Gigabyte GA-8IPP533 Schematics Rev.1.3

5
4
3
2
1
REV:1.3
GA-8IPP533
D D
FSC
TITLE
COVER SHEET BLOCK DIAGRAM CPU 0 CPU 1 LEVEL SHIFT CPU DECOUPLING
C C
MCH DDR DIMM CHANNEL A DDR DIMM CHANNEL B P64H2 PCIX SLOT1 PCIX SLOT2 BRIDGE BOARD CONNECTOR
GIGABIT LAN CONTROLLER
GIGABIT LAN POWERGOD/POWER I2C MULTIPLEXER & 32BIT PCI CONNECTOR
B B
ICH3 SUPER IO
PAGE
1 2,3 5,6 7,8 9 10 11,12,13 14,15,16,17 18,19,20,21 22,23,24,25,26 27 28 29,30 31,32 33,34 35 36,37,38 39
4.5 mil
4 mil
4.5 mil
4 mil
14 mil
4 mil
4.5 mil
4 mil
4.5 mil
8/10/2003
BOARD STACK-UP
PP 2116
FR4
PP 2116
FR4
PP 7628 X 2
FR4
PP 2116
FR4
PP 2116
COMPONENT SIDE
INT 5
INT 1
GND
INT 2
GND
INT 4
INT 6
SOLDER SIDE
0.5OZ
1OZ
1OZ
1OZ
1OZ
1OZINT 3
1OZ
1OZ
1OZ
0.5OZ
ADM1026 HARDWARE MONITOR 40 SERIAL PORT FRONT PANEL & KB/MS ATI RAGE XL VGA CONNECTOR CLOCK GENERATOR USB CONNECTOR
A A
VRM ENABLE AND POWER OK LOGIC POWER CONNECTOR VOLTAGE REGULATORS PCI IDSEL AND ROUTING IPMI GPIO AND I2C ADDRESS
5
4
41 42 43,44 45 46 47 48 49 50,51,52,53,54 55 56
Title
Size Document Number Rev
3
2
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
COVER SHEET
GA-8IPP533
1 58Tuesday, October 21, 2003
1
1.3
5
4
3
2
1
8IPP533 SYSTEM BLOCK DIAGRAM
D D
Ultra 320
SCSI
PCI-X_66MHz
Processor 1
Prestonia/NoconaPrestonia/Nocona
Processor 2
64-Bit PCI-X SLOT3
ZCR
C C
64-Bit PCI-X SLOT 1
PCI-X_66MHz
PCI-X_100MHz
PCI-X_100MHz
BUS A
BUS B
P64H2
#1
HI 2.0_16Bit
400/533
E7501
MCH
DDR Channel A
DDR DIMM
DDR Channel B
DDR DIMM
64-Bit PCI-X SLOT 2
Frame Buffer
Gigabit LAN
82546
B B
PCI-X_100MHz
PCI_33MHz
32 BIT PCI RISER CONNECTOR
ATI
Rage 128XL
VGA Con.
PCI_33MHz
I/O NS PC87366
HI 1.5_8Bit
ICH3-S
LPC
FWHSUPER
IPMI
QLOGIC
ZIRCON_UL
USB Ports
SM BUS
IPMB
A A
PS2 KB / Mouse
5
4
Floppy
3
SERIAL A/B
Title
Size Document Number Rev
2
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
SYSTEM BLOCK DIAGRAM
GA-8IPP533
2 58Tuesday, October 21, 2003
1
1.3
AIC7899
5
4
3
2
1
SYSTEM RESET AND POWER OK BLOCK DIAGRAM
OR
INVERTER
IPMI_RST_IN_N
BMC_PWROK_IN
INVERTER
INVERTER
HIP6301
ICH3_VRMPWRGD
ICH3_PWROK
P64H2_PWROK
ICH3
MCH
P64H2
ICH3_PCIRST_N
PA_PCIRST_N
PB_PCIRST_N
ICH3_CPUPWRGD
CPU_RESET_N
PCIX SLOT1
AIC7899
/AIC7902
82546
PCIX SLOT2
CPU0
CPU1
RJ45-1
RJ45-1
RESET I/O
D D
C C
ZIRCON UL
PWROK
RESET OUT
ITP CONN
ATX
POWER SUPPLY CONN.
LTC1709-7
LTC1735
LTC1735
IPMI_RST_N
RESET SWITCH
INVERTER
ITP_RESET
PS_PWRGD
PGOOD_2D5
INVERTER
PGOOD_1D25
PGOOD_1D2
ICH3_VRMPWRGD
NMI CIRCUIT
ZIRCON UL
NMI_IN
B B
ICH3
GPIO8
NMI
NMI_ SW
INVERTER
CPU0
CPU1
DDR DIMM 1 - 6
ADM1026
VDD_ID
GPIO11
POWER CONN
PWRBTN SW
A A
PWRBTN
SIO
PWRBTN IN
PWRBTN OUT
PWRBTN OUT PWRBTN IN
ZIRCON UL
POWER 0N EN
5
ICH3_PWRBNIB_S_N
EN_PSON_N
4
ICH3
PWRBTN IN
PWRBTN OUT
ICH3_SLP_S5_N
AND
3
INVERTER
PSON
OR
CASE_OPEN
OR
2
PS_ON
Title
Size Document Number Rev
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
SYSTEM RESET AND POWER ON DIAGRAM
GA-8IPP533
3 58Tuesday, October 21, 2003
1
1.3
5
4
3
2
1
DDR
DIMMA2
DIMMA1
D D
DIMMA3
DDR DIMMB1
A8H
DDR
DDR
DDR DIMMB2
AAH
DDR DIMMB3
ACHA0H A4HA2H
ADDR: 60H
ADDR: C2H
CY28329P64H2MCH
ADDR: D2H
SMBUS AND HARDWARE MONITOR BLOCK DIAGRAM
CPU0 EEPROM
ADDR: AEH
(OPTION)
ICH3
ADDR: 44H
SMBUS0
(NOT USE)
3.3VSB
SIO
POWER SUPPLY
(OPTION)
CPU1 EEPROM
ADDR: A8H
(OPTION)
PCIX_SLOT1 PCIX_SLOT2
ICH3 SMBUS
ICH3 SMBUS
3.3VSB3.3V
82546EB
SMBUS2
BMC LAN BUS
C C
BMC SMBUS
3.3VSB
3.3VSB
CONTROL CIRCUIT
PCA9544
ADDR: E2H
SMBUS33VSB
3.3VSB
BLACKPLANE
3VSBSMBUS3
W83791
W83791
W83791 ADDR:5AH ADDR:5CH ADDR:5EH (OPTION) (OPTION) (OPTION)
5VSBSMBUS1
PCA9554A
ADDR: DA/DB
LCD CONNECTOR
ADDR: 70H
74HCT4052
Z2
Z1
Y2_0
Y1_0
Y1_1
I/O 1I/O 0
Y2_1
Y1_2
Y2_2
Y1_3
Y2_3
ID EEPROM FF
ADDR: AEH
LM75
ADDR: 91H
FRONT PANEL
DAC
VCC1_2 VTT_DDR VCC1_5DUAL VCC1_8 VCC2_5G VCC2_5 VCC1_8SB VCC2_5DUAL V_CORE +12V
-12V VCC VBAT_ADM VCC3
ADM1026_INT_N
FAN_SENSE3
5
FAN_SENSE4
6
FAN_SENSE5
9
FAN_SENSE1
3
FAN_SENSE2
4
SMBUS1
5VSB
LM75 LM75
ADDR: 94H/95H
CPU1CPU0 DDR ADDR:
90H/91H
(OPTION) (OPTION)
LM75LM75
ADDR: 92H/93H
SCSI ADDR:
96H/97H
FAN_SENSE3 FAN_SENSE4 FAN_SENSE5 FAN_SENSE1 FAN_SENSE2
ZIRCON_UL
RTC
PCF8563
ADDR: A2/A3
EEPROM 24C128
ADDR:A6H
IPMI
B B
1920
IPMB CONNECTOR
ADDR:28HADDR:24H
CPU0_THERMDA CPU0_THERMDC
CPU1_THERMDA CPU1_THERMDC
CPU0_HOT_N CPU1_HOT_N
PS_ON_N
ADM1026
ADDR: 5CH
PWM
FAN_PWM1 FAN_PWM2
ADM1026 DAC ADM1026 PWM BMC PWM1 BMC PWM2
A A
PS FAN1
PS FAN2
Housing FAN
CPU FAN1
CPU FAN2
CPU FAN3
CPU FAN4
CPU FAN5
CPU FAN6
CPU FAN7
CPU FAN8
BRIDGE BOARD
Title
Size Document Number Rev
5
4
3
2
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
SMBUS BLOCK DIAGRAM
GA-8IPP533
4 58Tuesday, October 21, 2003
1
1.3
5
PROCESSOR1 FC-mPGA604
(END
HD[0..63][7,11]
HD63
AB6 C8
HD62
Y9
HD61
AA8
HD60
D D
C C
B B
THE PIN C5 IS VCCVIDLB FOR NOCONA CPU.
R7 1K/6/X
A A
R13 1K/6
VCC3
R8 1K/6/X
R14 1K/6
R9 1K/6/X
R15 1K/6
TP3 TP5 TP7
TP11 TP13
R10 1K/6/X
R16 1K/6/X
CPU0_VCCVID
R11 1K/6/X
R17 1K/6/X
HD59 HD58 HD57 HD56 HD55 HD54 HD53 HD52 HD51 HD50 HD49 HD48 HD47 HD46 HD45 HD44 HD43 HD42 HD41 HD40 HD39 HD38 HD37 HD36 HD35 HD34 HD33 HD32 HD31 HD30 HD29 HD28 HD27 HD26 HD25 HD24 HD23 HD22 HD21 HD20 HD19 HD18 HD17 HD16 HD15 HD14 HD13 HD12 HD11 HD10 HD9 HD8 HD7 HD6 HD5 HD4 HD3 HD2 HD1 HD0
CPU0-SM_EP_A2
R12 1K/6/X
CPU0-SM_EP_A1 CPU0-SM_EP_A0 CPU0-SM_TS_A1 CPU0-SM_TS_A0 CPU_SMBUS_WP
1K/6/X
R18
5
AC5 AC6 AE7 AD7
AC8 AB10 AA10 AA11 AB13 AB12 AC14 AA14 AA13
AC9
AD8 AD10
AE9 AC11 AE10 AC12 AD11 AD14 AD13 AB15 AD18 AE13 AC17 AA16 AB16 AB17 AD19 AD21 AE20 AE22 AC21 AC20 AA18 AC23 AE23 AD24 AC24 AE25 AD25 AC26 AE26 AA19 AB19 AB22 AB20 AA21 AA22 AB23 AB25 AB26 AA24
Y23 AD27 AA25
Y24 AA27
Y26
AC1
W3
D25
A26
A16
C5
processor)
U1A
D63 A35 D62 D61 D60
Socket 604
D59 D58 D57 D56 D55 D54 D53 D52 D51 D50 D49 D48 D47 D46 D45 D44 D43 D42 D41 D40 D39 D38 D37 D36 D35 D34 D33 D32 D31 D30 D29 D28 D27 D26 D25 D24 D23 D22 D21 D20 D19 D18 D17 D16 D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
RSVD1 RSVD2 RSVD3 RSVD4 RSVD5 RSVD6
SOCKET-604
V_CORE
Part 1
L1
4.7U/8
L2
4.7U/8
BREQ4# BREQ3# BREQ2# BREQ1# BREQ0#
RSVD10
21
C1 10U/12
C8 10U/12
21
4
HA35 HA34
C9
A34
HA33
A7
A33
HA32
A6
A32
HA31
B7
A31
HA30
C11
A30
HA29
D12
A29
HA28
E13
A28
HA27
B8
A27
HA26
A9
A26
HA25
D13
A25
HA24
E14
A24
HA23
C12
A23
HA22
B11
A22
HA21
B10
A21
HA20
A10
A20
HA19
F15
A19
HA18
D15
A18
HA17
D16
A17
HA16
C14
A16
HA15
C15
A15
HA14
A12
A14
HA13
B13
A13
HA12
B14
A12
HA11
B16
A11
HA10
A13
A10
HA9
D17
A9
HA8
C17
A8
HA7
A19
A7
HA6
C18
A6
HA5
B18
A5
HA4
A20
A4
HA3
A22
A3
-HREQ4
B22
-HREQ3
C20
-HREQ2
C21
-HREQ1
B21
-HREQ0
B19
DBI[0..3]
DBI3
AB9
DBI3# DBI2# DBI1# DBI0#
DP3# DP2# DP1# DP0#
AP1# AP0#
RSVD7 RSVD8 RSVD9
DBI2
AE12
DBI1
AD22
DBI0
AC27
DP3
AE17
DP2
AC15
DP1
AE19
DP0
AC18
D9 E10
P0_FORCEPR_N
A15
CPU0_VCCVID
A4 A1 AE16
THE PIN A15 IS FORCEPR# FOR NOCONA CPU. T HE PIN A4 IS VCCVID FOR NOCONA CPU.
V_CORE
CPU0_VCCA
C1586 22U/12
CPU0_VSSA
C1587 22U/12
CPU0_VCCIOPLL
4
AP1_N AP0_N
TP19 TP4
CLOSE TO CPU0
R1734
49.9/6/1
P0_FORCEPR_N
DP[0..3]
HA[3..35] [7,11]
-HREQ[0..4] [7,11]
DBI[0..3] [7,11]
R32 51/6/1
R38
86.6/6/1
DP[0..3] [7,11]
AP1_N [7,11] AP0_N [7,11]
P0_FORCEPR_N [9]
R37 R38
C5 1U/6
BREQ2_3_N[7]
CPU1_BREQ0_N[9]
CPU0_BREQ0_N[9]
RS[0..2][7,11]
CPU0_BSEL1[48] CPU0_BSEL0[46,48]
CPU0_VID[0..4][48,49]
NOCONA
86.6 ohn 1%
C6 220P/6
BPRI_N[7,11]
I2C_BUS0_CLK[7,35,39]
I2C_BUS0_DAT[7,35,39]
CPU_SMBUS_WP[7]
CPU_SMBALERT_N[7,35,37]
VCC3
PRESTONIA
100 ohn 1%86.6 ohn 1% 100 ohn 1%
C7 220P/6
3
BPRI_N BREQ2_3_N
CPU1_BREQ0_N CPU0_BREQ0_N
RS[0..2]
ICH3_A20M_N[6,7,36] ICH3_IGNNE_N[6,7,36]
CPU_LINT1_NMI[6,7]
ICH3_LINT0_INTR[6,7,36]
I CH3_CPUPWRGD[7,36]
ICH3_CPUSLP_N[6,7,36]
R1384 1K/6
3
R1
49.9/6/1
DEFER_N[7,11] CPURST_N[6,7,11]
RSP_N[7,11]
HTRDY_N[7,11]
ICH3_INIT_N[6,7,36,37]
FERR_N[7,36]
CPU0_SMI_N[9]
STPCLK_N[6,7]
CPU0_BCLK0[46] CPU0_BCLK1[46]
ITP_TCK_P[6,7] ITP_TDI_P0[6]
ITP_TMS_P[6,7] ITP_TRST_N[6,7] ITP_TDO_P0[6]
I2C_BUS0_CLK I2C_BUS0_DAT CPU_SMBUS_WP CPU_SMBALERT_N
3VSB
R1385 1K/6
CPU0_VID[0..4]
CPU0_604_PRT#[37]
V_COREV_CORE
R31 51/6/1
R37
86.6/6/1
V_CORE
R1306
49.9/6/1
DEFER_N CPURST_N
RS2 RS1 RS0
RSP_N HTRDY_N
ICH3_A20M_N ICH3_IGNNE_N ICH3_INIT_N FERR_N CPU_LINT1_NMI ICH3_LINT0_INTR
I CH3_CPUPWRGD
CPU0_SMI_N
ICH3_CPUSLP_N
STPCLK_N CPU0_BCLK0
CPU0_BCLK1 ITP_TCK_P
ITP_TDI_P0 ITP_TMS_P ITP_TRST_N ITP_TDO_P0
CPU0-SM_EP_A2 CPU0-SM_EP_A1 CPU0-SM_EP_A0
CPU0-SM_TS_A1 CPU0-SM_TS_A0
R1772 47/6
CPU0_VCCA CPU0_VCCIOPLL
TP1
CPU0_VID4 CPU0_VID3 CPU0_VID2 CPU0_VID1 CPU0_VID0
CPU0_VSSA
C2 1U/6
V_CORE
R6
49.9/6/1 U1B
D23
BPRI#
D10
BR3#
E11
BR2#
F12
BR1#
D20
BR0#
C23
DEFER#
Y8
RESET#
F21
RS2#
D22
RS1#
E21
RS0#
C6
RSP#
E19
TRDY#
F27
A20M#
C26
IGNNE
D6
INIT
E27
FERR#
G23
LINT1
B24
LINT0
AB7
PWRGOOD
C27
SMI#
AE6
SLP#
D4
STPCLK#
Y4
BCLK0
W5
BCLK1
E24
TCK
C24
TDI
A25
TMS
F24
TRST#
E25
TDO
AB28
SM_EP_A2
AB29
SM_EP_A1
AA29
SM_EP_A0
Y29
SM_TS_A1
AA28
SM_TS_A0
AC28
SM_CLK
AC29
SM_DAT
AD29
SM_WP
AD28
SM_ALERT#
AE28
SM_VCC0
AE29
SM_VCC1
AB4
VCCA
AD4
VCCIOPLL
B27
VCC_SENSE
AB3
BSEL1
AA3
BSEL0
B3
VID4
C3
VID3
D3
VID2
E3
VID1
F3
VID0
AA5
VSSA
VCC3
C3 220P/6
R1386 10K/6
D26
AE15
AE4
CPU0_GTL_VREF1CPU0_GTL_VREF2
C4 220P/6
VSS_SENSE RSVD11
SMB_PRT
SOCKET-604
TP2 TP6
2
Socket 604
Part 2
3VSB
R1354
4.7K/6
2
IERR#
ADS#
BINIT#
BNR#
BPM5# BPM4# BPM3# BPM2# BPM1# BPM0#
DBSY# DRDY#
HIT#
HITM#
LOCK#
MCERR#
ADSTB1# ADSTB0#
DSTBP3# DSTBP2# DSTBP1# DSTBP0#
DSTBN3# DSTBN2# DSTBN1# DSTBN0#
THERMTRIP#
PROCHOT#
COMP1 COMP0
GTLREF3 GTLREF2 GTLREF1 GTLREF0
ODTEN
SKTOCC#
TESTHI6 TESTHI5 TESTHI4 TESTHI3 TESTHI2 TESTHI1 TESTHI0
RSVD15 RSVD16 RSVD17 RSVD18 RSVD19 RSVD20
R26
4.7K/6
CPU_SMBALERT_N
V_CORE
R1305 470/6
CPU0_IERR_N
E5
ADS_N
D19
BINIT_N
F11
BNR_N
F20
CPU_BPM5_N
E4
CPU_BPM4_N
E8
CPU_BPM3_N
F5
CPU_BPM2_N
E7
CPU_BPM1_N
F8
CPU_BPM0_N
F6
DBSY_N
F18
HDRDY_N
E18
HIT_N
E22
HITM_N
A23
HLOCK_N
A17
BERR_N
D7
ADSTB1
F14
ADSTB0
F17
DSTBP3
Y11
DSTBP2
Y14
DSTBP1
Y17
DSTBP0
Y20
DSTBN3
Y12
DSTBN2
Y15
DSTBN1
Y18
DSTBN0
Y21
CPU0_THRMTRIP_N
F26
PROC0_HOT_N
B25
CPU0_COMP1
E16
CPU0_COMP0
AD16
CPU0_GTL_VREF2
F9 F23
CPU0_GTL_VREF1
W9 W23
CPU0_ODTEN
B5
CPU0_SKTOCC_N
A3
CPU0_TESTHI6
AE5
CPU0_TESTHI5
AD5
CPU0_TESTHI4
AA7
CPU0_TESTHI3
Y6
CPU0_TESTHI2
W8
CPU0_TESTHI1
W7
CPU0_TESTHI0
W6
Y28 Y27 Y3 AD1 B1 AE30
R27
4.7K/6
I2C_BUS0_CLK I2C_BUS0_DAT
Title
Size Document Number Rev
Date: Sheet of
V_CORE
CPU0_IERR_N [6,9] ADS_N [7,11] BINIT_N [7,11] BNR_N [7,11]
CPU_BPM5_N [6,7] CPU_BPM4_N [6,7] CPU_BPM3_N [6,7] CPU_BPM2_N [6,7] CPU_BPM1_N [6,7] CPU_BPM0_N [6,7]
ADSTB[0..1]
DSTBP[0..3]
DSTBN[0..3]
R19 49.9/6/1 R20 49.9/6/1
R21 51/6
R89 4.7K/6
CPU0_THERM_DC1 [40]
CPU0_THERM_DA1 [40]
TP18 TP20 TP21 TP372
FERR_N PROC0_HOT_N I CH3_CPUPWRGD CPURST_N
GIGA-BYTE TECHNOLOGY CO., LTD.
CPU1 SIGNAL
1
R35 150/6/X R36 150/6 R39 150/6/X
DBSY_N [7,11] HDRDY_N [7,11] HIT_N [7,11] HITM_N [7,11] HLOCK_N [7,11] BERR_N [7,11]
ADSTB[0..1] [7,11]
DSTBP[0..3] [7,11]
DSTBN[0..3] [7,11]
CPU0_THRMTRIP_N [9] PROC0_HOT_N [9]
CPU0_SKTOCC_N [48,51]
R22 49.9/6/1 R23 49.9/6/1 R24 49.9/6/1 R25 49.9/6/1 R28 49.9/6/1 R29 49.9/6/1 R30 49.9/6/1
V_CORE
R2
R3
200/6
56/6
GA-8IPP533
1
ITP_TDO_P0 ITP_TDI_P0 ITP_TRST_N
V_CORE
3VSB
R4 200/6
5 58Tuesday, October 21, 2003
V_CORE
R5 51/6
1.3
5
4
3
2
V_CORE
1
V_CORE
U1C
AD30
VCC1
AC31
VCC2
AC3
VCC3
AB30
D D
C C
B B
A A
AB2
AA31
AA1
M3
M1 L30 L28 L26 L24
K31 K29 K27 K25 K23
J30 J28 J26 J24
H31 H29 H27 H25 H23
G30 G28 G26 G24
G8
G6
G4
G2 F31 F29 F22 F16 F10
E30 E28 E26 E20 E12
D31 D29 D24 D18 D14
C30 C28 C22 C16 C10
B31 B29 B26 B20 B12
A30 A28 A24 A18 A14
L8 L6 L4 L2
K9 K7 K5 K3 K1
J8 J6 J4 J2
H9 H7 H5 H3 H1
F4 F1
E6 E2
D8 D1
C4 C2
B6 B4
A8 A2
VCC4 VCC5 VCC6 VCC7 VCC8 VCC9 VCC10 VCC11 VCC12 VCC13 VCC14 VCC15 VCC16 VCC17 VCC18 VCC19 VCC20 VCC21 VCC22 VCC23 VCC24 VCC25 VCC26 VCC27 VCC28 VCC29 VCC30 VCC31 VCC32 VCC33 VCC34 VCC35 VCC36 VCC37 VCC38 VCC39 VCC40 VCC41 VCC42 VCC43 VCC44 VCC45 VCC46 VCC47 VCC48 VCC49 VCC50 VCC51 VCC52 VCC53 VCC54 VCC55 VCC56 VCC57 VCC58 VCC59 VCC60 VCC61 VCC62 VCC63 VCC64 VCC65 VCC66 VCC67 VCC68 VCC69 VCC70 VCC71 VCC72 VCC73 VCC74 VCC75 VCC76 VCC77 VCC78 VCC79 VCC80 VCC81 VCC82 VCC83 VCC84 VCC85 VCC86 VCC87 VCC88 VCC89 VCC90 VCC91 VCC92 VCC93 VCC94 VCC95
SOCKET-604
Socket 604
Part 3
5
VCC96 VCC97 VCC98
VCC99 VCC100 VCC101 VCC102 VCC103 VCC104 VCC105 VCC106 VCC107 VCC108 VCC109 VCC110 VCC111 VCC112 VCC113 VCC114 VCC115 VCC116 VCC117 VCC118 VCC119 VCC120 VCC121 VCC122 VCC123 VCC124 VCC125 VCC126 VCC127 VCC128 VCC129 VCC130 VCC131 VCC132 VCC133 VCC134 VCC135 VCC136 VCC137 VCC138 VCC139 VCC140 VCC141 VCC142 VCC143 VCC144 VCC145 VCC146 VCC147 VCC148 VCC149 VCC150 VCC151 VCC152 VCC153 VCC154 VCC155 VCC156 VCC157 VCC158 VCC159 VCC160 VCC161 VCC162 VCC163 VCC164 VCC165 VCC166 VCC167 VCC168 VCC169 VCC170 VCC171 VCC172 VCC173 VCC174 VCC175 VCC176 VCC177 VCC178 VCC179 VCC180 VCC181 VCC182 VCC183 VCC184 VCC185 VCC186 VCC187 VCC188 VCC189 VCC190
AE3 Y2 AD2 AE24 AE18 AE14 AE8 AD26 AD20 AD12 AD6 AC22 AC16 AC10 AC4 AB24 AB18 AB14 AB8 AA26 AA20 AA12 AA6 AA4 Y30 Y22 Y16 Y10 W31 W29 W27 W25 W1 V30 V28 V26 V24 V8 V6 V4 V2 U31 U29 U27 U25 U23 U9 U7 U5 U3 U1 T30 T28 T26 T24 T8 T6 T4 T2 R31 R29 R27 R25 R23 R9 R7 R5 R3 R1 P30 P28 P26 P24 P8 P6 P4 P2 N31 N29 N27 N25 N23 N9 N7 N5 N3 N1 M31 M29 M27 M25 M23 M9 M7 M5
V_CORE
R1684
0/6/X
NC FOR NOCONA
49.9 ohm FOR NOCONA
R1685
49.9/6/1
R42
U1D
M30
VSS1
M28
VSS2
M26
VSS3
M24
VSS4
M8 M6 M4
M2 L31 L29 L27 L25 L23
L9 L7 L5 L3
L1 K30 K28 K26 K24
K8
K6
K4
K2
J31 J29 J27 J25 J23
J9 J7 J5 J3
J1 H30 H28 H26 H24
H8 H6 H4
H2 G31 G29 G27 G25
G9 G7 G5 G3
G1 F30 F28 F25 F19 F13
F7
F2 E31 E29 E23 E17 E15
E9
E1 D30 D28 D27 D21 D11
D5
D2 C31 C29 C25 C19 C13
C7
C1 B30 B28 B23 B17 B15
B9
B2 A31 A29 A27 A21 A11
A5
4
VSS5 VSS6 VSS7 VSS8 VSS9 VSS10 VSS11 VSS12 VSS13 VSS14 VSS15 VSS16 VSS17 VSS18 VSS19 VSS20 VSS21 VSS22 VSS23 VSS24 VSS25 VSS26 VSS27 VSS28 VSS29 VSS30 VSS31 VSS32 VSS33 VSS34 VSS35 VSS36 VSS37 VSS38 VSS39 VSS40 VSS41 VSS42 VSS43 VSS44 VSS45 VSS46 VSS47 VSS48 VSS49 VSS50 VSS51 VSS52 VSS53 VSS54 VSS55 VSS56 VSS57 VSS58 VSS59 VSS60 VSS61 VSS62 VSS63 VSS64 VSS65 VSS66 VSS67 VSS68 VSS69 VSS70 VSS71 VSS72 VSS73 VSS74 VSS75 VSS76 VSS77 VSS78 VSS79 VSS80 VSS81 VSS82 VSS83 VSS84 VSS85 VSS86 VSS87 VSS88 VSS89 VSS90 VSS91 VSS92 VSS93 VSS94
SOCKET-604
Socket 604
Part 4
G7 : BOOT_SELECT
C1 : TESTLOW
VSS95 VSS96 VSS97 VSS98
VSS99 VSS100 VSS101 VSS102 VSS103 VSS104 VSS105 VSS106 VSS107 VSS108 VSS109 VSS110 VSS111 VSS112 VSS113 VSS114 VSS115 VSS116 VSS117 VSS118 VSS119 VSS120 VSS121 VSS122 VSS123 VSS124 VSS125 VSS126 VSS127 VSS128 VSS129 VSS130 VSS131 VSS132 VSS133 VSS134 VSS135 VSS136 VSS137 VSS138 VSS139 VSS140 VSS141 VSS142 VSS143 VSS144 VSS145 VSS146 VSS147 VSS148 VSS149 VSS150 VSS151 VSS152 VSS153 VSS154 VSS155 VSS156 VSS157 VSS158 VSS159 VSS160 VSS161 VSS162 VSS163 VSS164 VSS165 VSS166 VSS167 VSS168 VSS169 VSS170 VSS171 VSS172 VSS173 VSS174 VSS175 VSS176 VSS177 VSS178 VSS179 VSS180 VSS181 VSS182 VSS183 VSS184 VSS185 VSS186 VSS187 VSS188 VSS189
AE2 AD3 AE27 AE21 AE11 AD31 AD23 AD17 AD15 AD9 AC30 AC25 AC19 AC13 AC7 AC2 AB31 AB27 AB21 AB11 AB5 AB1 AA30 AA23 AA17 AA15 AA9 AA2 Y31 Y25 Y19 Y13 Y7 Y5 Y1 W30 W28 W26 W24 W4 W2 V31 V29 V27 V25 V23 V9 V7 V5 V3 V1 U30 U28 U26 U24 U8 U6 U4 U2 T31 T29 T27 T25 T23 T9 T7 T5 T3 T1 R30 R28 R26 R24 R8 R6 R4 R2 P31 P29 P27 P25 P23 P9 P7 P5 P3 P1 N30 N28 N26 N24 N8 N6 N4 N2
3
V_CORE
R1682 0/6/X
R1683 0/6
AC30 : SLEW_CTRL
FOR NOCONA
ICH3_A20M_N[5,7,36] ICH3_IGNNE_N[5,7,36] ICH3_LINT0_INTR[5,7,36] CPU_LINT1_NMI[5,7] ICH3_CPUSLP_N[5,7,36]
CPU0_IERR_N[5,9]
ICH3_LINT1_NMI[36]
ICH3_SMI_N[9,36] STPCLK_N[5,7]
ICH3_STPCLK_N[36] ICH3_INIT_N[5,7,36,37]
RP1
7 5 3 1
8P4R-51
2
1 3 5 7
9 11 13 15 17 19 21 23 25 26
H2X13/PTH2.0/X
8 6 4 2
CPU_BPM0_N[5,7] CPU_BPM1_N[5,7] CPU_BPM2_N[5,7] CPU_BPM3_N[5,7]
CPU_BPM5_N[5,7] CPURST_N[5,7,11] ITP_TCK_P [5,7] ITP_TCK_P[5,7] ITP_BCLK0[46] ITP_BCLK1[46]
CPU_BPM0_N CPU_BPM1_N CPU_BPM2_N CPU_BPM3_N CPU_BPM4_N CPU_BPM5_N
CPU_BPM5_N CPU_BPM4_N CPU_BPM3_N CPU_BPM2_N
CPU_BPM1_N CPU_BPM0_N
ITP_TDO_P1 ITP_TMS_P
R1307 51/6 R1308 51/6
R87 75/6 R33 51/6
R41 200/6
R1286 0/6
ICH3_SMI_N
STPCLK_N
ICH3_STPCLK_N
ICH3_INIT_N
Should be close to CPU1
V_CORE
ITP
2 4 6 8 10 12 14 16 18 20 22 24
V_CORE
R43
200/6
200/6
R50 0/6
R51 0/6
R1296
1.5K/6/1
ITP_TMS_P
STPPWR
R1297
27.4/6/1
Title
Size Document Number Rev
Date: Sheet of
R45 200/6
V_CORE
R48 200/6
ITP_TDO_P1 [7]
ITP_TDO_P1
R46 470/6/X
R49 200/6
JP11
1 2 3
H1X3/X
1-2 = P1 Only 2-3 = P1+P2
R44 200/6
R47 200/6
DRB_RESET_N [48] ITP_TDI_P0 [5]
ITP_TMS_P [5,7]CPU_BPM4_N[5,7] ITP_TRST_N [5,7]
ITP_TDO_P0[5] ITP_TDI_P1[7]
GIGA-BYTE TECHNOLOGY CO., LTD.
CPU1 POWER AND GND
GA-8IPP533
6 58Tuesday, October 21, 2003
1
1.3
5
PROCESSOR2 FC-mPGA604
4
3
V_CORE
2
V_CORE
1
("Middle" Processor)
BINIT_N BNR_N BERR_N HITM_N HIT_N
HA[3..35] [5,11]
-HREQ[0..4] [5,11]
DBI[0..3] [5,11]
DP[0..3] [5,11] AP1_N [5,11]
AP0_N [5,11]
P1_FORCEPR_N [9]
V_CORE
CLOSE TO CPU0
R1735
49.9/6/1
P1_FORCEPR_N
V_CORE
L3
4.7U/8
4.7U/8
BPRI_N[5,11]
BREQ2_3_N[5]
CPU0_BREQ0[9]
CPU1_BREQ0[9]
DEFER_N[5,11]
VCC3
CPU1_604_PRT#[37]
CPURST_N[5,6,11]
RSP_N[5,11] HTRDY_N[5,11]
ICH3_A20M_N[5,6,36] ICH3_IGNNE_N[5,6,36] ICH3_INIT_N[5,6,36,37]
CPU_LINT1_NMI[5,6]
ICH3_LINT0_INTR[5,6,36]
I CH3_CPUPWRGD[5,36]
CPU1_SMI_N[9] ICH3_CPUSLP_N[5,6,36]
STPCLK_N[5,6]
CPU1_BCLK0[46] CPU1_BCLK1[46]
ITP_TCK_P[5,6] ITP_TDI_P1[6] ITP_TMS_P[5,6] ITP_TRST_N[5,6] ITP_TDO_P1[6]
I2C_BUS0_CLK I2C_BUS0_DAT CPU_SMBUS_WP CPU_SMBALERT_N
3
FERR_N[5,36]
R1392 1K/6
V_CORE
RS[0..2][5,11]
I2C_BUS0_CLK[5,35,39]
I2C_BUS0_DAT[5,35,39]
CPU_SMBUS_WP[5]
CPU_SMBALERT_N[5,35,37]
CPU1_BSEL1[48] CPU1_BSEL0[48]
CPU1_VID[0..4][48,49]
C9 10U/12
C10 10U/12L4
CPU1_VCCA
C1588 22U/12
CPU1_VSSA
C1589 22U/12
CPU1_VCCIOPLL
21
21
HD[0..63][5,11]
HD63
TP24 TP26 TP28
TP32 TP34
1K/6/X
R62
R67 1K/6/X
1K/6/X
R63
R68 1K/6/X
5
HD62 HD61 HD60 HD59 HD58 HD57 HD56 HD55 HD54 HD53 HD52 HD51 HD50 HD49 HD48 HD47 HD46 HD45 HD44 HD43 HD42 HD41 HD40 HD39 HD38 HD37 HD36 HD35 HD34 HD33 HD32 HD31 HD30 HD29 HD28 HD27 HD26 HD25 HD24 HD23 HD22 HD21 HD20 HD19 HD18 HD17 HD16 HD15 HD14 HD13 HD12 HD11 HD10 HD9 HD8 HD7 HD6 HD5 HD4 HD3 HD2 HD1 HD0
D D
C C
B B
THE PIN C5 IS VCCVIDLB FOR NOCONA CPU.
VCC3
1K/6
1K/6/X
1K/6/X
R60
R61
R59
A A
R65 1K/6/X
R64 1K/6
R66 1K/6/X
U2A
AB6 C8
D63 A35
Y9
D62
AA8
D61
AC5
D60 D59 D58 D57 D56 D55 D54 D53 D52 D51 D50 D49 D48 D47 D46 D45 D44 D43 D42 D41 D40 D39 D38 D37 D36 D35 D34 D33 D32 D31 D30 D29 D28 D27 D26 D25 D24 D23 D22 D21 D20 D19 D18 D17 D16 D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
RSVD1 RSVD2 RSVD3 RSVD4 RSVD5 RSVD6
SOCKET-604
Socket 604
Part 1
V_CORE
R1687
R1688
40.2/6/1
40.2/6/1
C1591
C1590
47P/6
47P/6
40.2/6/1
AC6 AE7 AD7
AC8 AB10 AA10 AA11 AB13 AB12 AC14 AA14 AA13
AC9
AD8 AD10
AE9 AC11 AE10 AC12 AD11 AD14 AD13 AB15 AD18 AE13 AC17 AA16 AB16 AB17 AD19 AD21 AE20 AE22 AC21 AC20 AA18 AC23 AE23 AD24 AC24 AE25 AD25 AC26 AE26 AA19 AB19 AB22 AB20 AA21 AA22 AB23 AB25 AB26 AA24
Y23 AD27 AA25
Y24 AA27
Y26
AC1
W3
D25
C5 A26 A16
CPU1-SM_EP_A2 CPU1-SM_EP_A1 CPU1-SM_EP_A0 CPU1-SM_TS_A1 CPU1-SM_TS_A0
HA35 HA34
C9
A34
HA33
A7
A33
HA32
A6
A32
HA31
B7
A31
HA30
C11
A30
HA29
D12
A29
HA28
E13
A28
HA27
B8
A27
HA26
A9
A26
HA25
D13
A25
HA24
E14
A24
HA23
C12
A23
HA22
B11
A22
HA21
B10
A21
HA20
A10
A20
HA19
F15
A19
HA18
D15
A18
HA17
D16
A17
HA16
C14
A16
HA15
C15
A15
HA14
A12
A14
HA13
B13
A13
HA12
B14
A12
HA11
B16
A11
HA10
A13
A10
HA9
D17
A9
HA8
C17
A8
HA7
A19
A7
HA6
C18
A6
HA5
B18
A5
HA4
A20
A4
HA3
A22
A3
-HREQ4
B22
BREQ4# BREQ3# BREQ2# BREQ1# BREQ0#
DBI3# DBI2# DBI1# DBI0#
RSVD7 RSVD8 RSVD9
RSVD10
-HREQ3
C20
-HREQ2
C21
-HREQ1
B21
-HREQ0
B19
DBI3
AB9
DBI2
AE12
DBI1
AD22
DBI0
AC27
DP3
AE17
DP3# DP2# DP1# DP0#
AP1# AP0#
DP2
AC15
DP1
AE19
DP0
AC18
AP1_N
D9
AP0_N
E10
P1_FORCEPR_N
A15
CPU1_VCCVIDCPU1_VCCVID
A4 A1 AE16
THE PIN A15 IS FORCEPR# FOR NOCONA CPU. THE PIN A4 IS VCCVID FOR NOCONA CPU.
TP40 TP25
FOR NOCONA
R1689
R1690
R1691
40.2/6/1
40.2/6/1
C1592
C1593 47P/6
C1594 47P/6
4
47P/6
CPU0_BREQ0 CPU1_BREQ0
3VSB
R1393 1K/6
R80 51/6/1
R82
86.6/6/1
R52
49.9/6/1
BPRI_N BREQ2_3_N
DEFER_N
CPURST_N
RS2RS[0..2] RS1 RS0
RSP_N HTRDY_N
ICH3_A20M_N ICH3_IGNNE_N ICH3_INIT_N
FERR_N
CPU_LINT1_NMI ICH3_LINT0_INTR
I CH3_CPUPWRGD
CPU1_SMI_N
ICH3_CPUSLP_N
STPCLK_N CPU1_BCLK0
CPU1_BCLK1
ITP_TCK_P ITP_TDI_P1 ITP_TMS_P ITP_TRST_N ITP_TDO_P1
CPU1-SM_EP_A2 CPU1-SM_EP_A1 CPU1-SM_EP_A0
CPU1-SM_TS_A1 CPU1-SM_TS_A0
R1773 47/6
CPU1_VCCA CPU1_VCCIOPLL
TP22
CPU1_VID4 CPU1_VID3 CPU1_VID2 CPU1_VID1 CPU1_VID0
CPU1_VSSA
TP23 TP27
R1394 10K/6
VCC3
C15
C14
220P/6
1U/6
U2B
D23
BPRI#
D10
BR3#
E11
BR2#
F12
BR1#
D20
BR0#
C23
DEFER#
Y8
RESET#
F21
RS2#
D22
RS1#
E21
RS0#
C6
RSP#
E19
TRDY#
F27
A20M#
C26
IGNNE
D6
INIT
E27
FERR#
G23
LINT1
B24
LINT0
AB7
PWRGOOD
C27
SMI#
AE6
SLP#
D4
STPCLK#
Y4
BCLK0
W5
BCLK1
E24
TCK
C24
TDI
A25
TMS
F24
TRST#
E25
TDO
AB28
SM_EP_A2
AB29
SM_EP_A1
AA29
SM_EP_A0
Y29
SM_TS_A1
AA28
SM_TS_A0
AC28
SM_CLK
AC29
SM_DAT
AD29
SM_WP
AD28
SM_ALERT#
AE28
SM_VCC0
AE29
SM_VCC1
AB4
VCCA
AD4
VCCIOPLL
B27
VCC_SENSE
AB3
BSEL1
AA3
BSEL0
B3
VID4
C3
VID3
D3
VID2
E3
VID1
F3
VID0
AA5
VSSA
D26
VSS_SENSE
AE15
RSVD11
AE4
SMB_PRT
SOCKET-604
CPU1_GTL_VREF2
C16 220P/6
Socket 604
Part 2
V_CORE
R79 51/6/1
C11
R81
1U/6
86.6/6/1
2
IERR#
ADS#
BINIT#
BNR#
BPM5# BPM4# BPM3# BPM2# BPM1# BPM0#
DBSY# DRDY#
HIT#
HITM#
LOCK#
MCERR#
ADSTB1# ADSTB0#
DSTBP3# DSTBP2# DSTBP1# DSTBP0#
DSTBN3# DSTBN2# DSTBN1# DSTBN0#
THERMTRIP#
PROCHOT#
COMP1 COMP0
GTLREF3 GTLREF2 GTLREF1 GTLREF0
ODTEN
SKTOCC#
TESTHI6 TESTHI5 TESTHI4 TESTHI3 TESTHI2 TESTHI1 TESTHI0
RSVD15 RSVD16 RSVD17 RSVD18 RSVD19 RSVD20
NOCONA
86.6 ohn 1%
R81 100 ohn 1%
86.6 ohn 1%
R82 100 ohn 1%
CPU1_GTL_VREF1
C12
C13
220P/6
220P/6
R53 470/6
CPU1_IERR_N
E5
ADS_N
D19
BINIT_N
F11
BNR_N
F20
CPU_BPM5_N
E4
CPU_BPM4_N
E8
CPU_BPM3_N
F5
CPU_BPM2_N
E7
CPU_BPM1_N
F8
CPU_BPM0_N
F6
DBSY_N
F18
HDRDY_N
E18
HIT_N
E22
HITM_N
A23
HLOCK_N
A17
BERR_N
D7
ADSTB1
F14
ADSTB0
F17
DSTBP3
Y11
DSTBP2
Y14
DSTBP1
Y17
DSTBP0
Y20
DSTBN3
Y12
DSTBN2
Y15
DSTBN1
Y18
DSTBN0
Y21
CPU1_THRMTRIP_N
F26
PROC1_HOT_N
B25
CPU1_COMP1
E16
CPU1_COMP0
AD16
CPU1_GTL_VREF2
F9 F23
CPU1_GTL_VREF1
W9 W23
CPU1_ODTEN
B5
CPU1_SKTOCC_N
A3
CPU1_TESTHI6
AE5
CPU1_TESTHI5
AD5
CPU1_TESTHI4
AA7
CPU1_TESTHI3
Y6
CPU1_TESTHI2
W8
CPU1_TESTHI1
W7
CPU1_TESTHI0
W6
Y28 Y27 Y3 AD1 B1 AE30
CPU1_THERM_DC1 [40]
CPU1_THERM_DA1 [40]
TP39 TP41 TP42 TP373
PRESTONIA
Title
Size Document Number Rev
Date: Sheet of
CPU1_IERR_N [9] ADS_N [5,11] BINIT_N [5,11] BNR_N [5,11]
CPU_BPM5_N [5,6] CPU_BPM4_N [5,6] CPU_BPM3_N [5,6] CPU_BPM2_N [5,6] CPU_BPM1_N [5,6] CPU_BPM0_N [5,6]
DBSY_N [5,11] HDRDY_N [5,11] HIT_N [5,11] HITM_N [5,11] HLOCK_N [5,11] BERR_N [5,11]
ADSTB[0..1]
DSTBP[0..3]
DSTBN[0..3]
CPU1_THRMTRIP_N [9] PROC1_HOT_N [9]
R69 49.9/6/1 R70 49.9/6/1
R71 49.9/6/1
R90 4.7K/6
R72 49.9/6/1 R73 49.9/6/1 R74 49.9/6/1 R75 49.9/6/1 R76 49.9/6/1 R77 49.9/6/1 R78 49.9/6/1
V_CORE
R83
40.2/6/1/X
ADSTB[0..1] [5,11]
DSTBP[0..3] [5,11]
DSTBN[0..3] [5,11]
R84
40.2/6/1/X
R86 680/6
CPU1_SKTOCC_N [48,51]
3VSB
REV:1.2 ADD R1914
R85 75/6
GIGA-BYTE TECHNOLOGY CO., LTD.
