Haier 10571570, AB212BCBAA User Manual

Haier Network Air Conditioner
AB212BCBAA
CONTENTS
Before Use Operation Points
Name of Parts Safety Precautions
*********** 1-2
************* 3-4
********** 5-6
Operation Instruction Fan Operation
************** 7
Auto, Cooling, Dehumidifying, Heating operation
Swing Operation Sleep Function Timer On/Off Function Timer On-Off Function
Usersí Attention
************ 8
************ 9
************* 10
******** 11
******** 12
************ 13
Maintenance Maintenance
Troubleshooting
*************14-18
*********** 19-20
Installation of Indoor Unit Installation Instruction
****** 21
22
*
Installation Procedure
*
No.
0010571570
Please read this manual carefully before using Please keep this manual for future use
****** 23*36
Characteristics of Products
Characteristics of Products
1.Free combination multi-split.
2.Four-direction air sending, more even temperature adjustment.
3.Inner hidden type installation, space-saving; harmonized with the ceiling, exquisite and beautiful.
4.Powerful circular air volume, quick temperature adjustment.
5.This air conditioner has POWER FAILURE RESUME FUNCTION.
6.Anti-bacteria mildew resistant air filter, fresher air creates more healthy. This unit has the function of far distance monitoring. Through the telephone network, it can be effectively controlled in any other far-distance place. (Only after equipped with the ìfar distance detectorî made by our company can this function be fulfilled.)
7.This unit has the function of far distance monitoring. Through the telephone network,
it can be effectively controlled in any other far-distance place. (Only after equipped with the ìfar distance detectorî made by our company can this function be fulfilled.)
Far distance monitoring
There is a pre-set far distance control communication interface on the control panel of indoor unit. After installing the peripheral equipment according to the manual attached with the Haier made far distance control detector, the computer management or other place monitoring can be achieved to the air conditioner.
Operation points
Operation of air conditioner
When the ambient humidity is too high, in COOLING or DEHUMIDIFYING mode, there may be water dropped in the air outlet.
3-minute protection function
If start the unit immediately only after it is turned off, the compressor will start after 3 minutes have elapsed to protect the compressor.
Change of fan speed
In COOLING mode, the air sending is set at AUTO, when the indoor temperature is near the set temperature, the fan speed will lower automatically. In HEATING mode, when room temperature reaches the set temperature, the compressor will stop running, and the fan will change to LOW FAN or stop.
In DEHUMIDIFYING mode, the fan speed will change automatically.
Far distance monitoring
There is a pre-set far distance control communication interface on the
control panel of indoor unit. After installing the peripheral equipment according to the manual attached with the Haier made far distance control detector, the computer management or other place monitoring can be achieved to the air conditioner.
1
Operation points
Anti-cold air blowing out
During Heating operation, after starting the unit, the indoor fan motor will not rotate immediately to prevent cold air from blowing out.
Defrosting function
During Heating operation, when frost formed on the heat exchanger of outdoor unit, the air conditioner will defrost automatically for several minutes. During defrosting, both the fan of indoor and outdoor unit do not run. After finishing defrosting, the air conditioner will automatically resume operation.
Hint
When the air conditioner is in Heating mode, it absorbs heat from outside and release to indoors. So the outdoor temperature may affect the Heating effect.
Please wait
?
Power failure resume function (please set and use this function according to actual condition)
After setting power failure resume function, if there is a sudden power failure during unit operation, when power on for again, the unit will resume the previous state. Setting method: when the wire controller is in ON state (except for TIMER and FAN mode), press the SLEEP button for 10 times in 5 seconds, after the buzzer sounds 4 times, the unit will change to POWER FAILURE RESUME function. Cancellation method: press the SLEEP button 10 times in 5 seconds, after the buzzer 2 times, the POWER FAILURE RESUME function is cancelled. Note: After the unit is set POWER FAILURE RESUME function, if there is a sudden power failure in using, during this period of time if there is no need to use the unit for a long time, please cut off power to prevent the air conditioner from automatically resuming to the previous setting if power failure resumes, or press the ON/OFF button to turn off the unit after power failure resumes.
