Greyline Instruments PTFM-1.0 Specifications

Portable Transit Time Flow Meter
with Clamp-on Ultrasonic Transducers
Portable Ultrasonic
Flowmeter
Model PTFM 1.0
Displays, Totalizes
TransmitsData Logs and
Backlit LCD Display
5Simple -key Calibration
Built-in Rechargeable Battery
Built-in Data Logger
14 Digit Totalizer
4-20mA Output
Non-Contacting Flow
Measurement
Accurate Flow Measurement of Clean Liquids
with Non-Contacting Transducers
Recommended for fluids like water, glycol, oil and most chemicals. The PTFM 1.0 transducersultrasonic strap-on the outside of pipes from 2 to ( to 00 mm) diameter. The ultrasonic signal skrow2184" " 50
srecudsnarThguorht all common metal and plastic pipe materials. can be mounted without shutting down flow and there is no obstruction or pressure drop.
e tsuJCalibration is easy with the onscreen menu system. nter the pipe diameter, wall thickness and pipe material he. T PTFM 1.0 is powered by an internal, rechargeable NiMH battery or can be operated continuously with AC power adapter. Each PTFM 1.0 includes a watertight carry case, transducer set, cables and mounting clamps.
RELIABLE MEASUREMENT AND CONTROL
www.greyline.com
Portable Ultrasonic Flowmeter
for Troubleshooting, Calibration Checks
and Balancing Flow
Measures Flow Outsidefrom the of a Pipe
The PTFM 1.0 Portable Transit Time Flow Meter works by measuring the “transit time” or
“time of flight” for ultrasonic sound pulses transmitted from one transducer to another.
transit time in the direction of flow is faster than the transit time against the flow. By comparing these differences with precision timing circuits, the PTFM 1.0 is able to accurately calculate the flow rate
Choice of V, Z or W mounting method depends on the application and pipe diameter. V­Mount is the most common method while Z-Mount is used for larger pipes or weak signal applications and W-Mount for smaller pipes.
.
The
V-Mount
Works Common Pipe Materialswith
Mount the ltrasonic transducers on the outside of metal oru plastic pipes including carbon steel, stainless steel, ductile iron, cast iron, ,PVC, PVDF, fiberglass, copper, brass aluminum and pipes with bonded liners including epoxy, rubber and Teflon. Avoid pipes made with porous materials (e.g. wood or concrete) or with loose insertion liners.
Measures in Full PipesClean Liquids
The PTFM 1.0 Portable Transit Time Flow Meter is designed clean, non-aeratedto measure liquids .like water, chemicals and oils with less than 2% solids or bubbles The ultrasonic transducers can be mounted on vertical or horizontal pipes.
Simple Menu System for Start-up and CalibrationEasy
Calibration and start-up can be done in a few minutes. Use the built-in 5-button keypad to enter the pipe material and OD, wall thickness and fluid type. The PTFM 1.0 will display the correct transducer separation distance. Secure the stainless steel pipe clamps and align the mounting brackets on the outside of the pipe. Put coupling compound ( ) on theincluded transducer faces insert them into the mounting brackets The PTFM 1.0 will immediatelyand . begin to display, transmit and totalize flow.
Built-in Data Logger with Windows Software Included
Z-Mount
W-Mount
Set up the data logger to store time and300,000 point date-stamped flow from 1 second to minutereadings 0 5 intervals. the convenient 'Flow Report'View on-screen where total, minimum, maximum and average flow rates are stored in daily summar .a 24 hour y
Transfer flow logs to your PC or laptop through the PTFM
1.0 USB t (included)'s outpu . Greyline Logger software displays data in both graph and table formats with one-click export to Microsoft Excel , images CSV files other programs.
® or for use in
Loading...
+ 2 hidden pages