CUP2 SIGNAL
GA-8IPP533
1
ITP_TRST_N
V_CORE
R1914 56/6
PROC1_HOT_N
ITP_TDI_P1 ITP_TCK_P ITP_TMS_P
7 58Tuesday, October 21, 2003
1.3
5
V_COREV_CORE
U2C
AD30
VCC1
D D
C C
B B
A A
AC31
AC3
AB30
AB2
AA31
AA1
M3
M1 L30 L28 L26 L24
K31 K29 K27 K25 K23
J30 J28 J26 J24
H31 H29 H27 H25 H23
G30 G28 G26 G24
G8
G6
G4
G2 F31 F29 F22 F16 F10
E30 E28 E26 E20 E12
D31 D29 D24 D18 D14
C30 C28 C22 C16 C10
B31 B29 B26 B20 B12
A30 A28 A24 A18 A14
L8 L6 L4 L2
K9 K7 K5 K3 K1
J8 J6 J4 J2
H9 H7 H5 H3 H1
F4 F1
E6 E2
D8 D1
C4 C2
B6 B4
A8 A2
VCC2 VCC3 VCC4 VCC5 VCC6 VCC7 VCC8 VCC9 VCC10 VCC11 VCC12 VCC13 VCC14 VCC15 VCC16 VCC17 VCC18 VCC19 VCC20 VCC21 VCC22 VCC23 VCC24 VCC25 VCC26 VCC27 VCC28 VCC29 VCC30 VCC31 VCC32 VCC33 VCC34 VCC35 VCC36 VCC37 VCC38 VCC39 VCC40 VCC41 VCC42 VCC43 VCC44 VCC45 VCC46 VCC47 VCC48 VCC49 VCC50 VCC51 VCC52 VCC53 VCC54 VCC55 VCC56 VCC57 VCC58 VCC59 VCC60 VCC61 VCC62 VCC63 VCC64 VCC65 VCC66 VCC67 VCC68 VCC69 VCC70 VCC71 VCC72 VCC73 VCC74 VCC75 VCC76 VCC77 VCC78 VCC79 VCC80 VCC81 VCC82 VCC83 VCC84 VCC85 VCC86 VCC87 VCC88 VCC89 VCC90 VCC91 VCC92 VCC93 VCC94 VCC95
SOCKET-604
Socket 604
Part 3
5
VCC96 VCC97 VCC98
VCC99 VCC100 VCC101 VCC102 VCC103 VCC104 VCC105 VCC106 VCC107 VCC108 VCC109 VCC110 VCC111 VCC112 VCC113 VCC114 VCC115 VCC116 VCC117 VCC118 VCC119 VCC120 VCC121 VCC122 VCC123 VCC124 VCC125 VCC126 VCC127 VCC128 VCC129 VCC130 VCC131 VCC132 VCC133 VCC134 VCC135 VCC136 VCC137 VCC138 VCC139 VCC140 VCC141 VCC142 VCC143 VCC144 VCC145 VCC146 VCC147 VCC148 VCC149 VCC150 VCC151 VCC152 VCC153 VCC154 VCC155 VCC156 VCC157 VCC158 VCC159 VCC160 VCC161 VCC162 VCC163 VCC164 VCC165 VCC166 VCC167 VCC168 VCC169 VCC170 VCC171 VCC172 VCC173 VCC174 VCC175 VCC176 VCC177 VCC178 VCC179 VCC180 VCC181 VCC182 VCC183 VCC184 VCC185 VCC186 VCC187 VCC188 VCC189 VCC190
AE3 Y2 AD2 AE24 AE18 AE14 AE8 AD26 AD20 AD12 AD6 AC22 AC16 AC10 AC4 AB24 AB18 AB14 AB8 AA26 AA20 AA12 AA6 AA4 Y30 Y22 Y16 Y10 W31 W29 W27 W25 W1 V30 V28 V26 V24 V8 V6 V4 V2 U31 U29 U27 U25 U23 U9 U7 U5 U3 U1 T30 T28 T26 T24 T8 T6 T4 T2 R31 R29 R27 R25 R23 R9 R7 R5 R3 R1 P30 P28 P26 P24 P8 P6 P4 P2 N31 N29 N27 N25 N23 N9 N7 N5 N3 N1 M31 M29 M27 M25 M23 M9 M7 M5
NC FOR NOCONA
49.9 ohm FOR NOCONA
R1693
0/6/X
R1694
49.9/6/1
4
U2D
M30
VSS1
M28
VSS2
M26
VSS3
M24
VSS4 VSS5 VSS6 VSS7 VSS8 VSS9 VSS10 VSS11 VSS12 VSS13 VSS14 VSS15 VSS16 VSS17 VSS18 VSS19 VSS20 VSS21 VSS22 VSS23 VSS24 VSS25 VSS26 VSS27 VSS28 VSS29 VSS30 VSS31 VSS32 VSS33 VSS34 VSS35 VSS36 VSS37 VSS38 VSS39 VSS40 VSS41 VSS42 VSS43 VSS44 VSS45 VSS46 VSS47 VSS48 VSS49 VSS50 VSS51 VSS52 VSS53 VSS54 VSS55 VSS56 VSS57 VSS58 VSS59 VSS60 VSS61 VSS62 VSS63 VSS64 VSS65 VSS66 VSS67 VSS68 VSS69 VSS70 VSS71 VSS72 VSS73 VSS74 VSS75 VSS76 VSS77 VSS78 VSS79 VSS80 VSS81 VSS82 VSS83 VSS84 VSS85 VSS86 VSS87 VSS88 VSS89 VSS90 VSS91 VSS92 VSS93 VSS94
SOCKET-604
Socket 604
Part 4
G7 : BOOT_SELECT
C1 : TESTLOW
M8 M6 M4
M2 L31 L29 L27 L25 L23
L9 L7 L5 L3
L1 K30 K28 K26 K24
K8
K6
K4
K2
J31 J29 J27 J25 J23
J9 J7 J5 J3
J1 H30 H28 H26 H24
H8 H6 H4
H2 G31 G29 G27 G25
G9 G7 G5 G3
G1 F30 F28 F25 F19 F13
F7
F2 E31 E29 E23 E17 E15
E9
E1 D30 D28 D27 D21 D11
D5
D2 C31 C29 C25 C19 C13
C7
C1 B30 B28 B23 B17 B15
B9
B2 A31 A29 A27 A21 A11
A5
4
VSS95 VSS96 VSS97 VSS98
VSS99 VSS100 VSS101 VSS102 VSS103 VSS104 VSS105 VSS106 VSS107 VSS108 VSS109 VSS110 VSS111 VSS112 VSS113 VSS114 VSS115 VSS116 VSS117 VSS118 VSS119 VSS120 VSS121 VSS122 VSS123 VSS124 VSS125 VSS126 VSS127 VSS128 VSS129 VSS130 VSS131 VSS132 VSS133 VSS134 VSS135 VSS136 VSS137 VSS138 VSS139 VSS140 VSS141 VSS142 VSS143 VSS144 VSS145 VSS146 VSS147 VSS148 VSS149 VSS150 VSS151 VSS152 VSS153 VSS154 VSS155 VSS156 VSS157 VSS158 VSS159 VSS160 VSS161 VSS162 VSS163 VSS164 VSS165 VSS166 VSS167 VSS168 VSS169 VSS170 VSS171 VSS172 VSS173 VSS174 VSS175 VSS176 VSS177 VSS178 VSS179 VSS180 VSS181 VSS182 VSS183 VSS184 VSS185 VSS186 VSS187 VSS188 VSS189
AE2 AD3 AE27 AE21 AE11 AD31 AD23 AD17 AD15 AD9 AC30 AC25 AC19 AC13 AC7 AC2 AB31 AB27 AB21 AB11 AB5 AB1 AA30 AA23 AA17 AA15 AA9 AA2 Y31 Y25 Y19 Y13 Y7 Y5 Y1 W30 W28 W26 W24 W4 W2 V31 V29 V27 V25 V23 V9 V7 V5 V3 V1 U30 U28 U26 U24 U8 U6 U4 U2 T31 T29 T27 T25 T23 T9 T7 T5 T3 T1 R30 R28 R26 R24 R8 R6 R4 R2 P31 P29 P27 P25 P23 P9 P7 P5 P3 P1 N30 N28 N26 N24 N8 N6 N4 N2
3
AC30 : SLEW_CTRL
FOR NOCONA
V_CORE
3
R1686 0/6/X
R1692 0/6
2
Title
Size Document Number Rev
2
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
CPU2 POWER AND GND
1
GA-8IPP533
1
8 58Tuesday, October 21, 2003
1.3
5
15 14 13 12 11 10
2
R1189 10K/6
2
VCC3
R1567
4.7K/6
2
VCC
CPU1_BOOT_N CPU1_BREQ0_N
R104 10K/6
3
1
Q8 2N2222
3
Q122 2N2222
1
3
Q142
2N7002
1
MCH_BREQ0_N [11]MCH_BREQ0_N[11]
CPU0_BREQ0 [7]
CPU1_BREQ0 [7]
R1729 1K/6
R1731 1K/6
CPU REDUCTION
ICH3_SMI_N[6,36]
D D
C C
CPU1 BRQ0
CPU1 BRQ1
74AHC74 FUNCTION TABLE
B B
PRE#
H H L H
PROC0_HOT_N[5]
A A
PROC1_HOT_N[7]
ICH3_SMI_N
CPU DISABLE BY ICH3 GPO20,GPO21(MAIN POWER)
CPU0_BOOT_N[51]
CPU0_BREQ0_N[5]
CPU1_BREQ0_N[5]
CLK
CLR#
D
H
X
L
H
LQ0L
X
X
H
CPU0_BREQ0_N
V_CORE
Q
R1186
V_CORE
0/6
R1191
0/6
5
R1651
4.7K/6
CPU0_DISABLE_N[37]
CPU1_DISABLE_N[37]
R1673 470/6
R1190 470/6
VCC3
R1566 100/6
3
2
Q141 2N3904
1
CPU0_DISABLE_N
CPU1_DISABLE_N
U150
1 16
NC VCC
2
BE0#
BE3#
3
A0
4
B0
5
BE1#
BE2#
6
A1
7
B1
8 9
GND NC
PI5C3125Q (BUS SWITCH)
R1656 0/6
R1657 0/6
R103
1K/6 R105 470/6
3
2
Q7
2N2222
1
R1188
1K/6 R1192 470/6
3
2
Q121
2N2222
1
A3 B3
A2 B2
VCC3
VCC3
R1732 1K/6
4
VCC3
3VSB
VCC
1 2
VCC
1 2
R1592
4.7K/6/X
CPU0_BOOT_N
R1723 10K/6
53
53
SN74AHC1G08/SOT23-5
SN74AHC1G08/SOT23-5
R1589
4.7K/6
VCC3
R1590
4.7K/6
VCC
R1591
4.7K/6
Q152
3
2N7002
2
CPU0_BOOT_N IS LOW,THEN BOOT FROM CPU1,OTHERWISE BOOT FROM CPU2
1
CPU2 BRQ1
CPU2 BRQ0
3VSB
R1730 1K/6
U155A
1
CLR
2
D
3
CLK
4
PRE
SN74AHC74
U155B
13
CLR
12
D
11
CLK
10
PRE
SN74AHC74
3VSB
R1733 1K/6
RESET CPU HOT CIRCUIT FROM BMC (OD OUTPUT)
4
14
VDD
5
Q
6
Q
7
GND
14
VDD
9
Q
8
Q
7
GND
RESET_CPU_HOT_N
IPMI_PROC0_HOT_N
3VSB
IPMI_PROC1_HOT_N
U135
CPU0_SMI
4
U136
CPU1_SMI
4
CPU0_BOOT_N [51]
CPU1_THRMTRIP_N[7]
CPU0_THRMTRIP_N[5]
RESET_CPU_HOT_N [51]
3
V_CORE
R1571
R1568
4.7K/6
4.7K/6
3
1
3
1
R1179 1K/6
Q119 2N2222
R98 1K/6
Q5 2N2222
VCC3V_CORE
Q120 2N2222
Q6 2N2222
CPU1_SMI CPU0_SMI
2
2
CPU1_SMI_N[7] CPU0_SMI_N[5]
CPU1_SMI_N CPU0_SMI_N
R1181
470/6
R1182
V_CORE VCC3
0/6
R91 470/6
R1184
0/6
R1183 470/6
R100 470/6
2
2
3
1
3
1
1 2 3 4 5 6 7 8
R1180 10K/6
C1652 1U/6
R99 10K/6
C1653 1U/6
U149
1A 1Y 2A 2Y 3A 3Y GND 4Y
7407
R1300 1K/6
R1355 1K/6
REV:1.0 ADD C1652,C1653
IPMI_PROC0_HOT_N [40]
3VSBV_CORE
R1737
R1736
IPMI_PROC1_HOT_N [40]
P0_FORCEPR_N[5] BMC_FORCEPR0_N [51]
P1_FORCEPR_N[7] BMC_FORCEPR1_N [51]
P1_FORCEPR_N BMC_FORCEPR1_N
3
470/6
R1739
0/6/X
V_CORE 3VSB
R1740 470/6
R1743
321
0/6/X
321
Q170 2N2222
Q171 2N2222
470/6
R1741 470/6
R1738 1K/6
BMC_FORCEPR0_NP0_FORCEPR_N
R1742 1K/6
VCC
R1302 1K/6
2
VCC
14 13
6A
12
6Y
11
5A
10
5Y
9
4A
3VSB
R1301 1K/6
U126A
1
CLR
2
D
3
CLK
4
PRE
SN74AHC74 U126B
13
CLR
12
D
11
CLK
10
PRE
SN74AHC74
VCC3
R1303 100/6
R1304 10K/6
CPU0_IERR_N[5,6]
2
14
VDD
5
Q
6
Q
7
GND
3VSB
14
VDD
9
Q
8
Q
7
GND
REV:0.5 CONNECT TO 3VSB
3VSB
R1195
470/6
CPU1_IERR_N[7]
1
3VSB
14
U67B
4 5
1 2
2
R1198
470/6
Title
Size Document Number Rev
Date: Sheet of
6
IPMI_CPU1_THRMTRIP_N [42,48,51]
74LVC08/SO
7
3VSB
14
U67A
3
IPMI_CPU0_THRMTRIP_N [42,48,51]
74LVC08/SO
7
VCC3
VCC3
2
2
3
1
3
1
R1194 300/6
Q124 2N2222
R1197 300/6
Q126 2N2222
IPMI_IERR0_N [51]
IPMI_IERR1_N [51]
R1193 470/6
3
Q123 2N2222
1
R1196 470/6
3
2
Q125 2N2222
1
GIGA-BYTE TECHNOLOGY CO., LTD. LEVEL SHIFT
GA-8IPP533
1
9 58Tuesday, October 21, 2003
1.3
5
V_CORE
C17
C18
100U/1210
D D
V_CORE
100U/1210
C19 100U/1210
C20 1U/8
C21 1U/8
C22 1U/8
C23 1U/8
C24 1U/8
C1535
100U/1210
4
PROCESSOR 1
C1536
C1537
100U/1210
100U/1210
C1538
100U/1210
C1541
100U/1210
3
Place on CPU0 Address Side
V_CORE
C51 1U/6
C52 1U/6
C53 1U/6
C54 1U/6
V_CORE
2
C35
0.1U/6
C26 22U/12
C36
0.1U/6
C27 22U/12
C37
0.1U/6
C28 22U/12
C38
0.1U/6
C39
0.1U/6
C30 100U/1210
C40
0.1U/6
1
C31 100U/1210
C41
0.1U/6
C32 100U/1210
C42
0.1U/6
C33 100U/1210
C43
0.1U/6
C34 100U/1210
C44
0.1U/6
EC7
EC2 1500U/2.5V
SBC1 100U/1210
EC3 1500U/2.5V
SBC2 100U/1210
EC1 1500U/2.5V
V_CORE
C C
EC4 1500U/2.5V
SBC3 100U/1210
EC5 1500U/2.5V
SBC4 100U/1210
EC6 1500U/2.5V
SBC5 100U/1210
1500U/2.5V
SBC6 100U/1210
EC101 1500U/2.5V
SBC7 100U/1210
EC102 1500U/2.5V
EC103 1500U/2.5V
EC104 1500U/2.5V
100U/1210
C1420
V_CORE
C1421
100U/1210
C45 1U/6
C46 1U/6
C1423
100U/1210
Place on CPU0 Data Side
C1497
100U/1210
100U/1210
V_CORE
C75
V_CORE
100U/1210
C1504
1U/8
EC11 1500U/2.5V
B B
V_CORE
V_CORE
A A
C1501
SBC9 100U/1210
C1505
100U/1210
C1502
C1503
100U/1210
100U/1210
C1417
100U/1210
PROCESSOR 2
C78
C77
C76 1U/8
EC12 1500U/2.5V
SBC10 100U/1210
1U/8
EC14 1500U/2.5V
SBC11 100U/1210
C1453
100U/1210
100U/1210
EC16 1500U/2.5V
SBC12 100U/1210
C1457
100U/1210
C79 100U/1210
EC17 1500U/2.5V
100U/1210
SBC8 100U/1210
C80 100U/1210
SBC13 100U/1210
C1458
SBC52 22U/12
C81 100U/1210
EC105 1500U/2.5V
SBC14 100U/1210
C1462
100U/1210
SBC53 22U/12
C82 1U/8
SBC15 100U/1210
SBC16 100U/1210
SBC99 100U/1210
SBC74 22U/1206
SBC100 100U/1210
SBC75 22U/1206
SBC101 100U/1210
V_CORE
SBC102
SBC103
100U/1210
100U/1210
Place on CPU1 Address Side
V_CORE
Place on CPU1 Data Side
C103
C104 1U/6
C105 1U/6
1U/6
GALLATIN/PRESTONIA PROCESSOR 0/1 DECOUPLING
5
4
3
C47 1U/6
SBC104 100U/1210
C106 1U/6
C1424
100U/1210
C48 1U/6
C1419
100U/1210
C109 1U/6
C107 1U/6
C49 1U/6
C110 1U/6
V_CORE
C108 1U/6
C50 1U/6
C111 1U/6
C112 1U/6
V_CORE
SBC92 100U/1210
V_CORE
V_CORE
SBC93 100U/1210
SBC32
0.1U/6
SBC42
0.1U/6
SBC54
0.1U/6
SBC64
0.1U/6
SBC94 100U/1210
SBC33
0.1U/6
SBC43
0.1U/6
C83 22U/12
C93
0.1U/6
SBC55
0.1U/6
SBC65
0.1U/6
2
BACKSIDE CAPS
SBC34
0.1U/6
SBC44
0.1U/6
C84 22U/12
C94
0.1U/6
SBC56
0.1U/6
SBC66
0.1U/6
SBC95
SBC96
100U/1210
100U/1210
SBC36
SBC35
0.1U/6
SBC45
0.1U/6
C85 22U/12
C95
0.1U/6
SBC57
0.1U/6
SBC67
0.1U/6
SBC37
0.1U/6
0.1U/6
SBC46
SBC47
0.1U/6
0.1U/6
C87
C86
22U/12
22U/12
C97
C96
0.1U/6
0.1U/6
SBC59
SBC58
0.1U/6
0.1U/6
SBC68
SBC69
0.1U/6
0.1U/6
Title
Size Document Number Rev
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
CPU DECOUPLING
SBC38
0.1U/6
SBC48
0.1U/6
C88 22U/12
C98
0.1U/6
SBC60
0.1U/6
SBC70
0.1U/6
SBC39
0.1U/6
SBC49
0.1U/6
C89 22U/12
C100
C99
0.1U/6
0.1U/6
SBC61
0.1U/6
SBC71
0.1U/6
GA-8IPP533
1
SBC40
0.1U/6
SBC50
0.1U/6
SBC62
0.1U/6
SBC72
0.1U/6
C101
0.1U/6
10 58Tuesday, October 21, 2003
SBC41
0.1U/6
SBC51
0.1U/6
SBC63
0.1U/6
SBC73
0.1U/6
C102
0.1U/6
1.3
5
H_CLKINN[46] H_CLKINP[46]
R110 24.9/6/1
DSTBP[0..3][5,7]
DSTBN[0..3][5,7]
RSP_N[5,7]
RS[0..2][5,7]
ADSTB[0..1][5,7]
HYSWING
C150
0.01U/6
HA[3..35][5,7]
DBI[0..3][5,7]
DP[0..3][5,7]
R111 24.9/6/1
DSTBP[0..3]
DSTBN[0..3]
RS[0..2]
ADSTB[0..1]
HA[3..35]
DBI[0..3]
DP[0..3]
BINIT_N[5,7]
ICH3_PWROK[31,38,48]
HDRDY_N[5,7]
DEFER_N[5,7]
DBSY_N[5,7]
CPURST_N[5,6,7]
MCH_BREQ0_N[9]
BPRI_N[5,7]
BNR_N[5,7]
BERR_N[5,7]
AP0_N[5,7] AP1_N[5,7] ADS_N[5,7]
R131 301/6/1
R133 150/6/1
5
D D
C C
B B
A A
H_CLKINN H_CLKINP
HYCOMP HXCOMP
HYSWING HXSWING
DSTBP0 DSTBP1 DSTBP2 DSTBP3
DSTBN0 DSTBN1 DSTBN2 DSTBN3
RSP_N
RS0 RS1 RS2
ADSTB0 ADSTB1
HA3 HA4 HA5 HA6 HA7 HA8 HA9 HA10 HA11 HA12 HA13 HA14 HA15 HA16 HA17 HA18 HA19 HA20 HA21 HA22 HA23 HA24 HA25 HA26 HA27 HA28 HA29 HA30 HA31 HA32 HA33 HA34 HA35
DBI0 DBI1 DBI2 DBI3
DP0 DP1 DP2 DP3
BINIT_N ICH3_PWROK
HDRDY_N DEFER_N DBSY_N CPURST_N
BPRI_N BNR_N BERR_N AP0_N AP1_N ADS_N
HXSWING
C151
0.01U/6
R108
4.7K/6/1
V_COREV_CORE
VCC3
U3A
C29 AB2
XORMODE_N HREQ0_N
U3
H_CLKINN
T2
H_CLKINP
G5
HYRCOMP
V4
HXRCOMP
K5
HYSWING
V8
HXSWING
B8
HDSTBP0_N
H6
HDSTBP1_N
J4
HDSTBP2_N
P3
HDSTBP3_N
B6
HDSTBN0_N
K6
HDSTBN1_N
J2
HDSTBN2_N
R4
HDSTBN3_N
AK4
RSP_N
V2
RS0_N
V5
RS1_N
U4
RS2_N
AE1
HADSTB0_N
AD7
HADSTB1_N
AA8
HA3_N
AB1
HA4_N
AC3
HA5_N
AD2
HA6_N
AB6
HA7_N
AC4
HA8_N
AD4
HA9_N
AE5
HA10_N
AE2
HA11_N
AC6
HA12_N
AB9
HA13_N
AE6
HA14_N
AE3
HA15_N
AD5
HA16_N
AB8
HA17_N
AC7
HA18_N
AC9
HA19_N
AH2
HA20_N
AH3
HA21_N
AG2
HA22_N
AF6
HA23_N
AD8
HA24_N
AF1
HA25_N
AG4
HA26_N
AJ4
HA27_N
AE8
HA28_N
AF3
HA29_N
AF7
HA30_N
AH5
HA31_N
AG7
HA32_N
AH6
HA33_N
AJ1
HA34_N
AG5
HA35_N
F8
DBI0_N
D2
DBI1_N
L4
DBI2_N
P1
DBI3_N
Y4
DP0_N
AA2
DP1_N
AA5
DP2_N
AA4
DP3_N
AG8
BINIT_N
A28
PWRGOOD
Y3
DRDY_N
W8
DEFER_N
W6
DBSY_N
W9
CPURST_N
AF9
BREQ0_N
U6
BPRI_N
V1
BNR_N
AK2
XERR_N
AJ6
AP0_N
AK5
AP1_N
Y7
ADS_N
U3
R1298
4.7K/6
VCC3
MCH_RSVD_02
R132 301/6/1
R134
150/6/1
4
HTRDY_N HLOCK_N HITM_N HIT_N
C133 1U/8
-HREQ[0..4]
R113
86.6/6/1
HD[0..63]
HREQ1_N HREQ2_N HREQ3_N HREQ4_N
HTRDY_N
HLOCK_N
HITM_N
HIT_N
HAVREF0 HAVREF1
HCCVREF HDVREF0
HDVREF1 HDVREF2 HDVREF3
HD63_N HD62_N HD61_N HD60_N HD59_N HD58_N HD57_N HD56_N HD55_N HD54_N HD53_N HD52_N HD51_N HD50_N HD49_N HD48_N HD47_N HD46_N HD45_N HD44_N HD43_N HD42_N HD41_N HD40_N HD39_N HD38_N HD37_N HD36_N HD35_N HD34_N HD33_N HD32_N HD31_N HD30_N HD29_N HD28_N HD27_N HD26_N HD25_N HD24_N HD23_N HD22_N HD21_N HD20_N HD19_N HD18_N
Plumas MCH System Bus I/F
HD17_N HD16_N HD15_N HD14_N HD13_N HD12_N HD11_N HD10_N
HD9_N HD8_N HD7_N HD6_N HD5_N HD4_N HD3_N HD2_N HD1_N HD0_N
4
-HREQ2
AA7
-HREQ3
AB3
-HREQ4
Y9 W3
V7 W5 U1
AF4 AJ3
Y6 C5
N8 P6 T7
HD63
T8
HD62
R5
HD61
T5
HD60
T9
HD59
U7
HD58
T3
HD57
T6
HD56
R2
HD55
N1
HD54
N3
HD53
N2
HD52
L2
HD51
M2
HD50
P4
HD49
N4
HD48
L3
HD47
R8
HD46
R7
HD45
N7
HD44
P7
HD43
M4
HD42
P9
HD41
J5
HD40
N6
HD39
K1
HD38
K2
HD37
J1
HD36
G3
HD35
K3
HD34
G2
HD33
H3
HD32
H4
HD31
M7
HD30
F1
HD29
E3
HD28
F2
HD27
D3
HD26
F4
HD25
E1
HD24
M8
HD23
E4
HD22
F5
HD21
D6
HD20
G6
HD19
E6
HD18
L6
HD17
L7
HD16
F7
HD15
J7
HD14
J8
HD13
C2
HD12
H7
HD11
D7
HD10
C7
HD9
C4
HD8
A8
HD7
C8
HD6
A5
HD5
B3
HD4
E8
HD3
B5
HD2
A4
HD1
A9
HD0
B9
MCH_RSVD_01
R1299 1K/6
-HREQ0
-HREQ1
AA1
-HREQ[0..4] [5,7]
HTRDY_N [5,7] HLOCK_N [5,7] HITM_N [5,7] HIT_N [5,7]
R112
51/6/1
V_CORE
NOCONA
R113 100 ohm 1%
86.6 ohm 1%
HD[0..63] [5,7]
3
PROSTENIA
3
VCC1_2
ICH3_SMBDATA[15,16,19,20,24,37,46] ICH3_SMBCLK[15,16,19,20,24,37,46]
ICH3_HI[0..11][36]
C134
0.1U/6
C142
0.1U/6
2
U3B
G13
HI21_B
F14
HI20_B
E14
HI18_B
B17
HI17_B
H14
HI16_B
J14
HI15_B
C11
HI14_B
E12
HI13_B
D12
HI12_B
C13
HI11_B
A13
HI10_B
F13
HI9_B
C14
HI8_B
D15
HI7_B
B14
HI6_B
A16
HI5_B
A17
HI4_B
C16
HI3_B
C17
HI2_B
G16
HI1_B
D16
HI0_B
G15
PSTRBF_B
H15
PSTRBS_B
A12
PUSTRBF_B
B12
47/6
G10
G12
R120
453/6/1/X
R124
499/6/1/X
R128
392/6/1
PUSTRBS_B
E15
HI_RCONP_B
B15
HISWNG_B
D13
HIVREF_B
B31
SMB_DATA
J25
SMB_CLK
B30
RESERVED02
D29
RESERVED01
J16
CLK66
E28
RSTIN_N
H12
HISWNG_A
G9
HI_VREF_A
H11
HI_RCOMP_A
D10
PSTRBS_A
C10
PSTRBF_A
E11
HI0_A
B11
HI1_A HI2_A
F10
HI3_A
D9
HI4_A
E9
HI5_A
J11
HI6_A
H9
HI7_N
J13
HI8_A
J10
HI9_N
F11
HI10_A HI11_N
HI_VSWING_B
HI_VREF_B
Plumas MCH Hub Interfaces
U3
C138
C137
0.1U/6/X
0.01U/6/X
C145
C146
0.01U/6/X
0.1U/6/X
2
R114 24.9/6/1/X
ICH3_SMBDATA ICH3_SMBCLK
MCH_CLK66[46]
PCIRST2_5_N[15,16,19,20,36]
VCC2_5
VCC1_2
R118 24.9/6/1
ICH3_PSTRBS[36] ICH3_PSTRBF[36]
ICH3_HI[0..11]
VCC1_2 VCC1_2 VCC1_2 VCC1_2
R119 453/6/1
HI_VSWING_A
R123
499/6/1
HI_VREF_A
R127
392/6/1
HI_RCOMP_B HI_VSWING_B HI_VREF_B
R1774
MCH_RSVD_02
TP43
MCH_RSVD_01
TP44
R117 100/6
HI_VSWING_A HI_VREF_A
HI_RCOMP_A
ICH3_PSTRBS ICH3_PSTRBF
ICH3_HI0 ICH3_HI1 ICH3_HI2 ICH3_HI3 ICH3_HI4 ICH3_HI5 ICH3_HI6 ICH3_HI7 ICH3_HI8 ICH3_HI9 ICH3_HI10 ICH3_HI11
C136
C135
0.1U/6/X
0.01U/6
C144
C143
0.1U/6/X
0.01U/6
F16
HI21_C
H18
HI20_C
F20
HI18_C
C24
HI17_C
B21
HI16_C
F17
HI15_C
E18
HI14_C
C18
HI13_C
B18
HI12_C
C19
HI11_C
B20
HI10_C
A20
HI9_C
D19
HI8_C
E21
HI7_C
D21
HI6_C
F19
HI5_C
E20
HI4_C
C22
HI3_C
G18
HI2_C
B24
HI1_C
D22
HI0_C
C23
PSTRBF_C
B23
PSTRBS_C
D18
PUSTRBF_C
E17
PUSTRBS_C
HI_RCONP_C
HISWWG_C
HIVREF_C
HIVREF_D
HISWNG_D
HI_RCOMP_D
PUSTRBS_D PUSTRBF_D
PSTRBS_D PSTRBF_D
HI0_D HI1_D HI2_D HI3_D HI4_D HI5_D HI6_D HI7_D HI8_D
HI9_D HI10_D HI11_D HI12_D HI13_D HI14_D HI15_D HI16_D HI17_D HI18_D
HI20_D HI21_D
453/6/1/X
499/6/1/X
392/6/1
HI_RCOMP_C
C20
HI_VSWING_C
H17
HI_VREF_C
A21
HI_VREF_D
J22
HI_VSWING_D
F24
HI_RCOMP_D
G21
P1_PUSTRBS
C25
P1_PUSTRBF
B25
P1_PSTRBS
D26
P1_PSTRBF
D27
P1_HI0
D28
P1_HI1
G25
P1_HI2
G26
P1_HI3
F26
P1_HI4
G24
P1_HI5
A27
P1_HI6
H24
P1_HI7
C26
P1_HI8
G22
P1_HI9
E24
P1_HI10
A25
P1_HI11
D24
P1_HI12
A24
P1_HI13
E23
P1_HI14
F23
P1_HI15
F22
P1_HI16
H23
P1_HI17
H25
P1_HI18
F25
P1_HI20
E27
P1_HI21
H21
R121
HI_VSWING_C
R125
HI_VREF_C
R129
Title
Size Document Number Rev
Date: Sheet of
R115 24.9/6/1/X
C139
0.01U/6/X
C140
0.1U/6
C147
C148
0.01U/6/X
0.1U/6
GIGA-BYTE TECHNOLOGY CO., LTD.
MCH-CPU AND HUB INTERFACE
1
R116 24.9/6/1
P1_PUSTRBS [24] P1_PUSTRBF [24] P1_PSTRBS [24] P1_PSTRBF [24]
P1_HI[0..15]
P1_HI16 [24] P1_HI17 [24] P1_HI18 [24]
P1_HI20 [24] P1_HI21 [24]
R122
453/6/1
R126
499/6/1
R130
392/6/1
GA-8IPP533
1
VCC1_2
VCC1_2
P1_HI[0..15] [24]
HI_VSWING_D
C141
0.01U/6
HI_VREF_D
C149
0.01U/6
11 58Tuesday, October 21, 2003
1.3
5
U3C
VTT_DDR
AF22 AN28 AE21 AH22
AM27
AF21 AN29
AM28
AL26 AL25
AN25 AM24 AG21
AE20
AL23
AK23 AM25
AK24
AL22
AJ22 AK19 AL19 AN17 AF18
AG18
AK18 AN20
AM19
AL17
AJ18 AF19 AH19
AM21
AL20 AE18 AK20 AH20
AJ21 AN21
AJ19 AL14
AM13
AJ15 AF15 AL13
AJ13 AK14 AN13 AH14
AG14
AE14 AH13 AN12 AL11
AM12
AK12 AE15 AF13
AJ12
AM10
AE12 AH11
AG11
AN5 AL8
AM7
AG12
AF12
AM9 AM6
AG10
AJ9 AM3 AM2
AL6
AH9 AH10 AE11
AL5
AM4 AE16 AH16 AL16 AK15
AJ16 AF16 AE17
AG17 AM15 AG15
R162
6.98K/6/1
R166 13K/6
DQ0_A DQ1_A DQ2_A DQ3_A DQS0_A DQS9_A DQ4_A DQ5_A DQ6_A DQ7_A DQ8_A DQ9_A DQ10_A DQ11_A DQS1_A DQS10_A DQ12_A DQ13_A DQ14_A DQ15_A DQ16_A DQ17_A DQ18_A DQ19_A DQS2_A DQS11_A DQ20_A DQ21_A DQ22_A DQ23_A DQ24_A DQ25_A DQ26_A DQ27_A DQS3_A DQS12_A DQ28_A DQ29_A DQ30_A DQ31_A DQ32_A DQ33_A DQ34_A DQ35_A DQS4_A DQS13_A DQ36_A DQ37_A DQ38_A DQ39_A DQ40_A DQ41_A DQ42_A DQ43_A DQS5_A DQS14_A DQ44_A DQ45_A DQ46_A DQ47_A DQ48_A DQ49_A DQ50_A DQ51_A DQS6_A DQS15_A DQ52_A DQ53_A DQ54_A DQ55_A DQ56_A DQ57_A DQ58_A DQ59_A DQS7_A DQS16_A DQ60_A DQ61_A DQ62_A DQ63_A CB0_A CB1_A CB2_A CB3_A DQS8_A DQS17_A CB4_A CB5_A CB6_A CB7_A
DDRCVOL_A
C160
0.01U/6
C161
0.1U/6
RCVEN_OUT_A
MCH DDR A
CMDCLK3_N_A CMDCLK2_N_A
CMDCLK_N_A
CMDCLK0_N_A
WE_N_A CAS_N_A RAS_N_A
MA0_A MA1_A MA2_A MA3_A MA4_A MA5_A MA6_A MA7_A MA8_A
MA9_A MA10_A MA11_A MA12_A
BA1_A BA0_A
CS7_N_A CS6_N_A CS5_N_A CS4_N_A CS3_N_A CS2_N_A CS1_N_A CS0_N_A
RCVEN_IN_A
DDRCOMP_A
DDRCVDH_A DDRCVDL_A
CKE_A
RESERVED CMDCLK3_A CMDCLK2_A
CMDCLK1_A CMDCLK0_A
DDRVREF5_A DDRVREF4_A DDRVREF3_A DDRVREF2_A DDRVREF1_A DDRVREF0_A
U3
D DRA_CMDCLK0_N
C1267 10P/6/X
DDRA_DQ0[14] DDRA_DQ1[14] DDRA_DQ2[14] DDRA_DQ3[14]
DQS0_A[14]
DQS9_A[14] DDRA_DQ4[14] DDRA_DQ5[14]
DDRA_DQ6[14] DDRA_DQ7[14]
D D
C C
B B
VCC2_5
A A
VTT_DDR
DDRA_DQ8[14] DDRA_DQ9[14] DDRA_DQ10[14] DDRA_DQ11[14]
DQS1_A[14]
DQS10_A[14] DDRA_DQ12[14] DDRA_DQ13[14]
DDRA_DQ14[14] DDRA_DQ15[14] DDRA_DQ16[14] DDRA_DQ17[14] DDRA_DQ18[14] DDRA_DQ19[14]
DQS2_A[14]
DQS11_A[14] DDRA_DQ20[14] DDRA_DQ21[14]
DDRA_DQ22[14] DDRA_DQ23[14] DDRA_DQ24[14] DDRA_DQ25[14] DDRA_DQ26[14] DDRA_DQ27[14]
DQS3_A[14]
DQS12_A[14] DDRA_DQ28[14] DDRA_DQ29[14]
DDRA_DQ30[14] DDRA_DQ31[14] DDRA_DQ32[14] DDRA_DQ33[14] DDRA_DQ34[14] DDRA_DQ35[14]
DQS4_A[14]
DQS13_A[14] DDRA_DQ36[14] DDRA_DQ37[14] DDRA_DQ38[14] DDRA_DQ39[14] DDRA_DQ40[14] DDRA_DQ41[14] DDRA_DQ42[14] DDRA_DQ43[14]
DQS5_A[14]
DQS14_A[14] DDRA_DQ44[14] DDRA_DQ45[14] DDRA_DQ46[14] DDRA_DQ47[14] DDRA_DQ48[14] DDRA_DQ49[14] DDRA_DQ50[14] DDRA_DQ51[14]
DQS6_A[14]
DQS15_A[14] DDRA_DQ52[14] DDRA_DQ53[14] DDRA_DQ54[14] DDRA_DQ55[14] DDRA_DQ56[14] DDRA_DQ57[14] DDRA_DQ58[14] DDRA_DQ59[14]
DQS7_A[14]
DQS16_A[14] DDRA_DQ60[14] DDRA_DQ61[14] DDRA_DQ62[14] DDRA_DQ63[14]
CB0_A[14]
CB1_A[14]
CB2_A[14]
CB3_A[14]
DQS8_A[14]
DQS17_A[14]
CB4_A[14]
CB5_A[14]
CB6_A[14]
CB7_A[14]
E7500 E7501 13K 49.9 1%
R161: R165: 13K NOPOP
0.01U 49.9 1%
C158: 13K
R161
49.9/6/1
DDRCVOH_A
C159
C158
49.9/6/1
0.1U/6
5
R165
6.98K/6/1/X
AE23 AE22 AN24 AF24 AK26 AH26 AJ27 AG27 AH28 AL28 AL29 AK29 AM30 AJ24 AK30 AM31
AH23 AL31
AL2 AL3 AK7 AN8 AH8 AL10 AK11 AE13
AM22 AG20 AH17 AK17 AN16
AE19
R139 0/6 R141 0/6/X
AM18 AE25
AE24 AG26
R143 0/6 R145 0/6
AF25 AJ25
R147 0/6
AH25
R149 0/6
AG24
R151 0/6 R153 0/6
AG23 AJ28
R1400 0/6/X
AK27
R1401 0/6/X
AK21 AM16 AL9 AJ7
R1408
402/6/1
E7500 E7501
DDRA_CMDCLK0
C1269
C1268
10P/6/X
10P/6/X
4
DDRA_WE_N_R [15,16,17] DDRA_CAS_N_R [15,16,17] DDRA_RAS_N_R [15,16,17] DDRA_MA0_R [15,16,17] DDRA_MA1_R [15,16,17] DDRA_MA2_R [15,16,17] DDRA_MA3_R [15,16,17] DDRA_MA4_R [15,16,17] DDRA_MA5_R [15,16,17] DDRA_MA6_R [15,16,17] DDRA_MA7_R [15,16,17] DDRA_MA8_R [15,16,17] DDRA_MA9_R [15,16,17] DDRA_MA10_R [15,16,17] DDRA_MA11_R [15,16,17] DDRA_MA12_R [15,16,17]
DDRA_BA1_R [15,16,17] DDRA_BA0_R [15,16,17]
DDRA_CS7_N_R [21] DDRA_CS6_N_R [21] DDRA_CS5_N_R [16,17] DDRA_CS4_N_R [16,17] DDRA_CS3_N_R [15,17] DDRA_CS2_N_R [15,21] DDRA_CS1_N_R [15,17] DDRA_CS0_N_R [15,17]
DDRA_DRCOMP DDRCVOH_A
R1406 0/6/X
DDRA_RCVEN_IN D DRA_RCVEN_OUT
402 1%NOPOPR1408:
D DRA_CMDCLK1_N
DDRA_CMDCLK1
C1270 10P/6/X
4
3
DDRB_DQ0[18] DDRB_DQ1[18] DDRB_DQ2[18] DDRB_DQ3[18]
DQS0_B[18]
DQS9_B[18] DDRB_DQ4[18] DDRB_DQ5[18] DDRB_DQ6[18] DDRB_DQ7[18] DDRB_DQ8[18] DDRB_DQ9[18] DDRB_DQ10[18] DDRB_DQ11[18]
DQS1_B[18]
DQS10_B[18] DDRB_DQ12[18] DDRB_DQ13[18] DDRB_DQ14[18] DDRB_DQ15[18] DDRB_DQ16[18] DDRB_DQ17[18] DDRB_DQ18[18] DDRB_DQ19[18]
DQS2_B[18]
DQS11_B[18] DDRB_DQ20[18] DDRB_DQ21[18] DDRB_DQ22[18] DDRB_DQ23[18] DDRB_DQ24[18] DDRB_DQ25[18] DDRB_DQ26[18]
E7500 E7501 R1406: 0 R218: R135: R1404: R137:
R1404 24.9/6/1 R137 6.81/6/X
DDRCVOL_A
R218 0/6/X R219 0/6
DDRA_CKE0 [15,16,17] DDRA_CKE1 [15,16,17]
DDRA_CMDCLK2 [16] D DRA_CMDCLK2_N [16]
DDRA_CMDCLK1 [15] D DRA_CMDCLK1_N [15] DDRA_CMDCLK0 [15] D DRA_CMDCLK0_N [15]
E7500 E7501
0R1400: NOPOP
R1401: NOPOP0 R1402:0NOPOP0
C153 0.1U/6
C155 0.1U/6
C157 0.1U/6
VREF_DDR_MCH [15,16,19,20,52]
D DRA_CMDCLK2_N
DDRA_CMDCLK2
C1271
C1272
10P/6/X
10P/6/X
NOPOP NOPOP
0
49.9 1%
47 1%
NOPOP
25 1%
6.81 1%
NOPOP
VTT_DDR
R135 49.9/6/1
C275 22P/6
VTT_DDR
R135 CLOSE TO R218 R136 CLOSE
VCC2_5
R163
49.9/6/1
R167
6.98K/6/1/X
VTT_DDR
DDRB_DQ27[18]
DDRB_DQ28[18] DDRB_DQ29[18] DDRB_DQ30[18] DDRB_DQ31[18] DDRB_DQ32[18] DDRB_DQ33[18] DDRB_DQ34[18] DDRB_DQ35[18]
DDRB_DQ36[18] DDRB_DQ37[18] DDRB_DQ38[18] DDRB_DQ39[18] DDRB_DQ40[18] DDRB_DQ41[18] DDRB_DQ42[18] DDRB_DQ43[18]
DDRB_DQ44[18] DDRB_DQ45[18] DDRB_DQ46[18] DDRB_DQ47[18] DDRB_DQ48[18] DDRB_DQ49[18] DDRB_DQ50[18] DDRB_DQ51[18]
DDRB_DQ52[18] DDRB_DQ53[18] DDRB_DQ54[18] DDRB_DQ55[18] DDRB_DQ56[18] DDRB_DQ57[18] DDRB_DQ58[18] DDRB_DQ59[18]
DDRB_DQ60[18] DDRB_DQ61[18] DDRB_DQ62[18] DDRB_DQ63[18]
E7500 E7501 13K
R163: R167: C162:
0.01U
DDRCVOH_B
C162
49.9/6/1
3
DQS3_B[18] DQS12_B[18]
DQS4_B[18] DQS13_B[18]
DQS5_B[18] DQS14_B[18]
DQS6_B[18] DQS15_B[18]
DQS7_B[18] DQS16_B[18]
DQS8_B[18] DQS17_B[18]
CB0_B[18] CB1_B[18] CB2_B[18] CB3_B[18]
CB4_B[18] CB5_B[18] CB6_B[18] CB7_B[18]
C163
0.1U/6
49.9 1% NOPOP
49.9 1%
DDRB_DQ0 DDRB_DQ1 DDRB_DQ2
DDRB_DQ3 DQS0_B DQS9_B
DDRB_DQ4
DDRB_DQ5
DDRB_DQ6
DDRB_DQ7
DDRB_DQ8
DDRB_DQ9
DDRB_DQ10
DDRB_DQ11
DQS1_B
DQS10_B
DDRB_DQ12
DDRB_DQ13
DDRB_DQ14
DDRB_DQ15
DDRB_DQ16
DDRB_DQ17
DDRB_DQ18
DDRB_DQ19
DQS2_B
DQS11_B
DDRB_DQ20
DDRB_DQ21
DDRB_DQ22
DDRB_DQ23
DDRB_DQ24
DDRB_DQ25
DDRB_DQ26
DDRB_DQ27
DQS3_B DQS12_B DDRB_DQ28 DDRB_DQ29 DDRB_DQ30 DDRB_DQ31 DDRB_DQ32 DDRB_DQ33 DDRB_DQ34 DDRB_DQ35 DQS4_B DQS13_B DDRB_DQ36 DDRB_DQ37 DDRB_DQ38 DDRB_DQ39 DDRB_DQ40 DDRB_DQ41 DDRB_DQ42 DDRB_DQ43 DQS5_B DQS14_B DDRB_DQ44 DDRB_DQ45 DDRB_DQ46 DDRB_DQ47 DDRB_DQ48 DDRB_DQ49 DDRB_DQ50 DDRB_DQ51 DDRB_DQS6 DDRB_DQS15 DDRB_DQ52 DDRB_DQ53 DDRB_DQ54 DDRB_DQ55 DDRB_DQ56 DDRB_DQ57 DDRB_DQ58 DDRB_DQ59 DQS7_B DQS16_B DDRB_DQ60 DDRB_DQ61 DDRB_DQ62 DDRB_DQ63 DDRB_CB0 DDRB_CB1 DDRB_CB2 DDRB_CB3 DQS8_B DQS17_B DDRB_CB4 DDRB_CB5 DDRB_CB6 DDRB_CB7
VTT_DDR
R164
6.98K/6/1
R168 13K/6
F33 K30
J32 N25 L30 H31 N27
G32 M29
N26
J33 K32 P27 P25
M31
N29
J31 L31 P26 P28 T29 T30 U30 T26 U33 U31 R32 T27 V33 V31 P30 P33 R26 T32 R29 R31 N32 P31 R28 T25
W27 AE33 AF31
W25 AE32 AC30 AA28 AD32
AG33
W26 AA29 AB33
V26 AD31 AC31 AB30
Y28 AB32 AB29
V25
Y25 AB27 AH32 AH31 AE28 AD27 AC28 AA26
AG30
AH33
AJ30
AG29
AB25 AA25 AE27 AF28 AL32
AJ31 AC27 AB26
V28 U25 Y31
AA33
W29
Y30 U28
U27 AA31 AA32
DDRCVOL_B
C164
0.01U/6
U3D
DQ0_B DQ1_B DQ2_B DQ3_B DQS0_B DQS9_B DQ4_B DQ5_B DQ6_B DQ7_B DQ8_B DQ9_B DQ10_B DQ11_B DQS1_B DQS10_B DQ12_B DQ13_B DQ14_B DQ15_B DQ16_B DQ17_B DQ18_B DQ19_B DQS2_B DQS11_B DQ20_B DQ21_B DQ22_B DQ23_B DQ24_B DQ25_B DQ26_B DQ27_B DQS3_B DQS12_B DQ28_B DQ29_B DQ30_B DQ31_B DQ32_B DQ33_B DQ34_B DQ35_B DQS4_B DQS13_B DQ36_B DQ37_B DQ38_B DQ39_B DQ40_B DQ41_B DQ42_B DQ43_B DQS5_B DQS14_B DQ44_B DQ45_B DQ46_B DQ47_B DQ48_B DQ49_B DQ50_B DQ51_B DQS6_B DQS15_B DQ52_B DQ53_B DQ54_B DQ55_B DQ56_B DQ57_B DQ58_B DQ59_B DQS7_B DQS16_B DQ60_B DQ61_B DQ62_B DQ63_B CB0_B CB1_B CB2_B CB3_B DQS8_B DQS17_B CB4_B CB5_B CB6_B CB7_B
U3
C165
0.1U/6
2
2
RCVEN_OUT_B
MCH DDR B
CMDCLK3_N_B CMDCLK2_N_B
CMDCLK0_N_B
WE_N_B CAS_N_B RAS_N_B
MA0_B MA1_B MA2_B MA3_B MA4_B MA5_B MA6_B MA7_B MA8_B
MA9_B MA10_B MA11_B MA12_B
BA1_B BA0_B
CS7_N_B CS6_N_B CS5_N_B CS4_N_B CS3_N_B CS2_N_B CS1_N_B CS0_N_B
RCVEN_IN_B
DDRCOMP_B
DDRCVDH_B DDRCVDL_B
RESERVED
CKE_B CMDCLK3_B CMDCLK2_B
CMDCLK1_B
CMDCLK_N_B
CMDCLK0_B
DDRVREF5_B DDRVREF4_B DDRVREF3_B DDRVREF2_B DDRVREF1_B DDRVREF0_B
D32 H28 V32 M26 K29 H30 G30 F32 G29 F31 E33 E31 F29 L25 C31 C32
H27 K26
Y27 AD28 AE26 AE31 AF27 AF30 AK32 AH29
N30 R25 W30 W32 V29
K33 M32
K27 L27 J26 K25
L28 M28 J29 J28
E30 M25 N33 U26 AG32 AC25
DDRB_WE_N_R [19,20,21] DDRB_CAS_N_R [19,20,21] DDRB_RAS_N_R [19,20,21] DDRB_MA0_R [19,20,21] DDRB_MA1_R [19,20,21] DDRB_MA2_R [19,20,21] DDRB_MA3_R [19,20,21] DDRB_MA4_R [19,20,21] DDRB_MA5_R [19,20,21] DDRB_MA6_R [19,20,21] DDRB_MA7_R [19,20,21] DDRB_MA8_R [19,20,21] DDRB_MA9_R [19,20,21] DDRB_MA10_R [19,20,21] DDRB_MA11_R [19,20,21] DDRB_MA12_R [19,20,21]
DDRB_BA1_R [19,20,21] DDRB_BA0_R [19,20,21]
DDRB_CS7_N_R [21] DDRB_CS6_N_R [17] DDRB_CS5_N_R [20,21] DDRB_CS4_N_R [20,21] DDRB_CS3_N_R [19,21] DDRB_CS2_N_R [19,21] DDRB_CS1_N_R [19,21] DDRB_CS0_N_R [19,21]
DDRB_DRCOMP DDRCVOH_B
R1407 0/6/X
D DRB_RCVEN_IN D DRB_RCVEN_OUT
R140 0/6/X R142 0/6
R144 0/6 R146 0/6
R148 0/6 R150 0/6 R152 0/6 R154 0/6
R1402 0/6/X R1403 0/6/X
DDRB_CMDCLK0_N
DDRB_CMDCLK0
C1261
C1262
10P/6/X
10P/6/X
Title
Size Document Number Rev
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
MCH-DDRA AND DDRB
1
R1407: R249: R136: R1405:
R1405 24.9/6/1 R138 6.81/6/X
DDRCVOL_B
R249 0/6/X
R250 0/6
DDRB_CKE1 [19,20,21] DDRB_CKE0 [19,20,21]
DDRB_CMDCLK2 [20] DDRB_CMDCLK2_N [20]
DDRB_CMDCLK1 [19] DDRB_CMDCLK1_N [19] DDRB_CMDCLK0 [19] DDRB_CMDCLK0_N [19]
E7500 E7501
R1403: NOPOP
VREF_DDR_MCH [15,16,19,20,52]
DDRB_CMDCLK1_N
DDRB_CMDCLK1
C1263
C1264
10P/6/X
10P/6/X
GA-8IPP533
1
E7500 E7501
NOPOP0
0
NOPOP
47 1%
49.9 1% 25 1%NOPOP
6.81 1%R138:
NOPOP
VTT_DDR
R136 49.9/6/1
TO R249
C349 22P/6
C152 0.1U/6 C154 0.1U/6 C156 0.1U/6
DDRB_CMDCLK2_N
DDRB_CMDCLK2
C1266
C1265
10P/6/X
10P/6/X
12 58Tuesday, October 21, 2003
VTT_DDR
1.3
5
VCC1_2
D D
C C
VCCA1_2
C193
0.01U/6
VCCACPU
C199
0.01U/6
VCCAH1_2
C205
B B
0.01U/6
Low ESL
V_CORE
VCC1_2
54nH/8
A A
C209
C208
0.1U/6
150U/7343
U3F
B28 AA23
VCC1_2_1 VCC2_5_1
H20
VCC1_2_2
A10
VCC1_2_3
A14
VCC1_2_4
A18
VCC1_2_5
L22
VCC1_2_6
A22
VCC1_2_7
E10
VCC1_2_8
E13
VCC1_2_9
E16
VCC1_2_10
E19
VCC1_2_11
E22
VCC1_2_12
L20
VCC1_2_13
K13
VCC1_2_14
K15
VCC1_2_15
K17
VCC1_2_16
K19
VCC1_2_17
K21
VCC1_2_18
K23
VCC1_2_19
P14
VCC1_2_20
P18
VCC1_2_21
R17
VCC1_2_23
R19
VCC1_2_24
T14
VCC1_2_26
T16
VCC1_2_27
T18
VCC1_2_28
U17
VCC1_2_31
U19
VCC1_2_32
V16
VCC1_2_33
V18
VCC1_2_34
W15
VCC1_2_36
W17
VCC1_2_37
W19
VCC1_2_38
A26
VCC1_2_43
A30
VCC1_2_44
R15
VCC1_2_45
V14
VCC1_2_46
E26
VCC1_2_47
H19
VCC1_2_48
K11
VCC1_2_49
L12
VCC1_2_50
L14
VCC1_2_51
L16
VCC1_2_52
L18
VCC1_2_53
Y14
VCCA1_2_1
Y16
VCCA1_2_2
Y18
VCCA1_2_3
Y20
VCCA1_2_4
P20
VCCA1_2_5
T20
VCCA1_2_6
V20
VCCA1_2_7
U15
VCCA_CPU
P16
VCCAH1_2
AC5
VCC_CPU_1
AG3
VCC_CPU_2
AJ5
VCC_CPU_3
AF5
VCC_CPU_4
AH1
VCC_CPU_5
K7
VCC_CPU_6
F3
VCC_CPU_7
P5
VCC_CPU_8
R3
VCC_CPU_9
W7
VCC_CPU_10
H5
VCC_CPU_11
L5
VCC_CPU_12
U5
VCC_CPU_13
Y5
VCC_CPU_14
AE7
VCC_CPU_15
K9
VCC_CPU_16
AD1
VCC_CPU_17
D1
VCC_CPU_18
H1
VCC_CPU_19
M1
VCC_CPU_20
T1
VCC_CPU_21
Y1
VCC_CPU_22
A6
VCC_CPU_23
E7
VCC_CPU_24
AA10
VCC_CPU_25
AB11
VCC_CPU_26
AC10
VCC_CPU_27
C3
VCC_CPU_28
D5
VCC_CPU_29
VCCA1_2 VCCACPU VCCAH1_2
C211
C210
0.1U/6
0.1U/6
VCC2_5_2 VCC2_5_3 VCC2_5_4 VCC2_5_5 VCC2_5_6 VCC2_5_7 VCC2_5_8
VCC2_5_9 VCC2_5_10 VCC2_5_11 VCC2_5_12 VCC2_5_13 VCC2_5_14 VCC2_5_15 VCC2_5_16 VCC2_5_17 VCC2_5_18 VCC2_5_19 VCC2_5_20 VCC2_5_21 VCC2_5_22 VCC2_5_23 VCC2_5_24 VCC2_5_25 VCC2_5_26 VCC2_5_27 VCC2_5_28 VCC2_5_29 VCC2_5_30 VCC2_5_31 VCC2_5_32 VCC2_5_33 VCC2_5_34 VCC2_5_35 VCC2_5_36 VCC2_5_37 VCC2_5_38 VCC2_5_39 VCC2_5_40 VCC2_5_41 VCC2_5_42 VCC2_5_43 VCC2_5_44 VCC2_5_45 VCC2_5_46 VCC2_5_47 VCC2_5_48 VCC2_5_49 VCC2_5_50 VCC2_5_51 VCC2_5_52 VCC2_5_53 VCC2_5_54 VCC2_5_55 VCC2_5_56 VCC2_5_57 VCC2_5_58 VCC2_5_59 VCC2_5_60 VCC2_5_61 VCC2_5_62 VCC2_5_63 VCC2_5_64
Plumas MCH Power
VCC2_5_65 VCC2_5_66 VCC2_5_67 VCC2_5_68 VCC2_5_69 VCC2_5_70 VCC2_5_71 VCC2_5_72 VCC2_5_73 VCC2_5_74 VCC2_5_75 VCC2_5_76 VCC2_5_77
VCC_CPU_30 VCC_CPU_31 VCC_CPU_32 VCC_CPU_33 VCC_CPU_34 VCC_CPU_35 VCC_CPU_36 VCC_CPU_37 VCC_CPU_38 VCC_CPU_39
VCC1_2
R169
1/6/1
VCC2_5
AA27 AC13 AC15 AC17 AC19 AD12 AD14 AD16 AD18 AD20 AD25 AD29 AD33 AE10 AE30 AF33 AG13 AG19 AG22 AJ11 AJ14 AJ17 AJ20 AJ23 AK10 AK33 AK8 AL1 AL15 AL24 AN10 AN14 AN18 AN22 AN26 AN4 AN7 H33 L29 M33 P24 P29 T24 T33 U23 U29 V24 W23 Y24 Y29 Y33 AB24 AC21 AC23 AD22 AD24 AF23 AG28 AJ26 AJ29 AM32 AN30 B32 D33 E29 G27 H29 K24 L23 L26 M24 N23 R23 AB31 K31 T31
L10 M11 N10 P11 R10 T11 U10 V11 W10 Y11
U3
L6
0.1UH/8 C212
150U/7343
Low ESL
5
AK9
AM8
AC8
G7 D30 AF8 AA9
F28
AG6
AH7 AH4 AL4
AJ2 AK3 AD6 AK6 AL7
AM5
AF2 AD3
AG1
AK1
G4 M6
M3 M9
W4 W2
AA3 AA6
J19
J20
G19
J23 AB5
AE4 AC2
AG9
C28 B27 AB4 AB7 AD9
AA11 AB10 AC11 AD10
AN9
M10
M5 N11 P10 R11 T10
4
U3E
Y17
Y19
Y23
Y26
VSS1 VSS2
VSS298
VSS299
VSS300
VSS3 VSS4 VSS5 VSS6 VSS7
J6
VSS8
V3
VSS9 VSS10 VSS11 VSS12 VSS13 VSS14 VSS15 VSS16 VSS17 VSS18 VSS19 VSS20 VSS21 VSS22 VSS23 VSS24
U9
VSS25
E2
VSS26
H2
VSS27
K4
VSS28
J3
VSS29
K8
VSS30
L8
VSS31 VSS32 VSS33
P2
VSS34 VSS35 VSS36
P8
VSS37
N9
VSS38
U2
VSS39
R6
VSS40
T4
VSS41
V6
VSS42 VSS43 VSS44
Y2
VSS45 VSS46 VSS47
Y8
VSS48 VSS49 VSS50 VSS51
E5
VSS52 VSS53 VSS54
D4
VSS55 VSS56 VSS57 VSS58
L9
VSS59 VSS60 VSS61 VSS62 VSS63 VSS64 VSS65 VSS66 VSS67 VSS68 VSS69 VSS70 VSS71 VSS72 VSS73 VSS74 VSS75
VSS76
VSS77
VSS78
U11
V10
W11
Y10B2J17
VCC1_2
R170
1/6/1
4
W33
Y15
VSS296
VSS297
VSS79
VSS80
W28
W31
VSS293
VSS294
VSS295
VSS81
VSS82
VSS83
K10
L11
L7
0.1UH/8
W20
W24
VSS292
VSS84
L13
L15
W18
VSS291
VSS85
L17
V23
V27
V30V9W1
W14
W16
VSS284
VSS285
VSS286
VSS287
VSS288
VSS289
VSS290
Plumas533 MCH VSS Pin
VSS86
VSS87
VSS88
VSS89
VSS90
VSS91
VSS92
L19
L21
R16
AC29
AJ10
D25
A11
C213 150U/7343
V17
V19
VSS281
VSS282
VSS283
VSS93
VSS94
VSS95
A15
A19
U24
U32U8V15
VSS277
VSS278
VSS279
VSS280
VSS96
VSS97
VSS98
VSS99
A23
A29A3A31A7AA24
U20
SBC17
0.1U/6
3
L33
M23
M27
M30
N24
N28
N31
P15
P17
P19
P23
P32R1R14
R18
R20
R24
R27
R30
R33R9T15
T17
T19
T23
T28
AJ8
U14
U16
U18
VSS246
VSS247
VSS248
VSS249
VSS250
VSS251
VSS252
VSS253
VSS254
VSS255
VSS256
VSS257
VSS258
VSS259
VSS260
VSS261
VSS262
VSS263
VSS264
VSS265
VSS266
VSS267
VSS268
VSS269
VSS270
VSS271
VSS272
VSS273
VSS274
VSS275
VSS276
VSS100
VSS101
VSS102
VSS103
VSS104
VSS105
VSS106
VSS107
VSS108
VSS109
VSS110
VSS111
VSS112
VSS113
VSS114
VSS115
VSS116
VSS117
VSS118
VSS119
VSS120
VSS121
VSS122
VSS123
VSS124
VSS125
VSS126
VSS127
VSS128
VSS129
VSS130
AA30
AB23
AB28
Y32
AC1
AC12
AC14
AC16
AC18
AC20
AC22
AC24
AC26
AC32
AC33
AD11
AD13
AD15
AD17
AD19
AD21
AD23
AD26
AD30
AE29
AE9
AF10
AF11
AF14
V_CORE
SBC22
SBC21
SBC20
SBC19
SBC18
0.1U/6
0.1U/6
0.01U/6
0.01U/6
0.1U/6
Backside caps near center of MCH
3
L24
L32
VSS245
VSS131
AF17
AF20
SBC23
0.1U/6
VSS242
VSS243
VSS244
VSS132
VSS133
VSS134
AF26
AF29
K22
K28N5L1
VSS241
VSS135
AF32
AG16
SBC24
0.1U/6
K18
K20
VSS238
VSS239
VSS240
VSS136
VSS137
VSS138
AG25
AG31
K14
K16
VSS237
VSS139
AH12
AH15
2
VSS235
VSS236
VSS140
VSS141
AH18
AH21
SBC25
0.01U/6
2
J27
J30J9K12
VSS232
VSS233
VSS234
VSS142
VSS143
VSS144
AH24
AH27
VCC2_5
J21
J24
VSS231
VSS145
AH30
AJ32
SBC26
0.01U/6
J15
J18
VSS228
VSS229
VSS230
VSS146
VSS147
VSS148
AJ33
AK13
1
H8
J12
VSS226
VSS227
VSS225 VSS224 VSS223 VSS222 VSS221 VSS220 VSS219 VSS218 VSS217 VSS216 VSS215 VSS214 VSS213 VSS212 VSS211 VSS210 VSS209 VSS208 VSS207 VSS206 VSS205 VSS204 VSS203 VSS202 VSS201 VSS200 VSS199 VSS198 VSS197 VSS196 VSS195 VSS194 VSS193 VSS192 VSS191 VSS190 VSS189 VSS188 VSS187 VSS186 VSS185 VSS184 VSS183 VSS182 VSS181 VSS180 VSS179 VSS178 VSS177 VSS176 VSS175 VSS174 VSS173 VSS172 VSS171 VSS170 VSS169 VSS168 VSS167 VSS166 VSS165 VSS164 VSS163 VSS162 VSS161 VSS160 VSS159 VSS158 VSS157 VSS156 VSS155 VSS154 VSS153 VSS152 VSS151
VSS149
VSS150
U3
AK16
AK22
SBC27
0.1U/6L5
Title
Size Document Number Rev
Date: Sheet of
H32 H26 H22 H16 H13 H10 G8 G33 G31 G28 G23 G20 G17 G14 G11 G1 F9 F6 F30 F27 F21 F18 F15 F12 E32 E25 D8 D31 D23 D20 D17 D14 D11 C9 C6 C33 C30 C27 C21 C15 C12 C1 B7 B4 B29 B26 B22 B19 B16 B13 B10 AN6 AN31 AN3 AN27 AN23 AN19 AN15 AN11 AM29 AM26 AM23 AM20 AM17 AM14 AM11 AL33 AL30 AL27 AL21 AL18 AL12 AK31 AK28 AK25
VCC2_5
C167 0.1U/6
C169 0.1U/6
C171 0.1U/6
C173 0.1U/6
C175 0.1U/6
C177 0.1U/6
C179 0.1U/6
C181 0.1U/6
C183 0.1U/6
C185 0.1U/6
C187 0.01U/6
C189 0.01U/6
C191 0.01U/6
C192 0.01U/6
Place caps near DDR interface
VCC1_2
SBC31
0.01U/6
SBC28
0.1U/6
C194 0.01U/6
C196 0.01U/6
C198 0.01U/6
C201 0.01U/6
C203 0.01U/6
SBC29
SBC30
0.1U/6
0.01U/6
GIGA-BYTE TECHNOLOGY CO., LTD.