2
Name of Parts
Indoor Unit
Drain hose Louver
Louver
(inside of air outlet)
Air outlet
Air filter
(inside of air inlet grille)
Wire Controller
Connection pipes and electric wire
Air inlet grille
** ** **
AUTO
** **
**
**
**
**
****
**
**
**
**/**
3
Name of Parts
Wire Controller
13 12
11 10
9 8
7 6
5 4
3 2 1
AUTO
** **
1.ON/OFF button
Used to turn on/off unit
2.Temperature display
3.Clock display
4.Timer ON/OFF display
5.Humidity display
6.Air filter cleaning display
When there is too much dust collected on the air inlet, the wire controller will show this display to remind the user to clean the air inlet. After cleaning and installation, just press the air filter reset button.
*
17.Operation mode button
7.Super/Soft operation display
8.Fan speed display
Auto
Low Fan Med Fan High Fan Auto
9.Auto Swing display
10.Health state display
11.Fresh air state display
12.Humidifying state display
Note:
1.This model does not have the following related display and function
2.Non-electric heating type, there is no electric heating button and electric heating
display
16
14 15 16 17 18
** ** **
**
**
**
**/**
19
**
**
**
****
**
13.Sleep state display
14.Network control display
15.Working mode display
Working
Auto
Cooling
mode Wire
controller
operation
operation
Dehumidifying operation
16.Electric heating display Used to set working mode:
Auto, Cooling, Dehumidifying, Heating, Fan
18.Fan speed button Used to set fan speed: Low Fan, Med Fan, High Fan, Auto
19.Swing button
Used to set Auto Swing or Fixed air sending direction
20.Temperature Setting button Used to set temperature,
temperature range: 16*~30*
21.Clock button Used to calibrate the time of timer and clock
20 21
22 23
24 25 26 27 28 29
Heating operation
22.Setting button
Used to confirm
the time of timer and clock
23.Sleep button Used to set Sleep
state or Power Failure Resume Function
24.Time Adjusting
button
Used to adjust the time of timer and clock
25.Reset button
Fan operation
When the wire controller appears abnormal condition, use a sharp-pointed article to press this button to make the wire controller resume normal
26.Air Filter Reset button
After cleaning the air inlet, press this button, the unit can start to operate
27.Timer button
Used to set the mode of timer
28.Lock state display
29.Electric heating button
* * 10 11 12 28
29
Calibration of clock
When turning on the unit for the first time, the clock should be calibrated. The method of calibration is:
1.Press “Clock” button, the Clock display “AM” “PM” will flash.
2.Press * or * to adjust time. For each press, the time will increase or*decrease 1
*minute. If depressing the button, the time will increase or decrease*rapidly.
3.After confirming the time, press “Set” button, “AM” or “PM” will stop flashing,
*the clock will begin to work.
4
Safety Precautions
Please read the following Safety Precautions carefully and use the air conditioner properly.
The following lists four kinds of safety precaution items and suggestions:
!
Warning: Improper use may cause death or serious injury.
!
Notice: Improper use may cause body hurt or unit damage; in some circumstance, it may cause serious results.
*
Those contents marked with “Prohibition” are definitely prohibited action, otherwise, it may cause unit damage or risk to users’ safety.
* Those contents marked with “Forced” are definitely forced action,
otherwise, it may cause unit damage or risk to users’ safety.
The following safety precautions must be observed. This safety precautions should keep in hand for reference. If the air conditioner is given to a new user, this manual should be attached with unit to the new user.
Warning
!
If finding abnormal phenomenon (e.g. smell of firing), please cut off the power first, and contact the after-sales service worker for treatment. Under this circumstance,
Cut off power
if continue using the air conditioner,it may be damaged, it may also cause electric shock or fire accident.
When repair is needed, please ask the after-sales service worker for help. Improper repair and maintenance may cause water leakage, electric shock and fire. During unit operation, do not insert fingers or other objects into air inlet, air outlet and louver.
