Haier 10552537 User Manual

HSU-07HV03/R2(DB) HSU-09HV03/R2(DB) HSU-09HV03/R2(SDB) HSU-12HV03/R2(DB) HSU-12HV03/R2(SDB)
HSU-18HV03/R2(DB)
No, 0010552537
SPLIT TYPE ROOM AIR CO NDITIONER
OPERATION MANUAL
Please read this operation manual before using the air conditioner
Cautions
Disposal of the old air conditioner
It must be noticed that air conditioner system contains refrigerants, which require speciali­zed waste disposal. The valuable materials contained in an air conditioner can be recycled .Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damagedprior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.
Disposal of the packaging of your new air conditioner
All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.
The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads
conta in no fluorochloric hydrocarbon.
All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.
Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal ser vices nearest to your house.
Safety Instructions and Warnings
Before star ting the air conditioner, read the information given in the User's Guide caref­ully. The User's Guide contains very impor­tant observations relating to the assembly, operation and maintenance of the air conditioner.
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.
Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
Installation shall be done by professional people, don't install unit by yourself.
For the purpose of the safety,the air con­ditioner must be properly grounded in acco­rdance with specifications.
Always remember to unplug the air conditioner before openning inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.
All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditioner.
Do not damage any par ts of the air conditioner that carry refrigerant by piercing or performating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.
2
Cautions
Do not obstruct or cover the ventilation grille of the air conditoner.Do not put fingers or an y other things into the inlet/outlet and swing louver.
Do not allo w children to play with the air conditioner.In no case should children be allowed to sit on the outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
The machine is adaptive in following situation
Indoor
Cooling
Outdoor
Indoor
Heating
Outdoor
Maximum:D.B/W.B 32oC/23oC
Minimum:D.B/W.B
Maximum:D.B/W.B Minimum:D.B
Maximum:D.B Minimum:D.B
Maximum:D.B/W.B
Minimum:D.B/W.B
18oC/14oC 43oC/26oC
18oC 27oC
15oC 24oC/18oC
-15oC
7. The appliance is not intended for use by young children or infirm persons without supervision.
8. Young children should be supervised to ensure that they do not play with the applience.
9.Please employ the proper power plug, which fit into the power supply cord.
10 .The power plug and connecting cable must have acquired the local attestation.
2. If the power supply cord is damaged, it must be replaced by the manuf acturer or its service agent or a similar qualified person.
3. If the fuse of indoor unit on PC board is broken,please change it with the type of T. 3.15A/ 250V.
4. The wiring method should be in line with the local wiring standard.
5. After installation, the power plug should be easily reached.
6. The waste battery should be disposed properly.
3
Cautions
Safety Instruction
Please read the f ollowing Safety Instructions carefully prior to use.
The instructions are classified into two levels, W ARNING and CAUTION according to the seriousness of possible risks and damages as f ollows. Compliance to the instructions are strictly required for saf ety use.
Installation
WARNING
Please call Sales/Service Shop f or the Installation.
Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire , water leakage.
lnstallation in a inadequate place may cause accidents. Do not install in the following place.
CAUTION
Connect the earth cable.
earth ing
Do not install in the place where there is any possibility of inflammable gas leakage around the unit.
PROHIBITION PROHIBITION
Do not get the unit exposed to vapor or oil steam.
4
Check proper installation of the drainage securely
STRICT ENFORCEM ENT
Cautions
When abnormality such as burnt-small fo und, immediately stop the operatio n button and contact sales shop .
WARNING
Use an exclusive power source with a circuit breaker
OFF
Co nnect power supply cord to the outlet completely
STRICT
ENFORCEMENT
Do not use power supply cord in a bundle.
PROHIBITION
Do no t start or stop the operation by disconn ecting the power supply cord and so on.
PROHIBITION
Do not use for the purpose o f storage of food, art work, precise equipment, breeding, or cultivation.
STRICT
ENFORCEMENT
Use the proper voltage
STRICT
ENFORCEM ENT
Take care not to damage the power supply cord.
PROHIBITION
Do n ot channel the air flow directly at people, especially at infants or the aged .
PROHIBITION
CAUTION
Take fresh air occasionally especially when ga s appliance is running at the same tim e.
Do not use po wer supply cord
extende d or connected in halfway
PROHIBITION
Do not insert objects into the air inlet or outlet.
PROHIBITION
Do not try to repair or reconstruct by yourself.