MCH POWER AND GND
GA-8IPP533
1
V_CORE
C166 0.1U/6
C168 0.1U/6
C170 0.1U/6
C172 0.1U/6
C174 0.1U/6
C176 0.1U/6
C178 0.1U/6
C180 0.01U/6
C182 0.01U/6
C184 0.01U/6
C186 0.01U/6
C188 0.01U/6
C190 0.01U/6
C195 0.1U/6
C197 0.1U/6
C200 0.1U/6
C202 0.1U/6
C204 0.01U/6
C206 0.01U/6
C207 0.01U/6
VCC1_2
C1540 10U/1206
13 58Tuesday, October 21, 2003
H1
1 2
MRN H1X2 H2
1 2
MRN H1X2
Near FSB interfaceNear HUB interface
1.3
5
4
3
2
1
DDR Channel A Series Resistors
Place near DIMM A-1
5
R171 10/6/1 R172 10/6/1
RN2
1 2 3 4 5 6 7 8
8P4R-10
RN4
1 2 3 4 5 6 7 8
8P4R-10
RN6
1 2 3 4 5 6 7 8
8P4R-10
RN8
1 2 3 4 5 6 7 8
8P4R-10
RN10
1 2 3 4 5 6 7 8
8P4R-10
RN12
1 2 3 4 5 6 7 8
8P4R-10
RN14
1 2 3 4 5 6 7 8
8P4R-10
RN16
1 2 3 4 5 6 7 8
8P4R-10
RN18
1 2 3 4 5 6 7 8
8P4R-10
RN22
1 2 3 4 5 6 7 8
8P4R-10
RN20
1 2 3 4 5 6 7 8
8P4R-10
D D
C C
B B
A A
DDRA_DQ0[12] DDRA_DQ4[12]
DDRA_DQ3[12] DDRA_DQ3_R [15,16,17] DDRA_DQ6[12] DQS9_A[12] DQS9_A_R [15,16,17] DDRA_DQ7[12] DDRA_DQ7_R [15,16,17]
DDRA_DQ1[12] DDRA_DQ1_R [15,16,17] DDRA_DQ5[12] DDRA_DQ5_R [15,16,17] DDRA_DQ2[12] DDRA_DQ2_R [15,16,17] DQS0_A[12] DQS0_A_R [15,16,17]
DDRA_DQ13[12] DQS10_A[12] DDRA_DQ14[12] DDRA_DQ15[12]
DDRA_DQ8[12] DDRA_DQ12[12]
DQS1_A[12]
DDRA_DQ10[12] DDRA_DQ10_R [15,16,17] DDRA_DQ11[12] DDRA_DQ20[12] DDRA_DQ16[12]
DQS11_A[12] DDRA_DQ22[12] DDRA_DQ19[12] DDRA_DQ23[12]
DDRA_DQ17[12] DQS2_A[12] DDRA_DQ21[12] DDRA_DQ18[12]
DQS3_A[12] DQS12_A[12] DDRA_DQ30[12] DDRA_DQ30_R [15,16,17] DDRA_DQ26[12]
DDRA_DQ24[12] DDRA_DQ28[12] DDRA_DQ25[12] DDRA_DQ25_R [15,16,17] DDRA_DQ29[12]
DDRA_DQ32[12] DDRA_DQ36[12] DDRA_DQ37[12] DDRA_DQ33[12]
CB2_A[12] CB6_A[12] CB6_A_R [15,16,17] CB3_A[12] CB3_A_R [15,16,17] CB7_A[12]
DDRA_DQ0_R [15,16,17] DDRA_DQ4_R [15,16,17]
DDRA_DQ6_R [15,16,17]
DDRA_DQ13_R [15,16,17] DQS10_A_R [15,16,17] DDRA_DQ14_R [15,16,17] DDRA_DQ15_R [15,16,17]
DDRA_DQ8_R [15,16,17] DDRA_DQ12_R [15,16,17] DDRA_DQ9_R [15,16,17] DQS1_A_R [15,16,17]
DDRA_DQ11_R [15,16,17] DDRA_DQ20_R [15,16,17] DDRA_DQ16_R [15,16,17]
DQS11_A_R [15,16,17] DDRA_DQ22_R [15,16,17] DDRA_DQ19_R [15,16,17] DDRA_DQ23_R [15,16,17]
DDRA_DQ17_R [15,16,17] DQS2_A_R [15,16,17] DDRA_DQ21_R [15,16,17] DDRA_DQ18_R [15,16,17]
DQS3_A_R [15,16,17] DQS12_A_R [15,16,17]
DDRA_DQ26_R [15,16,17]
DDRA_DQ24_R [15,16,17] DDRA_DQ28_R [15,16,17]
DDRA_DQ29_R [15,16,17]
DDRA_DQ32_R [15,16,17] DDRA_DQ36_R [15,16,17] DDRA_DQ37_R [15,16,17] DDRA_DQ33_R [15,16,17]
CB2_A_R [15,16,17]
CB7_A_R [15,16,17]
VCC2_5 VCC2_5 VCC2_5
C1515 22U/12
C1521 22U/12
1
C216 0.1U/6
C219 0.1U/6
C222 0.1U/6
C225 0.1U/6
C228 0.01U/6
C1516 22U/12
C1522 22U/12
14 58Tuesday, October 21, 2003
1.3
RN1
3
1 2 3 4 5 6 7 8
8P4R-10
RN3
1 2 3 4 5 6 7 8
8P4R-10
RN5
1 2 3 4 5 6 7 8
8P4R-10
RN7
1 2 3 4 5 6 7 8
8P4R-10
RN9
1 2 3 4 5 6 7 8
8P4R-10
RN11
1 2 3 4 5 6 7 8
8P4R-10
RN13
1 2 3 4 5 6 7 8
8P4R-10
RN15
1 2 3 4 5 6 7 8
8P4R-10
RN17
1 2 3 4 5 6 7 8
8P4R-10
RN19
1 2 3 4 5 6 7 8
8P4R-10
RN21
1 2 3 4 5 6 7 8
8P4R-10
DQS4_A_R [15,16,17] DDRA_DQ34_R [15,16,17] DQS13_A_R [15,16,17]
DDRA_DQ42_R [15,16,17] DDRA_DQ46_R [15,16,17] DDRA_DQ43_R [15,16,17] DDRA_DQ47_R [15,16,17]
DQS14_A_R [15,16,17] DQS5_A_R [15,16,17]
DDRA_DQ48_R [15,16,17] DDRA_DQ52_R [15,16,17] DDRA_DQ49_R [15,16,17]DDRA_DQ9[12] DDRA_DQ53_R [15,16,17]
DDRA_DQ50_R [15,16,17] DDRA_DQ51_R [15,16,17]
DDRA_DQ61_R [15,16,17]
DQS15_A_R [15,16,17] DDRA_DQ54_R [15,16,17] DQS6_A_R [15,16,17] DDRA_DQ55_R [15,16,17]
DDRA_DQ56_R [15,16,17] DQS16_A_R [15,16,17] DDRA_DQ57_R [15,16,17] DDRA_DQ62_R [15,16,17]
DDRA_DQ58_R [15,16,17] DDRA_DQ59_R [15,16,17]
DDRA_DQ39_R [15,16,17] DDRA_DQ40_R [15,16,17]
DDRA_DQ44_R [15,16,17]
CB0_A_R [15,16,17] CB1_A_R [15,16,17] DQS8_A_R [15,16,17] DQS17_A_R [15,16,17]
DDRA_DQ31_R [15,16,17] CB5_A_R [15,16,17]
2
DQS4_A[12] DDRA_DQ34[12] DQS13_A[12] DDRA_DQ38[12] DDRA_DQ38_R [15,16,17]
DDRA_DQ42[12] DDRA_DQ46[12] DDRA_DQ43[12] DDRA_DQ47[12]
DDRA_DQ41[12] DDRA_DQ41_R [15,16,17] DDRA_DQ45[12] DDRA_DQ45_R [15,16,17] DQS14_A[12] DQS5_A[12]
DDRA_DQ48[12] DDRA_DQ52[12] DDRA_DQ49[12] DDRA_DQ53[12]
DDRA_DQ50[12] DDRA_DQ51[12] DDRA_DQ60[12] DDRA_DQ60_R [15,16,17] DDRA_DQ61[12]
DQS15_A[12] DDRA_DQ54[12] DQS6_A[12] DDRA_DQ55[12]
DDRA_DQ56[12] DQS16_A[12] DDRA_DQ57[12] DDRA_DQ62[12]
DQS7_A[12] DQS7_A_R [15,16,17] DDRA_DQ63[12] DDRA_DQ63_R [15,16,17] DDRA_DQ58[12] DDRA_DQ59[12]
DDRA_DQ39[12] DDRA_DQ35[12] DDRA_DQ35_R [15,16,17] DDRA_DQ40[12] DDRA_DQ44[12]
CB0_A[12] CB1_A[12] DQS8_A[12] DQS17_A[12]
DDRA_DQ27[12] DDRA_DQ27_R [15,16,17] DDRA_DQ31[12] CB4_A[12] CB4_A_R [15,16,17] CB5_A[12]
4
C214 0.1U/6
C217 0.1U/6
C220 0.1U/6
C223 0.1U/6
C226 0.01U/6
C229 0.01U/6
0.1UF Backside or Frontside Caps 6 Caps between each pair of DIMM
Place 150uF caps arrounding A DIMM
VCC2_5
C1511 22U/12
VCC2_5
C1517 22U/12
Title
Size Document Number Rev
Date: Sheet of
C215 0.1U/6
C218 0.1U/6
C221 0.1U/6
C224 0.1U/6
C227 0.01U/6
C230 0.01U/6 C231 0.01U/6
VCC2_5
EC21 150U/S
EC22 150U/S
EC23 150U/S
EC24 150U/S
EC25 150U/S
C1512 22U/12
C1518 22U/12
C1513 22U/12
C1519 22U/12
C1514 22U/12
C1520 22U/12
GIGA-BYTE TECHNOLOGY CO., LTD.
DDR CHNNEL A SERIES RESISTORS
GA-8IPP533
5
4
3
2
1
DIMM A-1 DIMM A-2
J1
R190
8.2k/6
2 4 6 8
5 97 94 95 98 99 12 13 19 20 14
107 105 106 109 110
23 24 28 31 25
119 114 117 121 123
33 35 39 40 36
129 126 127 131 133
53 55 57 60 56
149 146 147 150 151
61 64 68 69 67
159 153 155 161 162
72 73 79 80 78
169 165 166 170 171
83 84 87 88 86
177 174 175 178 179
44 45 49 51 47
140 134 135 142 144
DDR DIMM_1
DQ0 DQ1 DQ2 DQ3 DQS0 DQS9 DQ4 DQ5 DQ6 DQ7 DQ8 DQ9 DQ10 DQ11 DQS1 DQS10 DQ12 DQ13 DQ14 DQ15 DQ16 DQ17 DQ18 DQ19 DQS2 DQS11 DQ20 DQ21 DQ22 DQ23 DQ24 DQ25 DQ26 DQ27 DQS3 DQS12 DQ28 DQ29 DQ30 DQ31 DQ32 DQ33 DQ34 DQ35 DQS4 DQS13 DQ36 DQ37 DQ38 DQ39 DQ40 DQ41 DQ42 DQ43 DQS5 DQS14 DQ44 DQ45 DQ46 DQ47 DQ48 DQ49 DQ50 DQ51 DQS6 DQS15 DQ52 DQ53 DQ54 DQ55 DQ56 DQ57 DQ58 DQ59 DQS7 DQS16 DQ60 DQ61 DQ62 DQ63 CB0 CB1 CB2 CB3 DQS8 DQS17 CB4 CB5 CB6 CB7
VREF VSS1
VSS2 VSS3 VSS4 VSS5 VSS6 VSS7 VSS8
VSS9 VSS10 VSS11 VSS12 VSS13 VSS14 VSS15 VSS16 VSS17 VSS18 VSS19 VSS20 VSS21
VDDID
VDDSPD
VDD1
VDD2
VDD3
VDD4
VDD5
VDD6
VDD7
VDD8
VDD9
VDDQ1 VDDQ2 VDDQ3 VDDQ4 VDDQ5 VDDQ6 VDDQ7 VDDQ8
VDDQ9 VDDQ10 VDDQ11 VDDQ12 VDDQ13 VDDQ14 VDDQ15 VDDQ16
MA10 MA11 MA12
WE_N CAS_N RAS_N
NC_FETEN
NC_S2_N NC_S3_N
MA13 RESET
DU_CK1
DU_CK1_N
DU_CK2
DU_CK2_N
CKE0 CKE1
CK0_N
S0_N S1_N
DDRA_DQ0_R[14,16,17] DDRA_DQ1_R[14,16,17] DDRA_DQ2_R[14,16,17] DDRA_DQ3_R[14,16,17] DQS0_A_R[14,16,17]
D D
C C
B B
A A
DQS9_A_R[14,16,17] DDRA_DQ4_R[14,16,17] DDRA_DQ5_R[14,16,17] DDRA_DQ6_R[14,16,17] DDRA_DQ7_R[14,16,17] DDRA_DQ8_R[14,16,17] DDRA_DQ9_R[14,16,17] DDRA_DQ10_R[14,16,17] DDRA_DQ11_R[14,16,17] DQS1_A_R[14,16,17] DQS10_A_R[14,16,17] DDRA_DQ12_R[14,16,17] DDRA_DQ13_R[14,16,17] DDRA_DQ14_R[14,16,17] DDRA_DQ15_R[14,16,17] DDRA_DQ16_R[14,16,17] DDRA_DQ17_R[14,16,17] DDRA_DQ18_R[14,16,17] DDRA_DQ19_R[14,16,17] DQS2_A_R[14,16,17] DQS11_A_R[14,16,17] DDRA_DQ20_R[14,16,17] DDRA_DQ21_R[14,16,17] DDRA_DQ22_R[14,16,17] DDRA_DQ23_R[14,16,17] DDRA_DQ24_R[14,16,17] DDRA_DQ25_R[14,16,17] DDRA_DQ26_R[14,16,17] DDRA_DQ27_R[14,16,17] DQS3_A_R[14,16,17] DQS12_A_R[14,16,17] DDRA_DQ28_R[14,16,17] DDRA_DQ29_R[14,16,17] DDRA_DQ30_R[14,16,17] DDRA_DQ31_R[14,16,17] DDRA_DQ32_R[14,16,17] DDRA_DQ33_R[14,16,17] DDRA_DQ34_R[14,16,17] DDRA_DQ35_R[14,16,17] DQS4_A_R[14,16,17] DQS13_A_R[14,16,17] DDRA_DQ36_R[14,16,17] DDRA_DQ37_R[14,16,17] DDRA_DQ38_R[14,16,17] DDRA_DQ39_R[14,16,17] DDRA_DQ40_R[14,16,17] DDRA_DQ41_R[14,16,17] DDRA_DQ42_R[14,16,17] DDRA_DQ43_R[14,16,17] DQS5_A_R[14,16,17] DQS14_A_R[14,16,17] DDRA_DQ44_R[14,16,17] DDRA_DQ45_R[14,16,17] DDRA_DQ46_R[14,16,17] DDRA_DQ47_R[14,16,17] DDRA_DQ48_R[14,16,17] DDRA_DQ49_R[14,16,17] DDRA_DQ50_R[14,16,17] DDRA_DQ51_R[14,16,17] DQS6_A_R[14,16,17] DQS15_A_R[14,16,17] DDRA_DQ52_R[14,16,17] DDRA_DQ53_R[14,16,17] DDRA_DQ54_R[14,16,17] DDRA_DQ55_R[14,16,17] DDRA_DQ56_R[14,16,17] DDRA_DQ57_R[14,16,17] DDRA_DQ58_R[14,16,17] DDRA_DQ59_R[14,16,17] DQS7_A_R[14,16,17] DQS16_A_R[14,16,17] DDRA_DQ60_R[14,16,17] DDRA_DQ61_R[14,16,17] DDRA_DQ62_R[14,16,17] DDRA_DQ63_R[14,16,17] CB0_A_R[14,16,17] CB1_A_R[14,16,17] CB2_A_R[14,16,17] CB3_A_R[14,16,17] DQS8_A_R[14,16,17] DQS17_A_R[14,16,17] CB4_A_R[14,16,17] CB5_A_R[14,16,17] CB6_A_R[14,16,17] CB7_A_R[14,16,17]
DIMM_A1_SA0 DIMM_A1_SA1 DIMM_A1_SA2
000
R188
8.2k/6
5
R189
8.2k/6
VSS
MA0 MA1 MA2 MA3 MA4 MA5 MA6 MA7 MA8 MA9
NC3
NC1 NC2
NC4 NC5
BA0 BA1 BA2 CK0
SDA SCL SA0 SA1 SA2
VREF_DDR_DIMM
1 50 3 11 18 26 34 42 58 66 74 81 89 176 160 152 145 139 132 124 116 100 93 82 184 7 38 46 70 85 168 148 120 108 15 22 30 54 62 77 180 172 164 156 143 136 128 112 104 96 48 43 41 130 37 32 125 29 122 27 141 118 115 103 63 65 154 9 90 173 102 101 71 163 167 10 16 17 75 76 21 111 59 52 113 137 138 91
R1766 47/6
92 181 182 183 157 158
4
C1641
0.01U/6
VCC3 VCC2_5
DDRA_MA0_R [12,16,17] DDRA_MA1_R [12,16,17] DDRA_MA2_R [12,16,17] DDRA_MA3_R [12,16,17] DDRA_MA4_R [12,16,17] DDRA_MA5_R [12,16,17] DDRA_MA6_R [12,16,17] DDRA_MA7_R [12,16,17] DDRA_MA8_R [12,16,17] DDRA_MA9_R [12,16,17] DDRA_MA10_R [12,16,17] DDRA_MA11_R [12,16,17] DDRA_MA12_R [12,16,17]
DDRA_WE_N_R DDRA_CAS_N_R DDRA_RAS_N_R
PCIRST2_5_N
R173 0/6
R175 0/6
R177 0/6/X
DIMM_A1_SA0 DIMM_A1_SA1 DIMM_A1_SA2 DDRA_CS0_N_R DDRA_CS1_N_R
VREF_DDR_DIMM [12,16,19,20,52]
C232
0.1U/6
VDD_ID [16,19,20,49]
DDRA_WE_N_R [12,16,17] DDRA_CAS_N_R [12,16,17] DDRA_RAS_N_R [12,16,17]
PCIRST2_5_N [11,16,19,20,36]
DDRA_CKE0
DDRA_CKE1 DDRA_CKE1
DDRA_BA0_R DDRA_BA1_R
DDRA_CMDCLK0 D DRA_CMDCLK0_N ICH3_SMBDATA ICH3_SMBCLK
DDRA_CS0_N_R [12,17] DDRA_CS1_N_R [12,17]
DDRA_CKE0 [12,16,17]
DDRA_CKE1 [12,16,17]
DDRA_BA0_R [12,16,17] DDRA_BA1_R [12,16,17]
DDRA_CMDCLK0 [12] D DRA_CMDCLK0_N [12]
ICH3_SMBDATA [11,16,19,20,24,37,46] ICH3_SMBCLK [11,16,19,20,24,37,46]
DIMM_A2_SA0 DIMM_A2_SA1 DIMM_A2_SA2
001
3
R185
8.2k/6
VCC3
R181
8.2k/6
R186
8.2k/6
DDRA_DQ0_R DDRA_DQ1_R DDRA_DQ2_R DDRA_DQ3_R DQS0_A_R DQS9_A_R DDRA_DQ4_R DDRA_DQ5_R DDRA_DQ6_R DDRA_DQ7_R DDRA_DQ8_R DDRA_DQ9_R DDRA_DQ10_R DDRA_DQ11_R DQS1_A_R DQS10_A_R DDRA_DQ12_R DDRA_DQ13_R DDRA_DQ14_R DDRA_DQ15_R DDRA_DQ16_R DDRA_DQ17_R DDRA_DQ18_R DDRA_DQ19_R DQS2_A_R DQS11_A_R DDRA_DQ20_R DDRA_DQ21_R DDRA_DQ22_R DDRA_DQ23_R DDRA_DQ24_R DDRA_DQ25_R DDRA_DQ26_R DDRA_DQ27_R DQS3_A_R DQS12_A_R DDRA_DQ28_R DDRA_DQ29_R DDRA_DQ30_R DDRA_DQ31_R DDRA_DQ32_R DDRA_DQ33_R DDRA_DQ34_R DDRA_DQ35_R DQS4_A_R DQS13_A_R DDRA_DQ36_R DDRA_DQ37_R DDRA_DQ38_R DDRA_DQ39_R DDRA_DQ40_R DDRA_DQ41_R DDRA_DQ42_R DDRA_DQ43_R DQS5_A_R DQS14_A_R DDRA_DQ44_R DDRA_DQ45_R DDRA_DQ46_R DDRA_DQ47_R DDRA_DQ48_R DDRA_DQ49_R DDRA_DQ50_R DDRA_DQ51_R DQS6_A_R DQS15_A_R DDRA_DQ52_R DDRA_DQ53_R DDRA_DQ54_R DDRA_DQ55_R DDRA_DQ56_R DDRA_DQ57_R DDRA_DQ58_R DDRA_DQ59_R DQS7_A_R DQS16_A_R DDRA_DQ60_R DDRA_DQ61_R DDRA_DQ62_R DDRA_DQ63_R CB0_A_R CB1_A_R CB2_A_R CB3_A_R DQS8_A_R DQS17_A_R CB4_A_R CB5_A_R CB6_A_R CB7_A_R
2 4 6 8
5 97 94 95 98 99 12 13 19 20 14
107 105 106 109 110
23 24 28 31 25
119 114 117 121 123
33 35 39 40 36
129 126 127 131 133
53 55 57 60 56
149 146 147 150 151
61 64 68 69 67
159 153 155 161 162
72 73 79 80 78
169 165 166 170 171
83 84 87 88 86
177 174 175 178 179
44 45 49 51 47
140 134 135 142 144
DDR DIMM_1
J2
DQ0 DQ1 DQ2 DQ3 DQS0 DQS9 DQ4 DQ5 DQ6 DQ7 DQ8 DQ9 DQ10 DQ11 DQS1 DQS10 DQ12 DQ13 DQ14 DQ15 DQ16 DQ17 DQ18 DQ19 DQS2 DQS11 DQ20 DQ21 DQ22 DQ23 DQ24 DQ25 DQ26 DQ27 DQS3 DQS12 DQ28 DQ29 DQ30 DQ31 DQ32 DQ33 DQ34 DQ35 DQS4 DQS13 DQ36 DQ37 DQ38 DQ39 DQ40 DQ41 DQ42 DQ43 DQS5 DQS14 DQ44 DQ45 DQ46 DQ47 DQ48 DQ49 DQ50 DQ51 DQS6 DQS15 DQ52 DQ53 DQ54 DQ55 DQ56 DQ57 DQ58 DQ59 DQS7 DQS16 DQ60 DQ61 DQ62 DQ63 CB0 CB1 CB2 CB3 DQS8 DQS17 CB4 CB5 CB6 CB7
VSS10 VSS11 VSS12 VSS13 VSS14 VSS15 VSS16 VSS17 VSS18 VSS19 VSS20 VSS21
VDDID
VDDSPD
VDDQ1 VDDQ2 VDDQ3 VDDQ4 VDDQ5 VDDQ6 VDDQ7 VDDQ8
VDDQ9 VDDQ10 VDDQ11 VDDQ12 VDDQ13 VDDQ14 VDDQ15 VDDQ16
MA10 MA11 MA12
WE_N CAS_N RAS_N
NC_FETEN
NC_S2_N NC_S3_N
MA13 RESET
DU_CK1
DU_CK1_N
DU_CK2
DU_CK2_N
CK0_N
2
VREF_DDR_DIMM
VREF
VSS VSS1 VSS2 VSS3 VSS4 VSS5 VSS6 VSS7 VSS8 VSS9
VDD1 VDD2 VDD3 VDD4 VDD5 VDD6 VDD7 VDD8 VDD9
MA0 MA1 MA2 MA3 MA4 MA5 MA6 MA7 MA8 MA9
NC3
NC1
NC2
NC4
NC5
CKE0 CKE1
BA0
BA1
BA2
CK0
SDA
SCL
SA0
SA1
SA2 S0_N S1_N
1 50 3 11 18 26 34 42 58 66 74 81 89 176 160 152 145 139 132 124 116 100 93 82 184 7 38 46 70 85 168 148 120 108 15 22 30 54 62 77 180 172 164 156 143 136 128 112 104 96 48 43 41 130 37 32 125 29 122 27 141 118 115 103 63 65 154 9 90 173 102 101 71 163 167 10 16 17 75 76 21 111 59 52 113 137 138
R1767 47/6
91 92 181 182 183 157 158
C1642
0.01U/6
VDD_ID
VCC3 VCC2_5
DDRA_MA0_R DDRA_MA1_R DDRA_MA2_R DDRA_MA3_R DDRA_MA4_R DDRA_MA5_R DDRA_MA6_R DDRA_MA7_R DDRA_MA8_R DDRA_MA9_R DDRA_MA10_R DDRA_MA11_R DDRA_MA12_R
DDRA_WE_N_R DDRA_CAS_N_R DDRA_RAS_N_R
PCIRST2_5_N
R174 0/6
R176 0/6
R178 0/6/X
DDRA_BA0_R DDRA_BA1_R
DIMM_A2_SA0 DIMM_A2_SA1 DIMM_A2_SA2 DDRA_CS2_N_R DDRA_CS3_N_R
Title
Size Document Number Rev
GIGA-BYTE TECHNOLOGY CO., LTD.
DDR DIMM A1 AND A2
Date: Sheet of
C233
0.1U/6
VREF_DDR_DIMM
DDRA_CMDCLK1 D DRA_CMDCLK1_N ICH3_SMBDATA ICH3_SMBCLK
DDRA_CS2_N_R [12,21] DDRA_CS3_N_R [12,17]
GA-8IPP533
C1647
10U/12
C1648
10U/12
C1649
10U/12
DDRA_CKE0
DDRA_CMDCLK1 [12]
D DRA_CMDCLK1_N [12] ICH3_SMBDATA [11,16,19,20,24,37,46] ICH3_SMBCLK [11,16,19,20,24,37,46]
15 58Tuesday, October 21, 2003
1
C1650
10U/12
1.3
5
4
3
2
1
DIMM A-3
J3
DDRA_DQ0_R[14,15,17] DDRA_DQ1_R[14,15,17] DDRA_DQ2_R[14,15,17]
D D
C C
B B
A A
5
DDRA_DQ3_R[14,15,17] DQS0_A_R[14,15,17] DQS9_A_R[14,15,17] DDRA_DQ4_R[14,15,17] DDRA_DQ5_R[14,15,17] DDRA_DQ6_R[14,15,17] DDRA_DQ7_R[14,15,17] DDRA_DQ8_R[14,15,17] DDRA_DQ9_R[14,15,17] DDRA_DQ10_R[14,15,17] DDRA_DQ11_R[14,15,17] DQS1_A_R[14,15,17] DQS10_A_R[14,15,17] DDRA_DQ12_R[14,15,17] DDRA_DQ13_R[14,15,17] DDRA_DQ14_R[14,15,17] DDRA_DQ15_R[14,15,17] DDRA_DQ16_R[14,15,17] DDRA_DQ17_R[14,15,17] DDRA_DQ18_R[14,15,17] DDRA_DQ19_R[14,15,17] DQS2_A_R[14,15,17] DQS11_A_R[14,15,17] DDRA_DQ20_R[14,15,17] DDRA_DQ21_R[14,15,17] DDRA_DQ22_R[14,15,17] DDRA_DQ23_R[14,15,17] DDRA_DQ24_R[14,15,17] DDRA_DQ25_R[14,15,17] DDRA_DQ26_R[14,15,17] DDRA_DQ27_R[14,15,17] DQS3_A_R[14,15,17] DQS12_A_R[14,15,17] DDRA_DQ28_R[14,15,17] DDRA_DQ29_R[14,15,17] DDRA_DQ30_R[14,15,17] DDRA_DQ31_R[14,15,17] DDRA_DQ32_R[14,15,17] DDRA_DQ33_R[14,15,17] DDRA_DQ34_R[14,15,17] DDRA_DQ35_R[14,15,17] DQS4_A_R[14,15,17] DQS13_A_R[14,15,17] DDRA_DQ36_R[14,15,17] DDRA_DQ37_R[14,15,17] DDRA_DQ38_R[14,15,17] DDRA_DQ39_R[14,15,17] DDRA_DQ40_R[14,15,17] DDRA_DQ41_R[14,15,17] DDRA_DQ42_R[14,15,17] DDRA_DQ43_R[14,15,17] DQS5_A_R[14,15,17] DQS14_A_R[14,15,17] DDRA_DQ44_R[14,15,17] DDRA_DQ45_R[14,15,17] DDRA_DQ46_R[14,15,17] DDRA_DQ47_R[14,15,17] DDRA_DQ48_R[14,15,17] DDRA_DQ49_R[14,15,17] DDRA_DQ50_R[14,15,17] DDRA_DQ51_R[14,15,17] DQS6_A_R[14,15,17] DQS15_A_R[14,15,17] DDRA_DQ52_R[14,15,17] DDRA_DQ53_R[14,15,17] DDRA_DQ54_R[14,15,17] DDRA_DQ55_R[14,15,17] DDRA_DQ56_R[14,15,17] DDRA_DQ57_R[14,15,17] DDRA_DQ58_R[14,15,17] DDRA_DQ59_R[14,15,17] DQS7_A_R[14,15,17] DQS16_A_R[14,15,17] DDRA_DQ60_R[14,15,17] DDRA_DQ61_R[14,15,17] DDRA_DQ62_R[14,15,17] DDRA_DQ63_R[14,15,17] CB0_A_R[14,15,17] CB1_A_R[14,15,17] CB2_A_R[14,15,17] CB3_A_R[14,15,17] DQS8_A_R[14,15,17] DQS17_A_R[14,15,17] CB4_A_R[14,15,17] CB5_A_R[14,15,17] CB6_A_R[14,15,17] CB7_A_R[14,15,17]
4
DDRA_DQ0_R DDRA_DQ1_R DDRA_DQ2_R DDRA_DQ3_R DQS0_A_R DQS9_A_R DDRA_DQ4_R DDRA_DQ5_R DDRA_DQ6_R DDRA_DQ7_R DDRA_DQ8_R DDRA_DQ9_R DDRA_DQ10_R DDRA_DQ11_R DQS1_A_R DQS10_A_R DDRA_DQ12_R DDRA_DQ13_R DDRA_DQ14_R DDRA_DQ15_R DDRA_DQ16_R DDRA_DQ17_R DDRA_DQ18_R DDRA_DQ19_R DQS2_A_R DQS11_A_R DDRA_DQ20_R DDRA_DQ21_R DDRA_DQ22_R DDRA_DQ23_R DDRA_DQ24_R DDRA_DQ25_R DDRA_DQ26_R DDRA_DQ27_R DQS3_A_R DQS12_A_R DDRA_DQ28_R DDRA_DQ29_R DDRA_DQ30_R DDRA_DQ31_R DDRA_DQ32_R DDRA_DQ33_R DDRA_DQ34_R DDRA_DQ35_R DQS4_A_R DQS13_A_R DDRA_DQ36_R DDRA_DQ37_R DDRA_DQ38_R DDRA_DQ39_R DDRA_DQ40_R DDRA_DQ41_R DDRA_DQ42_R DDRA_DQ43_R DQS5_A_R DQS14_A_R DDRA_DQ44_R DDRA_DQ45_R DDRA_DQ46_R DDRA_DQ47_R DDRA_DQ48_R DDRA_DQ49_R DDRA_DQ50_R DDRA_DQ51_R DQS6_A_R DQS15_A_R DDRA_DQ52_R DDRA_DQ53_R DDRA_DQ54_R DDRA_DQ55_R DDRA_DQ56_R DDRA_DQ57_R DDRA_DQ58_R DDRA_DQ59_R DQS7_A_R DQS16_A_R DDRA_DQ60_R DDRA_DQ61_R DDRA_DQ62_R DDRA_DQ63_R CB0_A_R CB1_A_R CB2_A_R CB3_A_R DQS8_A_R DQS17_A_R CB4_A_R CB5_A_R CB6_A_R CB7_A_R
107 105 106 109 110
119 114 117 121 123
129 126 127 131 133
149 146 147 150 151
159 153 155 161 162
169 165 166 170 171
177 174 175 178 179
140 134 135 142 144
2 4 6 8
5 97 94 95 98 99 12 13 19 20 14
23 24 28 31 25
33 35 39 40 36
53 55 57 60 56
61 64 68 69 67
72 73 79 80 78
83 84 87 88 86
44 45 49 51 47
DQ0 DQ1 DQ2 DQ3 DQS0 DQS9 DQ4 DQ5 DQ6 DQ7 DQ8 DQ9 DQ10 DQ11 DQS1 DQS10 DQ12 DQ13 DQ14 DQ15 DQ16 DQ17 DQ18 DQ19 DQS2 DQS11 DQ20 DQ21 DQ22 DQ23 DQ24 DQ25 DQ26 DQ27 DQS3 DQS12 DQ28 DQ29 DQ30 DQ31 DQ32 DQ33 DQ34 DQ35 DQS4 DQS13 DQ36 DQ37 DQ38 DQ39 DQ40 DQ41 DQ42 DQ43 DQS5 DQS14 DQ44 DQ45 DQ46 DQ47 DQ48 DQ49 DQ50 DQ51 DQS6 DQS15 DQ52 DQ53 DQ54 DQ55 DQ56 DQ57 DQ58 DQ59 DQS7 DQS16 DQ60 DQ61 DQ62 DQ63 CB0 CB1 CB2 CB3 DQS8 DQS17 CB4 CB5 CB6 CB7
DDR DIMM_1
1
VREF
50
VSS
3
VSS1
11
VSS2
18
VSS3
26
VSS4
34
VSS5
42
VSS6
58
VSS7
66
VSS8
74
VSS9
81
VSS10
89
VSS11
176
VSS12
160
VSS13
152
VSS14
145
VSS15
139
VSS16
132
VSS17
124
VSS18
116
VSS19
100
VSS20
93
VSS21
82
VDDID
184
VDDSPD
7
VDD1
38
VDD2
46
VDD3
70
VDD4
85
VDD5
168
VDD6
148
VDD7
120
VDD8
108
VDD9
15
VDDQ1
22
VDDQ2
30
VDDQ3
54
VDDQ4
62
VDDQ5
77
VDDQ6
180
VDDQ7
172
VDDQ8
164
VDDQ9
156
VDDQ10
143
VDDQ11
136
VDDQ12
128
VDDQ13
112
VDDQ14
104
VDDQ15
96
VDDQ16
48
MA0
43
MA1
41
MA2
130
MA3
37
MA4
32
MA5
125
MA6
29
MA7
122
MA8
27
MA9
141
MA10
118
MA11
115
MA12
103
NC3
63
WE_N
65
CAS_N
154
RAS_N
9
NC1
90
NC2
173
NC_FETEN
102
NC4
101
NC5
71
NC_S2_N
163
NC_S3_N
167
MA13
10
RESET
16
DU_CK1
17
DU_CK1_N
75
DU_CK2
76
DU_CK2_N
21
CKE0
111
CKE1
59
BA0
52
BA1
113
BA2
137
CK0
138
CK0_N
3
SDA SCL SA0 SA1
SA2 S0_N S1_N
R1768 47/6
91 92 181 182 183 157 158
C1643
0.01U/6
VCC3 VCC2_5
DDRA_MA0_R DDRA_MA1_R DDRA_MA2_R DDRA_MA3_R DDRA_MA4_R DDRA_MA5_R DDRA_MA6_R DDRA_MA7_R DDRA_MA8_R DDRA_MA9_R DDRA_MA10_R DDRA_MA11_R DDRA_MA12_R
DDRA_WE_N_R DDRA_CAS_N_R DDRA_RAS_N_R
PCIRST2_5_N
DIMM_A3_SA0 DIMM_A3_SA1 DIMM_A3_SA2 DDRA_CS4_N_R DDRA_CS5_N_R
VDD_ID [15,19,20,49]
R191 0/6
R192 0/6
R193 0/6/X
DDRA_BA0_R DDRA_BA1_R
DDRA_CMDCLK2 D DRA_CMDCLK2_N ICH3_SMBDATA ICH3_SMBCLK
DDRA_CS4_N_R [12,17] DDRA_CS5_N_R [12,17]
VREF_DDR_DIMM [12,15,19,20,52]
C234
0.1U/6
DDRA_MA0_R [12,15,17] DDRA_MA1_R [12,15,17] DDRA_MA2_R [12,15,17] DDRA_MA3_R [12,15,17] DDRA_MA4_R [12,15,17] DDRA_MA5_R [12,15,17] DDRA_MA6_R [12,15,17] DDRA_MA7_R [12,15,17] DDRA_MA8_R [12,15,17] DDRA_MA9_R [12,15,17] DDRA_MA10_R [12,15,17] DDRA_MA11_R [12,15,17] DDRA_MA12_R [12,15,17]
DDRA_WE_N_R [12,15,17] DDRA_CAS_N_R [12,15,17] DDRA_RAS_N_R [12,15,17]
PCIRST2_5_N [11,15,19,20,36]
DDRA_CKE0 [12,15,17]
DDRA_CKE1 [12,15,17]
DDRA_BA0_R [12,15,17] DDRA_BA1_R [12,15,17]
DDRA_CMDCLK2 [12] D DRA_CMDCLK2_N [12]
ICH3_SMBDATA [11,15,19,20,24,37,46] ICH3_SMBCLK [11,15,19,20,24,37,46]
2
VCC3
R195
8.2K/6
DIMM_A3_SA1 DIMM_A3_SA0 DIMM_A3_SA2
R199
R197
8.2K/6
8.2K/6
010
Title
Size Document Number Rev
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
DDR DIMM A3
GA-8IPP533
16 58Tuesday, October 21, 2003
1
1.3
5
VTT_DDR
C235 0.1U/6
C236 0.1U/6
C238 0.1U/6
D D
C240 0.1U/6
C242 0.1U/6
C244 0.1U/6
C246 0.1U/6
C248 0.1U/6
C250 0.1U/6
C252 0.1U/6
C254 0.1U/6
C256 0.1U/6
C257 0.1U/6
C C
C258 0.1U/6
C259 0.1U/6
C260 0.1U/6
C262 0.1U/6
C264 0.1U/6
C266 0.1U/6
C268 0.1U/6
C270 0.1U/6
C272 0.1U/6
B B
C274 0.1U/6
C277 0.1U/6
C279 0.1U/6
C281 0.1U/6
C282 0.1U/6
C283 0.1U/6
C284 0.1U/6
C285 0.1U/6
C286 0.1U/6
C287 0.1U/6
A A
C288 0.1U/6
C289 0.1U/6
C290 0.1U/6
VTT_DDR
RN23
1 2 3 4 5 6 7 8
8P4R-39
RN26
1 2 3 4 5 6 7 8
8P4R-39
RN29
1 2 3 4 5 6 7 8
8P4R-39
RN32
1 2 3 4 5 6 7 8
8P4R-39
RN35
1 2 3 4 5 6 7 8
8P4R-39
RN38
1 2 3 4 5 6 7 8
8P4R-39
RN40
1 2 3 4 5 6 7 8
8P4R-39
RN42
1 2 3 4 5 6 7 8
8P4R-39
RN44
1 2 3 4 5 6 7 8
8P4R-39
RN46
1 2 3 4 5 6 7 8
8P4R-39
RN48
1 2 3 4 5 6 7 8
8P4R-39
RN50
1 2 3 4 5 6 7 8
8P4R-39
RN52
1 2 3 4 5 6 7 8
8P4R-39
DDRA_DQ1_R [14,15,16] DDRA_DQ5_R [14,15,16] DDRA_DQ4_R [14,15,16] DDRA_DQ0_R [14,15,16]
DDRA_DQ2_R [14,15,16] DDRA_DQ6_R [14,15,16] DQS9_A_R [14,15,16] DQS0_A_R [14,15,16]
DQS1_A_R [14,15,16] DQS16_A_R [14,15,16] DQS10_A_R [14,15,16] DDRA_DQ13_R [14,15,16] DDRA_DQ9_R [14,15,16]
DDRA_DQ11_R [14,15,16] DDRA_DQ10_R [14,15,16] DDRA_DQ15_R [14,15,16] DDRA_DQ14_R [14,15,16]
DDRA_DQ17_R [14,15,16] DDRA_MA12_R [12,15,16] DDRA_DQ16_R [14,15,16] DDRA_DQ20_R [14,15,16]
DDRA_DQ22_R [14,15,16] DDRA_MA7_R [12,15,16] DDRA_DQ18_R [14,15,16] DDRA_CKE0 [12,15,16] DQS11_A_R [14,15,16]
DDRA_DQ27_R [14,15,16] DDRA_DQ26_R [14,15,16] DDRA_DQ30_R [14,15,16] DDRA_MA3_R [12,15,16]
DDRA_MA4_R [12,15,16] DQS12_A_R [14,15,16] DQS3_A_R [14,15,16] DDRA_DQ25_R [14,15,16]
DDRA_DQ37_R [14,15,16] DDRA_DQ33_R [14,15,16] DDRA_DQ36_R [14,15,16] DDRA_DQ32_R [14,15,16]
DDRA_DQ38_R [14,15,16] DQS13_A_R [14,15,16] DDRA_DQ34_R [14,15,16] DQS4_A_R [14,15,16]
DDRA_DQ49_R [14,15,16] DDRA_DQ48_R [14,15,16] DDRA_DQ47_R [14,15,16] DDRA_DQ43_R [14,15,16]
DDRA_DQ44_R [14,15,16] DDRA_DQ35_R [14,15,16] DDRA_BA0_R [12,15,16] DDRA_DQ39_R [14,15,16]
DDRA_DQ51_R [14,15,16] DDRA_DQ55_R [14,15,16] DDRA_DQ50_R [14,15,16] DDRA_DQ54_R [14,15,16]
C291 0.1U/6
5
4
VTT_DDR
RN24
1 2 3 4 5 6 7 8
8P4R-39
RN27
1 2 3 4 5 6 7 8
8P4R-39
RN30
1 2 3 4 5 6 7 8
8P4R-39 RN33
1 2 3 4 5 6 7 8
8P4R-39
RN36
1 2 3 4 5 6 7 8
8P4R-39
R200 150/6/X R201 150/6/X R202 150/6/X R203 150/6/X R204 150/6/X R205 150/6/X R206 150/6/X R207 150/6/X R208 150/6/X R209 150/6/X R210 150/6/X R211 150/6/X R212 150/6/X R213 150/6/X R214 150/6/X R215 150/6/X R216 150/6/X R217 150/6/X
DQS17_A_R DQS16_A_R DQS15_A_R DQS14_A_R DQS13_A_R DQS12_A_R DQS11_A_R DQS10_A_R DQS9_A_R DQS8_A_R DQS7_A_R DQS6_A_R DQS5_A_R DQS4_A_R DQS3_A_R DQS2_A_R DQS1_A_R DQS0_A_R
VTT_DDR
C1625
100U/1210
4
C1624
100U/1210
C1630
100U/1210
3
DQS15_A_R [14,15,16] DQS6_A_R [14,15,16] DDRA_DQ53_R [14,15,16] DDRA_DQ52_R [14,15,16]
DDRA_DQ59_R [14,15,16] DDRA_DQ63_R [14,15,16] DDRA_DQ58_R [14,15,16] DDRA_DQ62_R [14,15,16]
DQS7_A_R [14,15,16] DDRA_DQ57_R [14,15,16] DDRA_DQ61_R [14,15,16]
DQS8_A_R [14,15,16] CB1_A_R [14,15,16] CB0_A_R [14,15,16] DDRA_MA1_R [12,15,16]
CB7_A_R [14,15,16] CB3_A_R [14,15,16] CB6_A_R [14,15,16] CB2_A_R [14,15,16]
C1631
100U/1210
3
VTT_DDR
VTT_DDR
C237 0.1U/6
C239 0.1U/6
C241 0.1U/6
C243 0.1U/6
C245 0.1U/6
C247 0.1U/6
C249 0.1U/6
C251 0.1U/6
C253 0.1U/6
C255 0.1U/6
C261 0.1U/6
C263 0.1U/6
C265 0.1U/6
C267 0.1U/6
C269 0.1U/6
C271 0.1U/6
C273 0.1U/6
C276 0.1U/6
C278 0.1U/6
C280 0.1U/6
2
1
VTT_DDR
RN25
1 2 3 4 5 6 7 8
8P4R-39
RN28
1 2 3 4 5 6 7 8
8P4R-39
RN31
1 2 3 4 5 6 7 8
8P4R-39
RN34
1 2 3 4 5 6 7 8
DDRA_DQ12_R [14,15,16] DDRA_DQ8_R [14,15,16] DDRA_DQ3_R [14,15,16] DDRA_DQ7_R [14,15,16]
DDRA_DQ29_R [14,15,16] DDRA_DQ28_R [14,15,16] DDRA_DQ24_R [14,15,16] DDRA_MA6_R [12,15,16]
DDRA_CS5_N_R [12,16] DDRA_CAS_N_R [12,15,16] DDRA_CS4_N_R [12,16] DDRA_DQ41_R [14,15,16]
DDRA_DQ56_R [14,15,16] DDRA_DQ60_R [14,15,16]
8P4R-39
RN37
1 2 3 4 5 6 7 8
DDRA_MA10_R [12,15,16] DQS17_A_R [14,15,16] DDRA_MA0_R [12,15,16]
8P4R-39
VTT_DDR
RN39
1 2 3 4 5 6 7 8
8P4R-39
RN41
1 2 3 4 5 6 7 8
8P4R-39
RN43
1 2 3 4 5 6 7 8
8P4R-39
RN45
1 2 3 4 5 6 7 8
8P4R-39
RN47
1 2 3 4 5 6 7 8
8P4R-39
RN49
1 2 3 4 5 6 7 8
8P4R-39
RN51
1 2 3 4 5 6 7 8
8P4R-39
Title
Size Document Number Rev
2
Date: Sheet of
DDRA_CKE1 [12,15,16] DDRA_BA1_R [12,15,16]
CB5_A_R [14,15,16] CB4_A_R [14,15,16] DDRA_MA2_R [12,15,16] DDRA_DQ31_R [14,15,16]
DDRA_MA5_R [12,15,16] DDRA_DQ23_R [14,15,16] DDRA_DQ19_R [14,15,16] DDRA_MA8_R [12,15,16]
DDRA_MA9_R [12,15,16] DDRA_MA11_R [12,15,16] DDRA_DQ21_R [14,15,16] DQS2_A_R [14,15,16]
DDRA_WE_N_R [12,15,16] DDRA_DQ45_R [14,15,16] DDRA_RAS_N_R [12,15,16] DDRA_DQ40_R [14,15,16]
DDRA_CS3_N_R [12,15] DDRA_CS1_N_R [12,15] DDRA_CS0_N_R [12,15] DDRB_CS6_N_R [12]
DDRA_DQ46_R [14,15,16] DDRA_DQ42_R [14,15,16] DQS5_A_R [14,15,16] DQS14_A_R [14,15,16]
GIGA-BYTE TECHNOLOGY CO., LTD.
DDR CHANNEL A TERMINATION
GA-8IPP533
17 58Tuesday, October 21, 2003
1
1.3
5
5
R220 10/6/1 R221 10/6/1
RN54
1 2 3 4 5 6 7 8
8P4R-10
RN56
1 2 3 4 5 6 7 8
8P4R-10
RN58
1 2 3 4 5 6 7 8
8P4R-10
RN60
1 2 3 4 5 6 7 8
8P4R-10
RN62
1 2 3 4 5 6 7 8
8P4R-10
RN64
1 2 3 4 5 6 7 8
8P4R-10
RN66
1 2 3 4 5 6 7 8
8P4R-10
RN68
1 2 3 4 5 6 7 8
8P4R-10
RN70
1 2 3 4 5 6 7 8
8P4R-10
RN72
1 2 3 4 5 6 7 8
8P4R-10
RN74
1 2 3 4 5 6 7 8
8P4R-10
DDRB_DQ0_R [19,20,21] DDRB_DQ4_R [19,20,21]
DDRB_DQ2_R [19,20,21] DDRB_DQ6_R [19,20,21] DDRB_DQ7_R [19,20,21] DDRB_DQ3_R [19,20,21]
DQS0_B_R [19,20,21] DQS9_B_R [19,20,21]
DDRB_DQ13_R [19,20,21] DQS10_B_R [19,20,21]
DDRB_DQ15_R [19,20,21]
DDRB_DQ8_R [19,20,21] DDRB_DQ12_R [19,20,21] DDRB_DQ9_R [19,20,21] DQS1_B_R [19,20,21]
DDRB_DQ10_R [19,20,21] DDRB_DQ11_R [19,20,21] DDRB_DQ20_R [19,20,21] DDRB_DQ16_R [19,20,21]
DDRB_DQ18_R [19,20,21] DDRB_DQ22_R [19,20,21] DDRB_DQ23_R [19,20,21] DDRB_DQ19_R [19,20,21]
DDRB_DQ17_R [19,20,21] DQS2_B_R [19,20,21] DDRB_DQ21_R [19,20,21] DQS11_B_R [19,20,21]
DQS3_B_R [19,20,21] DQS12_B_R [19,20,21] DDRB_DQ30_R [19,20,21] DDRB_DQ26_R [19,20,21]
DDRB_DQ24_R [19,20,21] DDRB_DQ28_R [19,20,21] DDRB_DQ29_R [19,20,21] DDRB_DQ25_R [19,20,21]
CB2_B_R [19,20,21] CB6_B_R [19,20,21] CB3_B_R [19,20,21] CB7_B_R [19,20,21]
DDRB_DQ32_R [19,20,21] DDRB_DQ36_R [19,20,21] DDRB_DQ33_R [19,20,21] DDRB_DQ37_R [19,20,21]
D D
C C
B B
A A
DDRB_DQ0[12] DDRB_DQ4[12]
DDRB_DQ2[12] DDRB_DQ6[12] DDRB_DQ7[12] DDRB_DQ3[12]
DDRB_DQ5[12] DDRB_DQ5_R [19,20,21] DDRB_DQ1[12] DDRB_DQ1_R [19,20,21] DQS0_B[12] DQS9_B[12]
DDRB_DQ13[12] DQS10_B[12] DDRB_DQ14[12] DDRB_DQ14_R [19,20,21] DDRB_DQ15[12]
DDRB_DQ8[12] DDRB_DQ12[12] DDRB_DQ9[12] DQS1_B[12]
DDRB_DQ10[12] DDRB_DQ11[12] DDRB_DQ20[12] DDRB_DQ16[12]
DDRB_DQ18[12] DDRB_DQ22[12] DDRB_DQ23[12] DDRB_DQ19[12]
DDRB_DQ17[12] DQS2_B[12] DDRB_DQ21[12] DQS11_B[12]
DQS3_B[12] DQS12_B[12] DDRB_DQ30[12] DDRB_DQ26[12]
DDRB_DQ24[12] DDRB_DQ28[12] DDRB_DQ29[12] DDRB_DQ25[12]
CB2_B[12] CB6_B[12] CB3_B[12] CB7_B[12]
DDRB_DQ32[12] DDRB_DQ36[12] DDRB_DQ33[12] DDRB_DQ37[12]
4
DDR Channel B Series Resistors
Place near DIMM B-1
DQS4_B[12] DQS4_B_R [19,20,21] DQS13_B[12] DDRB_DQ34[12] DDRB_DQ38[12]
DDRB_DQ42[12] DDRB_DQ46[12] DDRB_DQ43[12] DDRB_DQ47[12]
DDRB_DQ45[12] DDRB_DQ41[12] DQS14_B[12] DQS5_B[12]
DDRB_DQ48[12] DDRB_DQ48_R [19,20,21] DDRB_DQ52[12] DDRB_DQ52_R [19,20,21] DDRB_DQ49[12] DDRB_DQ49_R [19,20,21] DDRB_DQ53[12] DDRB_DQ53_R [19,20,21]
DDRB_DQ50[12] DDRB_DQ51[12] DDRB_DQ60[12] DDRB_DQ61[12]
DQS15_B[12] DQS15_B_R [19,20,21] DDRB_DQ54[12] DDRB_DQ54_R [19,20,21] DQS6_B[12] DQS6_B_R [19,20,21] DDRB_DQ55[12] DDRB_DQ55_R [19,20,21]
DDRB_DQ56[12] DDRB_DQ57[12] DQS16_B[12] DDRB_DQ62[12]
DQS7_B[12] DDRB_DQ58[12] DDRB_DQ63[12] DDRB_DQ59[12]
DDRB_DQ39[12] DDRB_DQ39_R [19,20,21] DDRB_DQ35[12] DDRB_DQ35_R [19,20,21] DDRB_DQ44[12] DDRB_DQ44_R [19,20,21] DDRB_DQ40[12] DDRB_DQ40_R [19,20,21]
CB0_B[12] CB1_B[12] DQS8_B[12] DQS17_B[12]
DDRB_DQ27[12] DDRB_DQ31[12] CB4_B[12] CB5_B[12]
4
3
1 2 3 4 5 6 7 8
8P4R-10
1 2 3 4 5 6 7 8
8P4R-10
1 2 3 4 5 6 7 8
8P4R-10
1 2 3 4 5 6 7 8
8P4R-10
1 2 3 4 5 6 7 8
8P4R-10
1 2 3 4 5 6 7 8
8P4R-10
1 2 3 4 5 6 7 8
8P4R-10
1 2 3 4 5 6 7 8
8P4R-10
1 2 3 4 5 6 7 8
8P4R-10
1 2 3 4 5 6 7 8
8P4R-10
1 2 3 4 5 6 7 8
8P4R-10
3
RN53
RN55
RN57
RN59
RN61
RN63
RN65
RN67
RN69
RN71
RN73
DQS13_B_R [19,20,21] DDRB_DQ34_R [19,20,21] DDRB_DQ38_R [19,20,21]
DDRB_DQ42_R [19,20,21] DDRB_DQ46_R [19,20,21] DDRB_DQ43_R [19,20,21] DDRB_DQ47_R [19,20,21]
DDRB_DQ45_R [19,20,21] DDRB_DQ41_R [19,20,21] DQS14_B_R [19,20,21] DQS5_B_R [19,20,21]
DDRB_DQ50_R [19,20,21] DDRB_DQ51_R [19,20,21] DDRB_DQ60_R [19,20,21] DDRB_DQ61_R [19,20,21]
DDRB_DQ56_R [19,20,21] DDRB_DQ57_R [19,20,21] DQS16_B_R [19,20,21] DDRB_DQ62_R [19,20,21]
DQS7_B_R [19,20,21] DDRB_DQ58_R [19,20,21] DDRB_DQ63_R [19,20,21] DDRB_DQ59_R [19,20,21]
CB0_B_R [19,20,21] CB1_B_R [19,20,21] DQS8_B_R [19,20,21] DQS17_B_R [19,20,21]
DDRB_DQ27_R [19,20,21] DDRB_DQ31_R [19,20,21] CB4_B_R [19,20,21] CB5_B_R [19,20,21]
2
VCC2_5 VCC2_5 VCC2_5
C292 0.1U/6
C295 0.1U/6
C298 0.1U/6
C301 0.1U/6
C304 0.01U/6
C307 0.01U/6
C293 0.1U/6
C296 0.1U/6
C299 0.1U/6
C302 0.1U/6
C305 0.01U/6
C308 0.01U/6
0.1UF Backside or Frontside Caps 6 Caps between each pair of DIMM
VCC2_5
EC33 150U/S
EC34 150U/S
EC35 150U/S
EC36 150U/S
EC37 150U/S
C1626 100U/1210
C1627 100U/1210
EC39 150U/S
EC40 150U/S
EC41 150U/S
VCC2_5
Place 100UF caps arrounding B DIMM
VCC2_5
C1526
C1523 22U/12
VCC2_5
C1529 22U/12
Title
Size Document Number Rev
2
Date: Sheet of
C1525
C1524 22U/12
C1530 22U/12
22U/12
C1531 22U/12
22U/12
C1532 22U/12
GIGA-BYTE TECHNOLOGY CO., LTD.
