Data Sheet
PZ12-LP Low Profile Ultrasonic Sensor
25 ft (7.6 m)
Coaxial Cable
3.12"
79.2 mm
0.218 DIA
(5.5 mm)
3.00"
76.2 mm
FACE
VIEW
SIDE
VIEW
0.25 DIA
(6.35 mm)
3.00"
76.2 mm
4.00"
101.6 mm
0.62"
15.75 mm
SPECIFICATIONS:
Maximum Range: 12 ft (3.66 m)
Minimum Range (deadband): 8" (203.2 mm)
Operating Frequency: 92 KHz
Beam Angle: 8°
Operating Temperature: -40° To 150°F (-40° To 65°C)
Temperature Compensation: Automatic, Continuous
Max. Operating Pressure: 20 Psi (1.35 Bar)
Sensor Face: PVC
Sensor Body: PVC
Mounting: MB12 Stainless Steel Mounting Bracket
(included)
Cable Length: 25 Ft. (7.6 M) continuous RG62AU coaxial
Optional 50 ft. (15 m) continuous
Max. Cable Length: 500 ft. (152 m) RG62AU
Hazardous Rating:
CSA rated Intrinsically Safe Class I,
Groups C,D, Class II, Groups E,F,G with
optional Intrinsic Safety Barrier.
coaxial (splice)
0.68"
17.3 mm
MB12 - MOUNTING BRACKET
(Stainless Steel - included)
NOTES:
1. Shield from direct sunlight (Temp. probe in sensor).
2. Run sensor cable in grounded metal conduit with no other
conductors.
3. Extend sensor cable with RG62AU coaxial only. Splice with
terminal strip connections in recommended Junction Box.
4. Refer to the instruction manual for complete installation and
wiring information.