Greyline Instruments Stingray Specifications

Portable Level-Velocity Logger
Area-Velocity Flow Measurement in Open Channels and Pipes
Level-Velocity
Logger
Stingray 2.0
Logs Level and Velocity
for Flow Studies
Includes powerful
Flow analysis and reporting
Portable, Battery-powered
Streamlined Ultrasonic Sensor
Measures Level, Velocity + Temperature
in Open Pipes and Channels
This compact new meter operates on standard alkaline batteries for extended time periods to data log level, velocity and water temperature in open channels, partially full sewer pipes and surcharged pipes a flume or weir. It is designed forwithout municipal stormwater, combined effluent, raw sewage, irrigation water and stream flow.
Stingray 2.0 uses a hydrodynamic ultrasonic sensor to accurately measure both velocity and level in the channel. The submerged sensor has no moving parts and is resistant to fouling and corrosion.
RELIABLE MEASUREMENT AND CONTROL
Portable Area-Velocity Meter
Logging Interval
Log Duration
Battery Life
10 sec
15 days
15 days
30 sec
45 days
45 days
1 min
3 months
3 months
2 min
6 months
6 months
5 min
1 year
1 year
10 min
2 years
2 years
15 min
3 years
3 years
30 min
4 years
4 years
60 min
4 years
4 years
Stingray 2.0 measures evel and elocity in open channels or pipes. No calibration is required. The sensorlv
is a completely sealed ultrasonic unit with no orifices or ports. It mounts inside the pipe or at the bottom of a channel. The watertight electronics enclosure is hung in the manhole or at a convenient location. Sensor, mounting bracket, batteries, software and cables are included with each Stingray.
Powered by Standard Alkaline Batteries and Operates up to Four Years!
With 4 D-cell Alkaline batteries the Stingray 2.0 will operate up to 4 years! These low-cost batteries are available in stores everywhere and with an extremely low self discharge rate they will reliably power the energy-efficient Stingray 2.0 for the duration of your flow study.
Stores 130,000 Data Points
Stingray 2.0 stores up to 130,000 data points including level, velocity and water temperature. Between readings it hibernates to conserve energy.
USB Data Download
Connect your laptop or to thePC Stingray’s output to view realtimeUSB level and velocity readings, view
Stingray Installed in a Stream Flow Application
remaining logger and battery capacity and to set the Stingray 2.0 logging interval.
Greyline Logger Software
Powerful Windows software is included free with each Stingray 2.0. Use it to set the logger interval, to download log files and view Level, Velocity and water temperature readings in real-time.
Greyline Logger will display log files and flow rates in graph and table formats. It will generate flow reports including minimum, maximum and average flow, calculate flow totals, and convert between common measurement units.
Reporting is easy with Greyline Logger software - you can export charts as image files and export data to use in spreadsheet or database programs.
Retrieve a Log file from Stingray 2.0
+=
'Generate Flow Log'
Click
Greyline Logger calculates Flow
Calculate flow
with Greyline
Logger software
Stingray 2.0 Specifications
General Specifications
Electronics Enclosure:
Accuracy:
Display:
Operating Temp. (electronics):
Instrument Set-up:
Logger Interval:
Data Logger Capacity:
Power:
Output/Communications:
USB Cable:
Software:
Approximate Shipping Weight:
QZ02 SensorL
Velocity Measurement Range:
Level Measurement Range:
Operating Temperature:
Exposed Materials:
Sensor Cable:
Sensor Mounting:
Temperature Compensation:
Options
Sensor Cable Extension: Sensor Mounting Bands:
Extended Temperature Sensor:
Greyline Stingray 2.0 Level-Velocity Logger
Watertight, airtight, dust proof ( 67) polycarbonateIP Level: ±0.25% of Range. Velocity: ±2% of Reading LCD displays: Level, Velocity, Water Temperature, Battery and Memory capacity
