Greyline Instruments MantaRay Operating Manual

www.greyline.com
USER'S GUIDE
Installation & Operation
Instructions
Portable Area-Velocity Flow
Meter
Model MantaRay
Manual Series A.1.1
Note: This page has been left blank intentionally.
MantaRay Portable Area-Velocity Flow Meter
INDEX
CONNECTIONS ................................................................................................ 4
KEYPAD SYSTEM ............................................................................................ 5
BATTERY .......................................................................................................... 5
CALIBRATION MENU ..................................................................................... 6
ICONS ................................................................................................................. 6
MESSAGE ICON ............................................................................................... 8
STATUS ............................................................................................................. 8
PASSWORD ....................................................................................................... 9
UNITS/MODE .................................................................................................. 10
CALIBRATION................................................................................................ 11
RELAY PARAMETERS .................................................................................. 14
DATA LOGGING ............................................................................................ 15
SPECIAL FUNCTIONS ................................................................................... 17
INSTALLATION - SENSOR LOCATION ...................................................... 19
APPLICATIONS HOTLINE ............................................................................ 22
PRODUCT RETURN PROCEDURE ............................................................... 23
AREA-VELOCITY FLOW DATA SHEET ..................................................... 24
SPECIFICATIONS ........................................................................................... 28
IMPORTANT NOTE: This instrument is manufactured and calibrated to meet product specifications. Please read this manual carefully before installation and operation. Any unauthorized repairs or modifications may result in a suspension of the warranty.
Available in Adobe Acrobat pdf format
Page 3
CONNECTIONS
MantaRay Portable Area-Velocity Flow Meter
Charger and IO Sensor USB
Thumbdrive
not
supplied
Charger
or optional
Break-out Box
pg. 27
QZ02LPlug Connector
see pg. 28
Page 4
MantaRay Portable Area-Velocity Flow Meter
KEYPAD SYSTEM
The MantaRay uses a menu system. Arrows show the four directions to leave a menu box. Pressing a corresponding keypad arrow will move to the next item in the direction shown. Move the cursor (underline) under numerals and increase or decrease numerals with the and keys.
To store calibration values permanently (even through power interruptions), press .
Area Velocity Flow Meter
MANTA RAY
SLEEP
BACK LIGHT
ON
OFF
BATTERY
- A built-in rechargable NiMH battery supplies power for 48 hours continuous operation when fully charged.
- Display brightness is adjustable to conserve power.
- The MantaRay will switch off automatically when the battery is fully discharged.
- Full charge requires approximately 6 to 9 hours charging.
- Sleep mode extends battery life for long term data logging (30 days for 5 minute logging).
CHARGING BATTERY
A 16V AC-DC power module is supplied for battery charging and continuous use. Full charge requires 6-9 hours when fully drained. Solid battery icon and/or full charge adapter icon indicates when battery is fully charged.
Page 5
CALIBRATION MENU
MantaRay Portable Area-Velocity Flow Meter
Mode Flow}
Linear in
Volume USG
Time min
Temperature C
--Units/Mode--------
--Calibration-------
20mA Flo 10.000ft /s³
}
³
4mA Flo 0.000ft /s
Min Level 0.000in
Lvl Offset 0.000in
Min Vel 0.000ft/s
Damping 10%
Max Height 0.75ft
-- -----Channel Setup-
}Type Round
/minOn 1000 USG
/minOff 0.000 USG
Function Flow
Relay 1}
--Relay Parameters--
Calibration
Channel Setup
Relay Parameters
Data Logging
Special Functions
Simulation
Units / Mode}
--Menu Selections----
Password 0000
--Password----------
USG/m
Configuration
Mode Flow
Set Date May 27/2013
Set Time 11:27:40
Interval 10sec
Log Logging
Log Site ID 0}
--Data Logging-------
--Special Functions-
Language English}
Analog Out 4-20mA
Backlight High
2Relays
24Logger 1. T
Level 0.00in
Velocity 10ft/s
Reset Totalizer NO
Negative Totals NO
Flo Direction Off
Cal Constant 1.000
Restore Defaults NO
New Password 0000
Flow 1982.88USG/m
4-20mA Flow 20.00
}Test Actual
Relays 1 2
--Simulation--------
Doppler 1.15
Analog Out 1
Sonar 1.11
Utility 1.25.02
--Configuration-----
}
ud 2Log se %
Data Log Logging
Battery 100%
Charger Off
Sensor Good
--Message-----------
Temperature 24C
0.000ft/sAverage
0.000ft/sMaximum
Date Feb. 12/20} 10
--24 hr log--Velocity
50138 USGTotal
34.82 USG/mAverage
Date Feb. 12/20} 10
--24 hr log------Flow
0.000ftAverage
0.000ftMaximum
Date Feb. 12/20} 10
--24 hr log-----Level
0.000
Tot 20130.8 USG
Relays 1 2
9:15:00Min Time
11:08:00Max Time
0.000ft/sMinimum
9:15:00Min Time
11:08:00Max Time
52.20 USG/mMaximum
0.000 USG/mMinimum
0.000ftMinimum
9:15:00Min Time
11:08:00Max Time
Velocity 0.00ft/s
Flow 0.000 ft/s
Tot 0.000USG
Signal Cutoff 5%
Signal Strength 0%
EC 100%
--Status------------
}Level 0.00 ft
Relays 1 2
Page 6
ICONS
MantaRay Portable Area-Velocity Flow Meter
1. 2.