Do not ope rate the switch with wet hand.
PROHIBITION
Do not install the unit near a fireplace or other heating apparatus.
PROHIBITION
Do not place animals or plan ts in the direct path of the air flow
PROHIBITION
STRICT
ENFORCEMENT
Ch eck good condition of the installation sta nd
PROHIBITION
Do not place any objects on or climb on the unit.
PROHIBITION
5
PROHIBITION
Do not pour water onto the unit for cle aning
PROHIBITION
Do n ot place flower vase or water containers on the top of the unit.
PROHIBITION
Parts and Functions
Indoor unit
Display board
Inlet
Air Purifying Filter
(inside)
Inlet grille
Vertical flap (adjust up and down air flow. Don't adjust it m anually)
Horizontal louver
(adjust left and right air flow)
Outdoor unit
Outlet Air filter(inside)
UV light degerming device (inside) (Only for the units of SDB)
Anion generator
(inside)
Power plug
HSU-07HV03/R2(DB) HSU-09HV03/R2(DB) HSU-12HV03/R2(DB)
1
OUTLET
2
INLET CONNECTING PIPING AND ELECTRICAL WIRING
3
CHANGE-FOR-FRESH-AIR BOX
4
HSU-09HV03/R2(SDB) HSU-12HV03/R2(SDB) HSU-18HV03/R2(DB)
CHANGE-FOR-FRESH-AIR TUBE
5
CHANGE FOR FRESH AIR SIGNAL WIRE
6 7
DRAIN HOSE
6
Parts and Functions
19
18 2434 16 17
9. HEALTH button
Used to set healthy operation.
10. ON/OFF button
Used for unit start and stop .
11. TIMER ON display
12. FAN SPEED display
FRESH
STERILIZE
HSU-09HV03/R2 (SDB) HSU-12HV03/R2 (SDB)
28
33
1.CODE
Use d to select CODE A or B with a press,A or B will be displayed on LCD. Please select A without special e xplanation.
2.RESET
When the remote controller appears a bnormal, use a sharp pointed article to press this button to reset the remote controller no rmal.
3.LIGHT button
Control the lightening and extinguishing of the indoor LED display b oard.
4. TIMER button
Used to select TIMER ON, TIMER OFF, TIMER ON-OFF.
5. CLOCK button
Used to set correct time.
6. SLEEP button
Used to select sleep mode.
7. MODE button
AUTO COOL DRY FAN HEA T
8. HOUR button
Used to set clock and timer setting.
LOW HI
MED AUTO
13. LOCK display
14. SWING UP/DOWN display
15. SLEEP display
16. HEALTH display
17.FRESH AIR display
18. Operation mode display
Operation mode A UTO HEAT FANCOOL DRY
Remote controller
Display board
19.Singal sending display
20. UV light degerming function display
21. Left/right air flow display
22. TEMP display
Remote controller: to display the TEMP . setting.
23. TIMER OFF display
24. TIMER/SLEEP display
25. TEMP button
Used to select you r desired temperature.
26. FAN button
Used to select fan speed: LOW,M ED, HI, AUTO.
27. HEALTH AIRFLOW button
Used to set the h ealth airflow mode.
28. SWING UP/DOWN button
Used to select u p or down air sending direction.
29. SWING LEFT/RIGHT button
Use d to select left/right air flow.
30. FRESH button
Use to set fresh air fun ction.
31. SET button
Used to confirm timer and clock settings.
32. STERILIZE button
Use to set UV ligh t degerming function.
33. LOCK
Use d to lock buttons and LCD display. If pressed, the other bu ttons will be disabled and the lock condition display appears. Press it once again , lock will be canceled and lock conditio n display disappears.
34. Ambient temp.display
When receiving the remote contro l signal, display the set temperature and in the rest time the room te mperature is displayed and this room temperature is only for reference.
NOTE:(1) The following functions and related displays are not available:
(2) Cooling only unit do not have functions and displays related with heating.
7
1
Parts and Functions
19
18 2433 16 17
9. HEALTH button
Used to set healthy operation.
10. ON/OFF button
Used for unit start and stop .
11. TIMER ON display
12. FAN SPEED display
LOW HIMED AUTO
28
30 31
32
HSU-07HV03/R2(DB) HSU-09HV03/R2(DB) HSU-12HV03/R2(DB)
HSU-18HV03/R2(DB)
1.CODE
Use d to select CODE A or B with a press,A or B will be displayed on LCD. Please select A without special e xplanation.
