Portable Open Channel Flow Meter
for Partially-filled Pipes and Open Channels
Portable Area-Velocity
Flow Meter
MantaRay
Display, Transmit, Totalize
Data Logand Flow
s andin Open Channel Pipes
Simple -key Calibration5
4-20mA Output
Two Control Relays
Measures Reverse Flow
Works in Irregular Channel Shapes
Portable
Open Channel Flow Meter
Hydrodynamic Ultrasonic Sensor
Measures Flow in Open Channels
with a Hydrodynamic Ultrasonic Sensor
Designed for flow surveys in open channels, partially full sewer
pipes and surcharged pipes deal for stormwater,. MantaRay is i
sewage irrigation water ., and natural streams
The uses a submerged ultrasonic sensor toMantaRay
continuously measure both Velocity and Level in the channel. The
sensor resists fouling corrosion ., and abrasion
View flowrate and total flow on the large backlit LCDrealtime
display onnect to. C samplers or SCADA and telemetry systems
with the 4-20mA and relay outputs Download flow log files to a.
USB memory stick.

Portable Flow Monitor for
Partially Filled Pipes & Open Channels
Easy to Use
The MantaRay Portable Area-Velocity Flow Meter measures
both and Velocity to calculate flow in an open channel orLevel
pipe. Calibration is simple: enter the pipe diameter or channel
dimensions and the automatically computes andMantaRay
Submerged Sensor
Measures Level And Velocity
The ultrasonic sensor mounts inside the pipe or the bottom of a channelon
with a stainless steel mounting bracket (included) and a single screw into the
bottom of the pipe or channel. No special compounds, tools or hardware are
required. The sensor is completely sealed with orifices or ports.no
Recommended Channel ConditionsPipe or
Careful selection of sensor mounting location results in best performance and
maintenance-free operation. Avoid locations where sediment builds up.
Best possible accuracy will result when t is not andhe water highly turbulent
where velocity is evenly distributed across the channel. The channel should not
have changes immediately upstream of the sensor mountingdrops or direction
location ipe or channel slope should not exceed 3%.and the p
The can measure forward flow velocity up to ft/sec ( m/sec)MantaRay 20 6.2
and reverse flow up to 5 ft/sec (1.5 m/sec). electronics and softwareThe
sample and average to provide readings. Theflow rates continuously stable
submerged velocity/level sensor will measure flow in partially full and
surcharged pipes with pressure up to 10 psi. No special set-up or adjustment is
required. Minimum recommended pipe diameter is 6” (150 mm).
displays flowthe rate and total on its backlit LCD display.
Built-in 2-Million Point Data
Logger
Use MantaRaythe to store time and date-stamped flow values at 10 second to 60
minute intervals. Daily flow reports are automatically created where total, minimum,
maximum and average flow rates are displayed on the LCD display. Transfer log files
to any USB flash drive just by connecting to the logger's USB output. Windows
software is included to display log files in graph and table formats, change
measurement units and generate flow reports. Export data to graphic or text file
formats, or directly to Microsoft Excel.
Sleep Mode for Extended Battery Life
Use the MantaRay’s ‘Sleep Mode’ function to extend battery life while logging flow.
The digital display, outputs and non-essential functions are suspended during sleep
mode. Based on the logger interval, the MantaRay activates the sensor for 12
seconds to obtain flow readings and then resumes low power mode until the next
logger sample interval. To indicate that sleep mode has been activated the digital
display flashes every few seconds while sleeping.
External Battery Input
Connect external 12 or 24VDC batteries to extend the MantaRay’s operating time
indefinitely. Or connect the battery charger supplied with each flowmeter for
continuous operation or for long term 4-20mA output and relay operation. Maximum
power consumption is 2.7 Watts.