Greyline Instruments OCF-6.1 Data sheet

I
OCF 6.1
OPEN CHANNEL FLOW & TANK LEVEL METER
Greyline
Precision Flow Measurement
An ON
CON Brand
THE RIGHT METER FOR
Flow Measurement with a Flume or Weir:
Inuent
Euent
• Sewers
• Irrigation
• Environmental
• Water
• Wastewater
• Chemicals
Features
Safe, Non-Contact Measurement
Simple 5-key Conguration
4-20mA/0-5V Output
26-Million Point Data Logger
On-Screen Flow Reports
Password Protected
Modbus® RTU Optional
Easy to Install and Calibrate. Simple, Accurate and Reliable.
Non-Contacting Sensor
The OCF 6.1 uses a non-contacting ultrasonic sensor mounted
over a ume or weir to measure ow, or inside/above a tank to measure level. It is accurate, reliable, and veriable. The separate, watertight electronics/display enclosure can be mounted within 500 ft (150 m) of the sensor. The OCF 6.1 continuously displays, totalizes, transmits, and data logs open channel ow or level.
Keypad Operating System
Use the built-in keypad for fast, easy conguration with menu selection of ume or weir and measurement units (e.g. gallons, liters, etc.) Conguration settings and data logs are password protected and retained during power interruptions. The OCF
6.1 will display on-screen ow or level reports with daily total, minimum, maximum, and average ow/level and will transfer data logs to a USB ash drive. PC software for easy report
generation is included.
888-473-9546 greyline.com
An ON
I
CON Brand
OCF 6.1
OPEN CHANNEL FLOW & TANK LEVEL METER
Greyline
Precision Flow Measurement
Built-in Data Logger Creates Flow Reports. Save time and labor — ow
information is stored automatically.
26-Million Point Data Logger
The OCF 6.1 󰏭ores time and date-󰏭amped ow values at programmable intervals of 10 seconds to 60 minutes. Daily reports are automatically created and can be viewed right on the in󰏭rument’s LCD display including total, minimum, maximum, and average ow rate or levels. Daily reports can also be downloaded easily to a USB drive in .csv format.
Easy Data Logger Downloads
You don’t need a laptop to retrieve log les! Plug any USB Flash Drive into the OCF 6.1 USB output to download data log les automatically. Downloaded les are sequentially named by the meter, so log les from the same or multiple in󰏭ruments can be 󰏭ored on one ash drive.
Greyline Logger Software for Windows
Greyline Logger is included with each OCF 6.1. This powerful software displays data in both graph and table formats. You can view ow and level data onscreen, generate reports, and save les to disk . Graphs can be exported as images and data tables can be exported as delimited text les, or directly to Microsoft Excel®.
Display, analyze, and export log les in graph and table formats
Generate reports including totalizer, minimum, maximum, and
average ow rates and level
Convert measurement units
One-click export to Microsoft Excel
®
®
Non-Contacting Ultrasonic Sensor
Each OCF 6.1 includes either a non-contacting PZ15 sensor designed for the special requirements of open channel ow measurement, or a PZ32T sensor designed for the special requirements of tank level measurement. The ultrasonic sensor beams are narrow enough to work on very small umes, and powerful enough for really large applications. The OCF 6.1 automatically tunes to extended cable lengths up to 500 ft (150 m) lengths.
OCF 6.1 Outputs Included
Connect the OCF 6.1’s isolated 4-20 mA output to external displays, chart recorders, or controllers and use the built-in relays for ow/level alarms and ow proportionate pulse to samplers, chlorinators or external totalizers.
Retains Memory during Power Interruptions
Date, time, calibration data, and user settings are 󰏭ored and retained in back-up battery protected memory. Data log les are in 󰏭ored Secure Digital (SD) non-volatile memory.
Security
Access to the OCF 6.1 calibration menu and settings are password protected when enabled.
888-473-9546
An ON
I
CON Brand
108 mm
PZ15 SENSOR
25 ft / 7.6 m RG62AU
(50 ft / 15 m or 100 ft
Isolation Coupling
PZ32T SENSOR
OCF 6.1
OPEN CHANNEL FLOW & TANK LEVEL METER
Greyline
Precision Flow Measurement
Technical Specications
GENERAL
Electronics Enclosure: Watertight and dust tight NEMA4X (IP 66) polycarbonate with clear, shatterproof cover
Accuracy: ±0.25% of measured range or 0.08” (2 mm) whichever is greater, Repeatability and Linearity: ±0.1%
Display: White, backlit matrix - displays ow rate, totalizer, relay status, operating mode, and calibration menu
Programming: built-in 5-key congurator with English, French or Spanish language selection
Power Input: 100-240 VAC 50-60 Hz (see Options), 10 VA max depending on options
Output: Isolated 4-20 mA/0-5 V, 1000 ohm load maximum, programmable oset
Control Relays:
Electrical Surge Protection:
Data Logger: Built-in 26-million point data logger with USB output and Windows
Operating Temperature (Electronics):
Approximate Shipping Weight:
Approvals CE, cCSAus
2 Relays, form ‘C’ dry contacts rated 5 amp SPDT; programmable level alarm, pump control, pump alternation, failsafe/ echo-loss, air temperature alarm
Sensor, 4-20 mA and AC power input
®
software.