2.RESET
When the remote controller appears a bnormal, use a sharp pointed article to press this button to reset the remote controller no rmal.
3.LIGHT button
Control the lightening and extinguishing of the indoor LED display b oard.
4. TIMER button
Used to select TIMER ON, TIMER OFF, TIMER ON-OFF.
5. CLOCK button
Used to set correct time.
6. SLEEP button
Used to select sleep mode.
7. MODE button
AUTO COOL DRY FAN HEA T
8. HOUR button
Used to set clock and timer setting.
NOTE:(1) The following functions and related displays are not available:
(2) Cooling only unit do not have functions and displays related with heating.
13. LOCK display
14. SWING UP/DOWN display
15. SLEEP display
16. HEALTH display
17.FRESH AIR display
18. Operation mode display
Operation mode A UTO HEAT FANCOOL DRY
Remote controller
Display board
19.Singal sending display
20. POWER/SOFT display
21. Left/right air flow display
22. TEMP display
Remote controller: to display the TEMP . setting.
23. TIMER OFF display
24. TIMER/SLEEP display
25. TEMP button
Used to select you r desired temperature.
26. FAN button
Used to select fan speed: LOW,M ED, HI, AUTO.
27. HEALTH AIRFLOW button
Used to set the h ealth airflow mode.
28. SWING UP/DOWN button
Used to select u p or down air sending direction.
29. SWING LEFT/RIGHT button
Use d to select left/right air flow.
30. SET button
Used to confirm timer and clock settings.
31. POWER/SOFT button
Every time the butto n is pressed,display changes as follows:
32. LOCK
Use d to lock buttons and LCD display. If pressed, the other bu ttons will be disabled and the lock condition display appears. Press it once again , lock will be canceled and lock conditio n display disappears.
POWER SOFT
33. Ambient temp.display
Wh en receiving the remote control signal, display the set temperature and in the rest time the room tempe rature is displayed a nd this room temperature is only for reference.
1 17
8
BLANK
Parts and Functions
Clock Set
When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows:
1. Press CLOCK button,"AM " or "PM" flashes.
2. Press or to set correct time. Each press will increase or decrease 1 m in. If the button is kept depressed, time will change quickly.
3. After time setting is confirmed, press SET, "AM" or "PM" stop flashing, while clock starts working.
Remote controller's operation
When in use, put the signal transmission head directly to the receiver hole on the indoor unit.
The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well.
Don't throw or knock the remoter controller.
When electronic-started type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving the signals, so the distance to the indoor unit should be shorter.
FRESH
STERILIZE
Loading of the battery
Load the batteries as illustrated right 2 R-03 (7#) batteries
Remove the battery cover:
Slightly press" "area and push down the cover as illustrated.
Load the battery:
Be sure that the loading is in line with the "+" / ". request as illustrated on the bottom of the case.
Put on the cover again.
Confirmation indicator:
After pressing power ON/OFF, if no display, reload the batteries.
Note:
Full display or unclear display during operation indicates the batteries have been used up. Please change batteries.
Used two new same-typed batteries when loading.
If the remote controller can't run normally during operation, please remove the batteries and reload several minutes later.
Hint:
Rem ove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out, just need to press reset key.
9
Operation
HEALTH operation
Remote controller
FRESH
STERILIZE
1.Unit start
Press ON/OFF on the remote controller, unit starts. Health function includes health anion function, UV light
degerming function and change-for-fresh-air function.
2.Health anion function
Press HEALTH button. For each press, is displayed. Air conditioner starts health anion function operation.
For twice press, disappears,the operation stops.
3.UV light degerming function
Press STERILIZE button ," "and " "displayed on the remote controller and the air conditioning starts the UV light degerming function. " ": For timing operation of UV light degerming function and automatically canceled after 30 minutes' operation. " ": For the long-time running of UV light degerming function. No display: For UV light degerming function not starting.
4.Change-for-fresh-air function
Press FRESH button , " "displayed on the remote controller and the change-for-fresh-air function operation begins. For twice press , the display " "disappears and the change-for-fresh-air function operation is canceled
When indoor fan motor is running, it has healthy process function. (It's available under any mode)
When the fan in the indoor unit does not work, the health lamp lights up, but the anion generator does not release anion.
