Graco MGO User Manual

MGO™ Series-Flo® Dividers
DESCRIPTION
Trabon MGO Series-Flo® Divider Valves are designed for heavy duty service where, wide temperature variations and high pumping volumes may be expected. Ideal for large circulating oil systems or hydraulic balancing systems which are found in paper and rubber mills.
A typical MGO Series-Flo® Divider Valve Assembly (to the right) consists of an inlet section, end section and three valve sections. This basic system will serve up to six points and, by adding valve sections, it is possible to increase the number of points which can be served up to a maximum of 22.
The MGO valve sections are available in various output per piston cycle (see specifications). Each twin (T) section has 2 outlets, one from each side of the section. Each single (S) section has 1 outlet on either side but one outlet must be plugged to operate properly.
FEATURES/BENEFITS
Delivers metered amount of lubricant.•
High Pressure capability•
Lubricant outlets easily added or removed•
Can be installed on new or existing machines•
Valve bores match hone-fitted to metering pistons•
Viton O-ring seals standard•
OPERATION
Operational sequence of an MGO Series-Flo® divider valve assembly is defined as “progressive”. The term progressive means that each valve section completes its piston stroke, discharging a measured amount of lubricant to the bearing it serves before the following valve section operates. As long as lubricant is supplied under pressure to the inlet section of the divider assembly, valve sections will continue to operate in a progressive manner. Divider assemblies always follow a constant discharge pattern. Whenever lubricant flow ceases, the valving pistons will stop. When flow resumes it will start again at the same point in the discharge cycle.
TORQUE SPECIFICATIONS
Tie Rod Nut 12 ft lbs
Enclosure Plug 15 ft lbs
Outlet Port Plug 6-8 ft lbs
SPECIFICATIONS
Material Zinc Plated Steel and Phosphate Coated Cast Iron
Seals Viton and Buna-N
Max Recommended Operating Pressures
3-7 Section Divider 6,000 psi (414 bar)
8 Section Divider 5,500 psi (380 bar)
9 Section Divider 5,000 psi (345 bar)
10 Section Divider 4,500 psi (311 bar)
11 Section Divider 4,000 psi (276 bar)
Lubricant Oil or Grease
Max Operating Temp 200ºF
Max Cycle Rate
Cycle Pin & Switch 60 cycles/minute
w/out Switch or w/FSM Type Switch
Net Weight (Divider Valve Assembly Approx.)
3 Section Divider 45 lbs (20.46 kg)
4 Section Divider 53 lbs 5 oz (24.18 kg)
5 Section Divider 61 lbs 10 oz (27.95 kg)
6 Section Divider 70 lbs 15 oz (32.17 kg)
7 Section Divider 80 lbs 4 oz (36.40 kg)
8 Section Divider 89 lbs 9 oz (40.62 kg)
9 Section Divider 98 lbs 14 oz (44.84 kg)
10 Section Divider 108 lbs 3 oz (49.07 kg)
11 Section Divider 117 lbs 8 oz (53.40 kg)
+
Section Sizes
150T 0.150 2.048
150S 0.300 4.917
300T 0.300 4.917
300S 0.600 9.834
450T 0.450 7.375
450S 0.900 14.751
600T 0.600 9.834
600S 1.200 19.668
+
This number is stamped on each valve section
*This is the discharge volume per outlet after one complete cycle
200 cycles/minute
Displacement
*(cu.in.) (cm
3
)
Trabon® MGO™ Series-Flo® Dividers
DIMENSIONS Inches/(mm) ORDERING INFORMATION
MGO – XX XXX X XX
NUMBER OF SECTIONS
03 – Three 04 – Four 05 – Five 06 – Six 07 – Seven 08 – Eight 09 – Nine 10 – Ten 11 – Eleven
SECTION CAPACITY
150 – 0.150 cu.in. 300 – 0.300 cu.in. 450 – 0.450 cu.in. 600 – 0.600 cu.in.
TYPE OF SECTION
T – Twin S – Single - Right Hand Outlet L – Single - Left Hand Outlet B – Twin w/Cycle Pin Right Side C – Single w/Cycle Pin Right Side - Right Hand Outlet D – Single w/Cycle Pin Right Side - Left Hand Outlet E – Twin w/Proximity Switch Right Side
Note: Millimeter dimensions appear in parentheses below decimal figure in inches.
Divider
Valve A—DIM. B—DIM. C—DIM.
MGO - 3 10.04 (255.1) 11.00 (279.4) 8.58 (217.8)
MGO - 4 11.78 (299.1) 12.75 (323.8) 10.31 (261.9)
MGO - 5 13.51 (343.2) 14.50 (368.3) 12.05 (305.9)
MGO - 6 15.25 (387.3) 16.25 (412.7) 13.78 (350.4)
MGO - 7 16.98 (431.2) 18.00 (467.2) 15.51 (394.0)
MGO - 8 18.71 (467.8) 19.75 (501.6) 17.25 (438.0)
MGO - 9 20.45 (519.3) 21.50 (546.1) 18.98 (482.1)
MGO - 10 22.18 (563.4) 23.25 (590.5) 20.72 (526.1)
MGO - 11 23.91 (607.3) 25.00 (635.0) 22.4 (570.2)
Divider Assembly Sketch Example MGO-4-450TCR-300S-600T-150C Divider Valve With Indicator
F – Single w/Proximity Switch Right Side - Right Hand Outlet G – Single w/Proximity Switch Right Side - Left Hand Outlet H – Twin w/Cycle Pin Left Side J – Single w/Cycle Pin Left Side - Right Hand Outlet K – Single w/Cycle Pin Left Side - Left Hand Outlet M – Twin w/Proximity Switch Left Side N – Single w/Proximity Switch Left Side - Right Hand Side P – Single w/Proximity Switch Left Side - Left Hand Side
*CROSSPORTING OPTION
CR – Right Hand Side CL – Left Hand Side CB – Both Sides *Omit when not required
NOTES:
Maximum working pressures: See page 1 Specs1.
Capacity sections are specified starting from inlet section2.
When a section is crossported, its outlet is plugged and output is diverted to 3. the next section, farthest from the inlet
Single capacity sections can be crossported on one side only4.
Internal crossporting can be supplied on a capacity sec tion only when supplied 5. on a manifolded assembly. If supplied as a loose unit, internal crossporting may be accomplished by field drilling
Last section, farthest from inlet section, cannot be crossported6.
Indicate crossport option after capacity section if required, omit if not required7.
Preferred mounting is with pistons in horizontal position with inlet at top8.
Use discharge check valves for intermittent operation9.
Contact factory for availability of NPSF ported dividers10.
Divider systems should be limited to first and second stages only. Third 11. staging is not recommended. Refer to Trabon bulletins L20101, L20105 and L20115 for further in formation on system design
L10141
Page 2