DDR CHANNEL B SERIES RESISTORS
GA-8IPP533
1
C294 0.1U/6
C297 0.1U/6
C300 0.1U/6
C303 0.1U/6
C306 0.01U/6
C309 0.01U/6
C1628 100U/1210
C1629 100U/1210
C1528
C1527
22U/12
22U/12
C1534
C1533
22U/12
22U/12
18 58Tuesday, October 21, 2003
1
1.3
5
DIMM B-1 DIMM B-2
107 105 106 109 110
119 114 117 121 123
129 126 127 131 133
149 146 147 150 151
159 153 155 161 162
169 165 166 170 171
177 174 175 178 179
140 134 135 142 144
J4
2
DQ0
4
DQ1
6
DQ2
8
DQ3
5
DQS0
97
DQS9
94
DQ4
95
DQ5
98
DQ6
99
DQ7
12
DQ8
13
DQ9
19
DQ10
20
DQ11
14
DQS1 DQS10 DQ12 DQ13 DQ14 DQ15
23
DQ16
24
DQ17
28
DQ18
31
DQ19
25
DQS2 DQS11 DQ20 DQ21 DQ22 DQ23
33
DQ24
35
DQ25
39
DQ26
40
DQ27
36
DQS3 DQS12 DQ28 DQ29 DQ30 DQ31
53
DQ32
55
DQ33
57
DQ34
60
DQ35
56
DQS4 DQS13 DQ36 DQ37 DQ38 DQ39
61
DQ40
64
DQ41
68
DQ42
69
DQ43
67
DQS5 DQS14 DQ44 DQ45 DQ46 DQ47
72
DQ48
73
DQ49
79
DQ50
80
DQ51
78
DQS6 DQS15 DQ52 DQ53 DQ54 DQ55
83
DQ56
84
DQ57
87
DQ58
88
DQ59
86
DQS7 DQS16 DQ60 DQ61 DQ62 DQ63
44
CB0
45
CB1
49
CB2
51
CB3
47
DQS8 DQS17 CB4 CB5 CB6 CB7
DDR DIMM_1
R238
8.2K/6
5
DDRB_DQ0_R DDRB_DQ1_R DDRB_DQ2_R DDRB_DQ3_R DQS0_B_R DQS9_B_R DDRB_DQ4_R DDRB_DQ5_R DDRB_DQ6_R DDRB_DQ7_R DDRB_DQ8_R DDRB_DQ9_R DDRB_DQ10_R DDRB_DQ11_R DQS1_B_R DQS10_B_R DDRB_DQ12_R DDRB_DQ13_R DDRB_DQ14_R DDRB_DQ15_R DDRB_DQ16_R DDRB_DQ17_R DDRB_DQ18_R DDRB_DQ19_R DQS2_B_R DQS11_B_R DDRB_DQ20_R DDRB_DQ21_R DDRB_DQ22_R DDRB_DQ23_R DDRB_DQ24_R DDRB_DQ25_R DDRB_DQ26_R DDRB_DQ27_R DQS3_B_R DQS12_B_R DDRB_DQ28_R DDRB_DQ29_R DDRB_DQ30_R DDRB_DQ31_R DDRB_DQ32_R DDRB_DQ33_R DDRB_DQ34_R DDRB_DQ35_R DQS4_B_R DQS13_B_R DDRB_DQ36_R DDRB_DQ37_R DDRB_DQ38_R DDRB_DQ39_R DDRB_DQ40_R DDRB_DQ41_R DDRB_DQ42_R DDRB_DQ43_R DQS5_B_R DQS14_B_R DDRB_DQ44_R DDRB_DQ45_R DDRB_DQ46_R DDRB_DQ47_R DDRB_DQ48_R DDRB_DQ49_R DDRB_DQ50_R DDRB_DQ51_R DQS6_B_R DQS15_B_R DDRB_DQ52_R DDRB_DQ53_R DDRB_DQ54_R DDRB_DQ55_R DDRB_DQ56_R DDRB_DQ57_R DDRB_DQ58_R DDRB_DQ59_R DQS7_B_R DQS16_B_R DDRB_DQ60_R DDRB_DQ61_R DDRB_DQ62_R DDRB_DQ63_R CB0_B_R CB1_B_R CB2_B_R CB3_B_R DQS8_B_R DQS17_B_R CB4_B_R CB5_B_R CB6_B_R CB7_B_R
R239
8.2K/6
DDRB_DQ0_R[18,20,21] DDRB_DQ1_R[18,20,21] DDRB_DQ2_R[18,20,21] DDRB_DQ3_R[18,20,21] DQS0_B_R[18,20,21] DQS9_B_R[18,20,21]
D D
C C
B B
A A
DDRB_DQ4_R[18,20,21] DDRB_DQ5_R[18,20,21] DDRB_DQ6_R[18,20,21] DDRB_DQ7_R[18,20,21] DDRB_DQ8_R[18,20,21] DDRB_DQ9_R[18,20,21] DDRB_DQ10_R[18,20,21] DDRB_DQ11_R[18,20,21] DQS1_B_R[18,20,21] DQS10_B_R[18,20,21] DDRB_DQ12_R[18,20,21] DDRB_DQ13_R[18,20,21] DDRB_DQ14_R[18,20,21] DDRB_DQ15_R[18,20,21] DDRB_DQ16_R[18,20,21] DDRB_DQ17_R[18,20,21] DDRB_DQ18_R[18,20,21] DDRB_DQ19_R[18,20,21] DQS2_B_R[18,20,21] DQS11_B_R[18,20,21] DDRB_DQ20_R[18,20,21] DDRB_DQ21_R[18,20,21] DDRB_DQ22_R[18,20,21] DDRB_DQ23_R[18,20,21] DDRB_DQ24_R[18,20,21] DDRB_DQ25_R[18,20,21] DDRB_DQ26_R[18,20,21] DDRB_DQ27_R[18,20,21] DQS3_B_R[18,20,21] DQS12_B_R[18,20,21] DDRB_DQ28_R[18,20,21] DDRB_DQ29_R[18,20,21] DDRB_DQ30_R[18,20,21] DDRB_DQ31_R[18,20,21] DDRB_DQ32_R[18,20,21] DDRB_DQ33_R[18,20,21] DDRB_DQ34_R[18,20,21] DDRB_DQ35_R[18,20,21] DQS4_B_R[18,20,21] DQS13_B_R[18,20,21] DDRB_DQ36_R[18,20,21] DDRB_DQ37_R[18,20,21] DDRB_DQ38_R[18,20,21] DDRB_DQ39_R[18,20,21] DDRB_DQ40_R[18,20,21] DDRB_DQ41_R[18,20,21] DDRB_DQ42_R[18,20,21] DDRB_DQ43_R[18,20,21] DQS5_B_R[18,20,21] DQS14_B_R[18,20,21] DDRB_DQ44_R[18,20,21] DDRB_DQ45_R[18,20,21] DDRB_DQ46_R[18,20,21] DDRB_DQ47_R[18,20,21] DDRB_DQ48_R[18,20,21] DDRB_DQ49_R[18,20,21] DDRB_DQ50_R[18,20,21] DDRB_DQ51_R[18,20,21] DQS6_B_R[18,20,21] DQS15_B_R[18,20,21] DDRB_DQ52_R[18,20,21] DDRB_DQ53_R[18,20,21] DDRB_DQ54_R[18,20,21] DDRB_DQ55_R[18,20,21] DDRB_DQ56_R[18,20,21] DDRB_DQ57_R[18,20,21] DDRB_DQ58_R[18,20,21] DDRB_DQ59_R[18,20,21] DQS7_B_R[18,20,21] DQS16_B_R[18,20,21] DDRB_DQ60_R[18,20,21] DDRB_DQ61_R[18,20,21] DDRB_DQ62_R[18,20,21] DDRB_DQ63_R[18,20,21] CB0_B_R[18,20,21] CB1_B_R[18,20,21] CB2_B_R[18,20,21] CB3_B_R[18,20,21] DQS8_B_R[18,20,21] DQS17_B_R[18,20,21] CB4_B_R[18,20,21] CB5_B_R[18,20,21] CB6_B_R[18,20,21] CB7_B_R[18,20,21]
DIMM_B1_SA1
DIMM_B1_SA2
VCC3
R231
8.2K/6
100
VREF
VSS VSS1 VSS2 VSS3 VSS4 VSS5 VSS6 VSS7 VSS8 VSS9
VSS10 VSS11 VSS12 VSS13 VSS14 VSS15 VSS16 VSS17 VSS18 VSS19 VSS20 VSS21
VDDID
VDDSPD
VDD1 VDD2 VDD3 VDD4 VDD5 VDD6 VDD7 VDD8 VDD9
VDDQ1 VDDQ2 VDDQ3 VDDQ4 VDDQ5 VDDQ6 VDDQ7 VDDQ8
VDDQ9 VDDQ10 VDDQ11 VDDQ12 VDDQ13 VDDQ14 VDDQ15 VDDQ16
MA0 MA1 MA2 MA3 MA4 MA5 MA6 MA7 MA8
MA9 MA10 MA11 MA12
NC3
WE_N
CAS_N RAS_N
NC1 NC2
NC_FETEN
NC4
NC5 NC_S2_N NC_S3_N
MA13
RESET
DU_CK1
DU_CK1_N
DU_CK2
DU_CK2_N
CKE0 CKE1
BA0
BA1
BA2
CK0
CK0_N
SDA
SCL
SA0
SA1
SA2
S0_N S1_N
4
1 50 3 11 18 26 34 42 58 66 74 81 89 176 160 152 145 139 132 124 116 100 93 82 184 7 38 46 70 85 168 148 120 108 15 22 30 54 62 77 180 172 164 156 143 136 128 112 104 96
DDRB_MA0_R
48
DDRB_MA1_R
43
DDRB_MA2_R
41
DDRB_MA3_R
130
DDRB_MA4_R
37
DDRB_MA5_R
32
DDRB_MA6_R
125
DDRB_MA7_R
29
DDRB_MA8_R
122
DDRB_MA9_R
27
DDRB_MA10_R
141
DDRB_MA11_R
118
DDRB_MA12_R
115 103
DDRB_WE_N_R
63
DDRB_CAS_N_R
65
DDRB_RAS_N_R
154 9 90 173 102 101 71 163 167 10 16 17 75 76 21 111 59 52 113 137 138 91
R1769 47/6
92
DIMM_B1_SA0
181
DIMM_B1_SA1
182
DIMM_B1_SA2
183
DDRB_CS0_N_R
157
DDRB_CS1_N_R
158
4
VREF_DDR_DIMM
C1644
0.01U/6
VDD_ID
PCIRST2_5_N
VDD_ID [15,16,20,49]
VCC3 VCC2_5 VCC2_5
DDRB_MA0_R [12,20,21] DDRB_MA1_R [12,20,21] DDRB_MA2_R [12,20,21] DDRB_MA3_R [12,20,21] DDRB_MA4_R [12,20,21] DDRB_MA5_R [12,20,21] DDRB_MA6_R [12,20,21] DDRB_MA7_R [12,20,21] DDRB_MA8_R [12,20,21] DDRB_MA9_R [12,20,21] DDRB_MA10_R [12,20,21] DDRB_MA11_R [12,20,21] DDRB_MA12_R [12,20,21]
DDRB_WE_N_R [12,20,21] DDRB_CAS_N_R [12,20,21] DDRB_RAS_N_R [12,20,21]
PCIRST2_5_N [11,15,16,20,36]
R222 0/6
R224 0/6
R226 0/6/X R227 0/6/X
DDRB_BA0_R DDRB_BA1_R
DDRB_CMDCLK0 DDRB_CMDCLK0_N ICH3_SMBDATA ICH3_SMBDATA ICH3_SMBCLK ICH3_SMBCLK
DDRB_CS0_N_R [12,21] DDRB_CS1_N_R [12,21] DDRB_CS3_N_R [12,21]
VREF_DDR_DIMM [12,15,16,20,52]
C310
0.1U/6
DDRB_CKE0
DDRB_CKE1
DDRB_CKE0 [12,20,21]
DDRB_CKE1 [12,20,21] DDRB_BA0_R [12,20,21] DDRB_BA1_R [12,20,21]
DDRB_CMDCLK0 [12] D DRB_CMDCLK0_N [12]
ICH3_SMBDATA [11,15,16,20,24,37,46] ICH3_SMBDATA [11,15,16,20,24,37,46] ICH3_SMBCLK [11,15,16,20,24,37,46] ICH3_SMBCLK [11,15,16,20,24,37,46]
3
DIMM_B2_SA0 DIMM_B2_SA2DIMM_B1_SA0 DIMM_B2_SA1
101
3
R228
8.2K/6
DDRB_DQ0_R DDRB_DQ1_R DDRB_DQ2_R DDRB_DQ3_R DQS0_B_R DQS9_B_R DDRB_DQ4_R DDRB_DQ5_R DDRB_DQ6_R DDRB_DQ7_R DDRB_DQ8_R DDRB_DQ9_R DDRB_DQ10_R DDRB_DQ11_R DQS1_B_R DQS10_B_R DDRB_DQ12_R DDRB_DQ13_R DDRB_DQ14_R DDRB_DQ15_R DDRB_DQ16_R DDRB_DQ17_R DDRB_DQ18_R DDRB_DQ19_R DQS2_B_R DQS11_B_R DDRB_DQ20_R DDRB_DQ21_R DDRB_DQ22_R DDRB_DQ23_R DDRB_DQ24_R DDRB_DQ25_R DDRB_DQ26_R DDRB_DQ27_R DQS3_B_R DQS12_B_R DDRB_DQ28_R DDRB_DQ29_R DDRB_DQ30_R DDRB_DQ31_R DDRB_DQ32_R DDRB_DQ33_R DDRB_DQ34_R DDRB_DQ35_R DQS4_B_R DQS13_B_R DDRB_DQ36_R DDRB_DQ37_R DDRB_DQ38_R DDRB_DQ39_R DDRB_DQ40_R DDRB_DQ41_R DDRB_DQ42_R DDRB_DQ43_R DDRB_MA3_R DQS5_B_R DQS14_B_R DDRB_DQ44_R DDRB_DQ45_R DDRB_DQ46_R DDRB_DQ47_R DDRB_DQ48_R DDRB_DQ49_R DDRB_DQ50_R DDRB_DQ51_R DQS6_B_R DQS15_B_R DDRB_DQ52_R DDRB_DQ53_R DDRB_DQ54_R DDRB_DQ55_R DDRB_DQ56_R DDRB_DQ57_R DDRB_DQ58_R DDRB_DQ59_R DQS7_B_R DQS16_B_R DDRB_DQ60_R DDRB_DQ61_R DDRB_DQ62_R DDRB_DQ63_R CB0_B_R CB1_B_R CB2_B_R CB3_B_R DQS8_B_R DQS17_B_R CB4_B_R CB5_B_R CB6_B_R CB7_B_R
VCC3
R230
8.2K/6
R235
8.2K/6
107 105 106 109 110
119 114 117 121 123
129 126 127 131 133
149 146 147 150 151
159 153 155 161 162
169 165 166 170 171
177 174 175 178 179
140 134 135 142 144
2 4 6 8
5 97 94 95 98 99 12 13 19 20 14
23 24 28 31 25
33 35 39 40 36
53 55 57 60 56
61 64 68 69 67
72 73 79 80 78
83 84 87 88 86
44 45 49 51 47
J5
DQ0 DQ1 DQ2 DQ3 DQS0 DQS9 DQ4 DQ5 DQ6 DQ7 DQ8 DQ9 DQ10 DQ11 DQS1 DQS10 DQ12 DQ13 DQ14 DQ15 DQ16 DQ17 DQ18 DQ19 DQS2 DQS11 DQ20 DQ21 DQ22 DQ23 DQ24 DQ25 DQ26 DQ27 DQS3 DQS12 DQ28 DQ29 DQ30 DQ31 DQ32 DQ33 DQ34 DQ35 DQS4 DQS13 DQ36 DQ37 DQ38 DQ39 DQ40 DQ41 DQ42 DQ43 DQS5 DQS14 DQ44 DQ45 DQ46 DQ47 DQ48 DQ49 DQ50 DQ51 DQS6 DQS15 DQ52 DQ53 DQ54 DQ55 DQ56 DQ57 DQ58 DQ59 DQS7 DQS16 DQ60 DQ61 DQ62 DQ63 CB0 CB1 CB2 CB3 DQS8 DQS17 CB4 CB5 CB6 CB7
2
DDR DIMM_1
2
VREF
VSS VSS1 VSS2 VSS3 VSS4 VSS5 VSS6 VSS7 VSS8 VSS9
VSS10 VSS11 VSS12 VSS13 VSS14 VSS15 VSS16 VSS17 VSS18 VSS19 VSS20 VSS21
VDDID
VDDSPD
VDD1 VDD2 VDD3 VDD4 VDD5 VDD6 VDD7 VDD8 VDD9
VDDQ1 VDDQ2 VDDQ3 VDDQ4 VDDQ5 VDDQ6 VDDQ7 VDDQ8
VDDQ9 VDDQ10 VDDQ11 VDDQ12 VDDQ13 VDDQ14 VDDQ15 VDDQ16
MA0 MA1 MA2 MA3 MA4 MA5 MA6 MA7 MA8
MA9 MA10 MA11 MA12
NC3
WE_N
CAS_N RAS_N
NC1 NC2
NC_FETEN
NC4
NC5 NC_S2_N NC_S3_N
MA13
RESET
DU_CK1
DU_CK1_N
DU_CK2
DU_CK2_N
CKE0 CKE1
BA0
BA1
BA2
CK0
CK0_N
SDA
SCL
SA0
SA1
SA2
S0_N S1_N
VREF_DDR_DIMM
1 50 3 11 18 26 34 42 58 66 74 81 89 176 160 152 145 139 132 124 116 100 93
VDD_ID
82 184 7 38 46 70 85 168 148 120 108 15 22 30 54 62 77 180 172 164 156 143 136 128 112 104 96
DDRB_MA0_R
48
DDRB_MA1_R
43
DDRB_MA2_R
41 130
DDRB_MA4_R
37
DDRB_MA5_R
32
DDRB_MA6_R
125
DDRB_MA7_R
29
DDRB_MA8_R
122
DDRB_MA9_R
27
DDRB_MA10_R
141
DDRB_MA11_R
118
DDRB_MA12_R
115 103
DDRB_WE_N_R
63
DDRB_CAS_N_R
65
DDRB_RAS_N_R
154 9 90 173
PCIRST2_5_N
102 101 71 163 167 10 16 17 75 76 21 111
DDRB_BA0_R
59
DDRB_BA1_R
52 113 137 138
R1770 47/6
91 92
DIMM_B2_SA0
181
DIMM_B2_SA1
182
DIMM_B2_SA2
183
DDRB_CS2_N_R
157
DDRB_CS3_N_R
158
Title
Size Document Number Rev
Date: Sheet of
1
C311
C1645
0.1U/6
0.01U/6
VCC3
R223 0/6
R225 0/6
DDRB_CMDCLK1
D DRB_CMDCLK1_N
DDRB_CKE0
DDRB_CKE1
DDRB_CMDCLK1 [12] D DRB_CMDCLK1_N [12]
DDRB_CS2_N_R [12,21]
GIGA-BYTE TECHNOLOGY CO., LTD.
DDR DIMM B1 AND B2
GA-8IPP533
19 58Tuesday, October 21, 2003
1
1.3
5
4
3
2
1
VREF_DDR_DIMM
DIMM B-3
J6
107 105 106 109 110
119 114 117 121 123
129 126 127 131 133
149 146 147 150 151
159 153 155 161 162
169 165 166 170 171
177 174 175 178 179
140 134 135 142 144
2
DQ0
4
DQ1
6
DQ2
8
DQ3
5
DQS0
97
DQS9
94
DQ4
95
DQ5
98
DQ6
99
DQ7
12
DQ8
13
DQ9
19
DQ10
20
DQ11
14
DQS1 DQS10 DQ12 DQ13 DQ14 DQ15
23
DQ16
24
DQ17
28
DQ18
31
DQ19
25
DQS2 DQS11 DQ20 DQ21 DQ22 DQ23
33
DQ24
35
DQ25
39
DQ26
40
DQ27
36
DQS3 DQS12 DQ28 DQ29 DQ30 DQ31
53
DQ32
55
DQ33
57
DQ34
60
DQ35
56
DQS4 DQS13 DQ36 DQ37 DQ38 DQ39
61
DQ40
64
DQ41
68
DQ42
69
DQ43
67
DQS5 DQS14 DQ44 DQ45 DQ46 DQ47
72
DQ48
73
DQ49
79
DQ50
80
DQ51
78
DQS6 DQS15 DQ52 DQ53 DQ54 DQ55
83
DQ56
84
DQ57
87
DQ58
88
DQ59
86
DQS7 DQS16 DQ60 DQ61 DQ62 DQ63
44
CB0
45
CB1
49
CB2
51
CB3
47
DQS8 DQS17 CB4 CB5 CB6 CB7
DDRB_DQ0_R[18,19,21] DDRB_DQ1_R[18,19,21]
D D
C C
B B
A A
DDRB_DQ2_R[18,19,21] DDRB_DQ3_R[18,19,21]
DQS0_B_R[18,19,21]
DQS9_B_R[18,19,21] DDRB_DQ4_R[18,19,21] DDRB_DQ5_R[18,19,21] DDRB_DQ6_R[18,19,21] DDRB_DQ7_R[18,19,21] DDRB_DQ8_R[18,19,21] DDRB_DQ9_R[18,19,21] DDRB_DQ10_R[18,19,21] DDRB_DQ11_R[18,19,21]
DQS1_B_R[18,19,21]
DQS10_B_R[18,19,21] DDRB_DQ12_R[18,19,21] DDRB_DQ13_R[18,19,21] DDRB_DQ14_R[18,19,21] DDRB_DQ15_R[18,19,21] DDRB_DQ16_R[18,19,21] DDRB_DQ17_R[18,19,21] DDRB_DQ18_R[18,19,21] DDRB_DQ19_R[18,19,21]
DQS2_B_R[18,19,21]
DQS11_B_R[18,19,21] DDRB_DQ20_R[18,19,21] DDRB_DQ21_R[18,19,21] DDRB_DQ22_R[18,19,21] DDRB_DQ23_R[18,19,21] DDRB_DQ24_R[18,19,21] DDRB_DQ25_R[18,19,21] DDRB_DQ26_R[18,19,21] DDRB_DQ27_R[18,19,21]
DQS3_B_R[18,19,21]
DQS12_B_R[18,19,21] DDRB_DQ28_R[18,19,21] DDRB_DQ29_R[18,19,21] DDRB_DQ30_R[18,19,21] DDRB_DQ31_R[18,19,21] DDRB_DQ32_R[18,19,21] DDRB_DQ33_R[18,19,21] DDRB_DQ34_R[18,19,21] DDRB_DQ35_R[18,19,21]
DQS4_B_R[18,19,21]
DQS13_B_R[18,19,21] DDRB_DQ36_R[18,19,21] DDRB_DQ37_R[18,19,21] DDRB_DQ38_R[18,19,21] DDRB_DQ39_R[18,19,21] DDRB_DQ40_R[18,19,21] DDRB_DQ41_R[18,19,21] DDRB_DQ42_R[18,19,21] DDRB_DQ43_R[18,19,21]
DQS5_B_R[18,19,21]
DQS14_B_R[18,19,21] DDRB_DQ44_R[18,19,21] DDRB_DQ45_R[18,19,21] DDRB_DQ46_R[18,19,21] DDRB_DQ47_R[18,19,21] DDRB_DQ48_R[18,19,21] DDRB_DQ49_R[18,19,21] DDRB_DQ50_R[18,19,21] DDRB_DQ51_R[18,19,21]
DQS6_B_R[18,19,21]
DQS15_B_R[18,19,21] DDRB_DQ52_R[18,19,21] DDRB_DQ53_R[18,19,21] DDRB_DQ54_R[18,19,21] DDRB_DQ55_R[18,19,21] DDRB_DQ56_R[18,19,21] DDRB_DQ57_R[18,19,21] DDRB_DQ58_R[18,19,21] DDRB_DQ59_R[18,19,21]
DQS7_B_R[18,19,21]
DQS16_B_R[18,19,21] DDRB_DQ60_R[18,19,21] DDRB_DQ61_R[18,19,21] DDRB_DQ62_R[18,19,21] DDRB_DQ63_R[18,19,21]
CB0_B_R[18,19,21]
CB1_B_R[18,19,21]
CB2_B_R[18,19,21]
CB3_B_R[18,19,21]
DQS8_B_R[18,19,21]
DQS17_B_R[18,19,21]
CB4_B_R[18,19,21]
CB5_B_R[18,19,21]
CB6_B_R[18,19,21]
CB7_B_R[18,19,21]
DDR DIMM
5
4
3
VREF
VSS VSS1 VSS2 VSS3 VSS4 VSS5 VSS6 VSS7 VSS8 VSS9
VSS10 VSS11 VSS12 VSS13 VSS14 VSS15 VSS16 VSS17 VSS18 VSS19 VSS20 VSS21
VDDID
VDDSPD
VDD1 VDD2 VDD3 VDD4 VDD5 VDD6 VDD7 VDD8 VDD9
VDDQ1 VDDQ2 VDDQ3 VDDQ4 VDDQ5 VDDQ6 VDDQ7 VDDQ8
VDDQ9 VDDQ10 VDDQ11 VDDQ12 VDDQ13 VDDQ14 VDDQ15 VDDQ16
MA0 MA1 MA2 MA3 MA4 MA5 MA6 MA7 MA8
MA9 MA10 MA11 MA12
NC3
WE_N
CAS_N RAS_N
NC1 NC2
NC_FETEN
NC4
NC5 NC_S2_N NC_S3_N
MA13
RESET
DU_CK1
DU_CK1_N
DU_CK2
DU_CK2_N
CKE0 CKE1
BA0
BA1
BA2
CK0
CK0_N
SDA
SCL
SA0
SA1
SA2
S0_N S1_N
1 50 3 11 18 26 34 42 58 66 74 81 89 176 160 152 145 139 132 124 116 100 93 82 184 7 38 46 70 85 168 148 120 108 15 22 30 54 62 77 180 172 164 156 143 136 128 112 104 96 48 43 41 130 37 32 125 29 122 27 141 118 115 103 63 65 154 9 90 173 102 101 71 163 167 10 16 17 75 76 21 111 59 52 113 137 138
R1771 47/6
91 92
DIMM_B3_SA0
181
DIMM_B3_SA1
182
DIMM_B3_SA2
183
DDRB_CS4_N_R
157
DDRB_CS5_N_R
158
C1646
0.01U/6
VDD_ID [15,16,19,49]
VCC3 VCC2_5
DDRB_MA0_R [12,19,21] DDRB_MA1_R [12,19,21] DDRB_MA2_R [12,19,21] DDRB_MA3_R [12,19,21] DDRB_MA4_R [12,19,21] DDRB_MA5_R [12,19,21] DDRB_MA6_R [12,19,21] DDRB_MA7_R [12,19,21] DDRB_MA8_R [12,19,21] DDRB_MA9_R [12,19,21] DDRB_MA10_R [12,19,21] DDRB_MA11_R [12,19,21] DDRB_MA12_R [12,19,21]
DDRB_WE_N_R [12,19,21] DDRB_CAS_N_R [12,19,21] DDRB_RAS_N_R [12,19,21]
PCIRST2_5_N
R240 0/6
R241 0/6
R245 0/6/X
PCIRST2_5_N [11,15,16,19,36]
DDRB_BA0_R DDRB_BA1_R
DDRB_CMDCLK2 DDRB_CMDCLK2_N
ICH3_SMBDATA ICH3_SMBCLK
DDRB_CS4_N_R [12,21] DDRB_CS5_N_R [12,21]
VREF_DDR_DIMM [12,15,16,19,52]
C312
0.1U/6
DDRB_CKE0 [12,19,21]
DDRB_CKE1 [12,19,21] DDRB_BA0_R [12,19,21] DDRB_BA1_R [12,19,21]
DDRB_CMDCLK2 [12] D DRB_CMDCLK2_N [12]
ICH3_SMBDATA [11,15,16,19,24,37,46] ICH3_SMBCLK [11,15,16,19,24,37,46]
2
VCC3
R243
R242
8.2K/6
8.2K/6
DIMM_B3_SA2 DIMM_B3_SA1 DIMM_B3_SA0
110
Title
Size Document Number Rev
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
DDR DIMM B3
GA-8IPP533
R248
8.2K/6
20 58Tuesday, October 21, 2003
1
1.3
5
C313 0.1U/6
C315 0.1U/6
C317 0.1U/6
D D
C319 0.1U/6
C321 0.1U/6
C323 0.1U/6
C325 0.1U/6
C327 0.1U/6
C329 0.1U/6
C331 0.1U/6
C333 0.1U/6
C334 0.1U/6
C C
C335 0.1U/6
C336 0.1U/6
C337 0.1U/6
C338 0.1U/6
C340 0.1U/6
C342 0.1U/6
C344 0.1U/6
C346 0.1U/6
C348 0.1U/6
C351 0.1U/6
B B
C353 0.1U/6
C355 0.1U/6
C357 0.1U/6
C360 0.1U/6
C361 0.1U/6
C362 0.1U/6
C363 0.1U/6
C364 0.1U/6
A A
C365 0.1U/6
C366 0.1U/6
C367 0.1U/6
C368 0.1U/6
RN75
1 2 3 4 5 6 7 8
8P4R-39
RN78
1 2 3 4 5 6 7 8
8P4R-39
RN81
1 2 3 4 5 6 7 8
8P4R-39
RN84
1 2 3 4 5 6 7 8
8P4R-39
RN87
1 2 3 4 5 6 7 8
8P4R-39
RN90
1 2 3 4 5 6 7 8
8P4R-39
RN92
1 2 3 4 5 6 7 8
8P4R-39
RN94
1 2 3 4 5 6 7 8
8P4R-39
RN96
1 2 3 4 5 6 7 8
8P4R-39
RN98
1 2 3 4 5 6 7 8
8P4R-39
RN100
1 2 3 4 5 6 7 8
8P4R-39
RN102
1 2 3 4 5 6 7 8
8P4R-39
RN104
1 2 3 4 5 6 7 8
8P4R-39
C369 0.1U/6
5
4
3
VTT_DDRVTT_DDRVTT_DDR
RN76
DDRB_DQ5_R [18,19,20] DDRB_DQ1_R [18,19,20] DDRB_DQ4_R [18,19,20] DDRB_DQ0_R [18,19,20]
DQS0_B_R [18,19,20] DDRB_DQ2_R [18,19,20] DQS9_B_R [18,19,20] DDRB_DQ3_R [18,19,20]
DDRB_DQ12_R [18,19,20] DDRB_DQ13_R [18,19,20] DDRB_DQ7_R [18,19,20] DQS16_B_R [18,19,20] DDRB_DQ6_R [18,19,20]
DDRB_DQ11_R [18,19,20] DDRB_DQ15_R [18,19,20] DDRB_DQ14_R [18,19,20] DDRB_DQ10_R [18,19,20]
DDRB_MA12_R [12,19,20] DDRB_MA11_R [12,19,20] DDRB_MA9_R [12,19,20] DDRB_DQ18_R [18,19,20]
DDRB_DQ19_R [18,19,20] DDRB_DQ22_R [18,19,20] DQS11_B_R [18,19,20] DDRB_DQ21_R [18,19,20]
DDRB_CKE1 [12,19,20] DDRB_CKE0 [12,19,20] DDRB_MA7_R [12,19,20] DDRB_MA8_R [12,19,20]
DDRB_DQ25_R [18,19,20] DDRB_DQ24_R [18,19,20] DDRB_MA5_R [12,19,20] DDRB_DQ23_R [18,19,20]
DDRB_DQ39_R [18,19,20] DDRB_BA0_R [12,19,20] DDRB_DQ38_R [18,19,20] DQS13_B_R [18,19,20]
DDRB_DQ37_R [18,19,20] DDRB_DQ33_R [18,19,20] DQS4_B_R [18,19,20] DDRB_DQ34_R [18,19,20]
DDRB_DQ46_R [18,19,20] DQS14_B_R [18,19,20] DDRB_CAS_N_R [12,19,20] DDRB_CS7_N_R [12]
DDRB_CS4_N_R [12,20] DDRB_DQ41_R [18,19,20] DDRB_DQ45_R [18,19,20] DDRB_WE_N_R [12,19,20]
DDRB_DQ60_R [18,19,20] DDRB_DQ50_R [18,19,20] DDRB_DQ55_R [18,19,20] DDRB_DQ54_R [18,19,20]
4
1 2 3 4 5 6 7 8
8P4R-39
RN79
1 2 3 4 5 6 7 8
8P4R-39
RN82
1 2 3 4 5 6 7 8
8P4R-39
RN85
1 2 3 4 5 6 7 8
8P4R-39
RN88
1 2 3 4 5 6 7 8
8P4R-39
DDRA_CS2_N_R [12,15] DDRB_DQ48_R [18,19,20] DDRB_DQ49_R [18,19,20] DQS6_B_R [18,19,20]
DDRB_DQ57_R [18,19,20] DQS7_B_R [18,19,20] DDRB_DQ58_R [18,19,20] DDRB_DQ59_R [18,19,20]
DDRB_DQ63_R [18,19,20] DDRB_DQ62_R [18,19,20]
DDRB_DQ61_R [18,19,20]
DDRB_MA10_R [12,19,20] DQS17_B_R [18,19,20] DQS8_B_R [18,19,20] CB1_B_R [18,19,20]
DDRB_MA0_R [12,19,20] CB2_B_R [18,19,20] CB3_B_R [18,19,20] CB7_B_R [18,19,20]
EC43 150U/S
VTT_DDR
C1622
100U/1210
3
C1623
100U/1210
VTT_DDR
VTT_DDR
C314 0.1U/6
C316 0.1U/6
C318 0.1U/6
C320 0.1U/6
C322 0.1U/6
C324 0.1U/6
C326 0.1U/6
C328 0.1U/6
C330 0.1U/6
C332 0.1U/6
C339 0.1U/6
C341 0.1U/6
C343 0.1U/6
C345 0.1U/6
C347 0.1U/6
C350 0.1U/6
C352 0.1U/6
C354 0.1U/6
C356 0.1U/6
C358 0.1U/6
2
1
VTT_DDR
RN77
1 2 3 4 5 6 7 8
8P4R-39
RN80
1 2 3 4 5 6 7 8
8P4R-39
RN83
1 2 3 4 5 6 7 8
8P4R-39
RN86
1 2 3 4 5 6 7 8
8P4R-39
RN89
1 2 3 4 5 6 7 8
VTT_DDR
8P4R-39
RN91
1 2 3 4 5 6 7 8
8P4R-39
RN93
1 2 3 4 5 6 7 8
8P4R-39
RN95
1 2 3 4 5 6 7 8
8P4R-39
RN97
1 2 3 4 5 6 7 8
8P4R-39
RN99
1 2 3 4 5 6 7 8C359 0.1U/6
8P4R-39
RN101
1 2 3 4 5 6 7 8
8P4R-39
RN103
1 2 3 4 5 6 7 8
8P4R-39
Title
Size Document Number Rev
2
Date: Sheet of
DDRB_DQ8_R [18,19,20] DDRB_DQ9_R [18,19,20] DQS1_B_R [18,19,20] DQS10_B_R [18,19,20]
DQS12_B_R [18,19,20] DDRB_MA4_R [12,19,20] DDRB_MA3_R [12,19,20] DDRB_DQ30_R [18,19,20]
DQS5_B_R [18,19,20] DDRB_DQ43_R [18,19,20] DDRB_DQ42_R [18,19,20] DDRB_DQ47_R [18,19,20]
DDRA_CS6_N_R [12] DDRB_DQ51_R [18,19,20] DDRA_CS7_N_R [12] DDRB_DQ56_R [18,19,20]
CB4_B_R [18,19,20] DDRB_MA1_R [12,19,20] CB0_B_R [18,19,20] CB5_B_R [18,19,20]
DDRB_DQ36_R [18,19,20] DDRB_DQ32_R [18,19,20] DDRB_BA1_R [12,19,20] CB6_B_R [18,19,20]
DDRB_MA2_R [12,19,20] DDRB_DQ31_R [18,19,20] DDRB_DQ27_R [18,19,20] DDRB_DQ26_R [18,19,20]
DDRB_MA6_R [12,19,20] DDRB_DQ28_R [18,19,20] DDRB_DQ29_R [18,19,20] DQS3_B_R [18,19,20]
DQS2_B_R [18,19,20] DDRB_DQ17_R [18,19,20] DDRB_DQ16_R [18,19,20] DDRB_DQ20_R [18,19,20]
DDRB_DQ35_R [18,19,20] DDRB_DQ44_R [18,19,20] DDRB_DQ40_R [18,19,20] DDRB_RAS_N_R [12,19,20]
DDRB_CS3_N_R [12,19] DDRB_CS2_N_R [12,19] DDRB_CS1_N_R [12,19] DDRB_CS0_N_R [12,19]
DQS15_B_R [18,19,20] DDRB_DQ53_R [18,19,20] DDRB_DQ52_R [18,19,20] DDRB_CS5_N_R [12,20]
GIGA-BYTE TECHNOLOGY CO., LTD.
DDR CHANNEL B TERMINATION
GA-8IPP533
21 58Tuesday, October 21, 2003
1
1.3
5
4
3
VCC3
VCC3
2
1
R251 10K/6
D D
U4A
P1_PA_AD[0..63][27,30,55]
SM Bus Address Setting
Bit
C C
B B
7 6 5 4
3 2 1
Value
'1' '1'
PA_GNT[5]
'0' PA_GNT[4] PB_GNT[5]
PB_GNT[4]
P1_PB_GNT5_N[23]
P1_PB_GNT5_N P1_PA_GNT4_N P1_PA_GNT5_N
R258 100K/6
R259 100K/6
R260 100K/6
P64H2 #1 SMBUS Strapping
Address = C2h
Determining PCI/PCI-X Bus Frequency
Hot Plug Exit ? PX_M66EN
Yes
A A
No
PX_133EN Don't Care
Don't Care Don't Care
Don't Care
0 1
5
Don't Care
0 1
Don't Care
Don't Care Don't Care
PX_PCIXCAP
Don't Care
0 0
Low
1 1
P1_PA_AD[0..63]
Bus Mode
PCI 33
PCI 33 PCI 66
PCI-X 66
PCI-X 100 PCI-X 133
4
P1_PA_AD0 P1_PA_AD1 P1_PA_AD2 P1_PA_AD3 P1_PA_AD4 P1_PA_AD5 P1_PA_AD6 P1_PA_AD7 P1_PA_AD8 P1_PA_AD9 P1_PA_AD10 P1_PA_AD11 P1_PA_AD12 P1_PA_AD13 P1_PA_AD14 P1_PA_AD15 P1_PA_AD16 P1_PA_AD17 P1_PA_AD18 P1_PA_AD19 P1_PA_AD20 P1_PA_AD21 P1_PA_AD22 P1_PA_AD23 P1_PA_AD24 P1_PA_AD25 P1_PA_AD26 P1_PA_AD27 P1_PA_AD28 P1_PA_AD29 P1_PA_AD30 P1_PA_AD31 P1_PA_AD32 P1_PA_AD33 P1_PA_AD34 P1_PA_AD35 P1_PA_AD36 P1_PA_AD37 P1_PA_AD38 P1_PA_AD39 P1_PA_AD40 P1_PA_AD41 P1_PA_AD42 P1_PA_AD43 P1_PA_AD44 P1_PA_AD45 P1_PA_AD46 P1_PA_AD47 P1_PA_AD48 P1_PA_AD49 P1_PA_AD50 P1_PA_AD51 P1_PA_AD52 P1_PA_AD53 P1_PA_AD54 P1_PA_AD55 P1_PA_AD56 P1_PA_AD57 P1_PA_AD58 P1_PA_AD59 P1_PA_AD60 P1_PA_AD61 P1_PA_AD62 P1_PA_AD63
AC22
V23
Y23 AA23 AC23 AD23
V24
W24
AB24
U19
U22
U23
T18
T19
T21
T22
N21
N22
M18 M20 M21 M23
L19
L20
L23
K18
K19
K21
K22
K24
J18
J20 V14 Y14
AA14 AC14 AD14
V15
W15 AA15 AB15 AD15
W16
Y16 AB16 AC16
Y17 AA17 AC17 AD17
W18 AA18 AB18 AD18
W19
Y19 AB19 AC19
V20
Y20 AA20 AC20 AD20
V21
PA_AD0 PA_AD1 PA_AD2 PA_AD3 PA_AD4 PA_AD5 PA_AD6 PA_AD7 PA_AD8 PA_AD9 PA_AD10 PA_AD11 PA_AD12 PA_AD13 PA_AD14 PA_AD15 PA_AD16 PA_AD17 PA_AD18 PA_AD19 PA_AD20 PA_AD21 PA_AD22 PA_AD23 PA_AD24 PA_AD25 PA_AD26 PA_AD27 PA_AD28 PA_AD29 PA_AD30 PA_AD31 PA_AD32 PA_AD33 PA_AD34 PA_AD35 PA_AD36 PA_AD37 PA_AD38 PA_AD39 PA_AD40 PA_AD41 PA_AD42 PA_AD43 PA_AD44 PA_AD45 PA_AD46 PA_AD47 PA_AD48 PA_AD49 PA_AD50 PA_AD51 PA_AD52 PA_AD53 PA_AD54 PA_AD55 PA_AD56 PA_AD57 PA_AD58 PA_AD59 PA_AD60 PA_AD61 PA_AD62 PA_AD63
P64H2
P64H2 #1_CHA
3
CLKENB/PA_GNT3_N BUSENB/PA_GNT4_N
RESETA_N/PA_GNT5_N
PCIXCAP1B/PA_REQ3_N
M66ENB/PA_REQ4_N
PRSNT1B/PA_REQ5_N
PRSNT2B/PA_IRQ8
FAULTB_N/PA_IRQ9
SWITCHB/PA_IRQ10
M66ENA/PA_IRQ11 PRSNT1A/PA_IRQ12 PRSNT2A/PA_IRQ13
FAULTA_N/PA_IRQ14
SWITCHA/PA_IRQ15
PA_PCIXCAP
PA_M66EN
PA_REQ64_N
PA_ACK64_N
PA_133EN
PA_GNT0_N PA_GNT1_N PA_GNT2_N
PA_REQ0_N PA_REQ1_N PA_REQ2_N
PA_PAR64
PA_PAR
PA_PLOCK_N
PA_STOP_N
PA_PERR_N PA_SERR_N
PA_IRDY_N
PA_TRDY_N
PA_FRAME_N
PA_DEVSEL_N
PA_CBE0_N PA_CBE1_N PA_CBE2_N PA_CBE3_N PA_CBE4_N PA_CBE5_N PA_CBE6_N PA_CBE7_N
PA_PCLKI
PA_PCLK0 PA_PCLK1 PA_PCLK2 PA_PCLK3 PA_PCLK4 PA_PCLK5 PA_PCLK6
PA_PCIRST_N
PA_IRQ0 PA_IRQ1 PA_IRQ2 PA_IRQ3 PA_IRQ4 PA_IRQ5 PA_IRQ6 PA_IRQ7
P22 U20 Y22 AB22 E23
G19 G22 F18 F20 F23 E22
G18 G21 G24 F19 F21 F24
W21 R18 R23 R24 R21 R20 P23 P20 N18 P19
AA24 T24 N19 L22 AA21 AB21 AD21 W22
V17 J21
J23 J24 H19 H20 H22 H23
E24 B7
D7 A6 B6 C6 D6 E6 F6 A5 B5 C5 D5 E5 F5 E4 F4
P1_PA_133EN
P1_PA_GNT0_N P1_PA_GNT1_N P1_PA_GNT2_N P1_PA_GNT3_N P1_PA_GNT4_N P1_PA_GNT5_N
P1_PA_REQ0_N P1_PA_REQ1_N P1_PA_REQ2_N P1_PA_REQ3_N P1_PA_REQ4_N P1_PA_REQ5_N
P1_PA_PAR64 P1_PA_PAR P1_PA_PLOCK_N P1_PA_STOP_N P1_PA_PERR_N P1_PA_SERR_N P1_PA_IRDY_N P1_PA_TRDY_N P1_PA_FRAME_N P1_PA_DEVSEL_N
P1_PA_CBE0_N P1_PA_CBE1_N P1_PA_CBE2_N P1_PA_CBE3_N P1_PA_CBE4_N P1_PA_CBE5_N P1_PA_CBE6_N P1_PA_CBE7_N
P1_PA_PCLKI P1_PA_PCLK0_L
P1_PA_PCLK1_L P1_PA_PCLK2_L P1_PA_PCLK3_L
P1_PA_PCLK6 P1_PA_PCIRST_N P1_PA_IRQ0
P1_PA_IRQ1 P1_PA_IRQ2 P1_PA_IRQ3 P1_PA_IRQ4 P1_PA_IRQ5 P1_PA_IRQ6 P1_PA_IRQ7 P1_PA_IRQ8 P1_PA_IRQ9 P1_PA_IRQ10 P1_PA_IRQ11 P1_PA_IRQ12 P1_PA_IRQ13 P1_PA_IRQ14 P1_PA_IRQ15
R1504
8.2K/6/X
THIS CHANNEL RUN PCIX 66MHZ
R1345 8.2K/6 R1346 8.2K/6
P1_PA_PCIXCAP P1_HA_M66ENA P1_PA_REQ64_N P1_PA_ACK64_N
P1_PA_GNT0_N [27] P1_PA_GNT1_N [27] P1_PA_GNT2_N [30] P1_PA_GNT3_N [27]
P1_PA_REQ0_N [26,27] P1_PA_REQ1_N [26,27] P1_PA_REQ2_N [26,30] P1_PA_REQ3_N [26,27] P1_PA_REQ4_N [26] P1_PA_REQ5_N [26]
P1_PA_PAR64 [27,30] P1_PA_PAR [27,30] P1_PA_PLOCK_N [27] P1_PA_STOP_N [27,30] P1_PA_PERR_N [27,30] P1_PA_SERR_N [27,30] P1_PA_IRDY_N [27,30] P1_PA_TRDY_N [27,30] P1_PA_FRAME_N [27,30] P1_PA_DEVSEL_N [27,30]
P1_PA_CBE0_N [27,30] P1_PA_CBE1_N [27,30] P1_PA_CBE2_N [27,30] P1_PA_CBE3_N [27,30] P1_PA_CBE4_N [27,30] P1_PA_CBE5_N [27,30] P1_PA_CBE6_N [27,30] P1_PA_CBE7_N [27,30]
R825 33/6 R829 33/6/X R1499 33/6 R1500 33/6/X
R283 33/6
P1_PA_PCIRST_N [27,30] P1_PA_IRQ0 [26,27]
P1_PA_IRQ1 [26,27] P1_PA_IRQ2 [26,55] P1_PA_IRQ3 [26,55] P1_PA_IRQ4 [26,27] P1_PA_IRQ5 [26,27] P1_PA_IRQ6 [26] P1_PA_IRQ7 [26] P1_PA_IRQ8 [26] P1_PA_IRQ9 [26] P1_PA_IRQ10 [26] P1_PA_IRQ11 [26] P1_PA_IRQ12 [26] P1_PA_IRQ13 [26] P1_PA_IRQ14 [26] P1_PA_IRQ15 [26]
2
VCC3
R262
100K/6
P1_PA_PCIXCAP [27,30]
P1_PA_REQ64_N [27,30] P1_PA_ACK64_N [27,30]
P1_PA_PCLK0 P1_PA_PCLK1 P1_PA_PCLK2 P1_PA_PCLK3
Title
Size Document Number Rev
Date: Sheet of
D58
2 3
BAT54/SOT23
P1_PA_GNT3_N
P1_PA_PCLK0 [27] P1_PA_PCLK1 [27] P1_PA_PCLK2 [30] P1_PA_PCLK3 [27]
P1_HA_M66ENA2 [27,30]
R1287 8.2K/6
GIGA-BYTE TECHNOLOGY CO., LTD.
