basis for product guarantee or warranty. For applications other than
Type
Recycled material content
Nominal Dimension
(with Sleeve)
Applications
Nominal Voltage
Capacity
Charge Retention
Charging Conditions
Fast Charge
Service Life
Continuous
Overcharge
Weight
Internal Resistance
Max. Charging Voltage
Ambient Temperature
Range
: Rechargeable Nickel Metal
Hydride Cylindrical Cell
Rechargeable Nickel Metal Hydride Battery
Made with Minimum 10% Recycled
materials
= 14.5mm
H = 50.5mm
Recommended discharge current
210 to 6300mA
: 1.2V
Rated: 2100mAh
Typical: 2150mAh
When discharged at 420mA to
1.0V at 20℃
80% of nominal capacity after cell storage at
20℃ for 12months
When discharged at 420mA to 1.0V at 20℃
: 200mA for 16 hrs at 20℃
1050mA to 2100mA (0.5 to 1C)
charge termination control recommended
control parameters:
-∆V
: 0-5mV
DT/dt : 0.8℃/min (0.5 to 0.9C)
0.8 - 1℃/min (1C)
TCO : 45 - 50℃
Timer : 105% nominal input
(for ref. only)
: >500 cycles (IEC standard)
: 210mA maximum current for 1 year.
No conspicuous deformation and/or
leakage
: 27.2g
Average 18mΩ upon fully charged
(Max.28mΩ) at 1000Hz
: 1.5V at 210mA charging
Standard Charge : 0 to 45℃
Fast Charging : 10 to 45℃
Discharge : -20 to 50℃
Storage : -20 to 35℃
Model No.: GP210AAHCE
+0
50.5
-1.3
+0
14.5
-1
5.2(ref.)
Unit:mm
www.gpbatteries.com
Manufacturer reserves the right to alter or amend the design, model and specification without prior notice.
Copyright@GPI International Ltd. – All rights reserved
The information (subject to change without prior notice) contained
in this document is for reference only and should not be used as a
those described here, please consult your nearest GP Sales and
Marketing Office or Distributors.
MRS6394 rev.01
(for Western Europe)