HYPERSTEAM PRESSURELESS STEAMER
PROJECT NAME:
LOCATION:
ITEM NO:
MODEL HY-6SG-36
Steamer shall be a Groen HyPLUS™ Model HY-6SG-36 stainless steel twin cavity 6 pan pressureless steamer,
with cabinet mounted 200,000 BTU gas steam boiler, per Bulletin 77Bb and as follows.
CONSTRUCTION: Steamer cavities and cabinet
base shall be all stainless steel construction. Steamer unit
shall have a unitized body, with removable right side panel
providing access to internal components. Steamer doors are
all stainless steel with strong continuous hinge and are field
reversible for left or right swing. Doors shall be insulated
and provided with a one-piece, replaceable seal. Easy
open handle and latch shall provide positive lock and seal
when door is pushed or slammed shut. Hidden magnetic
door switch cuts power to blower and steam flow to that
cavity, when the door is opened. Pan support racks shall be
polished stainless steel and removable for easy cleaning.
Wide drip sink with condensate drain is positioned under
cavity doors. 36” wide cabinet base shall have stainless steel
frame with all stainless steel top deck, with hinged front
access panel and removable side and rear panels standard.
Front and rear legs shall have adjustable bullet feet. Flanged
feet are an available option.
steamer cavity shall have a powerful side mounted blower,
which increases steam velocity and provides efficient steam
distribution throughout cavity and between loaded pans.
CABINET BASE STEAM SOURCE: Unit
shall have a gas heated cabinet mounted pressure boiler
to provide atmospheric steam to each chamber at a
temperature of approximately 212°F. The 200,000 BTU
generator delivers 3.7 boiler horsepower. Unit comes
standard with electronic ignition.
PAN CAPACITY:
Pan Size/Type Per cavity Total
12 x 20 x 1” 6 12
12 x 20 x 2 1/2” 3 6
12 x 20 x 4” 2 4
QTY:
MODEL NO:
AIA NO:
SIS NO:
6-Pan capacity stainless steal
pressureless steamer, with gas
pressure boiler in cabinet base.
(model HY-6SG-36 shown)
FINISH: Cabinet exterior including doors shall be finished
to a #3 uniform finish. Cavity interiors are polished stainless
steel. Control panel face plates shall be smudge resistant
polyester film, ensuring maximum ease in cleaning and
maintaining a brilliant finish.
ASME CODE & UL LISTING: Cabinet mounted
boiler shall be ASME Code constructed and National Board
registered for operation up to 15 PSI. Gas pressure boiler to
be AGA Design Certified. Steamer shall be UL listed.
SANITATION: Unit shall be designed and constructed
to meet NSF and known health department and sanitation
codes and be NSF listed.
CONTROLS: Steamer cavity controls shall be mounted
on the front panel for easy replacement or repair and will
include separate ON-OFF/60 minute timer control with
constant steam setting, for each cavity. Electric boiler shall be
provided with a power-ON switch, RESET light, start switch,
low water sensor, pop safety valve, water level sight glass
and outside cabinet mounted pressure gauge.
PERFORMANCE FEATURES:
water level is low or unit builds too much pressure. When power
switch is turned “off,” the boiler automatically drains to reduce
sediment build-up, after water has cooled to 170°F. Each
Unit will shut off if
INSTALLATION: Unit requires gas service via 1/2”
NPT pipe or approved equivalent. Specify type of gas.
Unit requires 1/2” NPT cold water supply line; 11/4” NPT
free venting drain; and 115 volt, single phase, 60 cycle
15 AMP electric service, 4 AMP maximum load.
STEAM SOURCE FOR ADJACENT
EQUIPMENT:
shall be standard. To ensure proper performance, boiler
must be properly sized to meet boiler horsepower
requirements of steamer cavities AND additional
equipment. Appropriate steam traps and piping must be
professionally installed.
A 1/2” NPT power take-off valve
WATER SUPPLY REQUIREMENTS:
All water boiler systems are subject to contamination
and failure due to mineral content found in most
water supplies. To minimize service problems, a water
treatment (softening) system is recommended when
water quality is found to exceed limits stated below and
in operator manual. Recommended MINIMUM water
quality standards are: Total dissolved solids (TDS) content
should not exceed 30 parts per million; and the water pH
should be 7.0 to higher.
ORIGIN OF MANUFACTURE: Designed and
manufactured in the United States.
OPTIONS/ACCESSORIES:
Flanged mounting feet
Independant water supply to
consensate spray
HyPerSteam
160178 RevB
Revised 04/11
30
(76)
5
8
3
)
1
2
2
(64)
4
3
21
16
(538)
SEE NOTE 1
7
16
(192)
HY-6SG-36
1
21
4
(540)
1
18
2
(470)
9
1
14
(365)
FLUE
3
18
16
(462)
2
5
3
6
3
8
CONDENSATE
DRAIN VENT
4
CLEARANCE
SEE NOTE 1
6
(152)
NATURAL
PROPANE
RECOMMENDED
INCOMING GAS PRESSURE
5" W.C. (MIN.)
14" W.C. (MAX.)
11" W.C. (MIN.) 14" W.C. (MAX.)
*
INCHES WATER COLUMN
INPUT RATE (BTU/HR.): 200,000
P/N 121511 REV D
OPERATING
*
GAS PRESSURE
*
3.5" W.C.
10.0" W.C.
OUTPUT RATE (BTU/HR.): 120,000
CLEARANCECLEARANCE
SEE NOTE 1
24
(51)(102)
BOILER HORSEPOWER: 3.7
3
57
16
(1453)
9
26
16
(675)
5
4
(117)
8
36
(918)
1
8
1
2
1
2
5
(67) MAX.
8
(38) MIN.
SERVICE CONNECTIONS:
DRAIN CONNECTION: 1-1/4" NPT
1
(INCLUDES AUTOMATIC & MANUAL BOILER, STEAMERS, & CONDENSATE SPRAY)
2
COLD WATER SUPPLY: 1/2" NPT (FOR BOILER & CONDENSATE SPRAY)
3
OPTION: SEPARATE CONDENSATE SPRAY 3/8" NPT (ADD KIT #MS102210)
4
ELECTRICAL CONNECTION: 7/8" DIA. HOLE (REF. 1/2" CONDUIT KNOCK-OUT)
5
GAS CONNECTION: 1/2" NPT
6
STEAM POWER TAKE-OFF: 1/2" NPT
NOTES:
1. MINIMUM CLEARANCE FROM COMBUSTIBLE MATERIALS
RIGHT SIDE 2" (51)
LEFT SIDE 4" (102)
REAR 6" (152)
2. DIMENSIONS IN BRACKETS ( ) ARE MILLIMETERS.
ADJUSTABLE
BULLET FEET
34
(868)
6
3
2
1
23
16
(586)
7
3
4
11
9
16
(246)
3
16
TREATED
WATER
SUPPLY
CONN.
OF WATER CONNECTIONS
(IF SECOND CONNECTION ORDERED)
(98)
1
(51)
UN-TREATED
WATER
SUPPLY
CONN.
(OPTIONAL)
DETAIL VIEW
8
5
2
24
(618)
5
16
121511 REV D
1055 Mendell Davis Drive, Jackson, MS 39272, 888-994-7636, unifiedbrands.net
© 2013 Unified Brands. All Rights Reserved. Unified Brands is a wholly-owned subsidiary of Dover Corporation.