P64H2 PCIX CHANNEL A
GA-8IPP533
22 58Tuesday, October 21, 2003
1
C370 20P/6
1.3
5
D D
P1_PB_AD[0..63][26,28,31]
C C
B B
P1_PB_AD[0..63]
4
P1_PB_AD0 P1_PB_AD1 P1_PB_AD2 P1_PB_AD3 P1_PB_AD4 P1_PB_AD5 P1_PB_AD6 P1_PB_AD7 P1_PB_AD8 P1_PB_AD9 P1_PB_AD10 P1_PB_AD11 P1_PB_AD12 P1_PB_AD13 P1_PB_AD14 P1_PB_AD15 P1_PB_AD16 P1_PB_AD17 P1_PB_AD18 P1_PB_AD19 P1_PB_AD20 P1_PB_AD21 P1_PB_AD22 P1_PB_AD23 P1_PB_AD24 P1_PB_AD25 P1_PB_AD26 P1_PB_AD27 P1_PB_AD28 P1_PB_AD29 P1_PB_AD30 P1_PB_AD31 P1_PB_AD32 P1_PB_AD33 P1_PB_AD34 P1_PB_AD35 P1_PB_AD36 P1_PB_AD37 P1_PB_AD38 P1_PB_AD39 P1_PB_AD40 P1_PB_AD41 P1_PB_AD42 P1_PB_AD43 P1_PB_AD44 P1_PB_AD45 P1_PB_AD46 P1_PB_AD47 P1_PB_AD48 P1_PB_AD49 P1_PB_AD50 P1_PB_AD51 P1_PB_AD52 P1_PB_AD53 P1_PB_AD54 P1_PB_AD55 P1_PB_AD56 P1_PB_AD57 P1_PB_AD58 P1_PB_AD59 P1_PB_AD60 P1_PB_AD61 P1_PB_AD62 P1_PB_AD63
W3 AA3 AB3 AD3
W4 AB4
AC4 AA5
AD5
W6 AA6 AB6 AD6
W10
Y10
AB10 AC10
V11 Y11
AA11 AC11
V12
W12 AA12 AB12
W13
Y13 AB13 AC13
M6 M5 M3 M2
W1
AB1
Y4
Y5
V6
L2 L1
N7 N6 N4 N3 P7 P5 P4 P2 P1 R6 R5 R3 R2 T7 T6 T4 T3 T1 U7 U5 U4 U2 U1
Y1
U4B
PB_AD0 PB_AD1 PB_AD2 PB_AD3 PB_AD4 PB_AD5 PB_AD6 PB_AD7 PB_AD8 PB_AD9 PB_AD10 PB_AD11 PB_AD12 PB_AD13 PB_AD14 PB_AD15 PB_AD16 PB_AD17 PB_AD18 PB_AD19 PB_AD20 PB_AD21 PB_AD22 PB_AD23 PB_AD24 PB_AD25 PB_AD26 PB_AD27 PB_AD28 PB_AD29 PB_AD30 PB_AD31 PB_AD32 PB_AD33 PB_AD34 PB_AD35 PB_AD36 PB_AD37 PB_AD38 PB_AD39 PB_AD40 PB_AD41 PB_AD42 PB_AD43 PB_AD44 PB_AD45 PB_AD46 PB_AD47 PB_AD48 PB_AD49 PB_AD50 PB_AD51 PB_AD52 PB_AD53 PB_AD54 PB_AD55 PB_AD56 PB_AD57 PB_AD58 PB_AD59 PB_AD60 PB_AD61 PB_AD62 PB_AD63
P64H2
3
PB_PCIXCAP
PB_REQ64_N
PB_ACK64_N
PB_GNT0_N PB_GNT1_N
PB_GNT2_N PB_GNT3_N_CLKENB PB_GNT4_N_BUSENB
PB_GNT5_N_RESETA_N
PB_REQ0_N
PB_REQ1_N
PB_REQ2_N
PCIXCAP1B/PB_REQ3_N
M66ENB/PB_REQ4_N
PRSNT1B/PB_REQ5_N
PB_PLOCK_N
PB_STOP_N
PB_PERR_N PB_SERR_N
PB_TRDY_N
PB_FRAME_N
PB_DEVSEL_N
PB_CBE0_N PB_CBE1_N PB_CBE2_N PB_CBE3_N PB_CBE4_N PB_CBE5_N PB_CBE6_N PB_CBE7_N
PB_PCIRST_N
PB_IRQ8_PRSNT2B
PB_IRQ9_FAULTB_N
PB_IRQ10_SWITCHB
PB_IRQ11_M66ENA PB_IRQ12_PRSNT1A PB_IRQ13_PRSNT2A
PB_IRQ14_FAULTA_N
PB_IRQ15_SWITCHA
PB_M66EN
PB_133EN
PB_PAR64
PB_PAR
PB_IRDY_N
PB_PCLKI
PB_PCLK0 PB_PCLK1 PB_PCLK2 PB_PCLK3 PB_PCLK4 PB_PCLK5 PB_PCLK6
PB_IRQ0 PB_IRQ1 PB_IRQ2 PB_IRQ3 PB_IRQ4 PB_IRQ5 PB_IRQ6 PB_IRQ7
2
VCC3
THIS CHANNEL RUN PCIX 100MHZ
R1830
R257
10K/6
10K/6
P1_PB_PCIXCAP
W9
P1_PB_M66ENA
AC5
P1_PB_REQ64_N
AD2
P1_PB_ACK64_N
V3
P1_PB_133EN
H6
P1_PB_GNT0_N
J2
P1_PB_GNT1_N
J5
P1_PB_GNT2_N
H1
P1_PB_GNT3_N
H3
P1_PB_GNT4_N
H5
P1_PB_GNT5_N
G4
P1_PB_REQ0_N
K7
P1_PB_REQ1_N
J3
P1_PB_REQ2_N
J6
P1_PB_REQ3_N
H2
P1_PB_REQ4_N
H4
P1_PB_REQ5_N
G3
P1_PB_PAR64
AC1
P1_PB_PAR
AB7
P1_PB_PLOCK_N
Y8
P1_PB_STOP_N
AA8
P1_PB_PERR_N
Y7
P1_PB_SERR_N
W7
P1_PB_IRDY_N
AA9
P1_PB_TRDY_N
AD8
P1_PB_FRAME_N
AB9
P1_PB_DEVSEL_N
AC8
P1_PB_CBE0_N
V5
P1_PB_CBE1_N
AC7
P1_PB_CBE2_N
AD9
P1_PB_CBE3_N
AD11
P1_PB_CBE4_N
V2
P1_PB_CBE5_N
Y2
P1_PB_CBE6_N
AA2
P1_PB_CBE7_N
AC2
P1_PB_PCLKI
V8
P1_PB_PCLK0_L
L4
P1_PB_PCLK1_L P1_PB_PCLK1
L5
P1_PB_PCLK2_L
L7
P1_PB_PCLK3_L
K1 K3
P1_PB_PCLK5
K4
P1_PB_PCLK6
K6
P1_PB_PCIRST_N
G2
P1_PB_IRQ0
B3
P1_PB_IRQ1
C3
P1_PB_IRQ2
D3
P1_PB_IRQ3
E3
P1_PB_IRQ4
F3
P1_PB_IRQ5
A2
P1_PB_IRQ6
B2
P1_PB_IRQ7
C2
P1_PB_IRQ8
D2
P1_PB_IRQ9
E2
P1_PB_IRQ10
F2
P1_PB_IRQ11
B1
P1_PB_IRQ12
C1
P1_PB_IRQ13
D1
P1_PB_IRQ14
E1
P1_PB_IRQ15
F1
R261
8.2K/6
P1_PB_REQ64_N [26,28,31] P1_PB_ACK64_N [26,28,31]
P1_PB_GNT0_N [31]
P1_PB_GNT5_N [22] P1_PB_REQ0_N [26,31]
P1_PB_REQ1_N [26] P1_PB_REQ2_N [26,28] P1_PB_REQ3_N [26,28] P1_PB_REQ4_N [26] P1_PB_REQ5_N [26]
P1_PB_PAR64 [26,28,31] P1_PB_PAR [26,28,31] P1_PB_PLOCK_N [26,28,31] P1_PB_STOP_N [26,28,31] P1_PB_PERR_N [26,28,31] P1_PB_SERR_N [26,28,31] P1_PB_IRDY_N [26,28,31] P1_PB_TRDY_N [26,28,31] P1_PB_FRAME_N [26,28,31] P1_PB_DEVSEL_N [26,28,31]
P1_PB_CBE0_N [28,31] P1_PB_CBE1_N [28,31] P1_PB_CBE2_N [28,31] P1_PB_CBE3_N [28,31] P1_PB_CBE4_N [26,28,31] P1_PB_CBE5_N [26,28,31] P1_PB_CBE6_N [26,28,31] P1_PB_CBE7_N [26,28,31]
R826 33/6 R827 33/6/X R1501 33/6 R1502 33/6
R284 33/6
P1_PB_PCIRST_N [28,31] P1_PB_IRQ0 [26,31]
P1_PB_IRQ1 [26,31] P1_PB_IRQ2 [26,28] P1_PB_IRQ3 [26,28] P1_PB_IRQ4 [26,28] P1_PB_IRQ5 [26,28] P1_PB_IRQ6 [26,28] P1_PB_IRQ7 [26,28] P1_PB_IRQ8 [26,28] P1_PB_IRQ9 [26,28] P1_PB_IRQ10 [26] P1_PB_IRQ11 [26] P1_PB_IRQ12 [26] P1_PB_IRQ13 [26] P1_PB_IRQ14 [26] P1_PB_IRQ15 [26]
R1289 8.2K/6
R1425
8.2K/6/X
TP300
VCC3
R1449 100K/6
P1_PB_PCLK0 P1_PB_PCLK2
P1_PB_PCLK3
P1_PB_PCIXCAP
D59
2 3
BAT54/SOT23
D56
BAT54/SOT23
2 3
R263 8.2K/6
R1505
8.2K/6/X
P1_PB_PCLK0 [31] P1_PB_PCLK2 [28]
P1_PB_PCLK3 [28]
P1_PB_PCIXCAP [28]
P1_HB_M66ENB1 [28]
P1_HB_M66ENA [31]
VCC3
P1_PB_GNT2_N P1_PB_GNT3_N
1
P1_PB_GNT2_N [28] P1_PB_GNT3_N [28]
C1611 10P/6/X
C1370 10P/6/X
P64H2 #1_CHB
A A
Title
Size Document Number Rev
5
4
3
2
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
P64H2 PCIX CHANNEL B
GA-8IPP533
23 58Tuesday, October 21, 2003
1
1.3
5
D D
VCC3
R268 8.2K/6 R269 8.2K/6
C C
R1312 8.2K/6
C1289 10P/6/X
RN221
1 2 3 4 5 6 7 8
8P4R-8.2K
R281 8.2K/6 R282 8.2K/6
B B
A A
P1_RESEREVD_3 P1_TEST_N P1_RASERR_N
P1_CLK66
P1_HPB_SLOT2 P1_HPA_SLOT2 P1_HPA_SLOT1 P1_HPA_SLOT0
P1_HPB_SLOT1 P1_HPB_SLOT0
P1_HI[0..15][11]
VCC3
VCC3
ICH3_SMBCLK[11,15,16,19,20,37,46] ICH3_SMBDATA[11,15,16,19,20,37,46]
4
P1_PUSTRBS[11] P1_PUSTRBF[11]
P1_PSTRBS[11] P1_PSTRBF[11]
P1_HI[0..15]
P1_HI16[11] P1_HI17[11] P1_HI18[11]
P1_HI20[11] P1_HI21[11]
P1_CLK66[46]
R271 8.2K/6 R272 8.2K/6
P64H2_PWROK[48] PCIRST_2_N[36]
ICH3_PIRQA_N[35,36]
R273 8.2K/6 R274 8.2K/6 R275 8.2K/6
TP301
TP63 TP64
TP65
P1_PUSTRBS P1_PUSTRBF
P1_PSTRBS P1_PSTRBF
P1_HI0 P1_HI1 P1_HI2 P1_HI3 P1_HI4 P1_HI5 P1_HI6 P1_HI7 P1_HI8
P1_HI9 P1_HI10 P1_HI11 P1_HI12 P1_HI13 P1_HI14 P1_HI15 P1_HI16 P1_HI17 P1_HI18 P1_HI19 P1_HI20 P1_HI21
P1_CLK66
P1_CK200_N P1_CK200
P64H2_PWROK PCIRST_2_N P1_RASERR_N P1_TEST_N ICH3_PIRQA_N
P1_RESEREVD_3
R1775 47/6
P1_APICCLK P1_APICD0 P1_APICD1
C14 E14 A10 C10
E10 B11 D11 E12 B13 D13 A14 B15 D15 A16
C16 G11 G13 G12
C12
E16
E19
E18
E21
E20
D17
B17
F17
C18
D18
A8 C8 E8 B9 D9
G8
H7
F7
G6
C4
A3 B4 A4
U4C
PUSTRBS PUSTRBF PSTRBS PSTRBF
HI0 HI1 HI2 HI3 HI4 HI5 HI6 HI7 HI8 HI9 HI10 HI11 HI12 HI13 HI14 HI15 HI16 HI17 HI18 HI19 HI20 HI21
CLK66
CK200_N CK200
BPCLK100 BPCLK133
PWR_OK RSTIN_N RASERR_N TEST_N BTINTR_N
TP0
SCLK SDATA
APIC_CLK APICD1 APICD0
P64H2
3
P1_VSWING
G10
HI_VSWING
HI_VREF
HI_RCOMP
VCC5REF1 VCC5REF2
HPA_SORR_N
HPA_SOR_N/RESETB_N
HPA_SOLR/PWRENB
HPA_SOL/AMLEDA HPA_SOD/PWRENA
HPA_SOC/GNLEDA HPA_SLOT0/PCIXCAP2B HPA_SLOT1/PCIXCAP2A HPA_SLOT2/PCIXCAP1A
HPA_SIL_N/CLKENA
HPA_SID/AMLEDB HPA_SIC/GNLEDB
HPB_SORR_N
RESETB_N/HPB_SOR_N
PWRENB/HPB_SOLR
AMLEDA/HPB_SOL
PWRENA/HPB_SOD
GNLEDA/HPB_SOC PCIXCAP2B/HPB_SLOT0 PCIXCAP2A/HPB_SLOT1 PCIXCAP1A/HPB_SLOT2
CLKENA/HPB_SIL_N
AMLEDB/HPB_SID GNLEDB/HPB_SIC
F11 F9
AD24 G1
A18 B18 C19 D19 B19 A19
P1_HPA_SLOT0
A20
P1_HPA_SLOT1
C20
P1_HPA_SLOT2
D20 C21 D21 B21
A22 A21 B22 C22 C24 A24
P1_HPB_SLOT0
B23
P1_HPB_SLOT1
C23
P1_HPB_SLOT2
D23 D24 B24 A23
P1_VREF
P1_RCOMP
VCC
C1285
0.1U/6
0.8V
0.35V
R276
8.2K/6
R1313
8.2K/6
TP67 TP69 TP71 TP73 TP75 TP77
TP79 TP80 TP82
2
TP66 TP68 TP70 TP72 TP74 TP76
TP78 TP81
C371
0.01U/6
C373
0.01U/6
R264 732/6/1
R265 332/6/1
R266 255/6/1
VCC1_8
C372
0.1U/6
C374
0.1U/6
SC417 22U/12
VCC1_8
SC416 22U/12
VCC1_8
R270
78.7/6/1
1
REV:0.5 ADD SC416,SC417 TO FILTER VCC1_8 NOISE
Title
Size Document Number Rev
5
4
3
2
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
P64H2 HUB LINK 2.0
GA-8IPP533
24 58Tuesday, October 21, 2003
1
1.3
5
4
3
2
1
D D
VCC1_8 VCC3
C C
B B
U4D
G17
VCC-CORE_1.8_1
J7
VCC-CORE_1.8_2
K10
VCC-CORE_1.8_3
K11
VCC-CORE_1.8_4
K14
VCC-CORE_1.8_5
K15
VCC-CORE_1.8_6
L10
VCC-CORE_1.8_7
L11
VCC-CORE_1.8_8
L14
VCC-CORE_1.8_9
L15
VCC-CORE_1.8_10
M12
VCC-CORE_1.8_11
M13
VCC-CORE_1.8_12
N12
VCC-CORE_1.8_13
N13
VCC-CORE_1.8_14
P10
VCC-CORE_1.8_15
P11
VCC-CORE_1.8_16
P14
VCC-CORE_1.8_17
P15
VCC-CORE_1.8_18
R10
VCC-CORE_1.8_19
R11
VCC-CORE_1.8_20
R14
VCC-CORE_1.8_21
R15
VCC-CORE_1.8_22
V9
VCC-CORE_1.8_23
V18
VCC-CORE_1.8_24
F8
VCC-HUB_1.8_1
F10
VCC-HUB_1.8_2
F12
VCC-HUB_1.8_3
F13
VCC-HUB_1.8_4
F15
VCC-HUB_1.8_5
F16
VCC-HUB_1.8_6
G7
VCC-HUB_1.8_7
G9
VCC-HUB_1.8_8
G14
VCC-HUB_1.8_9
G15
VCC-HUB_1.8_10
G16
VCC-HUB_1.8_11
H12
VCC-HUB_1.8_12
H13
VCC-HUB_1.8_13
J12
VCC-HUB_1.8_14
J13
VCC-HUB_1.8_15
U21
VSS_1
A7
VSS_2
A9
VSS_3
A13
VSS_4
A15
VSS_5
A17
VSS_6
AA1
VSS_7
AA4
VSS_8
AA7
VSS_9
AA10
VSS_10
AA13 AA16
VSS_11 VSS_12
VCC-PCI_3.3_1 VCC-PCI_3.3_2 VCC-PCI_3.3_3 VCC-PCI_3.3_4 VCC-PCI_3.3_5 VCC-PCI_3.3_6 VCC-PCI_3.3_7 VCC-PCI_3.3_8
VCC-PCI_3.3_9 VCC-PCI_3.3_10 VCC-PCI_3.3_11 VCC-PCI_3.3_12 VCC-PCI_3.3_13 VCC-PCI_3.3_14 VCC-PCI_3.3_15 VCC-PCI_3.3_16 VCC-PCI_3.3_17 VCC-PCI_3.3_18 VCC-PCI_3.3_19 VCC-PCI_3.3_20 VCC-PCI_3.3_21 VCC-PCI_3.3_22 VCC-PCI_3.3_23 VCC-PCI_3.3_24 VCC-PCI_3.3_25 VCC-PCI_3.3_26 VCC-PCI_3.3_27 VCC-PCI_3.3_28 VCC-PCI_3.3_29 VCC-PCI_3.3_30 VCC-PCI_3.3_31 VCC-PCI_3.3_32 VCC-PCI_3.3_33 VCC-PCI_3.3_34 VCC-PCI_3.3_35 VCC-PCI_3.3_36 VCC-PCI_3.3_37 VCC-PCI_3.3_38 VCC-PCI_3.3_39 VCC-PCI_3.3_40 VCC-PCI_3.3_41 VCC-PCI_3.3_42 VCC-PCI_3.3_43 VCC-PCI_3.3_44 VCC-PCI_3.3_45 VCC-PCI_3.3_46 VCC-PCI_3.3_47 VCC-PCI_3.3_48 VCC-PCI_3.3_49
VSS_22 VSS_21 VSS_20 VSS_19 VSS_18 VSS_17 VSS_16 VSS_15 VSS_14 VSS_13
H8 H9 H16 H17 H18 J8 J9 J16 J17 J19 L6 L18 M7 M8 M9 M16 M17 M19 N8 N9 N16 N17 P6 P18 R7 R19 T8 T9 T12 T13 T16 T17 U6 U8 U9 U12 U13 U16 U17 U18 V7 V10 V13 V16 V19 W8 W11 W14 W17
AB23 AB20 AB17 AB14 AB11 AB8 AB5 AB2 AA22 AA19
P64H2
AC3 AC6
AC9 AC12 AC15 AC18 AC21 AC24
AD1
AD4
AD7 AD10 AD16 AD19 AD22
B10
B12
B14
B16
B20
C11
C13
C15
C17
D10
D12
D14
D16
D22
E11
E13
E15
E17
F14
F22
G5 G20 G23
H10 H11 H14 H15 H21 H24
J10 J11 J14 J15 J22
K12 K13 K16 K17 K20 K23
B8
C7 C9
D4 D8
E7 E9
K2 K5 K8 K9
L3
J1 J4
U4E
VSS_23 VSS_24 VSS_25 VSS_26 VSS_27 VSS_28 VSS_29 VSS_30 VSS_31 VSS_32 VSS_33 VSS_34 VSS_35 VSS_36 VSS_37 VSS_38 VSS_39 VSS_40 VSS_41 VSS_42 VSS_43 VSS_44 VSS_45 VSS_46 VSS_47 VSS_48 VSS_49 VSS_50 VSS_51 VSS_52 VSS_53 VSS_54 VSS_55 VSS_56 VSS_57 VSS_58 VSS_59 VSS_60 VSS_61 VSS_62 VSS_63 VSS_64 VSS_65 VSS_66 VSS_67 VSS_68 VSS_69 VSS_70 VSS_71 VSS_72 VSS_73 VSS_74 VSS_75 VSS_76 VSS_77 VSS_78 VSS_79 VSS_80 VSS_81 VSS_82 VSS_83 VSS_84 VSS_85 VSS_86 VSS_87 VSS_88 VSS_89 VSS_90 VSS_91
P64H2
VSS_92 VSS_93 VSS_94 VSS_95 VSS_96 VSS_97 VSS_98
VSS_99 VSS_100 VSS_101 VSS_102 VSS_103 VSS_104 VSS_105 VSS_106 VSS_107 VSS_108 VSS_109 VSS_110 VSS_111 VSS_112 VSS_113 VSS_114 VSS_115 VSS_116 VSS_117 VSS_118 VSS_119 VSS_120 VSS_121 VSS_122 VSS_123 VSS_124 VSS_125 VSS_126 VSS_127 VSS_128 VSS_129 VSS_130 VSS_131 VSS_132 VSS_133 VSS_134 VSS_135 VSS_136 VSS_137 VSS_138 VSS_139 VSS_140 VSS_141 VSS_142 VSS_143 VSS_144 VSS_145 VSS_146 VSS_147 VSS_148 VSS_149 VSS_150 VSS_151 VSS_152 VSS_153 VSS_154 VSS_155 VSS_156 VSS_157 VSS_158 VSS_159 VSS_160
L8 L9 L12 L13 L16 L17 L21 L24 M4 M10 M11 M14 M15 M22 N2 N5 N10 N11 N14 N15 N20 N23 P3 P8 P9 P12 P13 P16 P17 P21 P24 R1 R4 R8 R9 R12 R13 R16 R17 R22 T2 T5 T10 T11 T14 T15 T20 T23 U3 U10 U11 U14 U15 U24 V1 V4 V22 W2 W5 W20 W23 Y3 Y6 Y9 Y12 Y15 Y18 Y21 Y24
REV:1.2 CONNECT EC110 TO VCC1_8
REV:1.2 CHANGE THESE CAP TO 100U FROM 4.7U
C375 IS ON
VCC1_8 VCC3
SOLDER SIDE
C375 100U/1210
C378 100U/1210
C381 1U/6
C384 1U/6
C387 0.1U/6
C390 0.1U/6
C393 0.1U/6
C396 0.1U/6
C399 0.1U/6
C401 0.1U/6
1 2
EC110 560U/4V/8*10.5
C376 100U/1210
C379 100U/1210
C382 1U/6
C385 1U/6
C388 1U/6
C391 1U/6
C394 1U/6
C397 1U/6
C400 0.1U/6
C402 0.1U/6
C403 0.1U/6
C404 0.1U/6
C405 0.1U/6
C406 0.1U/6
C407 0.1U/6
C408 0.1U/6
C409 0.1U/6
C410 0.1U/6
SC411 0.1U/6
C412 0.1U/6
A A
Title
Size Document Number Rev
5
4
3
2
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
P64H2 POWER AND GND
GA-8IPP533
25 58Tuesday, October 21, 2003
1
1.3
5
4
3
2
1
RN112
P1_PA_REQ3_N[22,27] P1_PA_IRQ10[22] P1_PA_IRQ9[22]
D D
C C
B B
P1_PA_IRQ8[22]
P1_PA_IRQ4[22,27]
P1_PA_REQ1_N[22,27] P1_PA_REQ4_N[22]
P1_PA_IRQ13[22]
P1_PA_IRQ3[22,55] P1_PA_IRQ2[22,55] P1_PA_IRQ1[22,27] P1_PA_IRQ0[22,27]
P1_PA_IRQ15[22] P1_PA_IRQ14[22] P1_PA_IRQ11[22] P1_PA_IRQ12[22]
P1_PA_REQ5_N[22] P1_PA_REQ0_N[22,27]
P1_PA_REQ2_N[22,30] P1_PA_IRQ5[22,27] P1_PA_IRQ7[22] P1_PA_IRQ6[22]
1 2 3 4 5 6 7 8
8P4R-8.2K
RN116
8P4R-8.2K
RN119
1 2 3 4 5 6 7 8
8P4R-8.2K
RN220
1 2 3 4 5 6 7 8
8P4R-8.2K
RN123
1 2 3 4 5 6 7 8
8P4R-8.2K
RN136
1 2 3 4 5 6 7 8
8P4R-8.2K
VCC3
P1_PB_AD57[23,28,31] P1_PB_AD56[23,28,31] P1_PB_AD39[23,28,31] P1_PB_AD43[23,28,31]
12 34 56 78
VCC3
P1_PB_AD[32..63][23,28,31]
P1_PB_AD47 P1_PB_AD51 P1_PB_AD52 P1_PB_AD54
P1_PB_AD34 P1_PB_AD38 P1_PB_AD40 P1_PB_AD42
P1_PB_CBE7_N[23,28,31] P1_PB_CBE5_N[23,28,31]
P1_PB_PAR64[23,28,31]
P1_PB_CBE6_N[23,28,31]
P1_PB_CBE4_N[23,28,31]
P1_PB_AD63
P1_PB_AD53
P1_PB_AD50 P1_PB_AD62
P1_PB_AD60 P1_PB_AD44 P1_PB_AD45 P1_PB_AD46
P1_PB_AD61 P1_PB_AD58
P1_PB_AD41
P1_PB_AD49 P1_PB_AD36 P1_PB_AD37
P1_PB_AD55 P1_PB_AD35 P1_PB_AD32 P1_PB_AD33
RN107
1 2 3 4 5 6 7 8
8P4R-8.2K
RN110
1 2 3 4 5 6 7 8
8P4R-8.2K
RN114
1 2 3 4 5 6 7 8
8P4R-8.2K
RN118
1 2 3 4 5 6 7 8
8P4R-8.2K
RN121
1 2 3 4 5 6 7 8
8P4R-8.2K
RN125
1 2 3 4 5 6 7 8
8P4R-8.2K
RN129
1 2 3 4 5 6 7 8
8P4R-8.2K
RN133
1 2 3 4 5 6 7 8
8P4R-8.2K
RN137
1 2 3 4 5 6 7 8
8P4R-8.2K
VCC3
RN108
P1_PB_REQ3_N[23,28] P1_PB_IRQ4[23,28] P1_PB_IRQ8[23,28] P1_PB_IRQ12[23]
P1_PB_IRQ7[23,28] P1_PB_IRQ11[23] P1_PB_IRQ3[23,28] P1_PB_IRQ6[23,28]
P1_PB_IRQ2[23,28] P1_PB_IRQ5[23,28] P1_PB_IRQ1[23,31] P1_PB_IRQ0[23,31]
P1_PB_IRQ10[23] P1_PB_IRQ14[23] P1_PB_IRQ9[23,28] P1_PB_IRQ13[23]
P1_PB_IRQ15[23]
P1_PB_DEVSEL_N[23,28,31]
P1_PB_PAR[23,28,31]
P1_PB_PERR_N[23,28,31] P1_PB_IRDY_N[23,28,31] P1_PB_TRDY_N[23,28,31] P1_PB_REQ0_N[23,31]
P1_PB_SERR_N[23,28,31] P1_PB_STOP_N[23,28,31] P1_PB_FRAME_N[23,28,31] P1_PB_PLOCK_N[23,28,31]
P1_PB_REQ64_N[23,28,31] P1_PB_ACK64_N[23,28,31] P1_PB_AD59[23,28,31] P1_PB_AD48[23,28,31]
P1_PB_REQ1_N[23] P1_PB_REQ2_N[23,28] P1_PB_REQ4_N[23] P1_PB_REQ5_N[23]
1 2 3 4 5 6 7 8
8P4R-8.2K
RN111
1 2 3 4 5 6 7 8
8P4R-8.2K
RN115
1 2 3 4 5 6 7 8
8P4R-8.2K
RN219
1 2 3 4 5 6 7 8
8P4R-8.2K
R828 8.2K/6
R1424 8.2k/6
R285 8.2K/6/X
RN122
1 2 3 4 5 6 7 8
8P4R-8.2K
RN126
1 2 3 4 5 6 7 8
8P4R-8.2K
RN130
1 2 3 4 5 6 7 8
8P4R-8.2K
RN134
1 2 3 4 5 6 7 8
8P4R-8.2K
VCC3
VCC3
A A
P64H2 #1 PCI-X BUS A Pull-Up
5
4
3
P64H2 #1 PCI-X BUS B Pull-Up
Title
Size Document Number Rev
2
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
PCIX PULL UP
GA-8IPP533
1
26 58Tuesday, October 21, 2003
1.3
5
4
3
2
1
PCI-X SLOT 1 (P64H2 #1,PCI BUS A)
VCC3 +12VVCC-12V
PCI1
B1
D D
P1_PA_PCLK0[22]
C1658 10P/6/X
C C
P1_PA_PCIXCAP[22,30]
B B
A A
5
R1448
0/6
P1_HA_M66ENA2[22,30]
P1_PA_PCLK3[22] P1_PA_PCLK1[22]
P1_PA_IRQ1[22,26] SCSI_IRQB[30,55]
P1_PA_IRQ5[22,26]
P1_PA_REQ3_N[22,26]
P1_PA_REQ1_N[22,26]
P1_PA_REQ0_N[22,26]
P1_PA_CBE3_N[22,30]
P1_PA_CBE2_N[22,30] P1_PA_IRDY_N[22,30]
P1_PA_DEVSEL_N[22,30]
P1_PA_PLOCK_N[22] P1_PA_PERR_N[22,30]
P1_PA_SERR_N[22,30] P1_PA_CBE1_N[22,30]
C1369
0.01U/6
P1_PA_ACK64_N[22,30]
P1_PA_CBE6_N[22,30] P1_PA_CBE4_N[22,30]
P1_PA_PCLK3 P1_PA_PCLK1
P1_PA_IRQ1
SCSI_IRQB P1_PA_IRQ5
P1_PA_REQ3_N
P1_PA_REQ1_N
P1_PA_REQ0_N P1_PA_AD31
P1_PA_AD29 P1_PA_AD27
P1_PA_AD25 P1_PA_CBE3_N
P1_PA_AD23 P1_PA_AD21
P1_PA_AD19 P1_PA_AD17
P1_PA_CBE2_N P1_PA_IRDY_N P1_PA_DEVSEL_N P1_PA_PLOCK_N
P1_PA_PERR_N P1_PA_SERR_N P1_PA_CBE1_N
P1_PA_AD14 P1_PA_AD12
P1_PA_AD10 P1_HA_M66ENA2
P1_PA_AD8 P1_PA_AD7
P1_PA_AD5 P1_PA_AD3
P1_PA_AD1 P1_PA_ACK64_N
P1_PA_CBE6_N P1_PA_CBE4_N
P1_PA_AD63 P1_PA_AD61
P1_PA_AD59 P1_PA_AD57
P1_PA_AD55 P1_PA_AD53
P1_PA_AD51 P1_PA_AD49
P1_PA_AD47 P1_PA_AD45
P1_PA_AD43 P1_PA_AD41
P1_PA_AD39 P1_PA_AD37
P1_PA_AD35 P1_PA_AD33
4
-12V
B2
TCK
B3
GND
B4
TDO
B5
+5V
B6
+5V
B7
P64IRQ1
B8
P64IRQ3
B9
PRSNT1-
B10
RSV
B11
PRSNT2-
B14
RSV
B15
GND
B16
CLK
B17
GND
B18
REQ-
B19
+VIO
B20
AD(31)
B21
AD(29)
B22
GND
B23
AD(27)
B24
AD(25)
B25
+3.3V
B26
C/BE-(3)
B27
AD(23)
B28
GND
B29
AD(21)
B30
AD(19)
B31
+3.3V
B32
AD(17)
B33
C/BE-(2)
B34
GND
B35
IRDY-
B36
+3.3V
B37
DEVSEL-
B38
GND
B39
LOCK-
B40
PERR-
B41
+3.3V
B42
SERR-
B43
+3.3V
B44
C/BE-(1)
B45
AD(14)
B46
GND
B47
AD(12)
B48
AD(10)
B49
GND/M66EN
B50
GND
B51
GND
B52
AD(8)
B53
AD(7)
B54
+3.3V
B55
AD(5)
B56
AD(3)
B57
GND
B58
AD(1)
B59
+VIO
B60
ACK64-
B61
+5V
B62
+5V
B63
RSV
B64
GND
B65
C/BE-(6)
B66
C/BE-(4)
B67
GND
B68
AD(63)
B69
AD(61)
B70
+VIO
B71
AD(59)
B72
AD(57)
B73
GND
B74
AD(55)
B75
AD(53)
B76
GND
B77
AD(51)
B78
AD(49)
B79
+VIO
B80
AD(47)
B81
AD(45)
B82
GND
B83
AD(43)
B84
AD(41)
B85
GND
B86
AD(39)
B87
AD(37)
B88
+VIO
B89
AD(35)
B90
AD(33)
B91
GND
B92
RSV
B93
RSV
B94
GND
PCI64CON_3.3V
PCI64CON
KEY
TRST-
+12V
TMS
TDI
+5V P64IRQ0 P64IRQ2
+5V
RSV
+VIO
RSV
+3.3VAUX
RESET-
+VIO
GNT-
GND
PME#
AD(30)
+3.3V AD(28) AD(26)
GND
AD(24)
IDSEL
+3.3V AD(22) AD(20)
GND AD(18) AD(16)
+3.3V
FRAME-
GND
TRDY-
GND
STOP-
+3.3V
SDONE
SBO-
GND
PAR
AD(15)
+3.3V AD(13) AD(11)
GND
AD(09)
GND GND
C/BE-(0)
+3.3V AD(06) AD(04)
GND AD(02) AD(00)
+VIO
REQ64-
+5V +5V
GND
C/BE-(7) C/BE-(5)
+VIO
PAR64
AD(62)
GND AD(60) AD(58)
GND AD(56) AD(54)
+VIO AD(52) AD(50)
GND AD(48) AD(46)
GND AD(44) AD(42)
+VIO AD(40) AD(38)
GND AD(36) AD(34)
GND AD(32)
RSV
GND
RSV
A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11
A14 A15 A16 A17 A18 A19 A20 A21 A22 A23 A24 A25 A26 A27 A28 A29 A30 A31 A32 A33 A34 A35 A36 A37 A38 A39 A40 A41 A42 A43 A44 A45 A46 A47 A48 A49 A50 A51
A52 A53 A54 A55 A56 A57 A58 A59 A60 A61 A62
A63 A64 A65 A66 A67 A68 A69 A70 A71 A72 A73 A74 A75 A76 A77 A78 A79 A80 A81 A82 A83 A84 A85 A86 A87 A88 A89 A90 A91 A92 A93 A94
3
P1_PA_GNT3_N SLOT_1_TMS
EMRL_ENL P1_PA_IRQ0
SCSI_IRQA
P1_PA_IRQ4 P1_PA_GNT1_N
P1_PA_PCIRST_N P1_PA_GNT0_N
P1_PA_AD30 P1_PA_AD28
P1_PA_AD26 P1_PA_AD24
P1_PA_AD22 P1_PA_AD20
P1_PA_AD18 P1_PA_AD16
P1_PA_FRAME_N P1_PA_TRDY_N P1_PA_STOP_N
P1_PA_PAR P1_PA_AD15
P1_PA_AD13 P1_PA_AD11
P1_PA_AD9
P1_PA_CBE0_N P1_PA_AD6
P1_PA_AD4 P1_PA_AD2
P1_PA_AD0 P1_PA_REQ64_N
P1_PA_CBE7_N P1_PA_CBE5_N
P1_PA_PAR64 P1_PA_AD62
P1_PA_AD60 P1_PA_AD58
P1_PA_AD56 P1_PA_AD54
P1_PA_AD52 P1_PA_AD50
P1_PA_AD48 P1_PA_AD46
P1_PA_AD44 P1_PA_AD42
P1_PA_AD40 P1_PA_AD38
P1_PA_AD36 P1_PA_AD34
P1_PA_AD32
P1_PA_GNT3_N [22]
SLOT_1_TMS [55] EMRL_ENL [55]
P1_PA_IRQ0 [22,26] SCSI_IRQA [30,55]
P1_PA_IRQ4 [22,26]
P1_PA_GNT1_N [22]
P1_PA_PCIRST_N [22,30] P1_PA_GNT0_N [22]
R1447 100/6/X R1875 100/6
P1_PA_FRAME_N [22,30] P1_PA_TRDY_N [22,30] P1_PA_STOP_N [22,30] I2C_BUS2_CLK [28,35]
I2C_BUS2_DAT [28,35] P1_PA_PAR [22,30]
P1_PA_CBE0_N [22,30]
P1_PA_REQ64_N [22,30]
P1_PA_CBE7_N [22,30] P1_PA_CBE5_N [22,30]
P1_PA_PAR64 [22,30]
VCC3_DUAL
40MIL
ICH3_PME_N [28,31,35,36,51]
P1_PA_AD21 P1_PA_AD23
2
P1_PA_AD[0..63][22,30,55]
P1_PA_AD[0..63]
VCC3
SLOT_1_TMS
EMRL_ENL
R293 5.6K/6
R294 5.6K/6/X
C1283
C1284
0.1U/6
0.1U/6
C1348
4.7U/10V/8
Close to PCI1
Title
Size Document Number Rev
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
PCIX SLOT1
GA-8IPP533
27 58Tuesday, October 21, 2003
1
1.3
5
4
3
2
1
PCI-X SLOT 2 (P64H2 #1,PCI BUS B)
VCC3 +12VVCC-12V
PCI2
B1
-12V
D D
P1_PB_PCLK2[23]
C1659 10P/6/X
C C
P1_PB_PCIXCAP[23]
B B
A A
R917
0/6
P1_HB_M66ENB1[23]
5
P1_PB_IRQ9[23,26]
P1_PB_PCLK3[23]
VCC1_8
P1_PB_IRQ3 P1_PB_IRQ5
P1_PB_PCLK2
P1_PB_REQ2_N P1_PB_AD31
P1_PB_AD29 P1_PB_AD27
P1_PB_AD25 P1_PB_CBE3_N
P1_PB_AD23 P1_PB_AD21
P1_PB_AD19 P1_PB_AD17
P1_PB_CBE2_N P1_PB_IRDY_N P1_PB_DEVSEL_N
SLOT_1_PCIXCAP P1_PB_PLOCK_N P1_PB_PERR_N
P1_PB_SERR_N P1_PB_CBE1_N
P1_PB_AD14 P1_PB_AD12
P1_PB_AD10 P1_HB_M66ENB1
P1_PB_AD8 P1_PB_AD7
P1_PB_AD5 P1_PB_AD3
P1_PB_ACK64_N
RTCVDD
P1_PB_CBE6_N P1_PB_CBE4_N
P1_PB_AD63 P1_PB_AD61
P1_PB_AD59 P1_PB_AD57
P1_PB_AD55 P1_PB_AD53
P1_PB_AD51 P1_PB_AD49
P1_PB_AD45 P1_PB_AD43
P1_PB_AD41 P1_PB_AD39
P1_PB_AD37 P1_PB_AD35
P1_PB_AD33
P1_PB_IRQ3[23,26] P1_PB_IRQ5[23,26]
P1_PB_REQ3_N[23,26]
P1_PB_REQ2_N[23,26]
P1_PB_CBE3_N[23,31]
P1_PB_CBE2_N[23,31] P1_PB_IRDY_N[23,26,31]
P1_PB_DEVSEL_N[23,26,31]
P1_PB_PLOCK_N[23,26,31] P1_PB_PERR_N[23,26,31]
P1_PB_SERR_N[23,26,31] P1_PB_CBE1_N[23,31]
C421
0.01U/6
P1_PB_ACK64_N[23,26,31]
P1_PB_CBE6_N[23,26,31] P1_PB_CBE4_N[23,26,31]
B2
TCK
B3
GND
B4
TDO
B5
+5V
B6
+5V
B7
P64IRQ1
B8
P64IRQ3
B9
PRSNT1-
B10
RSV
B11
PRSNT2-
B14
RSV
B15
GND
B16
CLK
B17
GND
B18 B19 B20 B21 B22 B23 B24 B25 B26 B27 B28 B29 B30 B31 B32 B33 B34 B35 B36 B37 B38 B39 B40 B41 B42 B43 B44 B45 B46 B47 B48 B49 B50 B51
B52 B53 B54 B55 B56 B57 B58 B59 B60 B61 B62
B63 B64 B65 B66 B67 B68 B69 B70 B71 B72 B73 B74 B75 B76 B77 B78 B79 B80 B81 B82 B83 B84 B85 B86 B87 B88 B89 B90 B91 B92 B93 B94
4
PCI64CON
REQ­+VIO AD(31) AD(29) GND AD(27) AD(25) +3.3V C/BE-(3) AD(23) GND AD(21) AD(19) +3.3V AD(17) C/BE-(2) GND IRDY­+3.3V DEVSEL­GND LOCK­PERR­+3.3V SERR­+3.3V C/BE-(1) AD(14) GND AD(12) AD(10) GND/M66EN GND GND
AD(8) AD(7) +3.3V AD(5) AD(3) GND AD(1) +VIO ACK64­+5V +5V
KEY
RSV GND C/BE-(6) C/BE-(4) GND AD(63) AD(61) +VIO AD(59) AD(57) GND AD(55) AD(53) GND AD(51) AD(49) +VIO AD(47) AD(45) GND AD(43) AD(41) GND AD(39) AD(37) +VIO AD(35) AD(33) GND RSV RSV GND
PCI64CON_3.3V
TRST-
+12V
TMS
TDI
+5V P64IRQ0 P64IRQ2
+5V
RSV
+VIO
RSV
+3.3VAUX
RESET-
+VIO
GNT-
GND
PME#
AD(30)
+3.3V AD(28) AD(26)
GND
AD(24)
IDSEL
+3.3V AD(22) AD(20)
GND AD(18) AD(16)
+3.3V
FRAME-
GND
TRDY-
GND
STOP-
+3.3V
SDONE
SBO-
GND
PAR
AD(15)
+3.3V AD(13) AD(11)
GND
AD(09)
GND GND
C/BE-(0)
+3.3V AD(06) AD(04)
GND AD(02) AD(00)
+VIO
REQ64-
+5V +5V
GND
C/BE-(7) C/BE-(5)
+VIO
PAR64
AD(62)
GND AD(60) AD(58)
GND AD(56) AD(54)
+VIO AD(52) AD(50)
GND AD(48) AD(46)
GND AD(44) AD(42)
+VIO AD(40) AD(38)
GND AD(36) AD(34)
GND AD(32)
RSV
GND
RSV
A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11
A14 A15 A16 A17 A18 A19 A20 A21 A22 A23 A24 A25 A26 A27 A28 A29 A30 A31 A32 A33 A34 A35 A36 A37 A38 A39 A40 A41 A42 A43 A44 A45 A46 A47 A48 A49 A50 A51
A52 A53 A54 A55 A56 A57 A58 A59 A60 A61 A62
A63 A64 A65 A66 A67 A68 A69 A70 A71 A72 A73 A74 A75 A76 A77 A78 A79 A80 A81 A82 A83 A84 A85 A86 A87 A88 A89 A90 A91 A92 A93 A94
P1_PB_IRQ2 P1_PB_IRQ4
P1_PB_PCIRST_N P1_PB_GNT2_N
P1_PB_AD30 P1_PB_AD28
P1_PB_AD26 P1_PB_AD24
SLOT_1_IDSEL P1_PB_AD22
P1_PB_AD20 P1_PB_AD18
P1_PB_AD16 P1_PB_FRAME_N P1_PB_TRDY_N P1_PB_STOP_N
P1_PB_PAR P1_PB_AD15
P1_PB_AD13 P1_PB_AD11
P1_PB_AD9
P1_PB_CBE0_N P1_PB_AD6
P1_PB_AD4 P1_PB_AD2
P1_PB_AD0P1_PB_AD1 P1_PB_REQ64_N
P1_PB_CBE7_N P1_PB_CBE5_N
P1_PB_PAR64 P1_PB_AD62
P1_PB_AD60 P1_PB_AD58
P1_PB_AD56 P1_PB_AD54
P1_PB_AD52 P1_PB_AD50
P1_PB_AD48 P1_PB_AD46P1_PB_AD47
P1_PB_AD44 P1_PB_AD42
P1_PB_AD40 P1_PB_AD38
P1_PB_AD36 P1_PB_AD34
P1_PB_AD32
3
P1_PB_IRQ7 [23,26] P1_PB_IRQ6 [23,26]
P1_PB_IRQ8 [23,26]
P1_PB_IRQ2 [23,26] P1_PB_IRQ4 [23,26]
P1_PB_GNT3_N [23] CASE_OPEN1 [39,40,49]
40MIL
P1_PB_PCIRST_N [23,31] P1_PB_GNT2_N [23]
R292 100/6
P1_PB_FRAME_N [23,26,31] P1_PB_TRDY_N [23,26,31] P1_PB_STOP_N [23,26,31] I2C_BUS2_CLK [27,35]
I2C_BUS2_DAT [27,35] P1_PB_PAR [23,26,31]
P1_PB_CBE0_N [23,31]
P1_PB_REQ64_N [23,26,31]
P1_PB_CBE7_N [23,26,31] P1_PB_CBE5_N [23,26,31]
P1_PB_PAR64 [23,26,31]
VCC1_8
VCC3_DUAL
P1_PB_AD20
ICH3_PME_N [27,31,35,36,51]
2
P1_PB_AD[0..63][23,26,31]
Title
Size Document Number Rev
Date: Sheet of
P1_PB_AD[0..63]
VCC3
C413
C414
0.1U/6
22U/12
VCC
C1276
C1277
0.1U/6
22U/12
GIGA-BYTE TECHNOLOGY CO., LTD.