Because high rotation speed fan is dangerous, it may cause injury.
Ask after-sales service worker to take measure to prevent refrigerant from leaking.
If the leaked refrigerant exceeds a certain density, it will cause lack of oxygen. If the room installed with air conditioner is too small, do take enough measure in order to avoid lack of oxygen even if refrigerant leaks.
When have to dismantle and reinstall the air conditioner, please ask the after-sales service worker to perform the work. Improper installation may cause water leakage, electric shock or fire.
5
Safety Precautions
Notice
Do not use wet hands to operate the air conditioner. Otherwise, it may cause electric shock.
Only use the proper specified fuse. Do not use cable or other materials to replace the fuse, otherwise it may cause fire and other trouble.
Do not put the fire devices in the places, which the air from the air conditioner can directly blow. It may cause the fire devices cannot burn completely.
Do not put or use any spray near the air conditioner, otherwise it may cause fire.
Do not use water to clean air conditioner, otherwise may cause electric shock.
Connected with the grounding wire.
The grounding wire shouldn’t be connected with gas pipe, tap water pipe, lightning rod or telephone line. Improper grounding may cause electric shock accident.
The drain hose should be arranged properly to have a smooth drainage. If the drain hose is not arranged properly, the leaked drain water may damage the furniture or other articles alike.
Do not install the air conditioner in a place where the inflammable gas maybe exists. The inflammable gas around the air conditioner may cause fire accident.
The Creepage breaker should be equipped. If not equipped with Creepage breaker, it may cause Creepage.
Only after cutting off the power, can the cleaning of the air conditioner be performed to avoid leading to electric shock or injury.
6
Not in
operation
When using indoor smoky type pesticide, do not use air conditioner. Otherwise, it may cause the chemicals accumulate in the unit, result in doing harm to the people’s health who is extremely sensitive to these chemicals.
Operation instruction
** ** **
**
2
**
3
**
**
**/**
****
**
**
**
4
1
Fan operation
1
Turn on the unit
Press the ON/OFF button to turn on the unit The LCD display of the wire controller
will show the previous working state (except for Timer, Sleep, Swing mode), the operation indicator light on the wire controller will light up.
2
Choose of working mode
Press MODE button, each press the working mode will change as the following sequence:
.
AUTO
COOLING
DEHU
HEATING
choose FAN operation
Adjusting FAN SPEED
3
Press the FAN SPEED button to change fan speed:
LOW FAN MED FAN HIGH FAN
Choose the desired fan speed
4
Turn off the unit
Press the ON/OFF button to turn off the unit.
The wire controller only shows the clock and room temperature.
About FAN operation:
FAN operation refers the air conditioner does not perform COOLING and HEATING operation, but FAN operation. In this mode, the air conditioner cannot perform AUOT FAN operation, and does show the temperature value on the wire controller.
FAN
7
Operation instruction
2
** ** **
4
**
3
**
**
**
**
3
****
**
**
**
Auto/Cooling/Dehumidifying/Heating operation
1
Turn on the unit
Press the ON/OFF button to turn on the unit The LCD display of the wire controller will show the previous working state (except for TIMER, SWING, SLEEP mode). The operation indicator light on the wire controller will light up.
**/**
5
1
2
Choose of working mode
Press MODE button, each press the working mode will change as the following sequence:
When room temperature is higher than set temperature, unit in COOLING operation.
Set temperature + 2* Set temperature
Ultra-low air flow
When room temperature reaches set temperature + 2*, the unit will operate in mild dehumidifying operation.
3
AUTO COOLING DEHUMIDIFYING HEATING FAN
then choose AUTO, COOLING, DEHUMIDIFYING, HEATING operation.
Set temperature
Press the TEMP. SET button
*Each press , the set temperature will increase 1 degree. *Each press, the set temperature will decrease 1 degree.
Set the desired temperature.