Note: (1)when the un it is operating health or sterilize function," "
displayed on the display board and " " is displayed on the di splay board in the fresh function.
(2) The b uttons and the functions of FRESH a nd STERILIZE are only for the units of HSU-0 9HV03/R2(SBD) and HSU-12HV03/R2(SBD).
(3) The b uttons and the functions of Power/Soft are only for the u nits of HSU-07 $09$12$18HV03/R2(BD).
(4) When using th e HEALTH/STERILIZE function, the backlight is gree n; When using th e FRESH function, the backlight is yellowish gree n; If using th e HEALTH/STERILIZE and FRESH functions at the same time, the color is the last one.
BRIEF INTRODUCTION TO HEALTH ANION FUCTION
The anion generator in the air conditioner can generate a lot of anion effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room.
About UV light degerming function
UV light emitted by the UV light device of the indoor unit catalytically activates the nano TiO2 on the multi-lights touching intermediary, and the degerming effect is highly efficient and lasting. Note: when the function is running, don't open the inlet grille.
About change-for-fresh-air function
1.After the change-for-fresh-air function is initiated, the outside air can enter the indoors through the change-for-fresh-air tube thereby keeping the indoor air fresh.
2.Setting the change-for-fresh-air function under the shutdown status: Under shutdown status, press the new wind key and the remote controller displays the on status of air flow, low wind, and change­ for-fresh-air functions, and now can set the timing open, timing close and time control switch. Press on-off button to cancel the change-for-fresh-air function.
10
Operation
Auto Operation
1. Unit start
Remote controller
2.Select operation mode
3.Select temp.setting
FRESH
STERILIZE
Press ON/OFF on the remote controller, unit starts.
Press MODE button. For each press, operation mode changes as follows:
Rem ote controller:
AUTO COOL DRY FAN HEAT
Then Select Auto operation
On the displaying board,colorful displaying bar will be white.
Press TEMP. button
Every time the button is pressed, temp.setting increase 1 C,if kept depressed, it will increase rapidly
Every time the button is pressed, temp.setting increase 1 C,if kept depressed, it will decrease rapidly
Select a desired temperature.
NOTE:If the setting temperature under the auto mode of the rem ote controller is adjustable, the setting temperature of the whole unit is adjustable; otherwise the setting temperature of the whole unit is not adjustable
4.Fan speed selection
Press FAN button. For each press, fan speed changes as follows:
Remote controller:
LOW
MED HI AUTO
Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
5.Unit stop
Press ON/OFF button, the unit stops. About Auto Operation
Under the mode of auto operation, air conditioner will automatically select Cool or Heat operation according to room temperature.
1 1
Operation
Cool Operation
1. Unit start
Remote controller
Press ON/OFF on the remote controller, unit starts.
2.Select operation mode
Press MODE button. For each press, operation mode changes as follows: Remote controller:
FRESH
STERILIZE
AUTO
Then Select COOL operation
On the displaying board,colorful displaying bar will be blue.
COOL DRY FAN HEAT
3.Select temp.setting
Press TEMP. button
Every tim e the button is pressed, temp.setting increase 1oC,if kept depressed, it will increase rapidly
Every tim e the button is pressed, temp.setting increase 1oC,if kept depressed, it will decrease rapidly
Select a desired temperature.
4.Fan speed selection
Press FAN button. For each press, fan speed changes as follows:
Remote controller:
LOW
MED
Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room tem perature.
HI AUTO
5.Unit stop
Press ON/OFF button, the unit stops.
12
Operation
Dry Operation
Remote controller
FRESH
STERILIZE
1. Unit start
Press ON/OFF on the remote controller, unit starts.
2.Select operation mode
Press MODE button. For each press, operation mode changes as follows:
Rem ote controller:
AUTO
Then Select DRY operation
On the displaying board,colorful displaying bar will be light blue
COOL DRY FAN HEAT
3.Select temp.setting
Press TEMP. button
Every time the button is pressed, temp.setting increase 1oC,if kept depressed, it will increase rapidly
Every time the button is pressed, temp.setting increase 1oC,if kept depressed, it will decrease rapidly
Select a desired temperature.
4.F an speed selection
Press FAN button. For each press, fan speed changes as follows:
Remote controller:
LOW
MED
Air conditioner is running under displayed fan speed. In DRY mode, when room temperature becomes 2OC higher than temp.setting,unit will run intermittently at LOW speed regardless of FAN setting.