PCIX SLOT2
GA-8IPP533
28 58Tuesday, October 21, 2003
1
1.3
5
147
U24C
ICH3_PCIRST_N[35,36,37,39,43,48,51]
D D
C C
INDEX_N TRK0_N WP_N RDATA_N
B B
246
RP5 8P4R-150
135
VCC
LAN2_COMB_ACT_N
SPEEDC1
A A
SPEEDC2 LAN1_COMB_ACT_N
ACTC1
R1008 330/6
ACTC2
R1010 330/6
DSKCHG_N
8
R1506 150/6
7
SBC91
0.1U/6
5
R1002 330/6/X
9 8
74LVC125
PCISLOT4_CLK33
C1345
10P/6
VCC3
RN207
7
8
5
6
3
4
1
2
8P4R-330/X
LAN1_COMB_ACT_N [31] LAN2_COMB_ACT_N [31]
10
VCC
Q199 2N7002
+12V
2
5VSB
CPU0_LED[39] CPU1_LED[39] SYS_LED[39] SYSEVENT_N[41]
PWB+[39,42] PWB-[42]
LAN1_LINK_UP_N[31]
LAN1_COMB_SPD_N[31]
LAN2_LINK_UP_N[31] LAN2_COMB_SPD_N[31] GN+[36,42]
4
R1915 4.7K/6
3
R503 33/6
1
HDD_FAIL
R1794
ICH3_PDD[0..15][37]
CPU0_LED
CPU1_LED
SYS_LED SYSEVENT_N
ACTC1 SPEEDC1 ACTC2 SPEEDC2 PWR_LED PWB+ PWB-
ICH3_PCIRST_N[35,36,37,39,43,48,51]
ICH3_CBE3_N[35,36,43]
ICH3_DEVSEL_N[35,36,43] ICH3_PLOCK_N[35,36] ICH3_PERR_N[35,36]
ICH3_SERR_N[35,36]
HDD_FAIL[40]
2N7002
R1906 10K/6 R1905
HDD_FAIL
BMC_PWR_LED_N[51]
REV:0.5 ADD Q196,R1905,R1906
1K/6
3
Q187
2
R1864 330/6
1
4
VCC
R1012 330/6 R1013 330/6 R1014 330/6
LAN1_LINK_UP_N LAN1_COMB_SPD_N
LAN2_LINK_UP_N LAN2_COMB_SPD_N GN+
PCISLOT4_CLK33[46]
ICH3_PIRQE_N[36] ICH3_PIRQF_N[36]
ICH3_REQ1_N[36] ICH3_REQ2_N[36]
ID_SW[41,51]
ICH3_CBE2_N[35,36,43] ICH3_IRDY_N[35,36,43]
ICH3_CBE1_N[35,36,43]
Q195
2N7002
2
2
Q196 2N3906
IDE_PRST#
R498
4.7K/6
R16660/6
R16670/6/X
VCCVCC3
ICH3_PDD7 ICH3_PDD6 ICH3_PDD5 ICH3_PDD4
ICH3_PDD3 ICH3_PDD2 ICH3_PDD1 ICH3_PDD0
DDREQA
-DIOWA
-DIORA HDRDYA
-DDACKA PIDEINT
PDA1 PDA0
-PDCS1
-DASP0
PCISLOT4_CLK33
ID_SW
ICH3_AD31 ICH3_AD29 ICH3_AD27 ICH3_AD25
ICH3_CBE3_N ICH3_AD23 ICH3_AD21 ICH3_AD19 ICH3_AD17
ICH3_CBE2_N ICH3_IRDY_N
ICH3_DEVSEL_N
ICH3_PLOCK_N ICH3_PERR_N
ICH3_SERR_N ICH3_CBE1_N
ICH3_AD14 ICH3_AD12 ICH3_AD10
ICH3_AD8 ICH3_AD7 ICH3_AD5 ICH3_AD3 ICH3_AD2 ICH3_AD1
R1796 1K/6
3
BMCPWRLED
1 1
3
33/6
5VSB
R1861 0/6
A10 B10 A11 B11 A12 B12 A13 B13 A14 B14 A15 B15 A16 B16 A17 B17 A18 B18 A19 B19 A20 B20 A21 A22 A23 A24 B24 A25 B25 A26 B26 A27 B27 A28 B28 A29 B29 A30 B30 A31 B31 A32 B32 A33 B33 A34 B34 A35 B35 A36 B36 A37 B37 A38 B38 A39 B39 A40 B40 A41 B41 A42 B42 A43 B43 A44 A45 A46 A47 B47 A48 B48 A49 B49 A50 B50 A51 B51 A52 B52 A53 B53 A54 B54 A55 B55 A56 B56 A57 B57 A58 B58 A59 B59 A60 B60 A61 B61 A62 B62 A63 B63 A64 A65 A66 A67 A68 A69 A70 A71 A72 A73 A74 A75 A76 A77 A78 A79 A80
2
3
J11
A1 B1
1 81
A2 B2
2 82
A3 B3
3 83
A4 B4
4 84
A5 B5
5 85
A6 B6
6 86
A7 B7
7 87
A8 B8
8 88
A9 B9
9 89 10 90 11 91 12 92 13 93 14 94 15 95 16 96 17 97 18 98 19 99 20 100 21
101
22
102
23
103 24 104 25 105 26 106 27 107 28 108 29 109 30 110 31 111 32 112 33 113 34 114 35 115 36 116 37 117 38 118 39 119 40 120 41 121 42 122 43 123 44
124 45
125 46
126 47 127 48 128 49 129 50 130 51 131 52 132 53 133 54 134 55 135 56 136 57 137 58 138 59 139 60 140 61 141 62 142 63 143 64
144 65
145 66
146 67
147 68
148 69
149 70
150 71
151 72
152 73
153 74
154 75
155 76
156 77
157 78
158 79
159 80
160
IDE&FDD Connector
5VSB
PWR_LED IS HIGH,THEN POWER LED IS ORANGE
R1795 100/6/X
PWR_LED
3
Q188 2N7002/X
1
3
B21 B22 B23
B44 B45 B46
B64 B65 B66 B67 B68 B69 B70 B71 B72 B73 B74 B75 B76 B77 B78 B79 B80
FOR 8IPP533-FSC ADD R1861
ICH3_PDD8 ICH3_PDD9 ICH3_PDD10 ICH3_PDD11 ICH3_PDD12
ICH3_PDD13 ICH3_PDD14 ICH3_PDD15 PD_80P PDA2
-PDCS3 DENSEL DRATE0 INDEX_N
MTR0_N DR1_N DR0_N MTR1_N DIR_N STEP_N WDATA_N WGATE_N TRK0_N
WP_N RDATA_N HDSEL_N DSKCHG_N
I2C_BUS3_DAT I2C_BUS3_CLK
R1421 0/6
DCD2_B
RXD2_B TXD2_B DTR2_B COM2-5 DSR2_B RTS2_B CTS2_B RI2_B
RST_SW ID_LED NMI_SW
ICH3_AD30
ICH3_AD28 ICH3_AD26
I2C_BUS1_DAT I2C_BUS1_CLK
ICH3_AD24 ICH3_AD22 ICH3_AD20 ICH3_AD18 ICH3_AD16
ICH3_FRAME_N
ICH3_TRDY_N ICH3_STOP_N ICH3_PAR
ICH3_AD15
ICH3_AD13 ICH3_AD11 ICH3_AD9
ICH3_CBE0_N ICH3_AD6 ICH3_AD4
ICH3_AD0
C795 47000P/6/X
DENSEL [39] DRATE0 [39] INDEX_N [39]
MTR0_N [39] DR1_N [39] DR0_N [39] MTR1_N [39] DIR_N [39] STEP_N [39] WDATA_N [39] WGATE_N [39] TRK0_N [39]
WP_N [39] RDATA_N [39] HDSEL_N [39] DSKCHG_N [39]
I2C_BUS3_DAT [35]
I2C_BUS3_CLK [35] DCD2_B [41] RXD2_B [41]
TXD2_B [41] DTR2_B [41]
DSR2_B [41] RTS2_B [41] CTS2_B [41] RI2_B [41,42]
RST_SW [42,48] ID_LED [41] NMI_SW [36]
ICH3_GNT1_N [36] ICH3_GNT2_N [36]
I2C_BUS1_DAT [35,49]
I2C_BUS1_CLK [35,49]
ICH3_FRAME_N [35,36,43]
ICH3_TRDY_N [35,36,43] ICH3_STOP_N [35,36,43] ICH3_PAR [35,36,43]
ICH3_CBE0_N [35,36,43]
2
ICH3_PDD[0..15] [37]
PD_80P [37]
R495 10K/6
EXTSMI3_N [37]
DISABLE SCSI TERMINATION
CLOSE_SCSI_TERM [39]
2
1
ICH3_AD[0..31][35,36,43]
ICH3_PDIOW_N[37] ICH3_PDIOR_N[37] ICH3_PDDACK_N[37]
ICH3_PDIRDY_N[37] ICH3_PDDREQ[37]
ICH3_PDCS1_N[37] ICH3_PDCS3_N[37]
ICH3_PDA2[37] ICH3_PDA1[37] ICH3_PDA0[37]
ICH3_PDIOR_N -DIORA ICH3_PDDACK_N -DDACKA
ICH3_PDCS1_N -PDCS1 ICH3_PDCS3_N -PDCS3
ICH3_PDA2 ICH3_PDA1 ICH3_PDA0
HDRDYA
R491 4.7K/6
DDREQA
R493 5.6K/6/X
R496 10K/6
PIDEINT
R497 0/6
-DIOWAICH3_PDIOW_N
HDRDYAICH3_PDIRDY_N DDREQAICH3_PDDREQ
PDA2 PDA1 PDA0
VCC3
VCC3
IRQ14 [36]
Near Connector
5VSB
REV:0.5 ADD U171,R1904
U171 NC7S86/SOT23-5/X
R1904 10K/6/X
VCC
BMC_PWR_LED_N
Title
Size Document Number Rev
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
BRIDGE BOARD CONN (IDE FDD)
53
1
EX-OR
2
GA-8IPP533
4
1
BMCPWRLED
29 58Tuesday, October 21, 2003
1.3
5
D D
C C
FAN_SENSE2[40]
B B
FAN_SENSE2
R1847 0/6
R1848 0/6/X
FAN_SENSE2_A FAN_SENSE2_B
VCC
VCC3
FAN_SENSE5[40]
A A
FAN_SENSE5
R1849 0/6
R1850 0/6/X
FAN_SENSE5_A FAN_SENSE5_B
4
P1_PA_CBE0_N[22,27]
P1_PA_AD1[22,27] P1_PA_AD3[22,27] P1_PA_AD4 [22,27] P1_PA_AD5[22,27] P1_PA_AD6 [22,27] P1_PA_AD7[22,27]
P1_PA_CBE1_N[22,27]
P1_PA_AD9[22,27] P1_PA_AD11[22,27] P1_PA_AD13[22,27] P1_PA_AD15[22,27] P1_PA_CBE2_N [22,27]
P1_PA_AD17[22,27] P1_PA_AD18 [22,27] P1_PA_AD19[22,27] P1_PA_AD20 [22,27] P1_PA_AD21[22,27] P1_PA_AD22 [22,27,55]
P1_PA_AD23[22,27]
P1_PA_CBE3_N[22,27]
P1_PA_AD25[22,27] P1_PA_AD27[22,27] P1_PA_AD29[22,27] P1_PA_AD31[22,27] P1_PA_AD33[22,27] P1_PA_AD35[22,27] P1_PA_AD37[22,27]
P1_PA_AD39[22,27]
P1_PA_CBE5_N[22,27]
P1_PA_AD41[22,27] P1_PA_AD43[22,27] P1_PA_AD45[22,27] P1_PA_AD47[22,27] P1_PA_AD49[22,27] P1_PA_AD51[22,27] P1_PA_AD53[22,27]
P1_PA_AD55[22,27]
P1_PA_CBE7_N[22,27]
P1_PA_AD57[22,27] P1_PA_AD59[22,27] P1_PA_AD61[22,27] P1_PA_AD63[22,27]
P1_PA_PCIRST_N[22,27]
P1_PA_PCLK2[22]
SCSI_IRQB[27,55]
P1_PA_ACK64_N[22,27] P1_PA_PAR64[22,27]
P1_PA_IRDY_N[22,27]
P1_PA_DEVSEL_N[22,27]
P1_PA_STOP_N[22,27]
P1_PA_SERR_N[22,27]
FAN_SENSE3[40]
FAN_SENSE4[40]
P1_PA_CBE0_N P1_PA_AD1 P1_PA_AD3 P1_PA_AD4 P1_PA_AD5 P1_PA_AD6 P1_PA_AD7
P1_PA_CBE1_N P1_PA_AD9 P1_PA_AD11 P1_PA_AD13 P1_PA_AD15 P1_PA_CBE2_N
P1_PA_AD17 P1_PA_AD18 P1_PA_AD19 P1_PA_AD20 P1_PA_AD21
P1_PA_AD23 P1_PA_CBE3_N P1_PA_AD25 P1_PA_AD27 P1_PA_AD29 P1_PA_AD31 P1_PA_AD33 P1_PA_AD35 P1_PA_AD37
P1_PA_AD39 P1_PA_CBE5_N P1_PA_AD41 P1_PA_AD43 P1_PA_AD45 P1_PA_AD47 P1_PA_AD49 P1_PA_AD51 P1_PA_AD53
P1_PA_AD55 P1_PA_CBE7_N P1_PA_AD57 P1_PA_AD59 P1_PA_AD61 P1_PA_AD63
P1_PA_PCIRST_N P1_PA_PCLK2 SCSI_IRQB P1_PA_ACK64_N
P1_PA_PAR64 P1_PA_IRDY_N
P1_PA_DEVSEL_N P1_PA_STOP_N
P1_PA_SERR_N
FAN_SENSE2_A
FAN_SENSE1
FAN_SENSE2_B
FAN_SENSE3
FAN_SENSE4 FAN_SENSE5_B FAN_SENSE5_A
USBDT2-[47] USBDT2+[47] USBDT2[47]
USBDT2­USBDT2+ USBDT2 USBDT3
A10 A11 A12 A13 A14 A15 A16 A17 A18 A19 A20 A21 A22 A23 A24 A25 A26 A27 A28 A29 A30 A31 A32 A33 A34 A35 A36 A37 A38 A39 A40 A41 A42 A43 A44 A45 A46 A47 A48 A49 A50 A51 A52 A53 A54 A55 A56 A57 A58 A59 A60 A61 A62 A63 A64 A65 A66 A67 A68 A69 A70 A71 A72 A73 A74 A75 A76 A77 A78 A79 A80
3
J13
A1
1
A2
2
A3
3
A4
4
A5
5
A6
6
A7
7
A8
8
A9
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80
100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160
B1
81
B2
82
B3
83
B4
84
B5
85
B6
86
B7
87
B8
88
B9
89
B10
90
B11
91
B12
92
B13
93
B14
94
B15
95
B16
96
B17
97
B18
98
B19
99
B20 B21 B22 B23 B24 B25 B26 B27 B28 B29 B30 B31 B32 B33 B34 B35 B36 B37 B38 B39 B40 B41 B42 B43 B44 B45 B46 B47 B48 B49 B50 B51 B52 B53 B54 B55 B56 B57 B58 B59 B60 B61 B62 B63 B64 B65 B66 B67 B68 B69 B70 B71 B72 B73 B74 B75 B76 B77 B78 B79 B80
P1_PA_AD0 P1_PA_AD2
P1_PA_AD8 P1_PA_AD10
P1_PA_AD12 P1_PA_AD14
P1_PA_AD16
P1_PA_AD22 P1_PA_AD24
P1_PA_AD26 P1_PA_AD28 P1_PA_AD30
P1_PA_CBE4_N P1_PA_AD32 P1_PA_AD34 P1_PA_AD36
P1_PA_AD38 P1_PA_AD40 P1_PA_AD42 P1_PA_AD44 P1_PA_AD46
P1_PA_CBE6_N P1_PA_AD48 P1_PA_AD50
P1_PA_AD52 P1_PA_AD54 P1_PA_AD56 P1_PA_AD58 P1_PA_AD60 P1_PA_AD62
SCSI_IRQA P1_PA_REQ2_N
P1_PA_GNT2_N SCSI_IDSEL_L
P1_PA_REQ64_N P1_PA_FRAME_N P1_PA_PAR P1_PA_TRDY_N P1_PA_PERR_N
ADM_PWM1
ADM_DAC BMC_PWM1
BMC_PWM2
P1_PA_PCIXCAP USBDT3+
USBDT3-
P1_PA_AD0 [22,27] P1_PA_AD2 [22,27]
P1_PA_AD8 [22,27] P1_PA_AD10 [22,27]
P1_PA_AD12 [22,27] P1_PA_AD14 [22,27]
P1_PA_AD16 [22,27]
P1_PA_AD24 [22,27] P1_PA_AD26 [22,27] P1_PA_AD28 [22,27] P1_PA_AD30 [22,27]
P1_PA_CBE4_N [22,27] P1_PA_AD32 [22,27] P1_PA_AD34 [22,27] P1_PA_AD36 [22,27]
P1_PA_AD38 [22,27] P1_PA_AD40 [22,27] P1_PA_AD42 [22,27] P1_PA_AD44 [22,27] P1_PA_AD46 [22,27]
P1_PA_CBE6_N [22,27] P1_PA_AD48 [22,27] P1_PA_AD50 [22,27]
P1_PA_AD52 [22,27] P1_PA_AD54 [22,27] P1_PA_AD56 [22,27] P1_PA_AD58 [22,27] P1_PA_AD60 [22,27]
P1_PA_AD62 [22,27] SCSI_IRQA [27,55] P1_PA_REQ2_N [22,26]
P1_PA_GNT2_N [22]
P1_PA_REQ64_N [22,27]
P1_PA_FRAME_N [22,27]
P1_PA_PAR [22,27]
P1_PA_TRDY_N [22,27]
P1_PA_PERR_N [22,27] ADM_PWM1 [40]
ADM_DAC [40] BMC_PWM1 [51]FAN_SENSE1[40]
BMC_PWM2 [51]
P1_PA_PCIXCAP [22,27]P1_HA_M66ENA2[22,27]
USBDT3+ [47]
USBDT3- [47]
USBDT3 [47]
SCSI Connector
2
R55 100/6
SCSI_IDSELSCSI_IDSEL_L
SCSI_IDSEL [55]
1
VCC
VCC3
5VSB
Title
Size Document Number Rev
5
4
3
2
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
BRIDGE BOARD CONN (SCSI)
GA-8IPP533
30 58Tuesday, October 21, 2003
1
1.3
5
5
P1_PB_AD[0..63]
VCC3_DUAL
R304 10K/6
LAN1_PME_N
P1_HB_M66ENA
C430
0.01U/6
P1_PB_CBE0_N[23,28] P1_PB_CBE1_N[23,28] P1_PB_CBE2_N[23,28] P1_PB_CBE3_N[23,28] P1_PB_CBE4_N[23,26,28] P1_PB_CBE5_N[23,26,28] P1_PB_CBE6_N[23,26,28] P1_PB_CBE7_N[23,26,28]
P1_PB_PAR[23,26,28] P1_PB_PAR64[23,26,28] P1_PB_FRAME_N[23,26,28] P1_PB_IRDY_N[23,26,28] P1_PB_TRDY_N[23,26,28] P1_PB_STOP_N[23,26,28]
P1_PB_DEVSEL_N[23,26,28] P1_PB_REQ64_N[23,26,28] P1_PB_ACK64_N[23,26,28] P1_PB_REQ0_N[23,26]
P1_PB_GNT0_N[23] P1_PB_PLOCK_N[23,26,28] P1_HB_M66ENA[23]
P1_PB_IRQ0[23,26] P1_PB_IRQ1[23,26]
P1_PB_PCLK0[23]
P1_PB_PCIRST_N ICH3_PME_N
P1_PB_AD18
R1576 0/6/X
R1512
P1_PB_AD0 P1_PB_AD1 P1_PB_AD2 P1_PB_AD3 P1_PB_AD4 P1_PB_AD5 P1_PB_AD6 P1_PB_AD7 P1_PB_AD8 P1_PB_AD9 P1_PB_AD10 P1_PB_AD11 P1_PB_AD12 P1_PB_AD13 P1_PB_AD14 P1_PB_AD15 P1_PB_AD16 P1_PB_AD17 P1_PB_AD18 P1_PB_AD19 P1_PB_AD20 P1_PB_AD21 P1_PB_AD22 P1_PB_AD23 P1_PB_AD24 P1_PB_AD25 P1_PB_AD26 P1_PB_AD27 P1_PB_AD28 P1_PB_AD29 P1_PB_AD30 P1_PB_AD31 P1_PB_AD32 P1_PB_AD33 P1_PB_AD34 P1_PB_AD35 P1_PB_AD36 P1_PB_AD37 P1_PB_AD38 P1_PB_AD39 P1_PB_AD40 P1_PB_AD41 P1_PB_AD42 P1_PB_AD43 P1_PB_AD44 P1_PB_AD45 P1_PB_AD46 P1_PB_AD47 P1_PB_AD48 P1_PB_AD49 P1_PB_AD50 P1_PB_AD51 P1_PB_AD52 P1_PB_AD53 P1_PB_AD54 P1_PB_AD55 P1_PB_AD56 P1_PB_AD57 P1_PB_AD58 P1_PB_AD59 P1_PB_AD60 P1_PB_AD61 P1_PB_AD62 P1_PB_AD63
P1_PB_CBE0_N P1_PB_CBE1_N P1_PB_CBE2_N P1_PB_CBE3_N P1_PB_CBE4_N P1_PB_CBE5_N P1_PB_CBE6_N P1_PB_CBE7_N
P1_PB_PAR P1_PB_PAR64 P1_PB_FRAME_N P1_PB_IRDY_N P1_PB_TRDY_N P1_PB_STOP_N LAN1_IDSEL P1_PB_DEVSEL_N P1_PB_REQ64_N P1_PB_ACK64_N P1_PB_REQ0_N P1_PB_GNT0_N P1_PB_PLOCK_N P1_HB_M66ENA
P1_PB_IRQ0 P1_PB_IRQ1
P1_PB_PCLK0 LAN_PWROK
LAN1_PME_N
0/6
GIGA1_VIVO1_2
R1542 1K/6/X
P1_PB_AD[0..63][23,26,28]
D D
LAN1_IDSEL
R301 100/6
IDSEL:P1_PB_AD18
C C
VCC3_DUALVCC3
R302
R1907
100K/6
100K/6/X
GIGA1_VIVO1_2
C428
0.01U/6
B B
REV:0.5 ADD R1907
A A
LAN_PWROK[33] ICH3_PWROK[11,38,48]
P1_PB_PCIRST_N[23,28]
ICH3_PME_N[27,28,35,36,51]
T14 V14 Y15
W14
T13 V13 Y14 U12 V12 T12
W12
Y12 V11 T11 Y11
W10
L16 M20 M19 M16 M18 M17
N20
N16
P20
N18
P19
P16
R20
P18
P17
T20
R16
U20
R18
T19
V20
T18 W20
V19
T17
U18
V18
U16
V17 W18
Y19
T16
Y13
V10
V16
Y18
Y17
T15
U10
V15
U14 W16
Y16
A17
Y20
U8 Y7 Y6 V7 T7
W6
Y5 V6 U6 V5
W4
V4 Y3 U4 V3 V1
T8 Y4
V8
W8
Y8 V9 T6 T9
W2
T3 Y9
Y2 T1
U2
T5 T4
Y1
A8
4
U6A
AD0 AD1 AD2 AD3 AD4 AD5 AD6 AD7 AD8 AD9 AD10 AD11 AD12 AD13 AD14 AD15 AD16 AD17 AD18 AD19 AD20 AD21 AD22 AD23 AD24 AD25 AD26 AD27 AD28 AD29 AD30 AD31 AD32 AD33 AD34 AD35 AD36 AD37 AD38 AD39 AD40 AD41 AD42 AD43 AD44 AD45 AD46 AD47 AD48 AD49 AD50 AD51 AD52 AD53 AD54 AD55 AD56 AD57 AD58 AD59 AD60 AD61 AD62 AD63
CBE#0 CBE#1 CBE#2 CBE#3 CBE#4 CBE#5 CBE#6 CBE#7
PAR PAR64 FRAME# IRDY# TRDY# STOP# IDSEL DEVSEL# REQ64# ACK64# REQ# GNT# LOCK# M66EN
INTA# INTB#
CLK LAN_PWRGD
RST# PME#
VIO VIO
TEST
82546EB
4
Gigabit
ETHERN ET
82546EB
(Anvik )
SERR# PERR#
ZN_COMP ZP_COMP
RSVD RSVD RSVD RSVD RSVD RSVD RSVD RSVD RSVD RSVD RSVD RSVD RSVD RSVD RSVD RSVD RSVD RSVD RSVD RSVD RSVD RSVD RSVD RSVD RSVD RSVD RSVD RSVD RSVD
EE_CS EE_SK
EE_DI
EE_DO
FL_ADDR0 FL_ADDR1 FL_ADDR2 FL_ADDR3 FL_ADDR4 FL_ADDR5 FL_ADDR6 FL_ADDR7 FL_ADDR8
FL_ADDR9 FL_ADDR10 FL_ADDR11 FL_ADDR12 FL_ADDR13 FL_ADDR14 FL_ADDR15 FL_ADDR16 FL_ADDR17 FL_ADDR18
FL_CS# FL_OE# FL_WE#
FL_DATA0 FL_DATA1 FL_DATA2 FL_DATA3 FL_DATA4 FL_DATA5 FL_DATA6 FL_DATA7
LINKA#
ACTA#
LINK100#
LINK1000#
MDIA0+
MDIA0-
MDIA1+
MDIA1-
MDIA2+
MDIA2-
MDIA3+
MDIA3-
REFA
LINKB#
ACTB#
LINKB100#
LINKB1000#
MDIB0+
MDIB0-
MDIB1+
MDIB1-
MDIB2+
MDIB2-
MDIB3+
MDIB3-
REFB
3
P1_PB_SERR_N
T10
P1_PB_PERR_N
Y10
LAN1_ZN_COMP
T2
LAN1_ZP_COMP
R5 D4
D5 C4 E4 C5 E5 B5 E6 D7 C7 C6
R1649 1K/6/X
E10
R1816 1K/6/X
B7 A7 C8 E8 E9 D9 C9 B9 D10 A9
R1813 1K/6/X
C11
R1812 1K/6/X
B10 A20 B18 M5 E7
R1814 1K/6/X
A6
R1815 1K/6/X
LAN1_EE_CS
C20
LAN1_EE_SK
D20
LAN1_EE_DI
C19
LAN1_EE_DO
B20 F16
E18 E16 E15 E14 E13 D15
LAN1_DISABLE
B16 F17 F18
LAN2_DISABLE
G17 G16 B15 D19 D18 C15 D16 C18
REV:0.5 CHANGE VCC3 TO VCC3_DUAL
D17 H20
K18 C17
H16 G18 J16 H18 J17 J18 K17 K16
LAN1_LINK_UP_N
M1
LAN1_COMB_ACT_N
N1
LAN1-LINK100_N
N4
LAN1_COMB_SPD_N
N3
LAN1_MDI0
B2
LAN1_MDI0_N
B1
LAN1_MDI1
C2
LAN1_MDI1_N
C1
LAN1_MDI2
D2
LAN1_MDI2_N
D1
LAN1_MDI3
E2
LAN1_MDI3_N
E1
GIGA1_REF
E3
LAN2_LINK_UP_N
A13
LAN2_COMB_ACT_N
B13
LAN2-LINK100_N
C14
LAN2_COMB_SPD_N
C13
LAN2_MDI0
K3
LAN2_MDI0_N
L3
LAN2_MDI1
K1
LAN2_MDI1_N
L1
LAN2_MDI2
J1
LAN2_MDI2_N
J2
LAN2_MDI3
J3
LAN2_MDI3_N
H3 L4
R318 2.49K/6/1
3
P1_PB_SERR_N [23,26,28] P1_PB_PERR_N [23,26,28]
R295 33.2/6/1 R296 53.6/6/1
1 8 2 3 6 4 5
R298 1K/6/X
R1920 0/6/X
R1921 0/6/X
VCC3_DUAL
R1646
R1276
4.7K/6
4.7K/6
R303 2.49K/6/1
VCC3_DUAL
1 2 3 4 5 6 7 8
RN2428P4R-1K/X
1 2 3 4 5 6 7 8
RN2438P4R-1K/X
RN244
1 2 3 4 5 6 7 8
8P4R-0/X
U7
CS VCC SK DI ORG DO GND
93C66/3V
R1275
R1277
4.7K/6
4.7K/6
VCC3_DUAL
7
NC
VCC3_DUAL
R1652
4.7K/6/X
DISABLE_LAN- [33,37,39]
REV:0.5 CHANGE VCC3 TO VCC3_DUAL
R1272
R1274
4.7K/6
R1273
4.7K/6
4.7K/6
C1173 1000P/6
C1174 1000P/6
C1175 10U/12
R1648
4.7K/6
2
LAN2_MDI0 LAN2_MDI1
LAN2_MDI1_N
C426
0.01U/6
LAN1_MDI0_N LAN1_MDI1 LAN1_MDI1_N
LAN1_LINK_UP_N [29] LAN1_COMB_ACT_N [29]
LAN1_COMB_SPD_N [29]
LAN2_LINK_UP_N [29] LAN2_COMB_ACT_N [29]
LAN2_COMB_SPD_N [29]
C1168 10U/12
C1171 4.7U/12
C1172 4.7U/12
2
1
LAN2_MDI2 LAN2_MDI2_NLAN2_MDI0_N LAN2_MDI3
R1166
49.9/6/1
VCC2_5DUAL
LAN2_MDI3_N
R1167
49.9/6/1
R1168
49.9/6/1
C1154
0.01U/6
LANLED_PWR
R1163
49.9/6/1
R1164
49.9/6/1
C1152
0.01U/6
R1165
49.9/6/1
C1153
0.01U/6
LINK 10/100,LED IS GREEN,LINK1000,LED IS ORANGE
FB59 FB30/8
2 1
R1174
49.9/6/1
2 1
C1254
0.1U/6
C1256
0.1U/6
J36
1
TRD0+
2 3 4 5 15 6 7 8 9
10
1 2 3 4 5 15 6 7 8 9
10
G+ TRD0­TRD1+ TRD1­COM SH COM TRD2+ TRD2­TRD3+
Y+/ G-
TRD3-
Y-/ G+
RJ45-DUALLED
LAN2_COMB_SPD_N
LAN1_MDI2 LAN1_MDI2_NLAN1_MDI0 LAN1_MDI3 LAN1_MDI3_N
R1175
49.9/6/1
FB60 FB30/8
J35
TRD0+
G+ TRD0­TRD1+ TRD1­COM SH COM TRD2+ TRD2­TRD3+
Y+/ G-
TRD3-
Y-/ G+
RJ45-DUALLED
LAN1_COMB_SPD_N
G-
SH
G-
SH
GA-8IPP533
1
13 14
16
11 12
R1817 330/6
0.01U/6
VCC3_DUAL
13 14
16
11 12
R1818 330/6
R1176
49.9/6/1
C1166
2 1
LAN2_MDI0 LAN2_MDI0_N LAN2_MDI1 LAN2_MDI1_N
LAN2_MDI2 LAN2_MDI2_N LAN2_MDI3 LAN2_MDI3_N
C1253
0.1U/6
R1171
49.9/6/1
R1172
49.9/6/1
C1164
0.01U/6
R1173
49.9/6/1
C1165
0.01U/6
REV:0.5 CHANGE VCC3 TO VCC3_DUAL
VCC2_5DUAL
LINK 10/100,LED IS GREEN,LINK1000,LED IS ORANGE
LAN1_MDI0_N LAN1_MDI1 LAN1_MDI1_N
LAN1_MDI2 LAN1_MDI2_N
LAN1_MDI3_N
C1255
0.1U/6
Title
Size Document Number Rev
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
GIGABIT LAN CONTROLLER
C1155
0.01U/6
LAN2-LINK100_N
R1265 330/6
LANLED_PWR
C1167
0.01U/6
FB48 FB30/8
LANLED_PWR
LAN1-LINK100_NLAN1_MDI3
R1269 330/6
LANLED_PWR
R1170
49.9/6/1
R1178
49.9/6/1
R1169
49.9/6/1
R1264 330/6
LAN2_COMB_ACT_N
LAN2_LINK_UP_N
R1177
49.9/6/1
R1268 330/6
LAN1_COMB_ACT_NLAN1_MDI0 LAN1_LINK_UP_N
31 58Tuesday, October 21, 2003
1.3
5
4
3
2
1
B14 B19 C10
D11 E17
H19 L17
N19 R17
U11 U15 U19
W13 W17
C16
G12 G13 G14
H13 H14
J14
M14
N13 N14
P12 P13 P14
A19
L18
A14 A15 A16
A18
B12 F14 F15 C12 C15 C18 D12 D13 D15 K19
D6
H4
M2
R4 U1
U3 U7
W5 W9
W1
B4 F1
G7 G8 G9
H7 H8
J7
M7
N7 N8
P7 P8 P9
G1 G2 G3
L2 L5
P1 P4 P2 P5 N5
R3 F2
H5
A3
A4
H1
U6B
VDDO3.3 VDDO3.3 VDDO3.3 VDDO3.3 VDDO3.3 VDDO3.3 VDDO3.3 VDDO3.3 VDDO3.3 VDDO3.3 VDDO3.3 VDDO3.3 VDDO3.3 VDDO3.3 VDDO3.3 VDDO3.3 VDDO3.3 VDDO3.3 VDDO3.3 VDDO3.3 VDDO3.3 VDDO3.3 VDDO3.3 VDDO3.3 VDDO3.3
AVDDH3.3 AVDDH3.3
DVDD1.5 DVDD1.5 DVDD1.5 DVDD1.5 DVDD1.5 DVDD1.5 DVDD1.5 DVDD1.5 DVDD1.5 DVDD1.5 DVDD1.5 DVDD1.5 DVDD1.5 DVDD1.5 DVDD1.5 DVDD1.5 DVDD1.5 DVDD1.5 DVDD1.5 DVDD1.5 DVDD1.5 DVDD1.5 DVDD1.5 DVDD1.5
AVDDL2.5A AVDDL2.5A AVDDL2.5A AVDDL2.5A
AVDDL2.5B AVDDL2.5B AVDDL2.5B
SMBCLK SMBDAT SMBALRT#
JTAG_TCK JTAG_TDI JTAG_TDO JTAG_TMS JTAG_TRST#
AUX_PWR CTRL_1.5 CTRL_2.5A CTRL_2.5B
XTAL1
XTAL2
NC NC NC NC NC NC NC NC NC NC NC
82546EB
Gigabit
ETHERN ET
82546EB
(Anvik)
3
GND_00 GND_01 GND_02 GND_03 GND_04 GND_05 GND_06 GND_07 GND_08 GND_09 GND_10 GND_11 GND_12 GND_13 GND_14 GND_15 GND_16 GND_17 GND_18 GND_19 GND_20 GND_21 GND_22 GND_23 GND_24 GND_25 GND_26 GND_27 GND_28 GND_29 GND_30 GND_31 GND_32 GND_33 GND_34 GND_35 GND_36
GND_38 GND_39 GND_40 GND_41 GND_42 GND_43 GND_44 GND_45 GND_46 GND_47 GND_48 GND_49 GND_50 GND_51 GND_52 GND_53 GND_54 GND_55 GND_56 GND_57 GND_58 GND_59 GND_60 GND_61 GND_62 GND_63 GND_64 GND_65 GND_66 GND_67 GND_68 GND_69 GND_70 GND_71 GND_72 GND_73 GND_74 GND_75
CLK_VIEW
TEST#
SDP0 SDP1 SPD6 SPD7
RSVD
NC NC NC NC NC NC NC NC NC NC NC NC NC NC NC NC
A1 A2 A5 B3 B6 B11 B17 C3 D3 D8 D14 E19 F3 G10 G11 H2 H9 H10 H11 H12 H17 J8 J9 J10 J11 J12 J13 K4 K2 K7 K8 K9 K10 K11 K12 K13 K14
L7 L8 L9 L10 L11 L12 L13 L14 L19 M4 E20 M8 M9 M10 M11 M12 M13 N9 N10 N11 N12 N17 P10 P11 R2 R19 U5 U9 U13 U17 V2 W3 W7 W11 W15 W19 K5 A10
P3 B8
G4 G5 E12 E11
R1 L20
J4 J5 F5 F4 F19 F20 G19 G20 J19 J20 M3 N2 A12 A11 K20
R1805 0/6
R1516 1K/6/X
R1811 1K/6
R1810 1K/6
R1804 0/6
VCC3_DUAL
R1806
TP304
0/6/X
Title
Size Document Number Rev
2
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
GIGABIT LAN POWER AND GND
GA-8IPP533
32 58Tuesday, October 21, 2003
1
1.3
VCC3_DUAL
C432 10U/12
C449 1000P/6
VCC1_5DUAL
C554
0.1U/6
C433 10U/12
C450
0.01U/6
C448
0.01U/6
C558 10U/12
I2C_LAN_CLK[51] I2C_LAN_DAT[51]
I2C_LAN_ALERT_N[51]
R307 1K/6
VCC3_DUAL
R308 1K/6
C434 1000P/6
C452 1000P/6
C463
0.01U/6
C447
0.01U/6
C559 10U/12
R306 1K/6/X
C431 10U/12
D D
C441
0.01U/6
C C
VCC2_5DUAL
C553
0.1U/6
B B
TP94
TP96 TP98 TP99 TP100
A A
5
C437
C435
1000P/6
0.01U/6
C455
C453
1000P/6
0.01U/6
C465
C466
1000P/6
0.01U/6
C446
C445
0.01U/6
0.01U/6
C460
C461
10U/12
10U/12
C486
C487
0.01U/6
0.01U/6
I2C_LAN_CLK I2C_LAN_DAT I2C_LAN_ALERT_N
3VSB
C427 22P/6
4
R1513
C438
C440
0.01U/6
1000P/6
C462
C456
1000P/6
0.01U/6
C468
C467
0.01U/6
1000P/6
C444
C443
0.01U/6
0.01U/6
C458
C459
1U/12
1U/12
C492
C491
10U/12
10U/12
R1776 47/6
LAN1_AUX_PWR
10K/6
LAN1_XTAL1
Y1
LAN1_XTAL2
C429
25MHZ
22P/6
5
D D
4
3
2
1
VCC3_DUAL
VCC3_DUAL
R1641
4.7K/6/X
DISABLE_LAN-[31,37,39]
VCC3_DUAL
C C
R1807 22K/6
C1655 1U/8
53
2 4
U173 NC7S14/SOT23-5
53
2 4
U174 NC7S14/SOT23-5
53
U148
1 2
4
P HILIPS-74AHC1G08/SOT23-5
LAN_PWROK [31]
B B
A A
Title
Size Document Number Rev
5
4
3
2
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
GIGABIT LAN POWERGOOD
GA-8IPP533
33 58Tuesday, October 21, 2003
1
1.3
5
D D
5VSB
C C
VCC_DUAL VCC
12
D61
5817/S
4
12
D65
5820/S
3
C532 1000P/6
C533
0.01U/6
VCC_DUAL
680U/6.3V
EC108
Q190
1084/263
3
24
1
C1487
0.1U/6
R1668 100/6/0.5
R1669 165/6/0.5
2
C1494
0.1U/6
C1488
0.1U/6
C1485
0.1U/6
C1486 1U/6
1
VCC3_DUALVCC3_DUAL
12
12
C1489
C1490
10U/12
10U/12
12
12
R1809 510/6/1
R1808 110/6/1
VCC1_5DUAL
12
C1378 1U/6
12
12
C1379
EC99
0.1U/6 560U/4V/8*10.5
Title
Size Document Number Rev
2
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
GIGABIT LAN POWER
GA-8IPP533
1
C1495 100U/1210
34 58Tuesday, October 21, 2003
C1496 100U/1210
1.3
VCC3_DUAL
VCC2_5DUAL
B B
A A
12
5
C1374 22U/12
12
C501
0.1U/6
C1375
0.1U/6
C502
0.1U/6
12
R1577
22.1K/6/0.5
12
R1578 20K/6/0.5
U138
1
EN
GND4
2
VIN
GND3
3
VOUT
GND2
4 5
VADJ GND1
SC1565-2.5v/SMD
8 7 6
82546EB Power Comsuption
Typ Current (mA) VCC3 VCC25 VCC15
240mA 280mA 740mA
2.6W
D3 cold wake enable
4
3V3_SB is about 500mA
C534 1000P/6
Max Current (mA)
265mA 290mA 845mA
3.1W
3
VCC3_DUAL VCC1_5DUAL
2
Q189
1084/252
1
C535
0.01U/6
12
C1376 10U/12
3
5
4
3
2
1
ICH3_AD[0..31][29,36,43]
ICH3_PIRQB_N
ICH3_PIRQD_N[36]
D D
C C
3VSB
THE GPIO CONTROL CHANGE FROM GPIO33 TO GPIO27 FOR 3VSB POWER PLAN.
B B
SMB_MUX_SW[51]
I2C_UNLOCK[40]
ASF_SMBALERT_N[37,51]
A A
ASF_SMBCLK[37,51]
ASF_SMBDAT[37,51]
I2C_MUX_RST#[37]
SMB_MUX_SW
I2C_UNLOCK
ASF_SMBALERT_N
ASF_SMBCLK
ASF_SMBDAT
5
R1585
4.7K/6/X
0/6/X
R1382
R1549 0/6/X
R1661 0/6/X
PCISLOT5_CLK33[46]
ICH3_REQ3_N[36]
ICH3_CBE3_N[29,36,43]
ICH3_CBE2_N[29,36,43] ICH3_IRDY_N[29,36,43] ICH3_DEVSEL_N[29,36,43]
ICH3_PLOCK_N[29,36] ICH3_PERR_N[29,36] ICH3_SERR_N[29,36] ICH3_CBE1_N[29,36,43]
BMC_SMB_DAT[40,51] BMC_SMB_CLK[40,51]
R1383 0/6
VCC3
R1674 0/6/X R1675 0/6
3VSB
2
Q177 2N7002/X
3
1
2
3
ICH3_PIRQD_N PCISLOT5_CLK33 ICH3_REQ3_N
ICH3_AD31 ICH3_AD29 ICH3_AD27 ICH3_AD25
ICH3_CBE3_N
ICH3_AD23 ICH3_AD21 ICH3_AD19
ICH3_AD17 ICH3_CBE2_N ICH3_IRDY_N ICH3_DEVSEL_N
ICH3_PLOCK_N ICH3_PERR_N ICH3_SERR_N ICH3_CBE1_N
ICH3_AD14 ICH3_AD12 ICH3_AD10 ICH3_AD8
ICH3_AD7 ICH3_AD5 ICH3_AD3 ICH3_AD1
R1786
4.7K/6
BMC_SMB_DAT BMC_SMB_CLK
BMC_SMB_ALERT_N
C1288
0.1U/6
BMC_SMB_ALERT_N
Q178 2N7002/X
1
2
Q179 2N7002/X
3
1
4
VCC3
J12
B1
41
B2
42
B3
43
B4
44
B5
45
B6
46
B7
47
B8
48
B9
49
B10
50
B11
51
B12
52
B13
53
B14
54
B15
55
B16
56
B17
57
B18
58
B19
59
B20
60
B21
61
B22
62
B23
63
B24
64
B25
65
B26
66
B27
67
B28
68
B29
69
B30
70
B31
71
B32
72
B33
73
B34
74
B35
75
B36
76
B37
R1758
4.7K/6
19 18 17
20
10
U129
SDA SCL INT#
3
A2
2
A1
1
A0
VDD
VSS
PCA9544
B38 B39 B40
77 78 79 80
32BIT PCI CONN
3VSB
-12V
3VSB
SMBus Addrss = E2h
1 1 1 0 A2 A1 A0 R/W
BMC_SMB_CLK
BMC_SMB_DAT
SD0 SC0
INT0#
SD1 SC1
INT1#
SD2 SC2
INT2#
SD3 SC3
INT3#
VCC
ICH3_PIRQA_N
A1
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
5 6 4
8 9 7
12 13 11
15 16 14
A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 A17 A18 A19 A20 A21 A22 A23 A24 A25 A26 A27 A28 A29 A30 A31 A32 A33 A34 A35 A36 A37 A38 A39 A40
3VSB
3
R1331
4.7K/6
R1337
4.7K/6
ICH3_PIRQC_N ICH3_PCIRST_N ICH3_GNT3_N
ICH3_PME_N ICH3_AD30 ICH3_AD28 ICH3_AD26
ICH3_AD24 32B_IDSEL1 ICH3_AD22 ICH3_AD20
ICH3_AD18 ICH3_AD16 ICH3_FRAME_N ICH3_TRDY_N
ICH3_STOP_N ICH3_PAR ICH3_AD15 ICH3_AD13
ICH3_AD11 ICH3_AD9 ICH3_CBE0_N ICH3_AD6
ICH3_AD4 ICH3_AD2 ICH3_AD0
3VSB
+12V
R1332
4.7K/6
R1338
4.7K/6
3VSB
ICH3_PIRQA_N [24,36]ICH3_PIRQB_N[36] ICH3_PIRQC_N [36,43] ICH3_PCIRST_N [29,36,37,39,43,48,51] ICH3_GNT3_N [36]
ICH3_PME_N [27,28,31,36,51]
R1699 100/6
ICH3_FRAME_N [29,36,43] ICH3_TRDY_N [29,36,43]
ICH3_STOP_N [29,36,43] ICH3_PAR [29,36,43]
ICH3_CBE0_N [29,36,43]
PCISLOT5_CLK33
C1346
10P/6
5VSB
R1333
R1336
4.7K/6
4.7K/6
R1340
R1339
4.7K/6
4.7K/6
3VSB
R1341
4.7K/6
R1334
4.7K/6
ICH3_AD26
R1335
4.7K/6
R1342
4.7K/6
I2C_BUS0_DAT [5,7,39] I2C_BUS0_CLK [5,7,39] CPU_SMBALERT_N [5,7,37]
I2C_BUS1_DAT [29,49] I2C_BUS1_CLK [29,49] I2C_BUS1_ALERT# [49]BMC_I2CRST#[40]
I2C_BUS2_DAT [27,28] I2C_BUS2_CLK [27,28]
2
R1863 0/6
R1862 0/6
Title
Size Document Number Rev
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
I2C MUX AND 32 BIT PCI CONN
GA-8IPP533
I2C_BUS3_DAT [29] I2C_BUS3_CLK [29]
1
35 58Tuesday, October 21, 2003
1.3
5
4
3
VCC3
V_CORE
2
1
VCC3
RN186
2 4 6 8
8P-8.2K
RN187
2 4 6 8
8P-8.2K
RN218
1 3 5
7
8P-8.2K RN183
12
34
56
78
8P4R-8.2K R489
8.2K/6 RN188
1
3
5
7
8P-8.2K
SIO_SMI_N[39] SIO_PME_N[39]
ICH3_GNTA_N
ICH3_TRDY_N ICH3_STOP_N ICH3_SERR_N ICH3_REQ3_N
ICH3_DEVSEL_N ICH3_PERR_N ICH3_PLOCK_N ICH3_IRDY_N
ICH3_FRAME_N ICH3_REQ1_N ICH3_REQ4_N ICH3_PIRQB_N
ICH3_PIRQF_N ICH3_PIRQE_N
ICH3_PIRQG_N
GN+
ICH3_REQ0_N
ICH3_PIRQA_N ICH3_PIRQC_N ICH3_PIRQD_N ICH3_REQ2_N
ICH3_PME_N
R472
2.2K/6/X
R433
8.2K/6
SIO_SMI_N SIO_PME_N
3VSB
1 3 5
VCC3
3VSB
R1790 10K/6
7
1 3 5 7
2 4 6 8
2 4 6 8
D D
C C
B B
Strap For ''Top Block Swap" Function
3VSB
NMI SWITCH
NMI_SW[29]
A A
NMI_SW
R1586
4.7K/6
C1371
0.1U/6
5
3VSB
53
3VSB
2 4
U169
NC7S14/SOT23-5
24
VCC3
R434
8.2K/6
U143
53
NC7S14/SOT23-5
REV:0.4 ADD U169
R1887
100K/6
ICH3_AD[0..31][29,35,43]
ICH3_CBE0_N[29,35,43] ICH3_CBE1_N[29,35,43] ICH3_CBE2_N[29,35,43] ICH3_CBE3_N[29,35,43]
ICH3_DEVSEL_N[29,35,43] ICH3_FRAME_N[29,35,43] ICH3_IRDY_N[29,35,43] ICH3_TRDY_N[29,35,43] ICH3_STOP_N[29,35,43]
ICH3_PAR[29,35,43]
ICH3_PERR_N[29,35]
ICH3_CLK33[46]
ICH3_PCIRST_N[29,35,37,39,43,48,51]
ICH3_PLOCK_N[29,35] ICH3_SERR_N[29,35]
ICH3_PME_N[27,28,31,35,51]
ICH3_REQ0_N[43] ICH3_REQ1_N[29] ICH3_REQ2_N[29] ICH3_REQ3_N[35]
ICH3_GNT0_N[43] ICH3_GNT1_N[29] ICH3_GNT2_N[29] ICH3_GNT3_N[35]
TP385
TO ICH3 GPIO8 TO REQUEST NMI FROM NMI SWITCH WHEN NOT INSTALL IPMI.
NMI_SW_IN
BMC_NMI_OUT [51]
REV:0.5 ADD R1887
NMI_SW_IN [37]
4
ICH3_AD0 ICH3_AD1 ICH3_AD2 ICH3_AD3 ICH3_AD4 ICH3_AD5 ICH3_AD6 ICH3_AD7 ICH3_AD8 ICH3_AD9 ICH3_AD10 ICH3_AD11 ICH3_AD12 ICH3_AD13 ICH3_AD14 ICH3_AD15 ICH3_AD16 ICH3_AD17 ICH3_AD18 ICH3_AD19 ICH3_AD20 ICH3_AD21 ICH3_AD22 ICH3_AD23 ICH3_AD24 ICH3_AD25 ICH3_AD26 ICH3_AD27 ICH3_AD28 ICH3_AD29 ICH3_AD30 ICH3_AD31
ICH3_CBE0_N ICH3_CBE1_N ICH3_CBE2_N ICH3_CBE3_N
ICH3_DEVSEL_N ICH3_FRAME_N ICH3_IRDY_N ICH3_TRDY_N ICH3_STOP_N ICH3_PAR ICH3_PERR_N ICH3_CLK33 ICH3_PCIRST_N ICH3_PLOCK_N ICH3_SERR_N ICH3_PME_N ICH3_REQA_N ICH3_REQ5_REQB_N ICH3_GNTA_N
TP228
ICH3_REQ0_N ICH3_REQ1_N ICH3_REQ2_N ICH3_REQ3_N ICH3_REQ4_N ICH3_GNT0_N ICH3_GNT1_N ICH3_GNT2_N ICH3_GNT3_N ICH3_GNT4_N
ICH3_LINT1_NMI
U23A
J2
AD0
K1
AD1
J4
AD2
K3
AD3
H5
AD4
K4
AD5
H3
AD6
L1
AD7
L2
AD8
G2
AD9
L4
AD10
H4
AD11
M4
AD12
J3
AD13
M5
AD14
J1
AD15
F5
AD16
N2
AD17
G4
AD18
P2
AD19
G1
AD20
P1
AD21
F2
AD22
P3
AD23
F3
AD24
R1
AD25
E2
AD26
N4
AD27
D1
AD28
P4
AD29
E1
AD30
P5
AD31
K2
CBE0_N
K5
CBE1_N
N1
CBE2_N
R2
CBE3_N
M3
DEVSEL_N
F1
FRAME_N
N3
IRDY_N
H1
TRDY_N
H2
STOP_N
G5
PAR
M2
PERR_N
T5
PCICLK
Y1
PCIRST_N
M1
PLOCK_N
L5
SERR_N
W1
PME_N
C4
REQA_N_GPIO0
D4
REQ5_N_REQB_N_GPIO1
B6
GNTA_N_GPIO16
B3
GNT5_N_GNTB_N_GPIO17
D3
REQ0_N
F4
REQ1_N
A3
REQ2_N
R4
REQ3_N
E4
REQ4_N
A4
GNT0_N
E3
GNT1_N
D2
GNT2_N
D5
GNT3_N
B4
GNT4_N
R1763
470/6/X
3
2
1
3VSB
R1760 1K/6/X
Q183 2N2222/X
NMI_SW_IN
PIRQE_GPIO2 PIRQF_GPIO3
PIRQG_GPIO4
PIRQH_GPIO5
2
3
A20M_N
CPUSLP_N
FERR_N
IGNNE_N
INIT_N
INTR_N
NMI
SMI_N
STPCLK_N
RCIN_N
A20GATE
CPUPWRGD
DPSLP_N
HI0 HI1 HI2 HI3 HI4 HI5 HI6 HI7 HI8
HI9 HI10 HI11
PSTRBS PSTRBF HICOMP
HITERM
HIREF
SERIRQ PIRQA_N PIRQB_N PIRQC_N PIRQD_N
IRQ14 IRQ15
APICCLK
APICD0 APICD1
EE_SHCLK
EE_DIN
EE_DOUT
EE_CS
LANCLK
LANRXDO
LANRXD1 LANRXD2
LANRSTSYNC
LANTXD0 LANTXD1 LANTXD2
R1761
4.7K/6/X
BMC_NMI_IN
3
Q184 2N2222/X
1
R1882
0/6
U23
R427
8.2K/6
V23 W21 J22 AA21 AB23 AA23 Y21 Y23 U23 U22 Y22 W23 AB22
L22 M21 M23 N20 P21 R22 R20 T23 M19 P19 N19 R19 N22 P23 K19 L19 L20
H22 B1 C1 B2 A2 AB14 W19 J19 J20 J21 A6 B5 C5 A5
D10 D8 E8 E9
C9 C8 A8 A9 D7 B9 C10 A10
R425
8.2K/6
R428
8.2K/6
ICH3_DPSLP_N
ICH3_HI0 ICH3_HI1 ICH3_HI2 ICH3_HI3 ICH3_HI4 ICH3_HI5 ICH3_HI6 ICH3_HI7 ICH3_HI8 ICH3_HI9 ICH3_HI10 ICH3_HI11 ICH3_PSTRBS ICH3_PSTRBF ICH3_HICOMP ICH3_HITERM ICH3_HIREF
ICH3_SERIRQ ICH3_PIRQA_N ICH3_PIRQB_N ICH3_PIRQC_N ICH3_PIRQD_N IRQ14 IRQ15 ICH3_APICCLK ICH3_APICD0 ICH3_APICD1 ICH3_PIRQE_N ICH3_PIRQF_N ICH3_PIRQG_N GN+
TP229 TP230
TP231 TP232
TP233 TP234 TP235 TP236 TP237 TP238 TP239 TP240
BMC_NMI_IN [51]
R823 200/6
ICH3_A20M_N ICH3_CPUSLP_N FERR_N ICH3_IGNNE_N ICH3_INIT_N ICH3_LINT0_INTR ICH3_LINT1_NMI ICH3_SMI_N ICH3_STPCLK_N ICH3_RCIN_N ICH3_A20GATE I CH3_CPUPWRGD
TP227
ICH3_HI[0..11]
ICH3_PSTRBS [11] ICH3_PSTRBF [11]
ICH3_SERIRQ [39,51] ICH3_PIRQA_N [24,35] ICH3_PIRQB_N [35] ICH3_PIRQC_N [35,43] ICH3_PIRQD_N [35] IRQ14 [29] IRQ15 [37]
GN+ [29,42]
ICH3_PIRQE_N [29] ICH3_PIRQF_N [29]
ICH3_PCIRST_N
ICH3_A20M_N [5,6,7] ICH3_CPUSLP_N [5,6,7] FERR_N [5,7] ICH3_IGNNE_N [5,6,7] ICH3_INIT_N [5,6,7,37] ICH3_LINT0_INTR [5,6,7] ICH3_LINT1_NMI [6] ICH3_SMI_N [6,9] ICH3_STPCLK_N [6] ICH3_RCIN_N [39] ICH3_A20GATE [39] ICH3_CPUPWRGD [5,7]
ICH3_HI[0..11] [11]
VCC1_8
R435 10K/6
VCC3
147
U24A
2 3
74LVC125
1
VCC3
147
5 6
2
VCC1_8
R429 825/6/1
C740
0.01U/6
C739
0.1U/6
C741
0.1U/6
R431 261/6/1
R432 261/6/1
R430
78.7/6/1
R436 10K/6
R437 0/6
C738
0.01U/6
REV:1.2 ADD R1917,R1918
U24D
74LVC125
13
VCC3
R438
4.7K/6
GA-8IPP533
1
PCIRST_2_N [24]
TO P64H2
VCC3
R1917
4.7K/6
R1918 10/6
VCC2_5
U24B
74LVC125
4
Title
Size Document Number Rev
Date: Sheet of
VCC3
147
12 11
R439
4.7K/6
PCIRST2_5_N [11,15,16,19,20]
TO MCH
GIGA-BYTE TECHNOLOGY CO., LTD.
ICH3 HUB AND PCI INTERFACE
36 58Tuesday, October 21, 2003
1.3
5
REV:0.5 ADD R1897,R1898,R1899,R1900,R1901,R1902
CPU_SMBALERT_N[5,7,35]
D D
3VSB
R1727 10K/6
C C
3VSB 3VSB VCC3
R1121
10K/6
BMC_SCI_N ICH3_SAFE_MODE
ICH3_GPIO320ICH3_GPIO33
0
RX200 RX200A 0 01
B B
PROTECTION MODE
A A
TOP BLOCK PROTECT
BLOCK 2-8 PROTECT
ALL BLOCKS
WRITE ENABLE
ALL BLOCKS WRITE DISABLE
ICH3_SMBDATA[11,15,16,19,20,24,46]
M/B ID
WP Jumper Setting
Jumper 1-2 SHORT,
3-4 SHORT
R442 0/6/X
ICH3_SMBCLK[11,15,16,19,20,24,46]
R1901 0/6/X
+12V
R1902 0/6
VCC
ICH3_SMBDATA ASF_SMBDAT
R443
4.7K/6
R1529
10K/6
BMC_SMI_N
ICH3_GPIO36
0
JP2
1 2 3 4
H1X4
3-4 SHORT 1-2 SHORT
NO
5
R1897 0/6/X
+12V
R1898 0/6
VCC
+12V
VCC
3VSB3VSB 3VSB
R444
4.7K/6
FWH_J4BIT_1
R450 100/6
ICH3_SMBALERT_N
R1899 0/6/X R1900 0/6
ICH3_SMBCLK ASF_SMBCLK
1
R441
4.7K/6
4.7K/6/X
1
1
2
Q174 2N7002
3
ASF_SMBALERT_N ASF_SMBCLK
ASF_SMBDATNMI_SW_IN
R470
2.2K/6/X
R1868
R1867
4.7K/6/X
R1871
R1870
4.7K/6
4.7K/6
R446 100/6
+12V
ICH3_GPO22 ICH3_GPO23
0
1
1
0
1 1
0 0
VCC3
2
2
R1869
4.7K/6/X
R1872
4.7K/6
R459
10K/6
R451 10K/6
DISABLE_LAN-[31,33,39]
Q172 2N7002
ASF_SMBALERT_N
3
Q173 2N7002
3
VCC3
R1839
8.2K/6
IC3_GPI0_6
ICH3_GPIO32 ICH3_GPIO33 ICH3_GPIO36
2
VCC3
4
3VSB
53
R1924 0/6/X
3VSB
R1923 10K/6
LAN_DISABLE
VCC3VCC3
R447
4.7K/6
FWH_CLK33[46]
ICH3_LFRAME_N[39,51]
Q14 2N7002
3 1
C1031
0.1U/6
4
ASF_SMBALERT_N[35,51]
ASF_SMBCLK[35,51] ASF_SMBDAT[35,51]
U175 NC7S14/SOT23-5/X
24
3VSB
R448
4.7K/6
C1032
0.1U/6
V_BAT[38,39]
ICH3_THRM_N[39]
ICH3_INTRUDER_N[39]
LAN_DISABLE FWH_WP_N FWH_TBL_N
REQUEST NMI FROM NMI SWITCH WHEN NOT INSTALL IPMI.
RN184
1 2 3 4 5 6 7 8
8P4R-10K
FWH_WP_N
FWH_TBL_N
FWH_IC
R449 100/6
C1033
0.1U/6
VCC3
ICH3_INTRUDER_N ASF_SMBALERT_N ASF_SMBCLK ASF_SMBDAT
RST_IPMI#[51]
I2C_MUX_RST#[35]
ICH_SYSEVENT_N[41]
R1865 0/6 R1866 0/6
CPU1_DISABLE_N[9] CPU0_DISABLE_N[9]
BMC_SMI_N[51] BMC_SCI_N[51]
NMI_SW_IN[36]
PD_80P[29]
ICH3_USBP0P[47] ICH3_USBP0N[47] ICH3_USBP1P[47] ICH3_USBP1N[47] ICH3_USBP2P[47] ICH3_USBP2N[47] ICH3_USBP3P[47] ICH3_USBP3N[47]
ICH3_USB_OC0_N[47]
ICH3_USB_OC2_N[47]
CPU0_604_PRT#[5] CPU1_604_PRT#[7]
EXTSMI3_N[29]
BIOS_RECOVERY_N[51]
R445
18.2/6/1
U25
7
WP
8
TBL
29
IC
2
RST
31
CLK
23
FWH4
1
VPP
27
VCCA
32
VCC0
25
VCC1
28
GNDA
16
GND0
26
GND1
SST49LF004A_4M
3
R440 1M/6 R1328 1K/6
ICH3_THRM_N
R1778 47/6 R1779 47/6
RST_IPMI#
R1660 0/6
ICH3_GPO23
ICH3_GPO22 CPU1_DISABLE_N CPU0_DISABLE_N
TP249
IPMI_BT_IRQ_N
TP250
BMC_SMI_N BMC_SCI_N
NMI_SW_IN
PD_80P
IC3_GPI0_6
TP251 TP252 TP253
ICH3_SAFE_MODE
TP254 TP255
ICH3_USBP0P
ICH3_USBP0N
ICH3_USBP1P
ICH3_USBP1N
ICH3_USBP2P
ICH3_USBP2N
ICH3_USBP3P
ICH3_USBP3N
TP256 TP257 TP258 TP259
ICH3_USB_OC0_N
ICH3_USB_OC2_N
ICH3_USB_OC4_N
ICH3_USB_OC5_N
ICH3_GPIO32
ICH3_GPIO33
ICH3_GPIO36
BIOS_RECOVERY_N
TP269 TP270 TP271
ICH3_USB_RBIAS
RY_BY_RFU
FIRMWARE HUB
3
FWH0 FWH1 FWH2 FWH3
DQ4_RFU DQ5_RFU DQ6_RFU DQ7_RFU
FGPI4 FGPI3 FGPI2 FGPI1 FGPI0
INIT
2
U23B
U5
THRM_N
AC3
SMLINK0
AB2
SMLINK1
Y6
INTRUDER_N
AC5
SMBALERT_N_GPIO11
AC4
SMBCLK
AB5
SMBDATA
Y3
GPIO28
W4
GPIO27
W3
GPIO25
AC2
GPIO24
U20
GPIO23
Y20
GPIO22
V5
GPIO21
V21
GPIO20
W20
GPIO19
U21
GPIO18
Y2
GPIO13
Y4
GPIO12
W2
GPIO8
V2
GPIO7
V4
GPIO6
D11
AC_RST_N
A7
AC_SYNC
B7
AC_BIT_CLK
C7
AC_SDATA_OUT
B11
AC_SDATA_IN0
C11
AC_SDATA_IN1
D19
USBP0P
D18
USBP0N
A19
USBP1P
A18
USBP1N
E17
USBP2P
E16
USBP2N
B17
USBP3P
B16
USBP3N
D15
USBP4P
D14
USBP4N
A15
USBP5P
A14
USBP5N
E12
OC0_N
D12
OC1_N
C12
OC2_N
B12
OC3_N
A12
OC4_N
A11
OC5_N
H20
USBLEDA0_N_GPIO32
G22
USBLEDA1_N_GPIO33
F21
USBLEDA2_N_GPIO34
G19
USBLEDA3_N_GPIO35
E22
USBLEDA4_N_GPIO36
E21
USBLEDA5_N_GPIO37
H21
USBLEDG0_N_GPIO38
G23
USBLEDG1_N_GPIO39
F23
USBLEDG2_N_GPIO40
G21
USBLEDG3_N_GPIO41
D23
USBLEDG4_N_GPIO42
E23
USBLEDG5_N_GPIO43
B21
USBRBIAS
U23
ICH3_LAD0
13
ICH3_LAD1
14
ICH3_LAD2
15
ICH3_LAD3
17 18
19 20 21 22
FWH_FGP_14
30
FWH_FGP_13
3
FWH_FGP_12
4
FWH_FGP_11
5
FWH_FGP_10
6
FWH_INIT_N
24
9
ID3
10
ID2
11
ID1
12
ID0
PIDRDY_PDRSTB_PWDMARDY_N
PDIOR_N_PDWSTB_PRDMARDY_N
SIORDY_SDRSTB_SWDMARDY_N
SDIOR_N_SDWSTB_SRDMARDY_N
ICH3_LAD0 [39,51] ICH3_LAD1 [39,51] ICH3_LAD2 [39,51] ICH3_LAD3 [39,51]ICH3_PCIRST_N[29,35,36,39,43,48,51]
TP272 TP273 TP274 TP275 TP276
R454 4.7K/6 R455 4.7K/6 R456 4.7K/6 R457 4.7K/6 R458 4.7K/6
TP277 TP278 TP279 TP280
LDRQ0_N LDRQ1_N
LFRAME_N
LAD0 LAD1 LAD2 LAD3
PDDREQ
PDDACK_N
PDIOW_N_PDSTOP
PDCS1_N PDCS3_N
PDA0 PDA1
PDA2 PDD0 PDD1 PDD2 PDD3 PDD4 PDD5 PDD6 PDD7 PDD8 PDD9
PDD10 PDD11 PDD12 PDD13 PDD14 PDD15
SDDREQ
SDDACK_N
SDIOW_N_SDSTOP
SDCS1_N SDCS3_N
SDA0
SDA1
SDA2 SDD0 SDD1 SDD2 SDD3 SDD4 SDD5 SDD6 SDD7 SDD8 SDD9
SDD10 SDD11 SDD12 SDD13 SDD14 SDD15
VCC3
2
T2 U4 U1 V1 U3 T3 U2
AB12 Y13 AB13 AC13 Y12 AC15 AB15 AA14 AC14 AA15 W12 AB11 AA10 AC10 W11 Y9 AB9 AA9 AC9 Y10 W9 Y11 AB10 AC11 AA11 AC12
AB18 Y19 AB19 AC19 AA18 AC21 AC22 AC20 AA19 AB20 Y17 W17 AC17 AB16 W16 Y14 AA13 W15 W13 Y16 Y15 AC16 AB17 AA17 Y18 AC18
ICH3_LDRQ0_N ICH3_LDRQ1_N ICH3_LFRAME_N ICH3_LAD0 ICH3_LAD1 ICH3_LAD2 ICH3_LAD3
ICH3_PDDREQ ICH3_PDDACK_N ICH3_PDIRDY_N ICH3_PDIOR_N ICH3_PDIOW_N ICH3_PDCS1_N ICH3_PDCS3_N ICH3_PDA0 ICH3_PDA1 ICH3_PDA2 ICH3_PDD0 ICH3_PDD1 ICH3_PDD2 ICH3_PDD3 ICH3_PDD4 ICH3_PDD5 ICH3_PDD6 ICH3_PDD7 ICH3_PDD8 ICH3_PDD9 ICH3_PDD10 ICH3_PDD11 ICH3_PDD12 ICH3_PDD13 ICH3_PDD14 ICH3_PDD15
ICH3_SDDREQ ICH3_SDIRDY_N
Q13 2N2222
R1612 4.7K/6/X
VCC3
R452 300/6
3
2
1
Q114 2N2222
Title
Size Document Number Rev
Date: Sheet of
VCC3
ICH3_LDRQ0_N [39] ICH3_LDRQ1_N [51]
ICH3_LFRAME_N [39,51]
ICH3_LAD[0..3]
ICH3_PDDREQ [29] ICH3_PDDACK_N [29] ICH3_PDIRDY_N [29] ICH3_PDIOR_N [29] ICH3_PDIOW_N [29] ICH3_PDCS1_N [29] ICH3_PDCS3_N [29] ICH3_PDA0 [29] ICH3_PDA1 [29] ICH3_PDA2 [29]
ICH3_PDD[0..15]
ICH3_SDDREQ ICH3_SDIRDY_N
IRQ15[36]
R453 470/6
3
1
IRQ15
BIOS RECOVERY JUMPER,REV:0.5 ADD
VCC3
R1791
4.7K/6
BIOS_RECOVERY_N
R1329
2
470/6
GIGA-BYTE TECHNOLOGY CO., LTD.
ICH3 IDE USB AND FWH
1
ICH3_LAD[0..3] [39,51]
ICH3_PDD[0..15] [29]
VCC3 VCC3
R499 10K/6
ICH3_INIT_N [5,6,7,36]
GA-8IPP533
1
R1413
R1330
4.7K/6
4.7K/6
VCC3
J37
1 2 3
H1X3/RED
DEFAULT 2-3 CLOSE
37 58Tuesday, October 21, 2003
1.3
5
D D
ICH3_SLP_S5_N[39,49]
CLEAR_CMOS[40]
DEFAULT 2-3 SHORT
R1663 1K/6/X
RTCRST_PD
CLR_CMOS
R461
1
1K/6
2 3
H1X3/BLUE
C753 1U/6
R463 10K/6
RTCVDD
C C
KEEP V_BAT TRACE AS WIDE AS POSSIBLE.
