Gossen Lunasix 3, Lunasix 3S notes, repair, CLA

CM
maandag 1 juli 2019
Filenaam: Lunasix reparatie CM
Gossen Lunasix 3 (S) notes, repair, CLA
190 g
180 g
170 g
CM
maandag 1 juli 2019
Filenaam: Lunasix reparatie CM
I've trouble with self rotating ISO scale if I rotate the number scale. !
So did cleaning, removed all the old grease !
I put new grease in the 2 lower discs. I use Molykote 44 grease.!
Now everything runs very smoothly again. Butter-soft as the German say
CM
maandag 1 juli 2019
Filenaam: Lunasix reparatie CM
CM
maandag 1 juli 2019
Filenaam: Lunasix reparatie CM
Oset
Slope
Oset
Low Range
High Range
No ND Filter
Low Range
Battery
Light value
Value Gossen scale
Resistor Value*
Adjust potmeter
EV5
10
25,3 k Ohm
Low range pot Slope
EV0
5
229 k Ohm
Low range pot Oset
Light value
Value Gossen scale
Resistor Value*
Adjust potmeter
EV14
19
6,73 k Ohm
High range pot Slope
EV8
13
95 k Ohm
High range pot Oset
*= custom value only for my 3S
Slope
High Range
ND Filter
0,10 kΩ
1,00 kΩ
10,00 kΩ
100,00 kΩ
1000,00 kΩ
10000,00 kΩ
-4,0
-2,0
0,0
2,0
4,0
6,0
8,0
10,0
12,0
R expected R measured R computed
Schematic PCB PCB side view
Geprobeerd met curve opmeet techniek de meter in te regelen. Niet gelukt. o.a. denk ik omdat metingen met gloeilamp licht zijn gedaan denk ik.
Loading...