Greyline Instruments VSJ Data sheet

BAND ADJUSTMENT
JACK
Data Sheet
VSJ Pipe Mounting Bands
for Submersible Sensors
Use optional VSJ stainless steel Pipe Mounting Bands for easy Sensor installation in round pipes.
Each Pipe Band includes:
!
Band Adjustment Jack allowing ±0.5” (13 mm) adjustment from the nominal band size.
: VSJ6 and VSJ8 bands do not include adjustment jacks
Note
- they secure to pipe by spring tension.
!
Stainless steel bracket for Sensor mounting
!
Pre-drilled for tie wraps (included) to secure Sensor cable
CODE BAND SIZE
VSJ6 6”/150 mm ID pipes (without adjustment jack) VSJ8 8”/200 mm ID pipes VSJ10 10”/250 mm ID pipes VSJ12 12”/300 mm ID pipes VSJ14 14”/350 mm ID pipes VSJ15 15”/375 mm ID pipes VSJ16 16”/400 mm ID pipes VSJ18 18”/450 mm ID pipes VSJ20 20”/500 mm ID pipes VSJ24 24”/600 mm ID pipes VSJ30 30”/750 mm ID pipes
(without adjustment jack)
Mounting Instructions:
Install the stainless steel pipe band with the sensor mounting bracket at the invert (bottom) of the pipe. Ensure that the sensor bracket is parallel to the water surface (check with a level). Mount so the tapered end of the sensor will point upstream and the sensor cable will point downstream. Turn the ¼” hex nut clockwise to expand the bracket and secure to the pipe wall by friction fit.
Insert the sensor into the mounting bracket and clip or tie wrap the sensor cable securely to the stainless steel pipe band.
FASTEN SENSOR CABLE TO PIPE OR CHANNEL WITH METAL CLIPS OR TIE WRAPS
END VIEW
SENSOR