HI AUTO
5.Unit stop
Press ON/OFF button, the unit stops.
13
Operation
Fan Operation
1. Unit start
Remote controller
2.Select operation mode
Press ON/OFF on the remote controller, unit starts.
Press M ODE button. For each press, operation mode changes as follows:
Remote controller:
FRESH
STERILIZE
AUTO
Then Select FAN operation
On the displaying board,colorful displaying bar will be pink.
COOL DRY FAN HEAT
3.F an speed selection
Press FAN button. For each press, fan speed changes as follows:
Remote controller:
LOW
MED HI
4.Unit stop
Press ON/OFF button, the unit stops.
About FAN operation
In FAN operation m ode, the unit will not operate in COOL or HEAT mode but only in FAN mode ,AUTO is not available in FAN mode.And temp.setting is disabled. In FAN mode,SLEEP and POWER/SOFT operation is not available.
1 4
Operation
Heat Operation
Remote controller
FRESH
STERILIZE
1. Unit start
Press ON/OFF on the remote controller, unit starts.
2.Select operation mode
Press MODE button. For each press, operation m ode changes as follows:
Remote controller:
AUTO
Then Select HEAT operation
On the displaying board,colorful displaying bar will be red
COOL DRY FAN HEAT
3.Select temp.setting
Press TEMP. button
Every time the button is pressed, tem p.setting increase 1oC,if kept depressed, it will increase rapidly
Every time the button is pressed, tem p.setting increase 1oC,if kept depressed, it will decrease rapidly
Select a desired temperature.
4.F an speed selection
Press FAN button. For each press, fan speed changes as follows:
Remote controller:
LOW
MED HI
Air conditioner is running under displayed fan speed IN HEAT mode, warm air will blow out after a short period of the time due to cold-draft prevention function.
When FAN is set to AUTO , the air conditioner autom atically adjusts the fan speed according to room temperature.
AUTO
5.Unit stop
Press ON/OFF button, the unit stops.
15
Operation
Air Flow Direction Adjustment
1.Status display of air sending
Vertical flap
Pos.1
Pos.2
Pos.3
FRESH
STERILIZE
Pos.4
Pos.5
Pos.6
(Auto swing)
Horizontal louvers
Pos.1
Pos.2
Pos.3
Pos.4
Pos.5
Pos.6
Pos.7
Pos.8
2.Up and down air flow direction
For each press of b utton, air flow direction on remote controller displays as f ollows according to different operation modes:
COOL/DRY/FAN
remote controller:
:
HEAT:
remote controller:
Pos.1 Pos.2 Pos.3 Pos.4 Pos.6
Pos.5 Pos.4 Pos.3 Pos.2 Pos.1 Pos.6
AUTO:
remote controller:
Pos.1 Pos.2 Pos.3 Pos.4 Pos.5 Pos.6
The vertical flap will swing according to the abo ve positions
3.Left and right air flow direction
For each press of button, remote controller displays as follows :
remote controller:
Pos.1 P os.2 Pos.3 Pos.4 Pos.5 Pos.6 Pos.7 Pos.8
The horizontal louvers will swing according to the above positions.
Note:When restart after remote turning off, the remote controller will automatically memorize the previous set swing position.
1 6
Operation
Sleep Operation
Before going to bed, you can simply press the SLEEP button and unit will operate in SLEEP mode and bring you a sound sleep. Use of SLEEP function After the unit starts, set the operation status, then press SLEEP button before which the clock must be adjusted and time being set. Operation Mode
1. In COOL,DRY mode 1 hours after SLEEP mode starts, temp. will become 1OC higher than temp. setting. After another 1 hours, temp. rises by 1OC further. The unit will run for further 6 hours then stops. Temp. is higher than temp. setting so that room temperature won't be too Iow for your sleep.
Remote Controller
SLEEP operation starts SLEEP operation stops
Approx.6hrs
Rises 1OC
1 hr
Rises 1OC
1 hr
Temp.setting
In COOL, DRY mode
Unit stop
2.3.In HEAT mode 1 hours after SLEEP mode starts, temp will become 2 OC lower than temp. setting. After another 1 hours, temp decrease by 2 OC further. After more another 3 hours, temp. rises by 1OC further. The unit will run for further 3 hours then stops. Temp. is lower than temp. setting so that room temperature won't be too high for your sleep.
