Goldmund T-3 Owners manual

4.8 (6)
Goldmund T-3 Owners manual

GOLDMUND T3F

AUTOMATIC RADIAL TONE ARM

USER MANUAL

WARNING !

This high quality tone-arm with unique technical features is invaluable for accurate tracking of monophonic and stereophonic records.

Only careful use can provide all the satisfaction you expect.

All handling must be done according to the following instructions, since it is while setting up that you risk damaging the arm.

However, if the instructions are scrupulously carried out, you will notice that new automatic functions make handling simple and convenient.

IMPORTANT: PLEASE DO NOT CONNECT ANY WIRE OR MOVE ANY

PART BEFORE READING THE FOLLOWING INSTRUCTIONS

I. PRELIMINARIES

The package contains:

-The tone arm itself.

-A box of accessories containing:

. three BTR keys

. four screws for mounting the tone arm on the turntable

. spare screws for headshell

. damping fluid

. a syringe to fill the damping well with damping fluid.

Unpack the arm without touching the tubular parts. Handle it by its side only.

CAUTION: There are fragile wires at the back of the unit.

CAUTION: Do not remove the arm-tube clamping brackets (with two nylon screws). The arm is ready for installation on your turntable. To ensure precision and safety, it is

necessary to mount the cartridge on the tone arm first.

II. MOUNTING OF THE CARTRIDGE

The headshell is a small rectangular white plate made of ceramic held in place by four small screws in the end of the arm-tube. Loosen the screws with one of the Allen keys supplied.

To mount the cartridge, select the two holes nearest to the arm pivot so as to achieve the widest contact surface. However, if the cartridge is too large (or for any other geometrical reason), you may select the two front holes. The optimum solution is to maintain the shortest distance possible between the arm pivot and the stylus by using the two holes nearest to the arm pivot.

The cartridge screws must be firmly tightened on the headshell to ensure perfect mechanical rigidity.

Mount the headshell on the end of the arm. Tighten the screws alternately and gradually. Should any of the screws resist, replace it with one of the three other screws so as not to damage the thread. The four screws must be firmly and thoroughly tightened so as to ensure perfect cohesion between the various mechanical parts of the tone arm.

Now plug the four gold-plated connectors in the cartridge according to the international code:

Red: right channel, hot

Green: right channel, ground

White: left channel, hot

Blue: left channel, ground

Note: The high-quality Goldmund connectors mounted on the GOLDMUND T3F tone arm are not adjustable in size. It is possible to obtain other ones for use with some cartridges with smaller pins, e.g. Old Koetsu, Supex.., as well as special ones for the Clearaudio Goldmund cartridge.

III. INSTALLATION OF THE T3F TONEARM ON THE TURNTABLE

Note : The following operations must be carried out with the stylus cover on the cartridge so as to protect your stylus.

The stylus must exactly cross the platter spindle center when you push the arm on the rail towards the enter of the record.

In a well designed arm, the stylus should run in a straight line and the only adjustment necessary is to ensure that this straight line crosses the middle of the record. The rail does

not necessarily have to be positioned parallel to the edge of the turntable. All positions are technically identical. However, for esthetic reasons, you should place the arm parallel to the edge of the turntable.

To mount your T3F on the Reference turntable, see the instructions of the turntable

Use the middle size allen key provided in the accessories box to unscrew the four screws holding the upper cover of the arm. Lift the cover off and remove carefully the foam wedges protecting the carriage during shipment.

Move the arm carriage until stylus of the cartridge is crossing the spindle center of the turntable platter. For this maneuver, slide the carriage along the rail firmly so as to overcome any resistance of the belt on the axis by lifting the arm manually if necessary. Slide the whole tone arm structure assembly backward and forwards until the stylus crosses the platter spindle center.

Tighten the six screws that hold the tone arm support to the turntable. Your arm is now correctly positioned.

IV. CONNECTING AND STARTING THE ELECTRONIC CONTROL BOX

The control box is connected to the tonearm by a gray cable fitted with a 12 point female BINDER plug at each end. This cable is reversible.

Attach one of the connectors of the gray cable to the plug on the back of the control box case.

Check that the POWER of the turntable is OFF.

Connect the main cable from the back of the control box to the wall plug.

Connect the left and right audio channels to the preamplifier. Use CAMAC standard LEMO or FISCHER plugs or the RCA on the side of the tone arm.

Connect the black ground binding post of the Control Box to the ground plug of your preamplifier by an ordinary cable of sufficient gauge.

You must now become familiar with the various controls on the turntable keyboard before tying out your GOLDMUND T3F tone arm.

V. CONTROLS AND OPERATION OF THE GOLDMUND T3F TONEARM

CAUTION : Try out any of the following operations before adjusting the tracking force and vertical tracking force and vertical tracking angle of the tone arm only with extreme care. (See VI and VII.)