V_BAT[37,39]
3VSB
D40
RB751V-40/S
VBAT_ADM
12
12
RB751V-40/S
BT1
R464
1K/6
D39
RB751V-40/S
1 2
C761
0.047U/6
D38
1 2
BATTERY
R467 10M/6
B B
A A
ICH3_RTCX2
C771 15P/6
Y3
1 2
32.768KHz
ICH3_RTCX1
C772 15P/6
C760
4.7U/8
R468
10M/6
4
ICH3_CLK14[46] ICH3_CLK48[46] ICH3_CLK66[46]
R1285 0/6
ICH3_SLP_S3_N[39,46] ICH3_PWROK[11,31,48]
ICH3_PWRBNIN_N[39]
ICH3_RI_N[39,42] ICH3_RSMRST_N[49]
TP381
ICH3_VRMPWRGD[48,50]
R462 10K/6
ICH3_SPKR[42]
1 2
VCC3
ICH3_RSMRST_N
R1840 10K/6/X
R465 10K/6
D37
5817/S
ICH3_CLK14 ICH3_CLK48 ICH3_CLK66
ICH3_SLP_S3_N
ICH3_PWROK ICH3_PWRBNIN_N ICH3_RI_N ICH3_RSMRST_N
ICH3_VRMPWRGD
ICH3_LAN_RST_N
ICH3_RTCRST_IN
ICH3_RTCX1 ICH3_RTCX2 ICH3_VBAIS
ICH3_SPKR ICH3_OPRSLPVR
ICH3_TP0
R466 10K/6
3VSB
C766
0.1U/6
VCC
R469 1K/6
V5REF1_2
C777
1U/6
5VSB
VCC3
R946 10K/6
3VSB
R460 10K/6
U23C
J23
CLK14
F20
CLK48
T19
CLK66
AA5
SLP_S3_N
AA2
SLP_S5_N
AA6
PWROK
AB1
PWRBTN_N
AA1
RI_N
AA7
RSMRST_N
AB4
SUS_STAT_N
AA4
SUSCLK
V19
VRMPWRGO
Y5
LAN_RST_N
AB6
VCC_RTC
Y7
RTCRST_N
AC7
RTCX1
AC6
RTCX2
AB7
VBIAS
H23
SPKR
AB21
OPRSLPVR
AB3
TPO
C13
VSREF_SUS1
W5
VSREF_SUS2
E6
V5REF1
W8
V5REF2
C2
NC5
T1
NC4
D6
NC3
T21
NC2
E7
NC1
ICH3 U23
C1621
0.1U/6/X
3
VCCSUS1_8_10 VCCSUS1_8_11
VCCSUS1_8_12 VCCSUS1_8_13
VCC3_3_1 VCC3_3_2 VCC3_3_3 VCC3_3_4 VCC3_3_5 VCC3_3_6 VCC3_3_8 VCC3_3_7
VCC3_3_9 VCC3_3_10 VCC3_3_11 VCC3_3_12 VCC3_3_13 VCC3_3_14 VCC3_3_15
VCC1_8_1
VCC1_8_2
VCC1_8_3
VCC1_8_4
VCC1_8_5
VCC1_8_6
VCC1_8_7
VCC1_8_8
VCC1_8_9 VCC1_8_10 VCC1_8_11 VCC1_8_12
VCCSUS3_3_1 VCCSUS3_3_2 VCCSUS3_3_3 VCCSUS3_3_4 VCCSUS3_3_5 VCCSUS3_3_6
VCCSUS3_3_7 VCCSUS3_3_8
VCCSUS1_8_1 VCCSUS1_8_2 VCCSUS1_8_3 VCCSUS1_8_4 VCCSUS1_8_5 VCCSUS1_8_6 VCCSUS1_8_7 VCCSUS1_8_8 VCCSUS1_8_9
V_CPU_IO_1 V_CPU_IO_2 V_CPU_IO_3
F6 G6 H6 J6 M10 R6 U6 T6 G18 H18 P12 V15 V16 V17 V18
J18 M14 R18 T18 U19 E11 K6 K18 P6 P18 V10 V14
F17 F18 K14 E10 V8 V9
F9 F10
F15 F16 B23 C23 E13 F14 K12 P10 V6 V7
F7 F8 K10
P14 U18 V22
C742
0.1U/6
C754
0.1U/6
0.1U/6
0.1U/6
C762
0.1U/6
C767
C773
C743
0.1U/6
C755
0.1U/6
0.1U/6
0.1U/6
C763
C768
0.1U/6
C774
C744
0.1U/6
C756
0.1U/6
0.1U/6
0.1U/6
0.1U/6
C764
C769
C775
2
C745
0.1U/6
C757
0.1U/6
3VSB
10U/12
1_8SB
10U/12
V_CORE
10U/12
C765
C770
C776
C746
0.1U/6
C758
0.1U/6
0.1U/6
VCC1_8
10U/12
C747
C759
C748
0.1U/6
A13 A16 A17 A20 A21 A22 A23
B10 B13 B14 B15 B18 B19 B20 B22
C14 C15 C16 C17 C18 C19 C20 C21 C22
D13 D16 D17 D20 D21 D22
E14 E15 E18 E19 E20 F19 F22
G20
H19 K20
K21 K22 K23
1
VCC3
C750
C749
0.1U/6
0.1U/6
U23D
A1
GND0 GND1 GND2 GND3 GND4 GND5 GND6 GND7
B8
GND8 GND9 GND10 GND11 GND12 GND13 GND14 GND15 GND16
C3
GND17
C6
GND18 GND19 GND20 GND21 GND22 GND23 GND24 GND25 GND26 GND27
D9
GND28 GND29 GND30 GND31 GND32 GND33 GND34
E5
GND35 GND36 GND37 GND38 GND39 GND40 GND41 GND42
G3
GND43 GND44 GND45
J5
GND46 GND47 GND48 GND49 GND50
L3
GND51
ICH3
C751
0.1U/6
GND52 GND53 GND54 GND55 GND56 GND57 GND58 GND59 GND60 GND61 GND62 GND63 GND64 GND65 GND66 GND67 GND68 GND69 GND70 GND71 GND72 GND73 GND74 GND75 GND76 GND77 GND78 GND79 GND80 GND81 GND82 GND83 GND84 GND85 GND86 GND87 GND88 GND89 GND90 GND91 GND92 GND93 GND94 GND95 GND96 GND97 GND98
GND99 GND100 GND101 GND102 GND103
C752
10U/12
U23
L21 L23 M20 M22 N5 N21 N23 P20 P22 R3 R5 R21 R23 T4 T20 T22 V3 V20 W6 W7 W10 W14 W18 W22 Y8 AA3 AA8 AA12 AA16 AA20 AA22 AB8 AC1 AC8 AC23 K11 K13 L10 L11 L12 L13 L14 M11 M12 M13 N10 N11 N12 N13 N14 P11 P13
Title
Size Document Number Rev
5
4
3
2
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
ICH3 POWER AND GND
GA-8IPP533
38 58Tuesday, October 21, 2003
1
1.3
5
VCC VCC3VCC33VSB3VSB
R1429
R1531
10K/6
4.7K/6
D D
CASE_OPEN1[28,40,49]
C C
B B
R1367 10K/6/X
DTR1
R1369 10K/6
A A
R935 10K/6
VCC3VCC3
R937
4.7K/6
R1433
0/6
CASEOPEN
1 2
H1X2/X
CASE OPEN
R941
4.7K/6
R942
4.7K/6/X
5
WDO#
R938
4.7K/6
I2C_SIO_CLK I2C_SIO3_DAT CIRRX ICH3_PWRBNIN_N CHASO
R1162 0/6
R1278 0/6/X
VCC3VCC3
R1377
R1376
10K/6
10K/6
ICH3_A20GATE ICH3_RCIN_N
R1922 0/6
CASEOPEN
ICH3_INTRUDER_N [37]
DCD2[41] DSR2[41]
RXD2[41] RTS2[41]
TXD2[41] CTS2[41] DTR2[41]
KB_CLK[42]
KB_DATA[42]
MS_CLK[42]
MS_DATA[42]
CPU0_LED[29] CPU1_LED[29]
4
DISABLE_LAN- [31,33,37]
DCD1[41] DSR1[41]
RXD1[41] RTS1[41]
TXD1[41] CTS1[41] DTR1[41]
RI1[41]
RI2[41]
VCC3
SYS_LED[29]
ICH3_RCIN_N[36]
ICH3_A20GATE[36]
ICH3_PCIRST_N[29,35,36,37,43,48,51]
SIO_CLK33[46]
ICH3_SERIRQ[36,51]
ICH3_LDRQ0_N[37]
ICH3_LFRAME_N[37,51]
ICH3_LAD0[37,51] ICH3_LAD1[37,51] ICH3_LAD2[37,51] ICH3_LAD3[37,51]
4
U87
103
DCD2#
104
DSR2#
105
SIN2
106
RTS2#
107
SOUT2/PSLDC1
108
CTS2#
109
DTR2#/PSONPOL
110
RI2#
111
KBCLK
112
KBDAT
113
MCLK
114
MDAT
115
VDD
116
VSS
117
GPIO20/JOYAX
118
GPIO21/JOYAY
119
GPIO22/JOYABTN0
120
GPIO23/JOYABTN1
121
GPIO24/JOYBX
122
GPIO25/JOYBY
123
GPIO26/JOYBBTN0
124
GPIO27/JOYBTN1
125
GPIO30/MDTX
126
GPIO31/MDRX
127
GPIO32/P16/IRSL1
128
GPIO33/FANIN2
ICH3_RCIN_N ICH3_A20GATE
3
VCC3
C780
2.2U/12
VCC3
102
101
10099989796959493929190898887868584838281807978777675747372717069686766
PD0
PD1
PD2
PD3
PD4
RI1#
CTS1#
BADDR/DTR1#
SOUT1/PSLDC0
SIN1
DSR1#
DCD1#
TEST/RTS1#
STB#_WRITE#
ERR#
AFD#_DSTRB#
INIT#
SLIN#_ASTRB#
VSS
VDD
PD5
PD6
PD7
PE
ACK#
SLCT
BUSY_WAIT#
INDEX#
MTR0#
DENSEL
DRATE0
GPIO17/IRSL3/DR1#
DR0#
IRSL2/GPIO16/MTR1#
PC87366/VLA
FANOUT2/GPIO34
GPIO0/FANIN1
GPIO1/FANOUT1
GPIO2/FANIN0
GPIO3/FANOUT0
GPIO4/P12
GPIO5/P17
KBRST/GPIO6
GA20/GPIO7
LRESET#
LCLK
SERIRQ
LDRQ#
LFRAME#
LAD0
LAD1
LAD2
LAD3
VSS
VDD
SMI#/GPIO10
CLKI
GPIOE0
OTS1#/GPIOE1
OTS2#/GPIOE2/LED1
GPIOE3/LED2
RING#/ALARM#GPIOE4
CHASO#/GPIOE5
CHASI
VBAT
VSB
PWUREQ#
PWBTOUT#/GPOS0
PSON/GPOS1
12345678910111213141516171819202122232425262728293031323334353637
OD OUTPUT FROM BMC
B MC_PWR_SW_OUT_N[51]
FROM SIO PWRBTN OUT TO BMC
IPMI_PWRBT_IN_N[51]
VCC3
3VSB
R1705
4.7K/6
B MC_PWR_SW_OUT_N
IPMI_PWRBT_IN_N
3
3VSB
R1557 0/6/X
R1708 0/6
R1706 0/6
C782
C781
0.1U/6
0.1U/6
65
DIR#
STEP#
WDATA#
WGATE#
IRRX2_IRSEL0/GPIE6
IRTX/GPIO15
GPIO14/WDO#
PWBTIN#/GPIS2
SLPS3#
SLPS5#/AVI0
AVI1
38
R1903 4.7K/6
PWRBTN
R1845 0/6/X
C783
0.1U/6
TRK0#
WP# RDATA# HDSEL#
DSKCHG#
IRRX1/GPIE7
GPIO13/SDA GPIO12/SCL
GPIO11
VDD VSS
D2P D2N/TS3 D1P/TS2 D1N/TS1
VREF AVSS AVDD
AVI6 AVI5 AVI4 AVI3 AVI2
AVI1
PWRBTN ICH3_PWRBNIN_N
CASEOPEN CHASO
R1422 0/6
CLOSE_SCSI_TERM [29]
R1846 0/6
64 63 62 61 60 59 58 57 56
I2C_SIO3_DAT
55
I2C_SIO_CLK
54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39
2
C784
C785
0.1U/6
0.01U/6
DENSEL DRATE0 INDEX_N MTR0_N DR1_N DR0_N MTR1_N DIR_N STEP_N WDATA_N WGATE_N TRK0_N WP_N RDATA_N HDSEL_N DSKCHG_N
CIRRX
WDO#
R1764 0/6/X R1765 0/6/X
VCC3
D2P VTIN3 VTIN2 VTIN1
AVSS
C1299
0.47U/6
ICH3_PWRBNIN_N [38]
3VSB
ICH3_PWRBNIN_N
2
3VSB
C778
0.1U/6
DENSEL [29] DRATE0 [29] INDEX_N [29] MTR0_N [29] DR1_N [29] DR0_N [29] MTR1_N [29] DIR_N [29] STEP_N [29] WDATA_N [29] WGATE_N [29] TRK0_N [29] WP_N [29] RDATA_N [29] HDSEL_N [29] DSKCHG_N [29]
D2P [40] VTIN3 [40] VTIN2 [40] VTIN1 [40]
R1370 10/6
EC97
C1300
22U/16V/5*8
0.1U/6
R1372 0/6/X
ICH3_SLP_S5_N [38,49] ICH3_SLP_S3_N [38,46] PWRBTN [29,42] PSON_N [49]
SIO_PME_N [36] V_BAT [37,38]
ICH3_RI_N [38,42]
TP382
ICH3_THRM_N [37] SIO_CLK48 [46]
SIO_SMI_N [36]
1
VCC1_8
R1360
AVI6
C779
0.1U/6
AVSS
NEAR IO
VTIN2
C1640 2200P/6/X
VTIN1
VCC3
AVI6 AVI5 AVI4 AVI3 AVI2
Title
Size Document Number Rev
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
LPC SIO
10K/6
C1295
R1362
0.1U/6
680K/6
D2P
C1639 2200P/6/X
VTIN3
I2C_BUS0_DAT [5,7,35] I2C_BUS0_CLK [5,7,35]
GA-8IPP533
AVI2
AVSS
AVI1
AVSS
AVI3
AVSS
AVI4
AVSS
AVI5
AVSS
1
39 58Tuesday, October 21, 2003
C1296
0.1U/6
C1297
0.1U/6
C1298
0.1U/6
C1301
0.1U/6
C1302
0.1U/6
VCC
R1361
9.1K/6
R1363 10K/6
V_CORE
R1364 10K/6
R1365 330K/6
VTT_DDR
R1366 10K/6
R1368 330K/6
VCC2_5
R1371 10K/6
R1373 680K/6
+12V
R1374 36K/6
R1375 10K/6
1.3
3VSB
R1716 4.7K/612 R1717 4.7K/612 R1718 4.7K/612 R1719 4.7K/612 R1720 4.7K/612 R1721 4.7K/612
R1709 4.7K/6/X12
R1803 4.7K/612
D D
R1710 10M/612
ICH3_PS_ON_N[49] IPMI_PROC0_HOT_N[9] IPMI_PROC1_HOT_N[9]
IPMI_BEEP[42] KB_FUSE[42]
BMC_IDLED[41]
C C
B B
CPU0_THERM_DA1[5]
CPU0_THERM_DC1[5]
CPU1_THERM_DC1[7]
5
IPMI_BEEP BMC_IDLED BMC_I2CRST# CLEAR_CMOS I2C_UNLOCK HDD_FAIL
CASE_SW_PRSENT_N
THE CASE_OPEN1 PULL UP TO VBAT AT PCI RISER CARD.(R943 1M)
CASE_OPEN1
BMC_SMB_CLK[35,51]
BMC_SMB_DAT[35,51] ADM_INT_N[51]
CASE_OPEN1[28,39,49] D2P[39]
FAN_SENSE5[30] FAN_SENSE4[30] FAN_SENSE3[30] FAN_SENSE2[30] FAN_SENSE1[30]
BMC_SMB_CLK
BMC_SMB_DAT
ADM_INT_N
CASE_OPEN1
ICH3_PS_ON_N IPMI_PROC0_HOT_N IPMI_PROC1_HOT_N CASE_SW_PRSENT_N
IPMI_BEEP
KB_FUSE
BMC_IDLED
FAN_SENSE5 FAN_SENSE4 FAN_SENSE3 FAN_SENSE2 FAN_SENSE1
CPU0_THERM_DA1
CPU0_THERM_DC1 CPU1_THERM_DA1
CPU1_THERM_DC1
R1797 0/612 R1722 0/6/X12 R1747 0/6/X12
VCC3
12
12
R1780 47/612 R1781 47/612
R1873
4.7K/6/X
R1874
4.7K/6/X
C1596 2200P/6
C1597 2200P/6
ADD
R1754
4.7K/6
ADD
FAN3 FAN2
3VSB
12
13 14 17
15 16
47 48
1
2 12 11 10
9
6
5
4
3 26
25 28 27
ADM1026
4
I2C ADDRESS 5C
PIN 15: NC 0101 110XB
GND 0101 100XB
3.3V 0101 101XB
U153
SCL SDA INIT#
ADD/NTESTOUT CI
GPIO11 GPIO10 GPIO9 GPIO8 FAN7/GPIO7 FAN6/GPIO6 FAN5/GPIO5 FAN4/GPIO4 FAN3/GPIO3 FAN2/GPIO2 FAN1/GPIO1 FAN0/GPIO0
D1+ D1-/NTESTIN D2+/AIN8(0-2.5V) D2-/AIN9(0-2.5V)
AIN7(0-2.5V) AIN6(0-2.5V)
AIN5(0-3V) AIN4(0-3V) AIN3(0-3V) AIN2(0-3V) AIN1(0-3V) AIN0(0-3V)
VCCP(0-3V)
+12V(0-16V)
-12V(0-16V)
+5VIN(0-6.6V)
+VBAT(0-4.4V)
3.3V MAIN
3.3V STBY
GPIO15 GPIO14 GPIO13 GPIO12
GPIO16/THERM#
VREF RESET MAIN# RESET STBY#
AGND
DGND
PWM
DAC
34 35 36 37 38 39 40 41 33 32 31 30 29 7
22
43 44 45 46 18 23
42 24
20 19
21 8
3VSB
R1798 0/6/X12 R1799 0/6/X12 R1800 0/6/X12 R1801 0/612
VTT_DDR
VCC1_2
12
VCC1_5DUAL
C1595
0.1U/6
R1883 0/6/X12
VCC2_5G
VCC1_8
VCC2_5DUAL
1_8SB
VCC2_5
BMC_I2CRST# CLEAR_CMOS I2C_UNLOCK HDD_FAIL ADM_PWM1 ADM_DAC
ADM_IDSW_N
3
+12V VCC3
V_CORE
-12V
BMC_I2CRST# [35] CLEAR_CMOS [38] I2C_UNLOCK [35] HDD_FAIL [29] ADM_PWM1 [30] ADM_DAC [30]
ADM_IDSW_N [41]CPU1_THERM_DA1[7]
ACTIVE LOW OUTPUT.
BMC_RSMRST_N [49,51]
R1843 0/6/X
VCC
RTCVDD
VBAT_ADM
R1844 0/6
THE OD OUTPUT ADM_PWM1 PULL UP AT BLACKPLAN SIDE.
2
Temperature Sensing
VTIN1[39]
VTIN2[39]
VTIN3[39]
+12V
R1876 0/6/X
R1877 0/6/X
R1878 0/6/X
R1879 0/6/X
SYS_FAN2
3 2 1
FAN/X
1
NEAR CPU
CPU0_THERM_DC1
CPU0_THERM_DA1
CPU1_THERM_DC1
CPU1_THERM_DA1
I2C ADDRESS
A A
Title
Size Document Number Rev
5
4
3
2
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
ADM1026
GA-8IPP533
40 58Tuesday, October 21, 2003
1
1.3
8
VCC
U27
20 19 18 17 16 15 14 13 12
VCC ROUT1 ROUT2 ROUT3 DIN1 DIN2 ROUT4 DIN3 ROUT5
GD75232
DOUT1 DOUT2
DOUT3
GD75232
RIN1 RIN2 RIN3
RIN4 RIN5
DCD1
D D
C C
DSR1 RXD1 RTS1 TXD1 CTS1 DTR1 RI1
EMP & COM1 SWITCH
DCD1
DCD1[39]
DSR1
DSR1[39]
RXD1
RXD1[39]
RTS1
RTS1[39]
TXD1
TXD1[39]
CTS1
CTS1[39]
DTR1
DTR1[39]
RI1
RI1[39]
BMC_DCD1[51] BMC_DSR1[51] BMC_RXD1[51]
BMC_RTS1[51] BMC_TXD1[51] BMC_CTS1[51]
BMC_DTR1[51]
B B
BMC_RI1[51]
BMC_DCD1 BMC_DSR1 BMC_RXD1 BMC_RTS1 BMC_TXD1 BMC_CTS1 BMC_DTR1 BMC_RI1
RN255 8P4R-0
EMP
Rear side
C1598
0.1U/6
C1601
0.1U/6
RTS TXD DTR
A A
DCD DSR RXD CTS RI
8
12
14 15
16
20 21
26 22 19
24
R1713 10K/6/X
U154
7 6
8 5
ADM213
C1+
C1­C2+
C2-
T1 IN T2 IN T3 IN T4 IN
R1 OUT R2 OUT R3 OUT R4 OUT R5 OUT
EN
7
+12V
C788
0.1U/6
1
V+
DCD_H_N
2
DSR_H_N
3
RXD_H_N
4
RTS_H_N
5
TXD_H_N
6
CTS_H_N
7
DTR_H_N
8 9 1011
V-GND
RN252 8P4R-0/X
RN253 8P4R-0/X
C790
0.1U/6
12 34 56 78 12 34 56 78
RN254 8P4R-0
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
11
VCC
13
V+
17
V-
10
GND
2
T1 OUT
3
T2 OUT
1
T3 OUT
28
T4 OUT
9
R1 IN
4
R2 IN
27
R3 IN
23
R4 IN
18
R5 IN
25
SD#
-XRI1
-12V
DCD DSR RXD RTS TXD CTS DTR RI
DCD DSR RXD RTS TXD CTS DTR RI
ADM213_VCC
ADM213_SD-EMP_EN
VCC
7
1 2
5VSB
R1712 1K/6/X
CP5 470P
3 4
5 6
7 8
1 2
3 4
5 6
7 8
-XRI1 [42]
VCC
REV:0.5 ADD R1891,R1892
R1891
R1892
0/8
0/8/X
C1600
C1599
0.1U/6
0.1U/6
C1602
0.1U/6
DCD_D_N DSR_D_N RXD_D_N RTS_D_N TXD_D_N CTS_D_N DTR_D_N
-XRI1
5VSB
R1889 1K/6
REV:0.5 ADD R1889
6
COM_GND
CP6 470P
COM_GND
COM_GND
REV:0.5 ADD R1888
EMP_EN_N[51]
EMP_EN_N EMP_EN
R1655 0/6/X
CP1 470P
1 2
3 4
5 6
7 8
1 2
3 4
-XRI1 [42]
6
COM2
1 3 5 7 9
BOX HEADER2X5-1
FB61
1 2
FB62 FB80/81 2
5VSB
C1383
0.1U/6
VCC
R1888
4.7K/6/X
CP2 470P
5 6
7 8
1 6 2 7 3 8 4 9 10 5
COM/ATX
COM1
C1382
0.1U/6
2 4 6 8
FB80/8
5VSB
R1637
4.7K/6
11
5
COM2
DCD2[39] DSR2[39] RXD2[39]
RTS2[39] TXD2[39] CTS2[39]
DTR2[39] RI2[39]
LED_MSG_N[51]
ICH_SYSEVENT_N[37]
5
LED_MSG_N
ICH_SYSEVENT_N
3VSB
3VSB
3VSB
R1582
20K/6/X
C1394 1U/6/X
R1789
4.7K/6
R1802 0/6/X
4
DCD2 DSR2 RXD2 RTS2 TXD2 CTS2 DTR2 RI2
R1647
10K/6/X
REV:1.1 ADD U172
3VSB
53
U161
1 2
SN74AHC1G08/SOT23-5
4
VCC
U28
20
VCC
19
ROUT1
18
ROUT2
17
ROUT3
16
DIN1
15
DIN2
14
ROUT4
13
DIN3
12
ROUT5
GD75232
GD75232/X
I.D SWITCH
U141A
1
CLR D CLK PRE
SN74AHC74/X
Q185 2N7002
2
GND
VDD
3VSB
5VSB 5VSB
2 3 4
4
SYSEVENT LED
RIN1 RIN2
RIN3 DOUT1 DOUT2
RIN4 DOUT3
RIN5
3VSB
14 5
Q
6
Q
7
U172
53
NC7S14/SOT23-5/X
24
R1787
4.7K/6
3
1
3
V+
V-GND
3
C789
0.1U/6/X
1 2 3 4 5 6 7 8 9 1011
2
+12V
C791
0.1U/6/X
C1380
0.1U/6
3
1
-XRI2
5VSB
3
1
3VSB
R1788
4.7K/6
-12V
R1755
4.7K/6
Q175 2N7002
R1584
4.7K/6
Q186
2N7002
2
CP3 470P/X
1 2
3 4
5 6
7 8
-XRI2 [29,42]
2
SW1
3
4
5
6
1
2
LED_SW
Title
Size Document Number Rev
Date: Sheet of
CP4 470P/X
1 2
3 4
5 6
7 8
5VSB
3
1
5VSB
R1583
330/6
SYSEVENT_N
R1756
4.7K/6
Q176 2N7002
R1749 0/6
C1381 1U/6
LED1
KA4040
DCD2_B DSR2_B RXD2_B RTS2_B TXD2_B CTS2_B DTR2_B RI2_B
3VSB
R1757
4.7K/6
R1751 0/6
2
BMC_IDLED
ID_SW
21
ID_LED [29]
BMC_IDLED [40]
ID_SW [29,51]
5VSB
VCC
R1715 330/6
REV:1.2 ADD R1916
SYSEVENT_N [29]
DCD2_B [29] DSR2_B [29] RXD2_B [29] RTS2_B [29] TXD2_B [29] CTS2_B [29] DTR2_B [29] RI2_B [29,42]
ADM_IDSW_N
R1916
330/6/X
GIGA-BYTE TECHNOLOGY CO., LTD.
SERIAL PORT
GA-8IPP533
2
1
ADM_IDSW_N [40]
1.3
41 58Tuesday, October 21, 2003
1
8
PVCC
R541 33/6
D D
SPK-
R542 33/6
BC4
0.1U/6
1 2
Q25
MMBT2222A
D19 1N4148/S
3
1
7
3
2
Q86
MMBT2222A
2
1
R547 330/6
SPK-
R953
330/6/X
6
PVCC
INTERNAL SPEAKER
IPMI_BEEP [40]
ICH3_SPKR [38]
1 2 3
BZ1
+
-
-
BUZZER
5
4
ICH3_RI_N[38,39]
ICH3_RI_N
321
MMBT2222
321
MMBT2222
Q28
Q29
3
EC48 22U16V/D
R550 10K/6
R552 1K/6/X
R549 10K/6
R551 10K/6
R548
82K/6
1
5VSB
3
WOL H1X3
C803
0.1U/6
J19
1 2
MRN H1X2/X
2
D20
1N4148/S
D21
1N4148/S
J18
-XRI2
12
-XRI1
12
RING IN
2
LAN WAKE UP
MODEM WAKE UP
1
-XRI2 [29,41]
-XRI1 [41]
C797
0.1U/6
VCC
R1662 1K/6
KB_FUSE [40]
BC7
0.1U/6
KEYBOARD & MOUSE CONNECTOR
FUSEVCC
FB10 FB30/8
C C
JP13
1
H1X4/X
2 3 4
PWB-
C1044
0.1U/6 R949 100/6
PWB-[29] PWB+[29,39]
R950
PWRBTN[29,39]
B B
3
REV:0.5 ADD D69
10K/6
D69
BAT54A/SOT23
1 2
3VSB
IPMI_CPU0_THRMTRIP_N [9,48,51]
IPMI_CPU1_THRMTRIP_N [9,48,51]
RST_SW
RST_SW [29,48]
GN+
GN+ [29,36]
THE PIN FUNCTION IS GREEN BOTTOM.
GENERATE THE EVEN GN+ TO ICH3-S GPI12.
RESET SWITCH
KB_DATA[39]
KB_CLK[39]
MS_DATA[39]
MS_CLK[39]
KB_DATA
KB_CLK
MS_DATA
MS_CLK
FB11 75/6
FB12 75/6
C804 470P/6
FB13 75/6
FB14 75/6
C806 470P/6
VCCE
BC8
0.1U/6
KB_DT
KB_CK
C805 470P/6
MS_DT
MS_CK
C807 470P/6
GREEN LED ON WHEN SYSTEM UNDER S1 STATE
C798
0.1U/6
VCC FUSEVCC
BC5
0.1U/6
CN1
1
KBDAT
2
NC
3
KBGND
4
KBVCC
5
KBCLK
6
BC1
0.1U/6
7 8
9 10 11 12
FB9
FB30/8
NC
MSDAT NC MSGND MSVCC MSCLK NC
KB_CLK MS_CLK MS_DATA KB_DATA
C799 1U/8
VCCE
VCC
CN1
PVCC
BC6
0.1U/6
BC2
0.1U/6
FS3
2.5A_poly
Po lySwitch_2.5A DIP
G G G
G G
RN204
2 4 6 8
8P-4.7K
13 14 15
16 17
1 3 5 7
5VSBVCC
A A
Title
Size Document Number Rev
8
7
6
5
4
3
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
FRONT PANEL AND KB/MS
GA-8IPP533
2
42 58Tuesday, October 21, 2003
1
1.3
8
VCC3
ICH3_AD[0..31][29,35,36]
D D
ICH3_CBE0 _N[29,35,36] ICH3_CBE1 _N[29,35,36] ICH3_CBE2 _N[29,35,36] ICH3_CBE3 _N[29,35,36]
VGA_CLK3 3[46]
ICH3_PCIRST_N[29,35,36,37,39,48,51]
FB25
FB30/8
ICH3_PIRQC_N[35,36]
HAD1[44]
ICH3_FRAME_ N[29,35,36]
ICH3_IRDY_N[29,35,36] ICH3_TRDY_ N[29,35,36]
ICH3_DEVSEL_N[29,35,36]
ICH3_STOP_ N[29,35,36]
ICH3_PAR[29,35,36] ICH3_GNT0_N[36] ICH3_REQ0_N[36]
VCC3
8
C C
B B
A A
R613 0/6
R614 10K/6
CRTDAT[45] CRTCLK[45]
VCC3
R615 47K/6 R616 47K/6 R618 47K/6
VCC2_5G
VCC2_5G
ICH3_AD 0 ICH3_AD 1 ICH3_AD 2 ICH3_AD 3 ICH3_AD 4 ICH3_AD 5 ICH3_AD 6 ICH3_AD 7 ICH3_AD 8 ICH3_AD 9 ICH3_AD10 ICH3_AD11 ICH3_AD12 ICH3_AD13 ICH3_AD14 ICH3_AD15 ICH3_AD16 ICH3_AD17 ICH3_AD18 ICH3_AD19 ICH3_AD20 ICH3_AD21 ICH3_AD22 ICH3_AD23 ICH3_AD24 ICH3_AD25 ICH3_AD26 ICH3_AD27 ICH3_AD28 ICH3_AD29 ICH3_AD30 ICH3_AD31 ICH3_CBE0_N ICH3_CBE1_N ICH3_CBE2_N ICH3_CBE3_N VGA_CLK3 3 ICH3_PCIRST_N ICH3_PIRQC_N
ICH3_FRAME_ N
ICH3_IRDY_N
ICH3_TRDY_ N ICH3_DEVSEL_N ICH3_STOP_ N ICH3_PAR ICH3_GNT0_N ICH3_REQ0_N
IDSELVGA
CRTCLK
VCC3
C816
0.1U/6
V16
W16
V15 Y16
W15
Y15 V14
W14
Y14 V12 Y13
W12
Y12 V11 Y11
W11
V8 W8 W7
Y7
V7
Y6 W5
Y5 W3
Y3
V3
Y2 W2
Y1
V2 W1
V13
W10
Y8 W4
V1
U2 U3
U16
W9
Y9
V9
Y10 V10
U10
T2
U1
T1
T3
R2 N2 N3
P2
P3
P1
V5 W6
V6
R3
W13
Y4
R1 U4
V4
U5
U13
G1 G2 G3
F2
F1
F3
E3
E2
H2
J1
H3 H1 D1 C1 C2
B2
A2
C3
B3
A3
E1
R622 4.7K/6 R624 4.7K/6
R641 2K/6 R642 2K/6
FB20
FB30/8
FB24
FB30/8
7
C817
4.7U/12
T4U6U9
AD0 AD1
VDDQ
VDDQ
AD2 AD3 AD4 AD5 AD6 AD7 AD8 AD9 AD10 AD11 AD12 AD13 AD14 AD15 AD16 AD17 AD18 AD19 AD20 AD21 AD22 AD23 AD24 AD25 AD26 AD27 AD28 AD29 AD30 AD31 C/BE#0 C/BE#1 C/BE#2 C/BE#3 PCICLK RESET# INTR# M66EN/BIOSFFCLK/HAD1 FRAME# IRDY# TRDY# DEVSEL# STOP# PAR GNT# REQ#
ST0 ST1 ST2 SBA0 SBA1 SBA2 SBA3 SBA4 SBA5 SBA6 SBA7/IDSEL RBF# ADSTB0 ADSTB1 SBSTB AGPGPIO0/CLKRUN# AGPGPIO1/STP_AGP# AGPGPIO2 AGPGPIO3 SAD0/HCLK SAD1 SAD2 SAD3 SAD4/HAD4 SAD5/HAD5 SAD6/HAD6 SAD7/HAD7 DS/VIPCLK AS/HCNTL SRDY/INT/HAD0 BYTCLK Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 PCLK
LPVDD
C837
4.7U/12
TXVDDR
C843
4.7U/12
7
C818
0.1U/6
U14
VDDQ
VDDQ
C819
4.7U/12
M17
K17
VDDR1
VCC3
H17
VDDR1
D16
VDDR1
D10
VDDR1
C820 1U/8
VDDR1
C821
4.7U/12
6
D7D4G4
VDDR2
VDDR2
C822
0.1U/6
VDDR2
C823
0.1U/6
L17D8P4
VDDC
VDDC
U11
VDDC
VCC2_5G
VDDC
5
U12
VSS
VSS
ATI RAGE 128 VR
VSYNC
HSYNCBGRXTALOUT
RSET
AVDD
AVSS
AVSS
PVDD
LCDPE
LCDCLK
SDA/HAD2
SCL/HAD3/VIPINT
ZVHREF/LCD0
ZVVSYNC/LCD1
UV0/LCD2
UV1/LCD3
UV2/LCD4
UV3/LCD5
UV4/LCD6
UV5/LCD7
UV6/LCD8
UV7/LCD9
SDS/LCD10/SDA
SAS//LCD11/SCL
SSAD0/LCD12
SSAD1/LCD13
SSAD2/LCD14
SSAD3/LCD15
SSAD4/LCD16
SSAD5/LCD17
SSAD6/LCD18
SSAD7/LCD19
MONID0/LCD23
MONID1/LCD22
MONID2/LCD21
MONID3/LCD20
E4D2J3J2C9B9A9C8B8A8C7B7A7D6C6B6A6D5C5B5A5C4B4A4K1K2K3J4U8F4U15
R630
R629
C838 100P/6
C844 100P/6
R626 0/6
MONID1[45] MONID2[45]
R627 0/6
R628 0/6
VSYNC[45] HSYNC[45] BB[45] GG[45] RR[45]
R631
0/6
0/6
0/6
FB5175/6
MONID1
FB5275/6
MONID2 CLK0
VSYNC
HSYNC
C1384 10P/6
C1386 10P/6
6
AGPCLAMP
GIOCLAMP
VCC
VCC5VGA
R632 10K/6
75/6 75/6
C1385 10P/6
TESTEN
M4
PVSS
PVDD
R633
374/6/1
FB5375/6 FB5475/6 FB2175/6 FB22 FB23
L2N4K4L4L3
AAVDD
5
M3M2N1M1L1B1A1
4
J10
J11
J12K9K10
K11
K12L9L10
L11
L12M9M10
M11
M12
T17
J17
D15D9H4R4U7
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
XTALIN
CLK0
CLK0#
CLK1
CLK1#
VREF
P17
N20
N19
M20
M19
N17
R634
VCC3
0/6
R635
4.7K/6
Y4_P2
Y4
29.49MH Z
Y4_P1
R636
4.7K/6
R637 0/6
C842 22P/6
R649
4.7M/6
C845 22P/6
J9
U31
L18
VD0
MD0
L19
MD1
K18
MD2
K19
MD3
K20
MD4
J18
MD5
J19
MD6
J20
MD7
H18
MD8
H19
MD9
H20 G17 G18 G19 G20 F17 F18 F19 F20 E17 E18 E19 E20 D17 D18 D19 D20 C18 C19 C20 B20 A20 B19 A19 B18 A18 C17 B17 A17 C16 B16 A16 C15 B15 A15 D14 C14 B14 A14 D13 C13 B13 A13 D12 C12 B12 A12 D11 C11 B11 A11 C10 B10 A10 D3 Y18
MA0
Y19
MA1
Y20
MA2
W18
V3
MA3
W19
MA4
W20
MA5
V18
V6
MA6
V19
MA7
V8
V20
MA8
U18
MA9
U19 U20 P20 L20 R17
WE#
P19 P18 R20 R19 R18 T20 T19 T18
MCS- 0 [44] MCS- 2 [44] CKE [44]
R647 33/6
VD1 VD2 VD3 VD4 VD5 VD6 VD7 VD8 VD9 VD10 VD11 VD12 VD13 VD14 VD15 VD16 VD17 VD18 VD19 VD20 VD21 VD22 VD23 VD24 VD25 VD26 VD27 VD28 VD29 VD30 VD31
ROMCS-
V11
R617 33/6 R619 33/6 R620 33/6
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
DSF
M18
QS1
N18
QS0
R638 0/6/X
U17
CS1/BA1
CS2/QS2
CS3/QS3
Y17
V17
R639 0/6/X
4
W17
DSF [44]
VSS
ROMCS*
WE#0/DQM#0 WE#1/DQM#1 WE#2/DQM#2 WE#3/DQM#3 WE#4/DQM#4 WE#5/DQM#5 WE#6/DQM#6 WE#7/DQM#7
CS0/BA0
R623 0/6 R625 0/6 R640 0/6
VCC3
MD10 MD11 MD12 MD13 MD14 MD15 MD16 MD17 MD18 MD19 MD20 MD21 MD22 MD23 MD24 MD25 MD26 MD27 MD28 MD29 MD30 MD31 MD32 MD33 MD34 MD35 MD36 MD37 MD38 MD39 MD40 MD41 MD42 MD43 MD44 MD45 MD46 MD47 MD48 MD49 MD50 MD51 MD52 MD53 MD54 MD55 MD56 MD57 MD58 MD59 MD60 MD61 MD62 MD63
MA10 MA11 RAS# CAS#
ATI VGA
1 3 5 7
C841 10P/6/X
3
VD[0..31]
VD[0..31] [44]
2
VCC3 VCC2_5G
C824
0.1U/6/X
C825
0.1U/6/X
1
C827
C826
0.1U/6/X
0.1U/6/X
Locate on U31 Solder Side
EC50 100U/6.3*5
H1X3/YELLOW
VCC2_5G
FB17
FB30/8
JP8
C831
4.7U/12
VCC2_5GVCC2_5
21
C828 1U/8
1 2 3
Power Requirement : Rage XL :
VDDR=3.3V =>0.25A
VDDQ=3.3V =>0.15A VDDC=2.5V =>1.5A
PVDD-2.5V =>0.04A
AVDD=2.5V =>0.07A
ICH3_AD25
R612 100/6
IDSELVGA
JP8: 1-2: ENABLE
2-3: DISABLE
VCC2_5G VCC2_5G
C829
0.1U/6
EC98 100U/6.3*5
DEFAULT 1-2 SHORT
C830
0.1U/6
(PLACE CLOSE TO VGA CHIP)
VA[0..10]
VA2
1
2
3
4
V3
V6
V11 V8
VA3 VA1
5
6
7
8
VA0
1
2
VA7
3
4
VA6
5
6
VA5 VA4
7
8
1
2
VA9
3
4
VA10
5
6
7
8
VA8 MRAS- 0 MCAS- 0
2
DQM0 DQM1
4 6
DQM2
8
DQM3
RN208 8P4R-0
RN209 8P4R-0
RN210 8P4R-0
VA11 [44] VA8 [44] MRAS- 0 [44] MCAS- 0 [44]
-MWE [44]
RN211 8P4R-0
DQM[0..3]
VA[0..10] [44]
DQM[0..3] [44]
VCC2_5G
FB18
FB30/8
PVDD
C834
4.7U/12
C832
0.1U/6
VCC2_5G
12
FB19 FB30/8
AAVDDCRTDAT
C833
4.7U/12
C835
0.1U/6
(PLACE CLOE TO PIN L3)
VCC3
3
R644 150/6
R648 100/6
MCK [44]
EMI Solution
-MWE
C836 10P/6
MRAS-0
C839 10P/6
MCAS-0
C840 10P/6
GIGA-BYTE TECHNOLOGY CO., LTD.
Title
ATI RAGE XL
Size Document Number Rev
Date: Sheet of
2
ROMCS-
R645 4.7K/6
R645 Pull-Down for M/B Implementation
GA-8IPP533
43 58Tuesday, October 21, 2003
1
1.3
8
7
VCC3
6
5
4
3
2
1
C850 1U/8
C851
0.1U/6
VA[0..10] [43]
C847
4.7U/12
DQM0 DQM1 DQM2 DQM3
R662 0/6
CKE MCK
R664 2K/6
VCC3
C848 1U/8
1U/8
VA[0..10]
DQM0 [43] DQM1 [43] DQM2 [43] DQM3 [43]
MCS-0 [43] MRAS-0 [43] MCAS-0 [43]
-MWE [43]
CKE [43] MCK [43]
VCC3
C846
VSS
69
NC
NC
A10(AP)
A0CAS#
VSS
VSS
DQM0 DQM1 DQM2 DQM3
VSS
725844865238124663284
BA0 BA1
CS#
RAS#
WE#
MCH
CKE CLK
1U/8
U32
25
A0
26
A1
27
A2
60
A3
61
A4
62
A5
63
A6
64
A7
65
A8
66
A9
24
22 23
16 71 28 59
20 19 18 17
73
NC
70 30
NC
57
NC
21
NC
67 68
D D
VD[0..31][43]
C C
B B
VD[0..31]
VD0 VA0 VD1 VA1 VD2 VA2 VD3 VA3 VD4 VA4 VD5 VA5 VD6 VA6 VD7 VA7 VD8 VA8 VD9 VA9 VD10 VA10 VD11 VD12 VD13 BA0 VD14 BA1 VD15
VD16 VD17 VD18 MCS-0 VD19 MRAS-0 VD20 MCAS-0 VD21 -MWE VD22 VD23 VD24 VD25 VD26 VD27 VD28 VD29 VD30 VD31
15291433419358155497514
VCC
DQ0 DQ1 DQ2 DQ3 DQ4 DQ5 DQ6 DQ7 DQ8 DQ9 DQ10 DQ11 DQ12 DQ13 DQ14 DQ15
DQ16 DQ17 DQ18 DQ19 DQ20 DQ21 DQ22 DQ23 DQ24 DQ25 DQ26 DQ27 DQ28 DQ29 DQ30 DQ31
SDRAM_2M32
VCC
2 4 5 7 8
10 11 13 74 76 77 79 80 82 83 85
31 33 34 36 37 39 40 42 45 47 48 50 51 53 54 56
VCC
VCC
78
VCCQ
VSSQ
VSSQ
VCCQ
VCCQ
VSSQ
VSSQ
VCCQ
VSSQ
VCCQ
VCCQ
VSSQ
VSSQ
VCCQ
VCCQ
VSSQ
C849
C852
0.1U/6
C853
0.1U/6
FOR RAGE-XL
VA0
VA1
VA2
VA3
VA4
VA5
VA6
VA7
VA8
VA9
VA10
VA11[43]
HAD1[43]
1MX32X2 512KX32X4
VA11
HAD1
R650 10K/6
R651 10K/6/X
R652 10K/6/X
R653 10K/6/X
R654 10K/6/X
R655 10K/6/X
R656 10K/6
R657 10K/6/X
R658 10K/6/X
R659 10K/6/X
R660 10K/6/X
R661 10K/6/X
R663 10K/6
FOR RAGE 128 XL
VCC3
PCI 33MHz
AGP SKEW=DNI AGP SKEW=DNI 1X CLK SKEW=DNI 1X CLK SKEW=DNI ID ENABLE=DNI
PCI33-5V=1
VGA ENABLE=DNI INT ENABLE=DNI IDSEL IN AGP MODE AGP VCO GAIN=TBD AGP VCO GAIN=TBD
PCI BUS=1
MCS-2[43]
VA11[43]
MCS-2[43]
VA11[43]
DSF[43]
R665 0/6/X
VA11
R666 0/6
R667 33/6/X
VA11
R668 0/6/X
R669 0/6
BA0
BA1
A A
Title
Size Document Number Rev
8
7
6
5
4
3
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
FRAME BUFFER AND SDRAM
GA-8IPP533
2
44 58Tuesday, October 21, 2003
1
1.3
8
7
6
5
4
3
2
1
D D
R G B
GROUND REF PLANE
The analog DAC outputs R, G and B are designed to drive a 37.5 Ohm equivalent load.
C C
231
RR[43] GG[43]
B B
BB[43] MONID1[43]
CRTDAT[43] MONID2[43] CRTCLK[43]
HSYNC[43]
MONID1 CRTDAT MONID2 CRTCLK
231
Q48 BAT54S
R677 0/6 R678 0/6/X R679 0/6 R680 0/6/X
HSYNC
Q49 BAT54S
231
VCC5VGA
C857 0.1U/6
Q50 BAT54S
53
NC7SZ125/SOT23-5
42
U123
1
10mil/10mil/10mil
GUARD TRACE
Q51 BAT54S
C1632 22P/6/X
231
R1893
22/6
231
HH
GND GND GND GND
Q52 BAT54S
NEAR VGA CONNECTOR
Three resistor near VGA connector
R675
R674
75/6
75/6
H
V
C860
C859
22P/6
22P/6
R676 75/6
C861 22P/6
FB27
1 2
FB28 FB80/81 2 FB29 FB80/81 2
FB55 FB56 FB80/81 2
FB57 FB80/81 2 FB58
FB80/8
FB80/81 2
FB80/81 2
R672 10K/6
VCC5VGA
VCC5VGA
C854
0.1U/6
R673 10K/6
C862 10P/6
C863 10P/6
C855
0.1U/6
C864 10P/6
+12V
C856 1U/8
C865 100P/6
R670 0/6/X R671 0/6
Q47 78L05/92
3
IN
C866 100P/6
GND
2
C867 100P/6
OUT
1
C868 100P/6
R­G­B-
MS1 MS3 HS
VS
VCC
BC14
0.1U/6
EC51 22U16V/D
FB26
FB30/8
PolySwitch_1.5A
CN2
1
R
2
G
3
B
11
MS0
12
MS1
4
MS2
15
MS3
9
NC
13
HS
14
VS
5
VSS
6
VSS
7
VSS
8
VSS
10
VSSGG
VGA
FS4 1A_poly
VCC
C858
16
17
1U/6
VCC5VGA
VSYNC[43]
A A
8
VSYNC VV
7
REV:0.5 ADD R1893,R1894
NC7SZ125/SOT23-5
53
42
U124
C1633
1
22P/6/X
6
R1894
22/6
NEAR VGA CONNECTOR
Title
Size Document Number Rev
5
4
3
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
VGA CONNECTOR
GA-8IPP533
2
45 58Tuesday, October 21, 2003
1
1.3
5
4
3
2
1
VCC3
D D
FB31
FB30/8
C876 22U/12
VCC3
C869
0.1U/6
C877
0.1U/6
FB30
FB30/8
C878
0.1U/6
C870
4.7U/12
C879
0.1U/6
C871
0.1U/6
C880
0.1U/6
C872
0.1U/6
C881
0.1U/6
C882
0.1U/6
V3_CLK_A
C873
0.1U/6
CK40B_XTAL_IN
Y5
CK40B_XTAL_OUT
14.318MHz
C874 10P/6
C C
ICH3_CLK33[36]
C875 10P/6
R693 33/6
ICH3_CLK33_R
V3_CLK
IPMI_LPC33[51] VGA_CLK33[43] FWH_CLK33[37] SIO_CLK33[39]
80PORT_CLK33[48] PCISLOT4_CLK33[29] PCISLOT5_CLK33[35]
ICH3_CLK
ICH3_SLP_S3_N[38,39]
B B
ICH3_CLK66[38]
R1677 0/6/X
R1678 0/6
R696 33/6 R697 33/6 R698 33/6 R701 33/6 R700
R1283 33/6 R1411 33/6 R1412 33/6
R705 43.2/6/1
R1854 0/6/X
V18_PGOOD
R716 1K/6/X
ICH3_CLK
R1679 0/6
IPMI_LPC33_R VGA_CLK33_R FWH_CLK33_R SIO_CLK33_R
66BF_3V66_2
CK_408_VTT_PWRGD_N
V3_CLK
C883
0.1U/6
CPU0_BSEL0[5,48]
ICH3_CLK14[38]
U35
1
VDD
2
XTAL_IN
3
XTAL_OUT
4
VSS
5
PCIF0
6
PCIF1
7
PCIF2
8
VDD1
9
VSS1
10
PCI0
11
PCI1
12
PCI2
13
PCI3
14
VDD2
15
VSS2
16
PCI4
17
PCI5
18
PCI6
19
VDD3
20
VSS3
21
66BUFF0_3V66_2
22
66BUFF1_3V66_3
23
66BUFF1_3V66_4
24
66IN_3V66_5
25
PWRDWN_N
26
VDDA
27
VSSA
28 29
VTT_PWRGD_N SDATA
CK-408B
CK_408B
CY28329
REF0
S1
CPU3
CPU_3
CPU0
CPU_0
VDD6 CPU1
CPU_1
VSS4 VDD4 CPU2
CPU_2
MULT0
IREF
VSS_IREF
S2
USB_48MHZ
DOT_48MHZ
VDD_48MHZ VSS_48MHZ
3V66_1_VCH
PCI_STOP_N
3V66_0
VDD5 VSS5 SCLK
R681 22/6
56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30
V3_CLK
R685
R1828 0/6
10K/6
3
Q134 2N7002/X
2
1
R1676 0/6
R1530 0/6/X
ICH3_CLK14_R CK408B_S1 H_CLKINP_R H_CLKINN_R
V3_CLK
CK408B_MULT0 CK408B_IREF
CK408B_USB48M CK408B_DOT48M SIO_CLK48
MCH_CLK66_R P1_CLK66_R
I2C_BUS1_CLK_R I2C_BUS1_DAT_R
R719 10K/6
CPU0_BCLK0_R CPU0_BCLK1_R
CPU1_BCLK0_R CPU1_BCLK1_R
CK408B_CPU2 CK408B_CPU_2
R702 10K/6 R718 475/6/1
R703 33/6 R930 33/6
R707 43.2/6/1 R710 10K/6 R711 43.2/6/1
R715 0/6 R717 47/6
JP12
1 2 3
H1X3/X
R688 10K/6
V3_CLK
ICH3_CLK48
MCH_CLK66
V3_CLK
P1_CLK66
ICH3_SMBCLK ICH3_SMBDAT
V3_CLK
R691
R692
10K/6
10K/6
ICH3_CLK48 [38] SIO_CLK48 [39]
MCH_CLK66 [11] P1_CLK66 [24]
P64H2 CLK
ICH3_SMBCLK [11,15,16,19,20,24,37] ICH3_SMBDATA [11,15,16,19,20,24,37]
R1119 33/6/1 R1120 33/6/1
R686 33/6/1 R687 33/6/1
R694 33/6/1 R695 33/6/1
R704 33/6/1 R708 33/6/1
R689
49.9/6/1
R699
49.9/6/1
H_CLKINP H_CLKINN
R713
49.9/6/1
R682
49.9/6/1
CPU0_BCLK0 CPU0_BCLK1
R690
49.9/6/1
CPU1_BCLK0
CPU1_BCLK1
49.9/6/1
R714
49.9/6/1
H_CLKINP [11] H_CLKINN [11]
R683
49.9/6/1
CPU0_BCLK0 [5] CPU0_BCLK1 [5]
CPU1_BCLK0 [7] CPU1_BCLK1 [7]
ITP_BCLK0 [6] ITP_BCLK1 [6]
VCC3
VCC3
VCC3
R1852
VCC1_8
A A
PWROK_0[48]
R1853 1K/6
5
10K/6
CK_408_VTT_PWRGD_N
3
D
Q191 2N7002
G S
2
1
4
R1855
470/6
R1856 1K/6
3
2
Q193 2N3904
1
3
R1881 470/6
R1857 1K/6
2
V18_PGOOD
3
1
Q192
2N7002
C1651
0.1U/6/X
REV:0.4 ADD
2
Title
Size Document Number Rev
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
CLOCK GENERATOR
GA-8IPP533
46 58Tuesday, October 21, 2003
1
1.3
8
7
6
5
4
3
2
1
ICH3_USBP2N[37] ICH3_USBP2P[37]
D D
ICH3_USBP3N[37] ICH3_USBP3P[37]
ICH3_USBP2N ICH3_USBP2P
ICH3_USBP3N USBDT3­ICH3_USBP3P
FB32 FB220/8 FB34 FB220/8
FB36 FB220/8 FB38 FB220/8
C884
47P/6
C885 47P/6
C886 47P/6
USBDT2­USBDT2+
USBDT3+
C887 47P/6
ICH3_USBP0N[37] ICH3_USBP0P[37]
ICH3_USBP1N[37] ICH3_USBP1P[37]
IO SIDE
FS5 1A_poly
Front Side
R730 560K/6
R728
470K/6
ICH3_USB_OC2_N[37]
C894 1000P/6
USBDT2[30]
C C
USBDT2-[30] USBDT2+[30]
USBDT2­USBDT2+
C898
0.1U/6
USBPWR
C895 1U/8
EC52 220U/D
FB40 FB30/8
USBDT3+ USBDT3-
C899
0.1U/6
1U/6
C892
USB2
VCC_USB2
5VSB
VCC
JP9
1 2 3
H1X3/GREEN
JP9:USB WAKE UP
1-2:NORMAL 2-3:USB WAKE UP
VCC_USB2
PolySwitch_1.5A
USBDT3+ [30] USBDT3- [30] USBDT3 [30]
ICH3_USB_OC0_N[37]
USB1
I1
1
POSITION
ICH3_USBP0N ICH3_USBP0P
ICH3_USBP1N ICH3_USBP1P
C897 1000P/6
USBDT1­USBDT1+
Rear Side
R729
470K/6
R731 560K/6
C900
0.1U/6
VCC
VCC_USB1
5VSB
JP10
1 2 3
H1X3/GREEN
FB33 FB220/8 FB35 FB220/8
FB37 FB220/8 FB39 FB220/8
C888 47P/6
C896 1U/8
USB2
2 4 6 8
USB/ATX
JP10:USB WAKE UP
1-2:NORMAL 2-3:USB WAKE UP
EC53 220U/D
1 3 5 7 910 1112
C889 47P/6
IO SIDE
FB41 FB30/8
C890 47P/6
C893
1U/6
USBDT0­USBDT0+
C901
0.1U/6
C891 47P/6
USBDT0­USBDT0+
USBDT1­USBDT1+
FS6 1A_poly
VCC_USB1
PolySwitch_1.5A
B B
A A
Title
Size Document Number Rev
8
7
6
5
4
3
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
USB CONNECTOR
GA-8IPP533
2
47 58Tuesday, October 21, 2003
1
1.3
5
4
3
2
1
VCC3
BC50
0.1U/6
D D
4847464544434241403938
U128
I/O48
I/O47
I/O46
I/O45
I/O44
M4A3-32/32
I/O12
I/O13
I/O14
I/O15
VCC
1314151617181920212223
CPU0_VID2[5,49]
80PORT_CLK33[46]
CPU1_VID0[7,49] CPU1_VID1[7,49] CPU1_VID3[7,49] CPU0_VID0[5,49]
C C
TP386
80PORT_CLK33
CPU0_VID1[5,49]
ICH3_PCIRST_N[29,35,36,37,39,43,51]
CPU0_VID3[5,49] CPU1_VID4[7,49]
VID_LT VID_EQ_N
1
I/O5
2
I/O6
3
I/O7
4
TDI
5
CLK0/I0
6
NC
7
GND
8
TCK
9
I/O8
10
I/O9
11
I/O10
12
I/O11
VCC3
GND
I/O18
BC53
0.1U/6
NC
GND
VCC
I/O20
I/O40
I/O21
I/O39
I/O22
37
I/O38
I/O23
24
I/O37
I/O36 I/O35 I/O34 I/O33
CLK1/I1
I/O27 I/O26 I/O25
I/O24
TDO GND
TMS
36 35 34 33 32 31 30
NC
29 28 27 26 25
VID & CPU Occupied Detection
VCC3
U79A
14
1
VID_EQ_N
IPMI_CPU0_THRMTRIP_N[9,42,51]
IPMI_CPU1_THRMTRIP_N[9,42,51]
2
R1829 10K/6/X
CPU1_SKTOCC_N[7,51]
VID_GT
CPU1_BSEL1 [7] CPU1_BSEL0 [7] CPU0_BSEL1 [5] CPU0_BSEL0 [5,46] CPU0_VID4 [5,49]
TP387
CPU1_VID2 [7,49]
IF INSTALL TWO CPU,VID_EQ_N IS LOW, OTHERWISE IS HIGH
3
7
74LVC00/SO
LOW ACTIVE L OW : NORMAL OPERATION
R1325
10K/6
74LVC00/SO
4 5
D53
BAT54/SOT23 D54
BAT54/SOT23
2
VCC3
VCC
R1323 10K/6
3
Q129 2N2222
1
BC51
0.1U/6
14
U79B
6
7
23
23
R1324 10K/6
3
2
Q130 2N2222
1
9
10
R1115
10K/6
THERMAL_TRIP_N [50]
CONFIG_ERR_N
VCC3
14
7
VCC3
CPU0_SKTOCC_N[5,51] CPU1_SKTOCC_N[7,51]
DP_MODE_5V [50]
U79C
8
74LVC00/SO
VCC3
53
2 4
VCC3
53
2 4
PS_PWRGD[49]
U166
NC7S14/SOT23-5
U159
NC7S14/SOT23-5
12 13
VCC3
53
1 2
CONFIG_ERR
VCC3
14
7
U164 SN74AHC1G08/SOT23-5
4
U79D
11
74LVC00/SO
VCC3
1 2
R872
1K/6
U165 NC7SZ32/SOT23-5
53
4
2
C PU_CONFIG_ERR
3
Q83 2N7002
NORMAL Q83 IS
1
OFF,AND VRM WORK WELL
ABNORMAL WILL TURN ON Q83,AND VRM WILL TURN OFF
C PU_CONFIG_ERR [51]
VRM_OUTEN [50]
PWROK Generation
OD INPUT
B B
FROM BMC
A A
IPMI_RST_N[51]
RST_SW[29,42]
DRB_RESET_N[6]
ICH3_VRMPWRGD[38,50]
PS_PWRGD[49] BMC_PWROK_IN [51]
PGOOD_1D2[52,53]
PGOOD_1D25[54]
PGOOD_2D5[52]
R1753 0/6
R874 100/6
R1291 100/6/X
5
D67 BAT54/SOT23
D34 BAT54/SOT23
R1090 1K/6/X D66 BAT54/SOT23
R1159 0/6
R1161 0/6
23
23
23
PWROK_0
C933 1U/6
3VSB
R873
4.7K/6
4
C1604 1U/6
3VSB
147
U77B
3 4
74LVC14/SO
3VSB
BC52
0.1U/6
R1752
4.7K/6
PWROK_0 [46]
3VSB
147
U77A
1 2
74LVC14/SO
9 8
3VSB
147
U77D
74LVC14/SO
1 2
BMC_PWROK_IN
3
3VSB
53
U158
4
R1158 0/6
NC7SZ32/SOT23-5
3VSB
147
5 6
74LVC14/SO
3VSB
147
U77E
11 10
74LVC14/SO
U77C
2
R1089 0/6
R1117 10K/6/X
P64H2_PWROK
R1118 10K/6/X
IPMI_RST_IN_N [51]
ICH3_PWROK [11,31,38]
P64H2_PWROK [24]
Title
Size Document Number Rev
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
CPU VID CHECK AND POWER OK
GA-8IPP533
48 58Tuesday, October 21, 2003
1
1.3
5
VCC3
D D
VRM_VID4 VRM_VID3 VRM_VID2 VRM_VID1
VRM_VID0
C C
C1475 10U/12
C1479 10U/12
B B
R886 10K/6
R887 10K/6
R944 0/6
C1361
0.1U/6
C1358
0.1U/6
C1365
0.1U/6
RN223
8P4R-10K
RN224
8P4R-10K
RN226
8P4R-0
C1362
0.1U/6
C1476 10U/12
C1480 10U/12
C1359
0.1U/6
C1366
0.1U/6
12 34 56 78
12 34 56 78
12 34 56 78
CPU1_VID4 CPU1_VID3 CPU1_VID2 CPU1_VID1
CPU1_VID0
VRM_VID4 VRM_VID3 VRM_VID2 VRM_VID1
VRM_VID0
CPU0_VID4 CPU0_VID3 CPU0_VID2 CPU0_VID1
C1312
0.1U/6
+12V
C1477 10U/12
VCC
C1481 1U/6
C1360
0.1U/6
C1367
0.1U/6
VCC
C1313
0.1U/6
C1478 22U/12
C1310
0.1U/6
C1315
0.1U/6
CPU1_VID4 [7,48] CPU1_VID3 [7,48] CPU1_VID2 [7,48] CPU1_VID1 [7,48]
CPU1_VID0 [7,48]
VRM_VID4 [50] VRM_VID3 [50] VRM_VID2 [50] VRM_VID1 [50]
VRM_VID0 [50]
CPU0_VID4 [5,48] CPU0_VID3 [5,48] CPU0_VID2 [5,48] CPU0_VID1 [5,48]
CPU0_VID0 [5,48]
5VSB
C1363
0.1U/6
+12V
C1311
0.1U/6
VCC3
C1316
0.1U/6
ICH3_SLP_S5_N[38,39]
PS ON HI
BMC POWER ON ENABLE LOW ACTIVE
-12V
C1364
0.1U/6
REV:0.4 ADD
3VSB
SC414 100U/1210
EN_PSON_N[51]
VDD_ID[15,16,19,20]
SC415 100U/1210
4
3VSB
R1321 1K/6
53
U127
1 2
SN74AHC1G08/SOT23-5
R1322 0/6/X
EN_PSON_N
R1587
4.7K/6
REV:0.5 CHANGE TO 4.7K
-12V
PSON_N[39]
TO ADM1026 POWER ON DETECT.
