Portable Transit Time Flow Meter
with Clamp-on Ultrasonic Transducers
Portable Ultrasonic
Flowmeter
Model PTFM 1.0
Displays, Totalizes
TransmitsData Logs and
Backlit LCD Display
5Simple -key Calibration
Built-in Rechargeable Battery
Built-in Data Logger
14 Digit Totalizer
4-20mA Output
Non-Contacting Flow
Measurement
User-Friendly Operating System
Accurate Flow Measurement of Clean Liquids
with Non-Contacting Transducers
Recommended for fluids like water, glycol, oil and most chemicals.
The PTFM 1.0 transducersultrasonic strap-on the outside of pipes
from 2 to ( to 00 mm) diameter. The ultrasonic signal skrow2184" " 50
srecudsnarThguorht all common metal and plastic pipe materials.
can be mounted without shutting down flow and there is no
obstruction or pressure drop.
e tsuJCalibration is easy with the onscreen menu system. nter the
pipe diameter, wall thickness and pipe material he. T PTFM 1.0 is
powered by an internal, rechargeable NiMH battery or can be
operated continuously with AC power adapter. Each PTFM 1.0
includes a watertight carry case, transducer set, cables and mounting
clamps.
RELIABLE MEASUREMENT AND CONTROL
www.greyline.com

Portable Ultrasonic Flowmeter
for Troubleshooting, Calibration Checks
and Balancing Flow
Measures Flow Outsidefrom the of a Pipe
The PTFM 1.0 Portable Transit Time Flow Meter works by measuring the “transit time” or
“time of flight” for ultrasonic sound pulses transmitted from one transducer to another.
transit time in the direction of flow is faster than the transit time against the flow. By
comparing these differences with precision timing circuits, the PTFM 1.0 is able to
accurately calculate the flow rate
Choice of V, Z or W mounting method depends on the application and pipe diameter. VMount is the most common method while Z-Mount is used for larger pipes or weak signal
applications and W-Mount for smaller pipes.
.
The
V-Mount
Works Common Pipe Materialswith
Mount the ltrasonic transducers on the outside of metal oru
plastic pipes including carbon steel, stainless steel, ductile
iron, cast iron, ,PVC, PVDF, fiberglass, copper, brass
aluminum and pipes with bonded liners including epoxy,
rubber and Teflon. Avoid pipes made with porous materials
(e.g. wood or concrete) or with loose insertion liners.
Measures in Full PipesClean Liquids
The PTFM 1.0 Portable Transit Time Flow Meter is designed clean, non-aeratedto measure
liquids .like water, chemicals and oils with less than 2% solids or bubbles The ultrasonic
transducers can be mounted on vertical or horizontal pipes.
Simple Menu System for Start-up and CalibrationEasy
Calibration and start-up can be done in a few minutes. Use the built-in 5-button keypad to
enter the pipe material and OD, wall thickness and fluid type. The PTFM 1.0 will display the
correct transducer separation distance. Secure the stainless steel pipe clamps and align the
mounting brackets on the outside of the pipe. Put coupling compound ( ) on theincluded
transducer faces insert them into the mounting brackets The PTFM 1.0 will immediatelyand .
begin to display, transmit and totalize flow.
Built-in Data Logger with
Windows Software Included
Z-Mount
W-Mount
Set up the data logger to store time and300,000 point
date-stamped flow from 1 second to minutereadings 0 5
intervals. the convenient 'Flow Report'View on-screen
where total, minimum, maximum and average flow rates
are stored in daily summar .a 24 hour y
Transfer flow logs to your PC or laptop through the PTFM
1.0 USB t (included)'s outpu . Greyline Logger software
displays data in both graph and table formats with one-click
export to Microsoft Excel , images CSV files
other programs.
® or for use in