Temp.setting
1 hr
1 hr
SLEEP operation starts
Decreases 2OC
Decreases 2OC
3 hrs
In HEAT mode
Unit stop
3 hrs
Rises 1OC
SLEEP operation stops
FRESH
STERILIZE
In AUTO mode The unit operates in corresponding sleep mode adapted to the automatically selected operation mode.
4. In F AN mode It has no SLEEP function.
5.Set the wind speed change when sleeping If the wind speed is high or middle before
setting for the sleep, set for lowing the wind speed after sleeping. If it is low wind, no change.
6.Note to the compensation for the power out:
press the sleep button ten times in five seconds and enter this function after hearing four sounds. And press the sleep button ten times within five seconds and leave this function after hearing two sounds.
With the power-our compensation, when settin g
NOTE:
the TIMER ON, TIMER OFF and TIMER ON/OFF, itís m emorized as shutdown status when resuming after power out.
17
Operation
Timer On/Off Operation
Set clock correctly before starting TIMER operation.
Remote Controller
FRESH
STERILIZE
1. After unit starts, select your desired operation mode Operation mode will be displayed on LCD.
2. Timer mode selection Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: Remote controller:
Then select your desired TIMER mode (TIMER ON or TIMER OFF). " "or " "will flash.
3.T ime setting
Press HOUR button. Every tim e the button is pressed, time setting increases 1 min, if kept depressed, it will increase rapidly. Every tim e the button is pressed, time setting decreases 1 min, if kept depressed, it will decrease rapidly. It can be adjusted within 24 hours.
BLANK
TIMER ON TIMER OFF TIMER ON-OFF
4.Confirming your setting
After setting correct tim e, press SET button to confirm " "or" "on the rem ote controller stops flashing. Time displayed: Unit starts or stops at x hour x min. (TIMER ON or TIMER OFF).
5.Cancel TIMER mode
Just press TIMER button several times until TIMER mode disappears.
Hints: After replacing batteries or a power failure happens, time setting should be reset. Remote controller possesses memory function, when use TIMER mode next time, just press SET button after mode selecting if time setting is the same as previous one.
18
Operation
Timer On-Off Operation
Set clock correctly before starting TIMER operation.
Remote Controller
FRESH
1. After unit starts, select your desired operation m ode Operation mode will be displayed on LCD.
2. Timer mode selection Press TIM ER button to change TIMER mode. Every time the button is pressed, display changes as follows: Remote controller:
Then select your desired TIM ER mode (TIMER ON - OFF). " "will flash.
3.Tim e setting
BLANK
TIMER ON TIMER OFF TIMER ON-OFF
Press HOUR button. Every time the button is pressed, time setting increases 1 min, if kept depressed, it will increase rapidly. Every time the button is pressed, time setting decreases 1 min, if kept depressed, it will decrease rapidly. It can be adjusted within 24 hours.
STERILIZE
4.Timer confirming for TIMER ON After setting correct time, press TIMER button to confirm
" " on the remote controller stops flashing. " " starts flashing. Time displayed: Unit starts or stops at x hour x min.
5.Time setting for TIMER OFF Just press HOUR button ,follow the same procedure in "Time setting for TIMER ON"
6.Time confirming for TIMER OFF After time setting,press SET button to confirm.
To cancel TIMER mode
Just press TIMER button several times until TIMER de disappears. According to the Time setting sequence of TIM ER ON or TIMER OFF, either Start-Stop or Stop-Start can be achieved.
19
Operation
POWER/SOFT Operation
POWER Operation
When you need rapid heating or cooling, you can use this funciton.
Selecting of POWER operation
Press POWER/SOFT button. Every time the button is pressed,display
changes as follows:
Stop the display at
In PO WER operation status:
In HEAT or COOL mode, fan speed automatically runs in HI mode f or 15 min then returns to original status setting.
To cancel POWER operation
Press POWER/SOFT button twice ,POWER/SOFT disappears.
POWER
BLANK
SOFT
SOFT Operation
You can use this function when silence is needed f or rest or reading.
Selecting of SOFT operation
Press POWER/SOFT button. Every time the button is pressed,display
changes as follows:
POWER
Stop the display at
In SOFT operation mode, f an speed automatically takes"LOW"
SOFT
To cancel POWER operation
Press POWER/SOFT button twice ,POWER/SOFT disappears. Hints:
During POWER operation, in rapid HEAT or COOL mode, the roor will show inhomogeneous temperature distribution. Long period SOFT operation will cause effect of not too cool or not too warm.
