCRAPER
BOTTOM PACKAGING
Figure 5b
MANUAL
GASKET
SCRAPER
CARDBOARD
TOP PACKAGING
COOKTOP
SIDE
PACKAGING
ENGLISH
Installation Manual
7
Step 3
A foam tape is provided to seal the cooktop edges to
the countertop.
Apply tape approximately 1/16" (1.5 mm) from the
glass edge to the underside of the cooktop glass. Use
tape around the entire glass perimeter. Cut off excess
where tape ends butt.
Step 2
Place a towel
or table cloth onto the counter top. Lay
the cooktop upside down onto the protected surface.
BURNER BOX
TABLE CLOTH
Figure 6
BURNER BOX
COOKTOP GLASS
FOAM TAPE
SEAL
Figure 7
Figure 9 (Mod. 30”/36”)
Figure 9b (Mod. 24”)
Figure 8
Step 4
Insert the cooktop centered into the cutout opening.
Make sure the front edge of the counter top is parallel
to the cooktop. Make inal check that all required
clearances are met.
Step 5
Four clamp brackets are provided to clamp the cooktop to
the countertop. Tighten screws just enough to hold brackets
in place when cooktop is put into cutout. Tighten screws
securely.
ENGLISH
Installation Manual
8
WARNING
THE CONDUIT IS 3 FEET LONG
The junction box, must be located where it will
allow considerable slack in the conduit for
serviceability.
Important:
 For solid surface material installations such as
Surel™
and Corian
®
, consult with solid
surface
manufacturer. Apply heat reflective tape such
as Scotch
®
Aluminum Foil Tape #425 or #427
around the cutout so that it folds over on the top
and sides.
 Do not wrap the tape underneath the cooktop.
Be sure the tape extends beyond the outermost
flange of the cooktop. All corners should be
covered with tape.
Figure 10
Figure 11
ENGLISH
Installation Manual
9
Electrical Connections
DANGER
Disconnect power before servicing the product.
Failure to do so could result in death or
electrical shock.
General information
WARNING
 The models may be powered at 240V or 208V.
This cooktop does not require a neutral connection. If
the cooktop is to be compl
etely enclosed in a cabinet,
feed the cooktop cable through the opening in the
cabinet. Make the electrical connection following the
appropriate steps for your installation.
Your cooktop must be connected to the proper
electrical voltage and frequency as specified in the
table on the right.
Connect with copper wire only
If the house has aluminum wiring, follow the
procedure below:
1. Connect the aluminum wiring to the copper wire
by using special connectors designed and
Underwriters Laboratories-listed for joining copper
to aluminum. Follow the electrical connector
manufacturer's recommended procedure.
2. Aluminum/copper connection must conform with
local codes and industry- accepted wiring
practices.
The flexible conduit (supplied) 3 feet long (100 cm)
located at the right rear of the cooktop bottom box
should be connected directly to junction box. Do not
cut the conduit. A U.L - or CSA - listed conduit
connector must be provided at each end of the power
supply cable (at the cooktop and at the junction box.)
A time delay fuse or circuit breaker is recommended.
Do not ground to a gas pipe. Do not have a fuse in the
grounding or neutral circuit.
Fuse both supply (phase) lines.
WARNING
Improper connection of aluminum house wiring to
the copper leads can result in a serious problem.
National Fire Protection Association
Batter/march Park Quinc
y, Massachusetts 02269
A three-wire, single phase, 240 Volt 60 cycle electrical
system (properly circuit protected to meet Local
Codes of NFPA No.70) must be provided. Unit must
be properly grounded in accordance with local wiring
code. The chart below recommends the minimum
circuit protector and wire size if the appliance is the
only unit on the circuit. If smaller sizes of wire are
used, the unit efficiency will be reduced and a fire
hazard may be created. It is advisable that the
electrical wiring and hookup be accomplished by a
competent electrician.
SERIAL TAG
Model
Power Supply
240 V 60 Hz 208 V 60 Hz
Approval
code
36" 9,4kW 39A 7,06kW 34A
514V50NC
Figure 12. Location of serial tag
Model
Power Supply
240 V 60 Hz 208 V 60 Hz
Approval
code
24”
HCC2320AES
6,1kW 25,5A 4,6Kw 22A
514Y40IL
30”
HCC3320AES
6,7kW 28A 5,03kW 24A
514T40IA
514T40NA
36” 9,4kW 39A 7,06kW 34A
514V50IC
514V50NC
HCC6320AES
Loading...