Instructions–Parts List
HIGH PRESSURE
Surge Tanks and
Fluid Filters
For fluid surge reduction and for filtering of finishing materials.
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
Fluid Filters
5000 psi (350 bar, 35 MPa) Maximum Working Pressure
307296T
EN
Model 238620, Series A
Exposed Mounting
Model 214724, Series E
Cover Mounting
Model 289310, Series A
Cover Mounting
Fluid Filter
7252 psi (500 bar, 50 MPa) Maximum Working Pressure
Model 237069, Series A
Exposed Mounting
Surge Tanks (with filter)
5000 psi (350 bar, 35 MPa) Maximum Working Pressure
Model 214624, Series C
Exposed Mounting
Model 238623, Series A
Exposed Mounting
Model 214726, Series E
Cover Mounting
Fluid Filter,
Exposed
Mounting
Fluid Filter,
Cover
Mounting
1008 1009
Mastic Surge Tanks (without filter)
5000 psi (350 bar, 35 MPa) Maximum Working Pressure
Model 214623, Series A
Exposed Mounting; for use with high viscosity fluids
Model 214725, Series C
Covered Mounting; for use with low to medium viscosity fluids
Surge Tank,
Exposed
Mounting
1008
Surge Tank,
Cover
Mounting
1005
Table of Contents
Symbols
Warnings 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Surge Tank Conversion Kits 4. . . . . . . . . . . . . . . . . . . . .
Operation 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Service 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Parts 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessories 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mounting Hole Layout 14. . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Warranty 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Graco Information 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WARNING
EQUIPMENT MISUSE HAZARD
Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.
INSTRUCTIONS
D This equipment is for professional use only.
D Read all instruction manuals, tags, and labels before operating the equipment.
Warning Symbol
WARNING
This symbol alerts you to the possibility of serious
injury or death if you do not follow the instructions.
Caution Symbol
CAUTION
This symbol alerts you to the possibility of damage to
or destruction of equipment if you do not follow the
instructions.
D Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor.
D Do not alter or modify this equipment.
D Check equipment daily. Repair or replace worn or damaged parts immediately.
D Do not exceed the maximum working pressure of the lowest rated system component. Refer to the
Technical Data on page 14 for the maximum working pressure of this equipment.
D Use fluids and solvents which are compatible with the equipment wetted parts. Refer to the Tech-
nical Data section of all equipment manuals. Read the fluid and solvent manufacturer’s warnings.
D Comply with all applicable local, state, and national fire, electrical, and safety regulations.
SKIN INJECTION HAZARD
Spray from the gun, leaks or ruptured components can inject fluid into your body and cause extremely
serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also
cause serious injury.
D Fluid injected into the skin might look like just a cut, but it is a serious injury. Get immediate surgi-
cal treatment.
D Do not stop or deflect leaks with your hand, body, glove or rag.
D Follow the Pressure Relief Procedure on page 6 before cleaning, checking or servicing the
equipment.
D Tighten all fluid connections before operating the equipment.
3072962
Installation
Typical Mountings
See Fig. 1 for typical mountings. See page 14 for the
mounting hole layout.
Install the surge tank or filter near the pump outlet.
Position the surge tank so the labels face away from
the pump and so the setscrews, near the top and
bottom of the tank, face toward the pump.
Exposed Mountings
Detail A: With Riser Tube
The top of the surge tank must always be supported.
See Accessories on page 13 for mounting clamps.
Surge tanks must always be mounted upright, as
shown in Fig. 1, not horizontally.
Detail B: No Riser Tube
Detail C: Integral Riser Tube
Fig. 1
05910
Drum Cover Mountings
Detail D: Separate Riser Tube
05912
307296 3
Surge Tank Conversion Kits
Surge Tank Conversion Kits 238634 and
237704
Use Conversion Kits 238634 or 237704 to add a surge
tank to a pump. Kit 238634 includes surge tank
238623 (A) and clamp 238630 (B). Kit 237704 includes
surge tank 214624 (A), clamp 238630 (B), and attaching hardware (C).
1
These parts are included with Conversion Kit 237704 only.
2 Model 238623 Surge Tank shown.
E
B
Connect the surge tank to the fluid outlet (F) of the
displacement pump and install the clamp in the optional outlet (E) at the base of the air motor. See Fig. 2.
Fig. 2
C
1
A
2
F
05927
3072964
Operation
Before operating the equipment, be sure the drain
valve is closed.
Flush the equipment with a compatible solvent to
remove oil used for factory testing and rust prevention.
If you notice excessive surging at the spray gun, shut
off the pump, trigger the gun to relieve fluid pressure,
and open the drain valve (D) at the bottom of the surge
tank. See Fig. 3. After the tank is drained, close the
drain valve and resume operation.
1
Open drain valve to relieve pressure.
1
D
Be sure the drain valve is fully closed when spraying
and fully open when draining or circulating fluid to get
the best results and reduce wear on the valve.
1
D
Fig. 3
0591305911
307296 5