NOTE: The f unctions of Power/Soft are only for the units of
HSU-07HV03/R2(DB) HSU-09HV03/R2(DB) HSU-12HV03/R2(DB)
HSU-18HV03/R2(DB)
20
BLANK
Operation
Health a irflow Operation
Remote controller
FRESH
STERILIZE
1.Press ON/OFF to starting
The liquid crystal will display the working state of last time (Except timer, sleeping, power/soft and health airflow). Setting the comfort work conditions.
2.T he setting of health airflow function
1).Press the button of health airflow, appears on the display. The nether inlet and outlet grills of the air condit­ioner are closed and the airflow is blown horizontally from the above inlet and outlet grills. Avoid the strong airflow blows direct to the body.
2).Press the button of health airflow again, appears on the display. The above inlet and outlet grills of the air cond­itioner are closed and the airflow is blown vertically from the nether inlet and outlet grills. Avoid the strong airflow blows direct to the body.
3.T he cancel of the health airflow function
Press the button of health airflow again, both the inlet and outlet grills of the air conditioner are opened, and the unit goes on working under the condition before the setting of health airflow function. After stopping, the outlet grille will close autom atically. Notice: Cannot pull direct the outlet grille by hand. Otherwise, the grille will run incorrectly. If the grille is not run correctly, stop for a minute and then start, adjusting by remote controller.
Note: 1 .After setting the health airflow function, the position of inlet and outlet grills is fixed.
2.In heating, it is better to select the mode.
3.In cooling, it is better to select the mode.
4.In cooling and dry, using the air conditioner for a long tim e under the high air humidity, a phenomenon falling drips of water occurs at the outlet grille .
5.Select the appropriate fan direction according to the actual conditions.
21
Operation
Emergency and Test Operation
Emergency operation:
Use this operation only when the remote controller is defective or lost.
In this operation, the system automatically selects the operation modes, cooling or heating, according to the room temperature.
T emperature
ABOVE 23OC BELOW 23OC
It is not possible to operate in dry mode.
Operation mode
COOLING HEATING
Designated temperature
26OC
23OC
T imer mode
NO NO
Air flow
AUTOMA TIC AUTOMA TIC
Test operation:
Test operation switch is the same as emergency switch.
Use this switch in the test operation when the room temperature is below 16OC, do not use it in the normal operation.
Continue to press the test operation switch for more than 5 seconds. After you hear the "Pi" sound twice, release your finger from the switch: the cooling operation starts with the air flow speed "Hi".
After 30 minutes, test operation ends automatically.
Removal of the restriction of emergency or test operation
Press the emergency operation switch once more, or manipulate through the remote controller; the "Pi" sound, the emergency or test operation is terminated.
When the remote controller is manipulated, it gets the system back to the normal operation mode.
22
Maintenance
For Smart Use of The Air Conditioner
Setting of proper room temperature
Proper temperature
Close doors and windows during operation
During cooling operation prevent the penetration of direct sunlight with curtain or blind
Do not b lock the air inlet or outlet
Use the timer effectively
If the unit is not to be used f or a long time, turn off the power supply main switch.
OFF
Use the louvers effectively
23
Maintenance
For Smart Use of The Air Conditioner
WARNING
Before maintenance,be sure to turn off the system and the circuit breaker.
Remote Controller
Do not use water, wipe the controller with a dry cloth.Do not use glass cleaner or chemical cloth.
Do not use the following for cleaning
Gasoline,benzine, thinner or cleanser m ay damage the coating of the unit.
Air Filter cleaning
Open the inlet grille by pulling it upward.
Indoor Body
Wipe the air conditioner by using a soft and dry cloth.For serious stains,use a neutral detergent diluted with water.Wring the water out of the cloth before wiping.then wipe off the detergent completely.
Hot water over 40OC(104OF) may cause discoloring or deformation.
Remove the filter.
Push up the filter's center tab slightly until it is released from the stopper, and remove the filter downward.
Clean the filter.
Use a vacuum cleaner to remove dust, or wash the filter with water.After washing, dry the filter com pletely in the shade.
Attach the filter.
Attach the filter correctly so that the "FRONT" indication is facing to the front.Make sure that the filter is completely fixed behind the stopper.If the right and left filters are not attached correctly, that may cause defects.
