Greyline Instruments AVFM-5.0 Application Note

Lagoon Discharge Flow Monitoring
Open Channel Flow Monitoring
a Flume or Weirwithout
The Township of South Glengarry in Eastern Ontario discharges continuously from their 72,000 m3 sewage lagoon. But they ran into flow measurement problems when their magnetic flowmeter was unable to detect seasonal low flow rates.
Township operators liked the Greyline AVFM 5.0 datalogger reporting system where formatted flow reports (total, minimum, maximum and average) could be downloaded automatically to a USB memory stick without carrying a laptop to the site.
The AVFM 5.0 flowmeter electronics were AC­powered and installed in an insulated shed along with a sampler.
Area-Velocity Flow Sensor
The sealed ultrasonic flow sensor was mounted through a tee section at the invert of the horizontal connected to the flowmeter electronics through a watertight cable steel bracket was screwed into the pipe to secure the sensor in place.
After several months of operation, no algae, sediment or weed build-up was observed on the sensor. But the mounting location was fitted with a removable cover to allow periodic cleaning if required.
Visit for product information.