-5° to 140°F (-20° to 60°C)
10 lbs (4.5 kg)
SENSOR
Maximum Range:
Deadband (Blanking): Programmable, Minimum 8 in (203.2 mm)
Beam Angle:
Operating Frequency: PZ15: 92 kHz; PZ32T: 42 kHz
Exposed Materials: PZ15: PVC; PZ32T: PVC and Teon
Operating Temperature:
Submersion Rating:
Sensor Cable:
15 ft (4.57 m) with standard PZ15 sensor 32 ft (10 m) with standard PZ32T sensor
-40° to 150°F (-40° to 65°C) with automatic temperature compensation
Protected for accidental submersion to 10 ft (3 m) maximum
RG62AU coaxial, 25 ft (7.6 m) standard length (See Options)
POPULAR OPTIONS
Industrial Automation Protocols:
Sensor Cable:
Intrinsic Safety Barriers:
Power Input: 9-32 VDC, 10 Watts max
Control Relays: 4 additional (6 total), rated 5 amp SPDT
Enclosure Heater:
Sunscreens:
Sensor Mounting Stand:
Modbus RTU via RS-485
50 ft (15 m) continuous or 100 ft (30 m) continuous RG62AU coaxial from Sensor, or splice up to 500 ft (150 m) with Junction Box
For Sensor mounting in Class I,II,III, Div. I,II, Groups C,D,E,F,G hazardous locations
Thermostatically controlled - recommended for temperatures below 32°F (0°C)
Sensor sunscreen and enclosure sunscreen for outdoor installations
Adjustable, includes galvanized steel pipe, anges, ttings and hardware
7.4” / 188 mm
6.46” / 164 mm 5.12” / 130 mm
OCF 6.1
PSL5.0
Open Channel
Pump Station
Flow Monitor
Level Controller
Conduit Entry Location
25 ft / 7.6 m RG62AU
Coaxial Cable
(50 ft / 15 m or 100 ft /
30 m Optional)
~4.25”
Overall
3.125”
79.4 mm
2.1” / 53 mm
3/4” NPT
Isolation Coupling
(Supplied)
3/4” NPT
1.125”
28.6 mm
10” / 254 mm
10.94” / 278 mm
Coaxial Cable
30 m Optional)
¾" NPT
3.875”
98.4 mm
~5”
127 mm
Overall
Side View
/
1.75”
44.5 mm
(Supplied)
¾" NPT
greyline.com
OCF 6.1
An ON
I
CON Brand
OPEN CHANNEL FLOW & TANK LEVEL METER
Programmable for any Flume or Weir
The OCF 6.1 includes a built-in 5-button keypad for fa󰏭, easy calibration. Select your choice of engineering units (gallons, liters, cubic meters, etc.) and choose your ume or weir type from the menu. The owmeter also supports entry of ow formulae for non-󰏭andard umes and weirs. ‘Find K&n’ software (included) can be used to calculate non-󰏭andard calibration con󰏭ants for entry into the OCF 6.1 calibration menu.
Built-in control relays can be programmed for ow alarms or a ow proportionate pulse for remote totalizers, samplers, or chlorinators. The isolated 4-20 mA (or 0-5 V) output can be connected to chart recorders, remote displays and
controllers.
Select LEVEL mode for Tank Inventory & Level Control
Set-up using the built-in keypad is fa󰏭 and easy. Scroll through the menu prompts to congure the OCF 6.1 to display level in your choice of measurement units (ft, gallons, liters, inches, meters, mm, percent etc.) for vertical and horizontal round tanks. Connect external devices through the OCF 6.1’s isolated 4-20 mA output or control relays..
Greyline
Precision Flow Measurement
Smart Operating System
Works with any Flume or Weir
Built-in Totalizer
Password Protected
The OCF 6.1 tracks ow continuously through a ume or weir. False echoes from turbulence, splashing rain, or snowfall are automatically rejected. Temperature compensation is automatic for high accuracy. Flow rate and totalizer are shown on the large backlit LCD display.
How to Order
Contact a Greyline sales representative in your area or call one of our sales engineers. Describe your requirements and receive our prompt quotation.
Applications Support
Take advantage of Greyline’s applications experience. Phone toll free 1-888-473-9546 for advice or information on applications, in󰏭allation or service for Greyline products.
No Risk Appraisal
The Greyline OCF 6.1 Level & Flow Monitor mu󰏭 meet your requirements. Discuss your application with a Greyline representative to arrange a 30-day trial.
The Greyline Guarantee
Quality of Materials and Workmanship - Each in󰏭rument manufactured by Greyline is warranted again󰏭 defects in materials and workmanship for a period of one year from date of purchase. Refer to our limited warranty included with each product.
11451 Belcher Road South • Largo, FL 33773 • USA
(P) 315-788-9500 / 888-473-9546 • (F) 315-764-0419 • www.greyline.com
16456 Sixsmith Dr. • Long Sault, Ont. K0C 1P0 • Canada
(P) 613-938-8956 / 855-300-9151 • (F) 613-938-4857 • www.greyline.com Rev 0.1