-4° to 140°F (-20° to 60°C) via Greyline Logger software for Windows: Logging Time Interval, Site Name 10 sec (15 days), 30 sec (45 days), 1 min (3 months), 2 min (6 months), 5 min (1 year), 10 min (2 years), 15 min (3 years), 30 min (4 years) or 60 min (4 years) 130,000 data points 4 Alkaline 'D' cell batteries USB 3 1 shieldedft ( m) Greyline Logger for Windows. Supports real-time monitoring, log file download and export, graph and data table presentation, level/velocity to flow conversion 10 lbs. (4.5 kg)
0.1 to 1 ft/sec (0.03 to 3. m/sec)2.5 8 Minimum Head: 1 in (25.4 mm). Maximum Head: 15 ft. (4.5 m) 5 to 150°F (-15 to 65°C) PVC, polyurethane, epoxy 25 ft. (7.6 m) submersible polyurethane jacket, shielded, 3-coaxial includes - stainless steel mounting bracketMB QZ Automatic, continuous
shielded 50 ft. (15 m) submersible, polyurethane jacket with watertight connectors Stainless steel sensor mounting bands for pipes from 6” to 72” (150 to 1800 mm) QZ HT CPVC02L- , construction rated to 175°F (80°C)
Dimensions
25 ft / 7.6 m length
QZ PS VELOCITY LEVEL SENSOR02L- -01- /UT
SIDE VIEW
1mm25
0.50"
12.7 mm
4. "92
0.63" 16 mm
1.50"
38.1 mm
9.12"
232 mm
4.37"
111 mm
7.56"
192 mm
Stingray 2.0
ELECTRONICS ENCLOSURE
New Portable Level-Velocity Logger
for Flow Surveys in Sewers, Streams and Open Channels
Use Stingray 2.0 for:
!
Flow Surveys
!
Inflow & Infiltration Studies
!
CSO Monitoring
!
Stormwater Runoff
!
Irrigation Water
!
Permit Compliance
!
Wastewater Treatment Plant Flow Studies
SENSOR
LEVEL
VELOCITY
FLOW
SUBMERGED ULTRASONIC SENSOR MEASURES LEVEL AND VELOCITY
Easy to Operate
No calibration is required. Just install the sensor at the bottom of the pipe or channel and the Stingray 2.0 logs level and velocity readings. Use Greyline Logger software (included) to set the logging interval, and to view readings in real-time on your laptop or . StingrayPC
2.0's built-in display lets operators check levelLCD and velocity rates, remaining battery life and logger memory.
Built-in Display for Operator Confidence
Operators can check operation with the built-in LCD bar graph display. It scrolls through level, velocity and temperature readings, plus remaining battery and logger storage capacity. The display turns off automatically after 60 seconds to conserve battery power.
How it Works
The sensor transmits ultrasonic pulses that travel through the water and reflect off the liquid surface. To monitor water level, the Stingray 2.0 precisely measures the time it takes for echoes to return to the sensor.
Velocity is measured with an ultrasonic signal continuously injected into the flow. This high frequency sound is reflected back to the sensor from particles or bubbles suspended in the liquid. If the fluid is in motion, the echoes return at an altered frequency proportionate to flow velocity. The Stingray 2.0 uses this Doppler frequency shift to accurately calculate flow velocity.
How to Order
Applications Support
No Risk Appraisal
The Greyline
Guarantee
Canada: 16456 Sixsmith Dr., Long Sault, Ont. K0C 1P0
Tel: 613-938-8956 / 888-473-9546 Fax: 613-938-4857
USA NY: 105 Water Street, Massena 13662
Tel: 315-788-9500 / 888-473-9546 Fax: 315-764-0419
Internet: www.greyline.com E-mail: info@greyline.com
Contact a Greyline sales representative in your area or phone one of our sales engineers. Describe your requirements and receive our prompt quotation.
Take advantage of Greyline's applications experience. Phone toll free 1-888-473-9546 for advice on applications, installation or service for Greyline instruments.
The Stingray 2.0 Velocity Meter must meet your requirements. Discuss yourLevel­application with a Greyline representative to arrange a performance test.
Quality of Materials and Workmanship - Each instrument manufactured by Greyline is warranted against defects in materials and workmanship for a period of one year from date of purchase. Refer to our limited warranty included with each product.
RELIABLE MEASUREMENT AND CONTROL
Loading...