1.
1.
1.
2. 3.
2.
2.
3.
4.
Message waiting. Press .Ç
Data logging .off
Data logging .on
USB file download.
File download completed.
Download Error.
Echo OK.
No Echo.
Battery
0%
Battery
25%
Battery
50%
Battery
75%
Battery
100%
Battery status / charging icon.
External Battery Source.
Full charge powered by 16V adapter.
Sleep mode icon indicates that Manta ay is running in sleep mode.R The icon appears only during the wake cycle when the display is fully lit.
Page 7
MantaRay Portable Area-Velocity Flow Meter
USG/m
0.000
Tot 20130.8 USG Relays 1 2
--Message----------­Data Log Logging Battery 100% Charger Off
ud 2Log se % Sensor Good Temperature 24C
--Status-----------­}Level 0.00 ft
Velocity 0.00ft/s Flow 0.000 ft/s Tot 0.000USG Signal Cutoff 5% Signal Strength 0% EC 100% Relays 1 2
MAIN DISP LAY
The main display shows the units selected from the
Units/Mode menu,
Flow or Velocity rate being measured, TOTALIZER and RELAY states. The MantaRay will start-up with this display.
MESSAGE ICON
Press from the main display to view temperature measurement, status of the data logger battery and error/warning messages provided by the instrument. The Message Icon will appear on the main display if error messages are being generated by the instrument. Press to return to the main display.
STATUS
Press from the MAIN display to view instrument status.
Velocity Will be displayed in ft/sec or m/sec.
Level Is displayed in the selected units.
Displays the current totalizer reading.
Tot
Signal Cutoff Adjust the setting in percent to suppress flow readings
at zero flow when fluid swirling or pipe vibration may cause the instrument to continue reading. Example:
Signal Cutoff at 5% will force the display
and outputs to zero when signal strength drops below 5%.
Signal Strength Displays percentage of signal being received by the
ultrasonic sensor.
EC Displays level measurement Echo Confidence
Relays 1 2 Energized relays will display with reversed font eg:
Page 8
MantaRay Portable Area-Velocity Flow Meter
--24 hr log------Flow Date Feb. 12/2010
}
Total 50138 USG Average 34.82 USG/m Maximum 52.20 USG/m Max Time 11:08:00 Minimum 0.000 USG/m Min Time 9:15:00
--Password----------
Password 0000
24 HR LOG
Press from the MAIN display to view a formatted flow report from instruments with a built-in data logger. Press to pan through
Flow summaries. Press to scroll down one day or repeatedly to scroll to a
Level, Velocity and
specific date. Up to 365 days can be stored. Newest date will overwrite the oldest. Press to return to the main display.
PASSWORD
Password (a number from 0000 to 9999) prevents unauthorized access
The to the
Calibration menu.
From the Main display press to get to password is 0000 and if it has not been changed press to proceed to the
Selections
screen.
Password. Factory default
If a password is required, press to place the cursor under the first digit and or to set the number, then to the second digit, etc. Press or to proceed to
the
Menu Selections screen.
A new password can be stored by going to
Password.
Special Functions/New
Menu
Page 9
Loading...