Adjusting FAN SPEED
4
Press the FAN SPEED button, for each press, the fan speed will change as the
In Heating operation, after start
following sequence:
the unit, the air conditioner will sending warm air a moment later to prevent the cold air blowing out. In Dehumidifying, when the room temperature drops 2* higher than the set temperature, regardless the set fan speed, the air conditioner will intermittently operate in low fan speed.
5
LOW FAN MED FAN HIGH FAN AUTO
Choose the desired fan speed.
Turn off the unit
Press the ON/OFF button to turn off the unit.
The wire controller only shows the clock and room temperature.
Hints:
The wire controller can memorize the working condition of each time. When start the unit for the second time, just need to press ON/OFF button, the air conditioner will work according to the previous working mode. (except for Timer, Sleep and Swing)
AUTO
8
Operation instruction
Press SWING button, the LCD of the wire controller display “ ”, the louver of the air conditioner begins
** ** **
**
**
**
**
**
**
**
****
**
**/**
automatic swing and air sending.
When the Auto SWING of the air conditioner swings to an appropriate angle, press SWING button, the display “ ” on the LCD of the wire controller will disappear, the air sending direction is fixed. When fixing the air sending direction, the louver should be kept in the following position: In COOLING and DEHUMIDIFYING, it is better to be upward. In HEATING, it is better to be downward.
Swing
Auto swing
Fixed air sending direction
Always use the SWING button of the wire controller to adjust the louver. If adjust the louver manually, it may damage the louver.
During COOLING and DEHUMIDIFYING, do not make the louver downwards for a long time. Because the vapor around the air outlet grille may be condensed and may have drop of water.
When the infant, children, ages and the patients use the air conditioner, please pay attention to the set temperature.
9
Operation instruction
Sleep operation
Before going to bed, you can press the SLEEP button, the air conditioner will operate in comfort sleep mode to make you have a sound sleep.
Before using this function, you should calibrate the clock first, otherwise, the SLEEP function will be out of order.
Use of SLEEP function
After turning on the unit, setting the working mode, then press SLEEP button to make the air conditioner have the previous Sleep time (powered on for the first time or after performing Sleep is 1h). The Sleep symbol will appear. Press time */* button, you can choose between 1~8h. Each press, it may increase/decrease 1h and will display in the humidity area with “xh”, and display “Timer Off” in Timer Off area and the time to turn off; press Sleep button again to cancel Sleep function. The Sleep symbol disappears.
Operation modes
1.In COOLING, DEHUMIDIFYING operation
1 hour later in SLEEP operation, the temperature will increase 1* from the set temperature, another 1 hour later increase another 1*, then the unit will operate continuous for 6 hours, then it turns off automatically. The temperature is higher than set
SLEEP operation starts
increase 1*
1 hour
increase 1*
1 hour
Set temperature
in COOLING* DEHUMIDIFYING operation
SLEEP operation stops
about 6 hours
turn off
temperature to prevent you from getting a cold.
2.In HEATING operation
1 hour later in SLEEP operation, the temperature will decrease 2* from the set temperature, another 1 hour later increase another 2*, then the unit will operate continuous at this temperature for 3 hours, then it increases 1*, after operating at this
Set temperature
1 hour
decrease 2*
1 hour
SLEEP operation starts
in HEATING operation
decrease 2*
3 hours
about 3 hours
increase 1*
SLEEP operation stops
temperature for another 3 hours, the unit will turn off automatically. The temperature is lower than set temperature to prevent you from feeling uncomfortable during sleep.
3.In AUTO operation
The air conditioner will perform the relative SLEEP operation according to automatically chosen operation
**
** ** **
**
**
**
**
****
**
**
**
mode.
4.In FAN operation
Cannot use SLEEP function
**/**
Note:
lAfter setting Sleep function, it is not permitted to adjust clock. lThe Sleep time is less than 8h, after reaching the set time, the unit will automatically stop. lSet Sleep function after setting “Timer Off” function, the air conditioner will perform
Sleep function.
lAfter setting Sleep function, the Timer function cannot be set. lSet Sleep function after setting “Timer On” function, the Sleep function can only be set
in the set time of Timer On.
turn off
10
Loading...