ICH3_PS_ON_N[40]
R1106
4
+12V
VCC
VCC3
PSON
R1432
0/6/X
ICH3_PS_ON_N
1K/6
3
5VSB
R1792 1K/6
1
3
2
Q110 MMBT2222A
1
CASE_OPEN1[28,39,40] I2C_BUS1_DAT[29,35]
J9
A1
1
A2
2
A3
3
A4
4
A5
5
A7
7
A8
8
A9
9
A10
10
A11
11
A12
12
A13
13
A14
14
A15
15
A16
16
A17
17
A18
18
A19
19
A20
20
A21
21
A22
22
A24
24
A25
25
A26
26
A27
27
Power Connector/K-A6,K-A23
2
B1
28
B2
29
B3
30
B4
31
B5
32
B6
33
B7
34
B8
35
B9
36
B10
37
B11
38
B12
39
B13
40
B14
41
B15
42
B16
43
B17
44
B18
45
B19
46
B20
47
B21
48
B22
49
B23
50
B24
51
B25
52
B26
53
B27
52
5VSB
53
R1793
0/6/X
U144
NC7SZ32/SOT23-5
1
4
2
+12V
VCC
5VSB
C1133
0.1U/6
53
NC7SZ32/SOT23-5
VCC3
5VSB
U162
4
C1129
0.1U/6
I2C_BUS1_CLK[29,35]
5VSB
C1636
22U/12
PS_PWRGD [48]
2
5VSB
R1103 470K/6
C1637
22U/12
R1030
4.7K/6
5VSB
PSON
5VSB
R1031
4.7K/6 R1782 47/6
R1783 47/6
R1784 47/6
R1785 47/6
I2C_BUS1_ALERT#[35]
5VSB
R1381 0/6/X
U93
1
SDA
2
SCL
5
A2
6
A1
7 4
A0 GND
LM75/X
U94
1
SDA
2
SCL
5
A2
6
A1
7 4
A0 GND
LM75
U96
1
SDA
2
SCL
5
A2
6
A1
7 4
A0 GND
LM75/X
U97
1
SDA
2
SCL
5
A2
6
A1
7 4
A0 GND
LM75
1
5VSB
R1748 1K/6/X
3
TOUT
CPU1 TEMPERATURE SENSOR
8
VDD
3
TOUT
DRAM TEMPERATURE SENSOR
8
VDD
3
TOUT
CPU0 TEMPERATURE SENSOR
8
VDD
3
TOUT
SCSI TEMPERATURE SENSOR
8
VDD
5VSB
I2C ADDRESS 90
I2C ADDRESS 92
I2C ADDRESS 94
I2C ADDRESS 96
NEAR Q59.2
A A
EC68 220U/D
5VSB
C1635 22U/12
C1634
100U/1210
Q59
1084/252
3VSB
2
1
3
C925
0.1U/6
5
R860 100/6/0.5
R863 165/6/0.5
C921
0.1U/6
C926
0.1U/6/X
C922
0.1U/6
3VSB
3VSB
C923 1U/6
EC109 100U/6.3*5
U120
RST#VCC
GND
MIC809/SOT23
2
R857 22K/6/1/X
C1136 1U/6/X
Tune on EVT M/B
Standby Supply Monitor
4
13
R1714 0/6/X
BMC_RSMRST_N [40,51]
ICH3_RSMRST_N [38]
3
3VSB
1 2 3 4 5 6 7 8
8P4R-100
C907
0.1U/6
RN228
R852 15K/6/1
R855
33.2K/6/1
2
13
Q57
SC431L/SOT23
1_8SB
C913
C912
0.1U/6
1U/6
Title
Size Document Number Rev
2
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
POWER CONNECTOR
GA-8IPP533
49 58Tuesday, October 21, 2003
1
1.3
+12V
5
L10
0.6UH
+
C1149
0.01U/6
C1150
0.01U/6
C1151
0.01U/6
+
330U/16V
D D
C967
C968
330U/16V
+
C969
330U/16V
4
VIN
+
C970
330U/16V
VCC3
3
+12V
C971 1U/6
R896 10/6
C975 1U/6
2 7
3
U82
BOOT PVCC
PWM
HIP6601A
UGATE
PHASEVCC
LGATEGND
1 86 54
HUF76143S3S
Q76
2
VIN
C972
1U/6
MOSFET MUST USE 75A
Q75 HUF76137S3S1
3 2
L11
0.6UH
R899
1
3.9K/6
C974
1000P/6
1
V_CORE
VCORE 1.1V~1.85V/150A
3 2
R898 0/6/X
U170
VCC
ICH3_VRMPWRGD[38,48]
THERMAL_TRIP_N[48]
4 1
Y OEAGND
VCC3
5 2 3
NC7SZ126
REV:0.4 ADD U170
C C
DP_MODE_5V[48]
B B
VCC
R1309 340K/6/1
VCC
3
Q127 BSS138
2
1
R901
392K/6/1/X
R904 2K/6/X
2
R900
15K/6 C978
2200P/6
R1310
1.96K/6/1
1
Q128 BSS138
V_CORE
C979 120P/6
R905
2.2K/6/1
VRM_OUTEN[48]
VRM_VID4[49] VRM_VID3[49] VRM_VID2[49] VRM_VID1[49] VRM_VID0[49]
VRM_OUTEN
VRM_VID4 VRM_VID3 VRM_VID2 VRM_VID1 VRM_VID0
R902 150K/6
C980
0.1U/6/X
U83 HIP6301
1
VID4
2
VID3
3
VID2
4
VID1
5
VID0
6
COMP
7
FB
8
FS/DIS
9
GND
10
VSEN
R897 10K/6
HIP6301_PGOOD
VCC
C973
4.7U/12 C982
20
VCC
19
PGOOD
15
PWM1
14
PWM2
11
PWM3
18
PWM4
16
ISEN1
13
ISEN2
12
ISEN3
17
ISEN4
C1011
+12V
VIN
C976 1U/6
R903 10/6
1U/6
+12V
2 7
3
U84
BOOT PVCC
PWM
HIP6601A
UGATE
PHASEVCC
LGATEGND
1 86 54
HUF76143S3S
1
Q78
VIN
C998 1U/6
R908 10/6
1U/6R907 0/6 R909
2 7
3
U85
BOOT PVCC
PWM
HIP6601A
UGATE
PHASEVCC
LGATEGND
1 86 54
HUF76143S3S
1
Q80
3
V_CORE
+12V
VIN
C977
1U/6
Q77 HUF76137S3S1
3 2
L12
0.6UH
R906
C981
3.9K/6
1000P/6
3 2
C999
1U/6
Q79 HUF76137S3S1
3 2
L13
0.6UH
C1010
3.9K/6
1000P/6
3 2
C1023
1U/6
C1012 1U/6
R910 10/6
C1025
1U/6
A A
2 7
3
U86
BOOT PVCC
PWM
HIP6601A
UGATE
PHASEVCC
LGATEGND
1 86 54
HUF76143S3S
1
Q82
Q81 HUF76137S3S1
3 2
L14
0.6UH
C1024
R912
3.9K/6
1000P/6
R911 0/6
3 2
R913 0//6/X
Title
Size Document Number Rev
5
4
3
2
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
CPU VOLTAGE REGULATORS
GA-8IPP533
50 58Tuesday, October 21, 2003
1
1.3
5
RTCVDD
REV:0.4 ADD
SC412 100U/1210
EMP PORT ENABLE
D D
C C
B B
A A
BMC SMI OUTPUT ASF SMBUS DATA ASF SMBUS ALERT POWER OK HI : DISABLE CPU0 ADM10126 INT (TO BMC)
LPC FRAME LPC LAD3
LPC LAD0 LPC PCI RESET SERIAL IRQ RESET TO BMC RESET FROM BMC PCI PME BMC RSMRST IN BMC SCI OUTPUT TO RESET BMC FROM ICH3
POWER ON ENABLE IPMB SMBUS DATA IPMB SMBUS CLK BMC IDENTIFY SWITCH INPUT LOW ACTIVE
CPU0 PRESENT CPU1 PRESENT
BMC POWER ON DELAY LED
SC413 100U/1210
SMB_MUX_SW
ASF_SMBALERT_N[35,37]
ASF_SMBCLK[35,37]
ASF_SMBDAT[35,37]
ASF_SMBALERT_N
ASF_SMBCLK
ASF_SMBDAT
REV:0.4 ADD
RTCVDD
EMP_EN_N[41] BMC_TXD1[41] BMC_DCD1[41] BMC_SMI_N[37] ASF_SMBDAT[35,37]
BMC_PWROK_IN[48] CPU0_BOOT_N[9] ADM_INT_N[40]
ICH3_LDRQ1_N[37]
ICH3_LFRAME_N[37,39] ICH3_LAD3[37,39]
ICH3_LAD0[37,39] ICH3_PCIRST_N[29,35,36,37,39,43,48] ICH3_SERIRQ[36,39] IPMI_RST_IN_N[48]
IPMI_RST_N[48] ICH3_PME_N[27,28,31,35,36] BMC_RSMRST_N[40,49] BMC_SCI_N[37] RST_IPMI#[37]
EN_PSON_N[49] BMC_SMB_DAT[35,40] BMC_SMB_CLK[35,40]
ID_SW[29,41]
SMB_MUX_SW[35]
CPU0_SKTOCC_N[5,48] CPU1_SKTOCC_N[7,48] BMC_PWM1[30] BMC_PWR_LED_N[29] BMC_PWM2[30]
R1880 0/6
12
EMP_EN_N BMC_TXD1 BMC_DCD1 BMC_SMI_N ASF_SMBDAT
BMC_PWROK_IN CPU0_BOOT_N ADM_INT_N ICH3_LDRQ1_N
ICH3_LFRAME_N ICH3_LAD3
ICH3_LAD0 ICH3_PCIRST_N ICH3_SERIRQ IPMI_RST_IN_N IPMI_RST_N ICH3_PME_N BMC_RSMRST_N BMC_SCI_N RST_IPMI#
EN_PSON_N BMC_SMB_DAT BMC_SMB_CLK
SMB_MUX_SW
CPU0_SKTOCC_N
CPU1_SKTOCC_N
BMC_PWM1 BMC_PWR_LED_N
BMC_PWM2
5VSB
R1759 10K/6
1 2
2
Q180 2N7002/X
3
4
3
2
1
RSB AUX POWER CONNECTOR
IPMI Interface
VCC3
1 3 5 7
9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 61 63 65 67 68 69 70
HEADER 35X2 _2.54X1.27mm/FEMALE-PIN10-PIN11
1
2
Q181 2N7002/X
3
1
2
Q182 2N7002/X
3
1
3VSB
5VSB
VCC
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66
I2C_LAN_ALERT_N
I2C_LAN_CLK
I2C_LAN_DAT
BMC_RXD1 BMC_RI1
I2C_LAN_DAT I2C_LAN_CLK I2C_LAN_ALERT_N B IOS_RECOVERY_N
IPMI_LPC33 ICH3_LAD2
ICH3_LAD1 BMC_NMI_OUT
BMC_NMI_IN IPMI_PWRBT_IN_N BMC_PWR_SW_OUT_N
BMC_FORCEPR0_N IPMI_CPU0_THRMTRIP_N
IPMI_CPU1_THRMTRIP_N RESET_CPU_HOT_N
C PU_CONFIG_ERR BMC_FORCEPR1_N IPMI_IERR0_N IPMI_IERR1_N LED_MSG_N BMC_DSR1 BMC_RTS1 BMC_CTS1 BMC_DTR1
VCC3 3VSB5VSB VCC
BC61
BC60 1U/6
BMC_RXD1 [41] BMC_RI1 [41]
I2C_LAN_DAT [32] I2C_LAN_CLK [32] I2C_LAN_ALERT_N [32]
B IOS_RECOVERY_N [37]
IPMI_LPC33 [46] ICH3_LAD2 [37,39]
ICH3_LAD1 [37,39]
BMC_NMI_OUT [36] BMC_NMI_IN [36] IPMI_PWRBT_IN_N [39]
B MC_PWR_SW_OUT_N [39] BMC_FORCEPR0_N [9]
IPMI_CPU0_THRMTRIP_N [9,42,48] IPMI_CPU1_THRMTRIP_N [9,42,48]
RESET_CPU_HOT_N [9]
C PU_CONFIG_ERR [48]
BMC_FORCEPR1_N [9] IPMI_IERR0_N [9] IPMI_IERR1_N [9] LED_MSG_N [41] BMC_DSR1 [41] BMC_RTS1 [41] BMC_CTS1 [41] BMC_DTR1 [41]
BC62
1U/6GSMI1
1U/6
BMC_RESET_OUT_N
1.EMP_EN_N
3.BMC_TXD1_N
7.BMC_SMI_N
9.ASF_SMBDATA
11.ASF_SMBALERT
13.BMC_PWROK_IN
15.CPU0_BOOT_N
17.ADM_INIT_N
19.ICH3_LDRQ0_N
23.ICH3_LFRAME_N
25.ICH3_LAD3
31.ICH3_PCIRST_N
33.ICH3_SERIRQ
35.IPMI_RSTBT_N IN
35.IPMI_RST_N
39.ICH3_PME_N
41.BMC_RSMRST_N
43.BMC_SCI_N
51.EN_PSON_N
57.BMC_IDSW_N
61.CPU0_SKTOCC_N 63_CPU1_SKTOCC_N
65.BMC_PWM1
67.BMC_PWR_LED_N
69.BMC_PWM2 OUT
RTCVDD
BC64
BC58
1U/6 C1603
1U/6
ASF SMBUS CLK BMC TO LAN I2C DATA BMC TO LAN I2C CLK BMC TO LAN I2C ALERT BIOS PROTEC
BMC LPC CLOCK LPC LAD2
LPC LAD1 NMI SWITCH OUT (FROM BMC)
NMI SWITCH IN (TO BMC) POWER BUTTON IN (FROM ICH3 TO BMC) POWER BUTTON OUT (FROM BMCTO SIO)
CPU0 THERTRIP­CPU1 THERTRIP-
R1885 4.7K/6
CPU CONFIGURATION ERROR CPU0 IERR SIGNAL
CPU1 IERR SIGNAL. SYSTEM EVENT
ACTIVE LOW
OUT
10U/12
3VSB
12
OD OD5.BMC_DCD1_N OD OD
5VSB
1 2
AMP 171825-2
4.BMC_RXD1_N
6.BMC_RI1_N
10.ASF_SMBCLK
12.I2C_LAN_DAT
14.I2C_LAN_CLK
JP14
P G
H1X2
16.I2C_LAN_ALERT_N
HI ACTIVE IN
IN
LOW ACTIVE OUT
OUT
LOW ACTIVE IN
IN OD OD OD OD OD
LOW ACTIVE IN HI ACTIVE OUT
OD
LOW ACTIVE IN OD, LOW ACTIVE IN/OUT OD
LOW ACTIVE OUT
LOW ACTIVE IN
IN OD
LOW ACTIVE OUT OUT
LOW ACTIVE OUT IN
LOW ACTIVE IN
LOW ACTIVE IN
IN
LOW ACTIVE IN
IN OD OUT OUT
LOW ACTIVE OUT
18.BIOS_RECOVERY_N
26.ICH3_LAD2
28.ICH3_LAD1
32.BMC_NMI_OUT
34.NMI_SW_IN
36.IPMI_PWRBT_IN_N
38.BMC_PWR_SW_OUT_N
40.BMC_FORCEPR0_N
44.IPMI_CPU0_THRMTRIP_N
46.IPMI_CPU1_THRMTRIP_N
48.RESET_CPU_HOT_N LOW ACTIVE OUTOD
52.BMC_RESET_OUT_N OD LOW ACTIVE I/O(NOT USE)
56.BMC_FORCEPR1_N
58.IPMI_IERR0_N
60.IPMI_IERR1_N
62.LED_MSG_N
64.BMC_DSR1_N
66.BMC_RTS1_N
68.BMC_CTS1_N
70.BMC_DTR1_N
REV:0.5 JP14 MOVE TO CLOSE U32
OD OD OD OD OD IN
LOW ACTIVE IN
OD
LOW ACTIVE OUT OD OD
HI ACTIVE OUT
OD
HI ACTIVE IN
IN
LOW ACTIVE IN
IN
LOW ACTIVE OUT
OD29.ICH3_LAD0
LOW ACTIVE IN
IN IN
LOW ACTIVE IN
IN
HI ACTIVE IN54.CPU_CONFIG_ERR
IN
LOW ACTIVE IN
LOW ACTIVE IN
IN
LOW ACTIVE OUT
OUT
OD OD OD
Title
Size Document Number Rev
5
4
3
2
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
IPMI CONNECTOR
GA-8IPP533
51 58Tuesday, October 21, 2003
1
1.3
5
R1226
1.2V must be ready before 2.5V
D D
PGOOD_1D2[48,53]
R1228
2.7K/6
C1233 0.1U/6 C1234 0.01U/6
1M/6
D51
23
BAT54/SOT23
R1229
10K/6
C1225
1000P/6
1 2 3
R1233
R1234 15K/6 U115
51K/6
C1238 120P/6
C1240
C C
1200P/6
R1235
15K/6
C1242 470P/6/X
0/6/X
R1236
4 5
C12371000P/6
6
C12601000P/6
7 8
9 10 11 12 13
C1247
1000P/6
R1237
16K/6/1
2D5_VID0 2D5_VID1
B B
14 15 16 17 18 19
4
C1226 0.1U/6
1709_INTVCC
U70
RUN/SS SENSE1+ SENSE1­EAIN
TG1 SW1
BOOST1 PLLFLTR PLLIN FCB Ith SGND V_DIFFOUT Vos­Vos+ SENSE2­SENSE2+ ATTENOUT ATTENIN VID0
BG1
EXTVcc
INTVcc
PGND
BG2
BOOST2
SW2 TG2
PGOOD
V_BIAS
VID4 VID3
VID1 VID2
LTC1709-7
3VSB
2D5_VID2 2D5_VID3 2D5_VID4
R1242 100K/6/X
3
2
1
VCC
R1227 10/6
C1227 1U/6
R1230 10/6
3
1.0UH/20A
D31
MBRS130T3
3
1 2
R1232
L8
0.003/25
R1231 10/6
C1236 1U/6
C1228 10U/12
C1229 10U/12
C1230 10U/12
C1231 10U/12
EC88
680U/6.3V
EC89
680U/6.3V
MAX CURRENT 27A
VCC2_5
EC60
EC57
EC56 C1246 1U/6
3
1.0UH/20A
D32
MBRS130T3
1 2
3
L17
R1241
0.003/25
R1243 10/6
R1244 10/6
820U/4V
C1249 1U/6
820U/4V
820U/4V
C1244 1U/6
R1239
10/6
C1245
0.1U/6
R1240 10/6
U112
FDS7760A
4
U114
FDS7760A
4
67825
3
1
67825
3
1
U113
FDS7760A
4
FDS7760A
4
67825
1
67825
1
3
D52
1 2
BAT54A/SOT23
C1232
36
NC
35 34 33 32
VIN
31 30 29 28
1U/6
SW1
C1235 0.47U/6
C1239 1U/6 C1241 2.2U/6
PGND
27 26
C1243 0.47U/6
25 24 23 22 21 20
1709_INTVCC
R1238
10/6
C1248
0.1U/6
U116
FDS7760A
4
U118
FDS7760A
4
67825
3
1
67825
3
1
U117
FDS7760A
4
U119
FDS7760A
4
67825
1
67825
1
PGOOD_2D5[48]
REF_TRACK
REF_TRACK [54]
VCC
VCC2_5
R1245
R1246
R1247
R1248
0/6/X
0/6/X
0/6/X
A A
R1252
R1253
0/6
5
R1254
0/6
0/6
0/6/X
R1255 0/6
4
R1249 0/6/X
R1256 0/6
2D5_VID4 2D5_VID3 2D5_VID2 2D5_VID1 2D5_VID0
R1250 10K/6/1
R1251 10K/6/1
3
VCC
C1250
0.1U/6
84
U111B
5
+
7
6
-
LM2904
VREF_DDR_DIMM [12,15,16,19,20] VREF_DDR_MCH [12,15,16,19,20]
2
Title
Size Document Number Rev
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
2.5V VOLTAGE REGULATOR GA-8IPP533
52 58Tuesday, October 21, 2003
1
1.3
5
D D
4
3
2
1
U105 FDS7760A
4
C1191
0.1U/6
VCC
C908 0.1U/6
67825
FDS7760A4
3
1
67825
3
1
C1176
1U/6 C1179
U72
REV:0.5 L15 CHANGE TO HORIZONTAL
D47
MBRS130T3
1 2
C1177
10U/12
R1204 4/6/X
C1192 100P/6/X
C1178
10U/12
L15
1.0UH/20A
EC75
680U/6.3V
R1202
0.010/25
C1187
1000P/6
EC76
680U/6.3V/X
0.1U/6
R1206 402/6/1
R1207 806/6/1
C1180
0.1U/6
VCC1_2
680U/6.3V
EC78
MAXIMUM CURRENT
4.5A
C1188 1U/6
3VSB
R1200 100K/6
PGOOD_1D2[48,52]
OPERATION FREQUENCY 277KHZ
C C
C1181 47P/6 C1182 0.1U/6 C1184 330P/6
C1185
R1203
100P/6
33K/6
C1186
100P/6
R1199 1M/6/X
U73
1
Cosc
2
RUN/SS
3
ITH
4
PGOOD
5
SENSE-
6
SENSE+
7
Vo_SENSE
8
SGND
LTC1735CGN-1
TG
BOOST
SW VIN
INTVcc
BG
PGND
EXTVcc
R1201
10/6
D46
2 3
C1189 1U/6
BAT54/SOT23
C1190
4.7U/12
C1183 0.22U/6
16 15 14 13 12 11 10 9
REV:0.5 DELETE EC77
VCC1_8
B B
C1195
10U/12
MAX CURRENT: P64H2 2.66A,ICH3 0.55A,OTHERS
0.3A,TOTAL 3.5A
VCC3
1084/263
EC80
C1197
680U/6.3V
0.1U/6
Q163
VCC1_8
24
R1680 165/6/0.5
1
3
C1584
R1681
0.1U/6
78.7/6/1
C1585
0.1U/6/X
680U/6.3V
EC81
C1204
1U/6
VCC3
VCC1_8
2
Q65 2N3906
3
Q66 MMBT2222A
1
1
3
R871
470/6
R870 220/6
R868
200/6
2
1.8V/3.3V Power Sequencing Circuit
A A
Title
Size Document Number Rev
5
4
3
2
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
1.2V AND 1.8V VOLTAGE REGULATOR GA-8IPP533
1
53 58Tuesday, October 21, 2003
1.3
5
4
3
2
1
U107
FDS7760A
4
U109
FDS7760A
VCC3
4
EC67 680U/6.3V
3
L16
1.0UH/20A
D50 MBRS340T3
3
1 2
U108 FDS7760A
4
U110 FDS7760A
67825
1
67825
4
1
67825
3
1
67825
3
1
C1213
10U/12
C1613
0.1U/6
C1223 1U/6
EC84 820U/4V
EC111 680U/6.3V
VTT_DDR
EC85 820U/4V
MAX CURRENT
12.5A
C1656
0.1U/6
C1657 1U/6
12
1011 9 8 7 6 5 4 3 2 1
C1618 100P/6
C1616
0.1U/6
D68
MBR0520/X
PG_VTT
VTT_EN
VCC
VCC
R1831 10K/6
VTT_EN
C1614
0.1U/6
C1214
0.1U/6
C1224
4.7U/12
C1617
1U/6/X
R1836
2.2/6
R1841
2.2/6
R1837
2.2/6
R1842
2.2/6
+12V
C1620
0.1U/6
D D
VCC
84
U111A
REF_TRACK[52]
C C
3 2
3VSB
+
-
FAN5066_REF FAN5066_CNTRL
1
LM2904
R1225
0/6
R1838 47/6
C1619 1U/6
12
HIDRV
13
VCCQP
14
GNDD
15
GNDA
16
CNTRL
17
VID3
18
VID2
19
VID1
20
VREF
U167 FAN5066
C1615
0.1U/6
GNDPGNDP
LODRV
VID4 VCCP VCCA
VFB
IFB
PWRGD
ENABLE
CEXT
VCC
R1216 10K/6
PGOOD_1D25[48]
Q131 2N2222
R1343 10K/6
3
1
2
Q132
2N2222
3
R1344
2
10K/6
1
R1832 0/6/X
R1833
100K/6
PG_VTT
C1612
0.1U/6
B B
MH1
MB_HOLE
5 6 4 3 2
MH13
MB_HOLE
5 6 4 3 2
A A
5
7 8 9
1
5 6 4 3 2
5 6 4 3 2
5 6 4 3 2
1
MH2 MB_HOLE
1
MH3 MB_HOLE
1
MH4 MB_HOLE
1
4
7 8 9
MH6 MB_HOLE
7 8 9
5 6 4 3 2
7 8 9
1
MH7 MB_HOLE
7 8 9
5 6 4 3 2
7 8 9
1
MH8 MB_HOLE
7 8 9
5 6 4 3 2
7 8 9
1
MH9
MB_HOLE
5 6 4 3 2
1
MH10
MB_HOLE
1
MH11
MB_HOLE
5 6 4 3 2
1
MH12
MB_HOLE
5 6 4 3 2
1
3
7 8 9
7 8 9
7 8 9
FD1
1
Fiducial Mark
FD2
1
Fiducial Mark
FD3
1
Fiducial Mark
FD4
1
Fiducial Mark
FD5
1
Fiducial Mark
FD6
1
Fiducial Mark
2
FD7
1
P1
1
P4
1
Fiducial Mark
FD8
1
POSITION
P2
1
POSITION
Fiducial Mark
POSITION
P3
1
POSITION
Title
Size Document Number Rev
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
1.25V VLOTAGE REGULATOR GA-8IPP533
54 58Tuesday, October 21, 2003
1
1.3
5
D D
4
3
2
1
PCI DEVICE
PCI 1
C C
PCI 4
PCI 5
PCI 6
PCI 7
PCI 8
PCI 9 P2_PB_AD19
B B
GIGABIT LAN
SCSI
ATI VGA
IDSEL REQ&GNT IRQ ROUTING
P1_PA_AD23
P1_PB_AD20
P1_PB_AD21
P2_PA_AD18
P2_PA_AD19
P2_PB_AD18
P1_PB_AD18
P1_PA_AD22
ICH3_AD25
P1_PA_REQ0_N , P1_PA_GNT0_N
P1_PA_REQ1_N , P1_PA_GNT1_N
P1_PA_REQ3_N , P1_PA_GNT3_N
P1_PB_REQ2_N , P1_PB_GNT2_N
P1_PB_REQ3_N , P1_PB_GNT3_N
P2_PA_REQ0_N,P2_PA_GNT0_N
P2_PA_REQ1_N , P2_PA_GNT1_N
P2_PB_REQ0_N , P2_PB_GNT0_N
P2_PB_REQ1_N , P2_PB_GNT1_N
P1_PB_REQ0_N , P1_PB_GNT0_N
P1_PA_REQ2_N , P1_PA_GNT2_N
ICH3_REQ0 , ICH3_GNT_0
P1_PA_IRQ0 , IRQ1 , SCSI_IRQA , SCSI_IRQB
P1_PA_IRQ1 , IRQ4 , IRQ5 , IRQ0
P1_PA_IRQ4 , IRQ5 , IRQ0 , IRQ1
P1_PB_IRQ2 , IRQ3 , IRQ4 , IRQ5
P1_PB_IRQ6 , IRQ7 , IRQ8 , IRQ9
P2_PA_IRQ0 , IRQ1 , IRQ2 , IRQ3
P2_PA_IRQ4 , IRQ5 , IRQ6 , IRQ7
P2_PB_IRQ0 , IRQ1 , IRQ2 , IRQ3
P2_PB_IRQ4 , IRQ5 , IRQ6 , IRQ7
P1_PB_IRQ0
P1_PB_IRQ1
SCSI_IRQA,IRQB(P1_PA_IRQ2,P1_PA_IRQ3)
ICH3_PIRQC
Zero Channel RAID Support Circuit
U131C
74LCX126
98
VCC3
C1368
0.1U/6
147
U131A
2 3
74LCX126
1
VCC3
147
U131B
5 6
74LCX126
4
U168
6
VCC
A
4 5
B C
1
BE
GND
PI5C3303
P1_PA_IRQ3 [22,26]
P1_PA_IRQ2 [22,26]
VCC
2 3
R1444
4.7K/6/X
SCSI_IDSEL [30]
VCC3
R1440
R1441
4.7K/6
4.7K/6
SCSI_IRQB[27,30] SCSI_IRQA[27,30]
P1_PA_AD22[22,27,30]
VCC3
R1442
4.7K/6
EMRL_ENL[27]
VCC3
R1443
4.7K/6
SLOT_1_TMS[27]
EN_IDSEL
VCC3
147
10
A A
Title
Size Document Number Rev
5
4
3
2
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
PCI IDSEL AND ROUTING
GA-8IPP533
55 58Tuesday, October 21, 2003
1
1.3
5
4
3
2
1
1.ADD LED1 ,R1715 FOR SYSEVENT LED FUNCTION. 8/16/2002
2.ADD PULL UP RESISTOR FOR IPMI_BEEP FUNCTION AT LOCATION R1716. 8/16/2002
3.ADD PULL UP RESISTOR FOR BMC_IDLED FUNCTION AT LOCATION R1717. 8/16/2002
D D
4.ADD PULL UP RESISTOR FOR BMC_I2CRST# FUNCTION AT LOCATION R1718. 8/16/2002
5.ADD PULL UP RESISTOR FOR CLEAR_CMOS FUNCTION AT LOCATION R1719. 8/16/2002
6.ADD PULL UP RESISTOR FOR I2C_UNLOCK FUNCTION AT LOCATION R1720. 8/16/2002
7.ADD PULL UP RESISTOR FOR HDD_FAIL FUNCTION AT LOCATION R1721. 8/16/2002
8.CHANGE PART VALUE FROM 0 OHM TO NA FOR DISABLE BMC CLEAR_CMOS FUNCTION AT LOCATION R1663.8/16/2002
9. DEL R1685 AND SEPARATE THE BOTH NETS OF CPU1_SMI_N AND CPU0_SMI_N.8/21/2002
10.CHANGED Q142 FROM 2N222 TO 2N7002 TO FIX THE OS SHUT DOWN ISSUE. 8/20/2002
11.CHANGED Q141 FROM 2N222 TO 3904 TO FIX THE OS SHUT DOWN ISSUE. 8/20/2002
12.CHANGED THE RESISTOR VALUE FROM 4.7K TO 100OHM AT LOCATION R1566 TO FIX OS SHUT DOWN ISSUE. 8/30/2002
13.CHANGED THE RESISTOR VALUE FROM 100 OHM TO 4.7K AT LOCATION R1651 TO FIX OS SHUT DOWN ISSUE. 8/30/2002
14.ADD 51K(R1723) RESISTOR TO SET SYSTEM BOOT FROM CPU0 WHEN NOT INSTALL IPMI. 8/30/2002
15.CHANGED R135,R136 VALUE FROM 47OHM TO 49.9 OHM 1% TO SUPPORT E7501.8/30/2002
C C
16.CHANGED R137 VALUE FROM 6.81OHM TO NA AND R1404 FROM NA TO 25OHM 1% TO SUPPORT E7501.8/30/2002
17.CHANGED R138 VALUE FROM 6.81OHM TO NA AND R1405 FROM NA TO 25OHM 1% TO SUPPORT E7501.8/30/2002
18.CHANGED R1406,R1407 VALUE FROM 0 OHM TO NA TO SUPPORT E7501.8/30/2002
19.DELETE R1700,R1537,R1534,R1533,Q137,Q139,R1538,R1535,R1536,Q138 TO REMOVE NMI LEVEL SHIFT CIRCUIT.8/30/2002
20.ADD 10K PULL UP RESISTOR FOR BMC_NMI_OUT AT LOCATION R1727.8/30/2002
21.CHANGE THE RESISTOR VALUE FROM 4.7K TO NA TO ENABLE COM PORT WHEN NOT INSTALL IPMIAT LOCATION R1594.8/30/2002
22.CHANGE THE VALUE FROM SZ1284 TO NA AT LOCATION U145 FOR FSC REQUEST.8/30/2002
23.ADD 0OHM 8P4R RESISTOR FOR COM PORT FOR FSC REQUEST AT LOCATION RN252,RN253,RN254,RN255.8/30/2002
24.ADD RESISTOR(R1728 330) TO CONTROL POWER LED BY BMC.9/2/2002
25.CHANGED RESISTOR VALUE FROM 330 TO NA TO DISABLE POWER LED CONTROL BY SIO AT LOCATION R1015.2/9/2002
26.CHANGED THE NETS CONNECTION OF IPMI_PWRBT_IN_N AND BMC_PWR_SW_OUT_N TO FOLLOW FSC SPEC.9/2/2002
27.CHANGED THE RESISTORS VALUE FROM NA TO 0 OHM TO SUPPORT POWER ON/OFF CONTROL BY BMC AT LOCATION R1706,R1708.9/2/2002
B B
28.ADD NETS OF ADM_PWM1,ADM_PWM2 FROM ADM1026 TO BOARD TO BOARD CONNECTOR.9/3/2002
29.ADD NETS OF FAN0,FAN1,FAN3 FROM ADM1026 TO BOARD TO BOARD CONNECTOR.9/3/2002
30.ADD NETS OF BMC_PWM1,BMC_PWM2 FROM IPMI CONNECTOR TO BOARD TO BOARD CONNECTOR.9/3/2002
31.CONNECT ICH3 GPO20,GPO21 TO DISABLE CPU CIRCUIT.9/3/2002
32.CHANGED RESISTORS VALUE FROM 1K TO 10K AT LOCATION R104,R1189 FOR RESET CPU HOT CIRCUIT.9/3/2002
33.CHANGED RESISTORS VALUE FROM 10K TO 1K AT LOCATION R103,R1188 FOR RESET CPU HOT CIRCUIT.9/3/2002
34.CHANGED RESISTORS VALUE FROM 56 OHM TO 470 AT LOCATION R1673,R1190 FOR RESET CPU HOT CIRCUIT.9/3/2002
36.CHANGED RESISTORS VALUE FROM 10K TO 470 AT LOCATION R105,R1192 FOR RESET CPU HOT CIRCUIT.9/3/2002
37.ADD U135 SN74AHC74 AND R1729~R1733 1K FOR RESET CPU HOT CIRCUIT.9/3/2002
38.DELETE R1695(10K),R1696(1K),R1697(10K),R1698(1K) FROM THE NETS OF IPMI_PROC0_HOT_N AND IPMI_PROC1_HOT_N.9/3/2002
39.ADD 470 OHM RESISTORS FOR FORCEPR# FUNCTION AT LOCATION R1736,1737.R1740,R1741.9/3/2002
40.ADD 1K RESISTORS FOR FORCEPR# FUNCTION AT LOCATION R1738,1742.9/3/2002
41.ADD 2N2222 FOR FORCEPR# FUNCTION AT LOCATION Q170,Q171.9/3/2002
A A
42.DEL PULL UP RESISTOR OF GN+ AT LOCATION R945.9/4/2002
43.DEL PULL UP RESISTORS OF LPT BUS AT LOCATION R248~RN251,R1711.9/4/2002
44.DEL R706 OF P2_CLK66( HUB LINK CONNECTOR).9/4/2002
5
4
3
2
Title
Size Document Number Rev
Date: Sheet of
GIGA-BYTE TECHNOLOGY CO., LTD.
HISTORY
GA-8IPP533
56 58Tuesday, October 21, 2003
1
1.3
V0.2
5
A.PAGE5
1.CHANGE R37,R38 VALUE FORM 100 TO 86.6 FOR NOCONA CPU
2.CHANGE R22~R25, R28~R30 VALUE FORM 1K TO 49.9 FOLLOW INTEL DG
3.CHANGE R2 VALUE FORM 56 TO 200 FOLLOW INTEL SCH REVIEW
4.CHANGE R4 VALUE FORM 300 TO 200 FOLLOW INTEL SCH REVIEW
B.PAGE6
1.DEL R1684 VALUE FORM 0 TO NA FOR NOCONA CPU
2.CHANGE R1685 VALUE FORM 0 TO 49.9 FOR NOCONA CPU
3.CHANGE R43,R44 VALUE FORM 300 TO 200 FOLLOW INTEL SCH REVIEW
D D
C.PAGE 7
1.CHANGE R81,R82 VALUE FORM 100 TO 86.6 FOR NOCONA CPU
2.CHANGE R72~R78 VALUE FORM 1K TO 49.9 FOLLOW INTEL DG
3.ADD R1687~R1691 VALUE FORM NA TO 40.2 FOR NOCONA CPU
4.ADD C1590~C1594 FORM NA TO 47P FOR NOCONA CPU
5.CHANGE R71 FORM 1K TO 49.9 FOLLOW INTEL DG
D.PAGE8
1.DEL R1693 VALUE FORM 0 TO NA OR NOCONA CPU
2.CHANGE R1694 VALUE FORM 0 TO 49.9 FOR NOCONA CPU
E.PAGE11
1.DEL R114,R115 VALUE FORM 24.9 TO NA FOR E7501
2.DEL R120 , R121 VALUE FORM 453 TO NA FOR E7501
3.DEL R124,R125 FORM 499 TO NA FOR E7501
4.DEL C136,C138,C144,C146 FORM 0.1U TO NA FOR E7501
5.DEL C137,C19,C145,C147 FORM 0.01U TO NA FOR E7501
6.CHANGE R113 VALUE FORM 100 TO 86.6 FOR NOCONA CPU
F.PAGE13
1.CHANGE R169.1 NET FORM V_CORE TO VCC1_2 FOLLOW INTEL DG
G.PAGE17
1.CHANGE RN23~RN52 VALUE FORM 22/8P4R TO 39/8P4R FOR E7501
H.PAGE21
1.CHANGE RN75~RN104 VALUE FORM 22/8P4R TO 39/8P4R FOR E7501
I.PAHE29
1.CHANGE R1506,RP5 VALUE FORM 1K , 1K/8P4R TO 150,150/8P4R TO FIX FDD DETECT FAIL
2.CHANGE R491 VALUE FORM 1K TO 4.7K TO FIX CDROM DETECT FAIL
C C
3.CHANGE R491.2 NET FORM VCC TO VCC3 TO FIX CDROM DETECT FAIL
4.CHANGE R496.2 NET FORM VCC TO VCC3 TO FIX CDROM DETECT FAI
J.PAGE30
1SWAP J13.A74,A75 NET TO FIX BACK PLANE FAN DETECT FAIL
K.PAGE31.32.33.34
1.CHANGE GIGA LAN CIRCUITE FORM 82545 TO 82546
L.PAGE36
1.CHANGE R427 VALUE FORM 4.7K TO 8.2K FOLLOW INTEL DG
2.CHANGE R437 VALUE FORM 10K TO 0 FOLLOW INTEL DG
3.CHANGE R823 VALUE FORM 56 TO 200 FOLLOW INTEL SCH REVIEW
M.PAGE37
1.CHANGE RN184.5.7 NET FORM 5VSB TO 3VSB FOLOW INTEL DG
2.CHANGE R1612 VALUE FORM 4.7K TO NA FOLLOW INTEL DG
3.CHANGE R445 VALUE FORM 27 TO 18.2 FOLLOW INTEL DG
4.ADD R1839 8.2K TO PULL UP U23.V4 FOLLOW NTEL DG
N.PAGE38
1.ADD NEW NET VBAT_ADM TO ADM(U153)
O.PAGE39
1.ADD RESISTOR R1845,R1846 FOR IPMI_PWRBT_IN_N CIRCUIT
P.PAGE40
1.CHANGE ADM(U153) HARDWARE MONITOR VOLTAGE
2.CHANGE R1710 VALUE FORM NA TO 10M FIX CASEOPEN ISSUE
B B
Q.PAGE41
1.CHANGE COM2.5, CP6 , CP5 NET FORM EGND TO GND
2.CHANGE R1640 VALUE FORM 0 TO NA FIX COM2 FAIL
R.PAGE46
1.ADD R1828,R1676 0 OHM & DEL Q134 ,R1530 TO NA FOR FSB400/533 SELECT CIRCUITR
S.PAGE49
1.CHANGE J9 LIB FORM ATXA TO ATXB TO SUPPORT NEW POWER
T.PAGE52
1.CHANGE D51 VALUE FORM NA TO BAT54 FIX POWERGOOD ISSUE
U.PAGE54
1.CHANGE VTT_DDR CIRCUITE FORM LTC1735CGN TO FAN5066
W.PAGE55
1.CHANGE 3303 CIRCUITE
A A
5
4
V0.3 FSC
A.PAGE12
1.DEL R155 ~ R160 PART FOLLOW INTEL REVIEW
B.PAGE23
1.CHANGE R261 VALUE FROM NA TO 8.2K & R1425 VALUE FORM
8.2K TO NA TO SUPPORT 100 MHz PCIX
C.PAGE27
1.ADD NEW PART R1875 TO CHANGE PCI1 IDSEL
D.PAGE29
1.ADD NEW PART R1864 & R1861 TO SUPPORT GC-IL1E LED BOARD
E.PAGE30
1.ADD NEW PART R1847 & R1848 TO SEL FAN_SENSE2
2.ADD NEW PART R1849 & R1850 TO SEL FAN_SENSE5
F.PAGE35
1.ADD NEW PART R1862 & R1863 TO SUPPORT GC-IL1E LED BOARD
2.DEL PART Q164 & Q165 TO SUPPORT GC-IL1E LED BOARD
3.CHANGE R1340,R1341,R1342 NET FROM 5VSB TO 3VSB TO SUPPORT GC-IL1E LED BOARD
G.PAGE37
1.ADD NEW NET ICH3_GPO23 & ICH3_GPO22 TO SUPPORT FIRMWARE HUB FLASH JUMPLESS
2.ADD NEW PART R1865 & R1866 TO SUPPORT FIRMWARE HUB FLASH JUMPLESS
3.ADD NEW PART R1867 ~ R1872 TO SUPPORT M/B ID SEL
H.PAGE40
1.CHANGE ADM(U153.40) HARDWARE MONITOR VOLTAGE FROM 3VSB TO 1_8SB
2.ADD NEW PART R1873 & R1874 TO SUPPORT U153 I2C ADDRESS
H.PAGE41
1.DEL PART U145
2.CHANGE RN252 & RN253 NET TO SUPPORT NON IPMI COM1 SOLUTION
3.ADD NEW PART FB61,FB62 TO SUPPORT EMI SOLUTION
4.CHANGE COM1 GND NET TO SUPPORT EMI SOLUTION
I.PAGE42
1.CHANGE CN1 GND NET TO SUPPORT EMI SOLUTION
J.PAGE45
1.ADD NEW PART C1632,C1633 TO SUPPORT EMI SOLUTION
2.CHANGE CN2 GND NET TO SUPPORT EMI SOLUTION
3.CHANGE C862 ~ C868 & BC14 GND NET TO SUPPORT EMI SOLUTION
K.PAGE46
1.ADD NEW PART R1852 , R1853 , Q191 TO FIX P64H2 POWER ON FAIL
2.ADD NEW NETV18_PGOOD TO FIX P64H2 POWER ON FAIL
L.PAGE49
1.ADD NEW PART C1635 , C1634 C1636 , C1637
M.PAGE50
1.CHANGE R905 PART VALUE FORM 2.61K 1% TO 2.2K 1% TO FIX CPU TRANSIENT
2.DEL R901 PART VALUE TO FIX CPU TRANSIENT
4
3
V0.3 OPTIONAL BOM
A.THE FUNCTION IS DIFFERENCE BETWEEN SR125P AND SR125
(1).CHANGE HARDWARE MONITOR FUNCTION FORM ADM1206 TO SUPER I/O (PC87366 VOLTAGE SENSER) & BACK PLANE GC-SSBIE (83791 FAN SENSER) (2).CHANGE COM1 NET FROM IPMI ( EMP ) PORT TO SUPER I/O (PC87366) (3).CHANGE LED BOARD FROM GC-IL1F TO GC-IL1E (4).CHANGE BRIDGE BOARD FROM GC-SST1F
TO GC-SSTIE (5).CHANGE BACK PLANE FROM GC-SSBIF
TO GC-SSBIE
REV:0.4
(1) PAGE51: ADD SC412,SC413,R1880,R1885
(2) PAGE50: ADD U170 (3) PAGE49: ADD SC414,SC415 (4) PAGE46: ADD C1651 (5) PAGE42: ADD R1886 (6) PAGE36: ADD U169 (7) PAGE34: ADD EC110
REV:0.5
2:PAGE 42 ADD D69 TO SOLVE WHEN CPU THERMAL IS ACTIVE,SYSTEM WILL POWER OFF
3:PAGE 41 ADD R1888,R1889,R1891,R1892
FOR ADM213 TO SELECT 5V OR 5VSB
4:PAGE 45 ADD R1893,R1894 TO SOLVE HSYNC AND VSYNC SIGNAL QUALITY 5:PAGE 36 ADD R1887 TO PULL DOWN
BMC_NMI_OUT SIGNAL WHEN IPMI MODULE ISN'T INSTALL
6:PAGE9 U67 PIN2,PIN5 CONNECT TO 3VSB TO FORCE THERMALTRIP SIGNAL IS HIGH WHEN SYSTEM POWER OFF
7:PAGE24 ADD SC416,SC417 TO FILTER NOISE OF VCC1_8
8:PAGE41 ADD Q194,R1890 TO REPLACE U142(TTL INVERTER)FOR REDUCING LEAKAGE VOLTAGE 9:PAGE37 ADD BIOS_RECOVERY JUMPER J37
10:PAGE 29 ADD R1905,R1906,Q196 TO DISPLAY THE CORRECT POWER_LED FUNCTION
11:PAGE 51 JP14 MOVE CLOSE TO U27 FOR MECHANICAL ISSUE
12:PAGE 37 ADD R1897,R1898,R1899,R1900,R1901,R1902 TO FIX SMBUS VOLTAGE DROP ISSUE WHEN POWER ON OR POWER OFF
13:PAGE 54 DELETE EC77,L15 CHANGE TO HORIZONTAL FOR MECHENICAL ISSUE
14:PAGE 9 MODIFY CPU REDUCTION CIRCUIT U150
3
2
REV:1.0
1:PAGE9 ADD C1652,C1653 TO FILTER NOISE
2:PAGE33,ADD R1908,Q197,Q198 TO ENABLE/DISABLE LAN
3:PAGE39,ADD R1909 4:PAGE37,CONNECT ICH3_LDRQ1_N
TO IPMI
REV:1.1
1:PAGE41 ADD U172 TO MIDIFY ID LED FUNCTION
REV:1.2
1:PAGE30 CHANGE SCSI CONNECTOR PIN VCC18 TO VCC3
2:PAGE34,CHANGE EC108 TO 680U FROM 220U
3:PAGE33,ADD R1911,C1655,Q199,R1912,R1913 TO MODIFY LAN_PWROK SIGNAL
4:PAGE7,ADD PULL UP R1914 FOR PROC1_HOT_N SIGNAL
5:PAGE36,ADD R1917,R1918 TO DELAY PCIRESET SIGNAL FOR P64H2
6:PAGE29,ADD R1915 FOR IDE_RST SIGNAL PULL UP
REV:1.3
1:PAGE 33 ADD U173,U174 FOR LAN DISABLE
2:PAGE 37,ADD U175,R1924 FOR LAN DISABLE
3:PAGE 27,ADD C1658 FOR PCIX SLOT CLOCK TUNNING
4:PAGE 28,ADD C1659 FOR PCIX SLOT CLOCK TUNNING
5:PAGE 27,CONNECT PIN 3VAUX TO VCC3_DUAL
6:PAGE 28,CONNECT PIN 3VAUX TO VCC3_DUA
7:PAGE 54 ADD EC111 FOR VCC3 DECOUPLING
GIGA-BYTE TECHNOLOGY CO., LTD.
Title
HISTORY-1
Size Document Number Rev
2
Date: Sheet of
1
GA-8IPP533
1
57 58Tuesday, October 21, 2003
1.3
5
4
3
2
1
HARDWARE MONITOR BLOCK DIAGRAM
D D
CPU1 EEPROM
ICH3
CPU0 EEPROM
SMBUS0
ICH3 SMBUS
C C
CONTROL CIRCUIT
PCA9544
BMC SMBUS
VCC1_2 VTT_DDR VCC1_8 VCC2_5 VCC1_8DUAL VCC1_5DUAL VCC2_5DUAL(LAN) V_CORE
IPMI MODULE
B B
FAN_PWM1 FAN_PWM2
CPU0_THERMDA CPU0_THERMDC
CPU1_THERMDA CPU1_THERMDC
CPU0_HOT_N CPU1_HOT_N
PS_ON_N
ADM1026
PWM
+12V
-12V VCC V_BAT VCC3
FAN_SENSE3
5
FAN_SENSE4
6
FAN_SENSE5
9
FAN_SENSE1
3
FAN_SENSE2
4
DAC
SMBUS1
LM75 LM75LM75LM75 CPU1CPU0 DDR
SCSI
BRIDGE BOARD
FAN_SENSE3 FAN_SENSE4 FAN_SENSE5 FAN_SENSE1 FAN_SENSE2
ADM1026 DAC ADM1026 PWM BMC PWM1 BMC PWM2
PS FAN1
PS FAN2
Housing FAN
CPU FAN1
BLACKPLANE
74HCT4052
Z2 Z1
Y1_3
Y1_0
Y2_2
Y1_2
Y2_1
Y2_0
Y1_1
Y2_3
CPU
CPU
CPU
FAN4
FAN2
FAN3
CPU FAN5
CPU FAN6
CPU FAN7
CPU FAN8
A A
GIGA-BYTE TECHNOLOGY CO., LTD.
Title
HARDWARE MONITOR DIAGRAM
Siz e Document Number Rev
5
4
3
2
Date: Sheet of
GA-8IPP533
1
58 58Tuesday, October 21, 2003
1.3
Loading...