Close the inlet grille.
24
Once every two weeks
Maintenance
Replancement of Air Purifying Filter
1.Open the lnlet Grille
Open the inlet grille b y pushing each ends of the inlet grille upward.(use thumbs to push up)
2.Detach the standard air filter
Slide the knob slightly upward to release the filter, then withdraw it.
3.Attach old Air Purifying Filter
Put air purifying filter appliances into the right and left filter frames.
Detach old Air Purifying Filter
The green aspect of the bacteria-killing medium
4.Attach the standard air filter
(Necessary installation)
5.Close the Inlet Grille
Close the Grille surely
air purifying filter will face outside, the white aspect will face to the machine.
Note: the bacteria-killing mediums placed on the left side. the multi-lights touching intermediary is placed on the right side.
Common sense:
1.For the units with UV light degerming function,the air purifying filter of the bacteria-killing medium and the multi-lights touching interm ediary is effective for a long time and don't need to be changed (UV light emitted by the UV light device of the indoor unit catalytically activates the nano TiO2 on the multi-lights touching intermediary, and the degerming effect is highly efficient and lasting. multi-lights touching intermediary don't need to be exposed to the sunlight.).
2.For the units without UV light degerming function,the air purifying filter of the m ulti-lights touching intermediary will be solarized in fixed time. In normal family,it will be solarized every 6 months. The solarization time will last no less than 8 hours under the state of abundant sun.
3.But in the use, please note to clean the filter frequently (take off the back suction cleaner or lightly pat it) to avoid the operating effect is lowered due to the dust covering the filter. Multi-lights touching intermediary and bacteria-killing medium filter is strictly prohibited from being cleaned by water.
The the bacteria-killing medium filter not in use should be stored in shade, cool and dry place. Please don't expose it to the sunlight for a long time otherwise the degerming performance will drop.
25
Maintenance
To Keep Your Air conditioner in Good Condition after Season.
Operate in cooling mode f or 2-3 hours.
To prevent breeding mold or bad smell, be sure to operate at the designated temperature or 30OC,cooling mode and High speed fan mode for 2-3 hours.
Put off the power supply cord.
Cleaning the body.
Take out the batteries from the wireless remote controller.
2 6
Maintenance
Before Setting in High season
Cleaning the standard air filter.
Operation without filter ma y cause troubles.Be sure to attach both right and left filters prior to the operation. Each of them are of different shapes.
Connecting the earthing cable.
Caution
Incomplete earthing ma y cause an electric shock.
Do not block the air inlet or outlet.
Plug-in
Caution
After brush awa y dust at the plug, insert the plug of the power supply cord into the outlet completely.In case of suing e xclusive circuit breaker,switch on the circuit breaker.
EARTHING
NO WET HAND
27
Trouble shooting
Before asking for service, check the following first.
Normal Performance inspection
Phenomenon
The system does not restart immediately.
Noise is heard:
Smells are generated.
Mist or steam are blown out.
Cause or check points
When unit is stopped, it won't restart immediately until 3 minutes have elapsed to protect the system. When the electric plug is pulled out and reinserted, the protection circuit will work for 3 minutes to protect the air conditioner.
During unit operation or at stop, a swishing or gurgling noise may be heard. At first 2-3 minutes after unit start, this noise is more noticeable. (This noise is generated by refrigerant flowing in the system .) During unit operation, a cracking noise m ay be heard. This noise is generated by the casing expanding or shrinking because of tem perature changes. Should there be a big noise from air flow in unit operation, air filter may be too dirty.
This is because the system circulates sm ells from the interior air such as the smell of furniture, cigarettes.
During COOL or DRY operation, indoor unit may blow out mist. This is due to the sudden cooling of indoor air.
Multiple check
Does not work at all.
Poor cooling
Is power plug inserted? Is there a power failure? Is fuse blown out?
Is the air filter dirty? Normally it should be cleaned e very 15 days. Are there an y obstacles before inlet and outlet? Is temperature set correctly? Are there some doors or windows left open? Is there any direct sunlight through the window during the cooling operation?(Use curtain) Are there too much heat sources or too many people in the room during cooling operation?
2 8
AIRE ACONDICIONADO TIPO SPLIT
MANUAL DE
FUNCIONAM IENTO
Leer detenidamente es te manual de func ionamiento antes de util izar el aire acondicionado.
Loading...