Greyline Instruments SE4-A Specifications

Doppler Sensor SE4
Model SE4 Doppler Sensor
1.5” 38 mm
1.375”
35 mm
SPECIFICATIONS:
Minimum Pipe Diameter: 0.5" (12.5 mm) ID, 0.6" (15 mm) OD
Maximum Pipe Diameter: 180" (4.5 m) ID
Operating Temperature: -40° to 248°F (-40° to 120°C)
Operating Frequency: 640 Khz
Sensor Housing: Stainless Steel with Polyimide face
Sensor Cable: 20 ft. (6 m) shielded coaxial pair (RG174U)
Submersion Rating: Withstands accidental submersion pressure up to 15 psi (1 Bar)
Hazardous Locations: Approvals pending
NOTES:
1. Refer to the instruction manual for detailed mounting instructions.
2. Locate >6 pipe diameters from Elbows or Tees.
3. Locate >30 pipe diameters from pumps, controlling valves, orifice plates or venturis.
4. Mount with Coupling Compound (supplied) and secure with self-aligning stainless steel Pipe Clamp (supplied with flowmeter).
5. Extend Sensor cable with Greyline option DXC shielded dual coaxial cable only. Self-tunes to maximum cable length of 500 ft (152 m).
7. Submersion rating is for accidental, temporary flooding. Doppler accuracy may be affected while SE4 Sensor is submerged.
3.375” / 85 mm
Optional 50 ft (15 m) or 100 ft (30 m) continuous
20ft/6m
Loading...