Vivo 40 with Target Volume
To ensure a successful transition from hospital to home,
healthcare providers seek respiratory solutions that can
be trusted, make life easier and enjoy dedicated personal
support. Moreover, serviceability and cost of ownership
must meet increasingly strict demands.
A device you can trust
The Vivo ventilators are well trusted by patients and care givers
as proven by more than 30,000 units sold worldwide. The Vivo 40*
provides both invasive and non-invasive support in PSV, PCV and
CPAP mode. The adult and pediatric modes allow Vivo 40 to be used
by a wide range of patients.
Thanks to eSync*, the highly responsive trigger technology, the Vivo 40
synchronizes smoothly with the patient’s breathing eort, leading to
lower the work of breathing and higher the level of comfort.
The Target Volume feature aims
for a stable tidal volume by automatically adapting the inspiratory
pressure to the lung mechanics of the
patient. Target Volume combines the
comfort and technical advantages
of pressure ventilation with the ease
of use of volume ventilation.
To ensure excellent control of the treatment, there are many ways
to adapt the settings to the need of the individual patient. Apart
from IPAP and EPAP, also rise time, trigger sensitivity and optional
minimal and maximal Inspiratory Time can be set. The maximum
pressure is 40 cm H2O which allows for the treatment of challenging
restrictive conditions.
To provide security to patients and caregivers, the Vivo 40 contains a
comprehensive set of alarms and an internal battery for independent
use up to three hours. An external DC connection is available as an
additional power source.
“Vivo 40 is easy to use,
secure and effective”.
Dr Fernando Rua
Hospital de Santo António,
Porto (Portugal)
• Enhanced trigger
• Enhanced display and look
• Improved
humidification
“Vivo 40 is a pleasant device, easy to operate. The interface
is practical since it has no submenus – you directly reach the
set-up you want. Moreover, the screen is quite large enabling
you to see the settings and the patient parameters at the
same time.”
Dr Christine Cheval, Centre Hospitalier, Hyeres (France)
Making life easier for patients and caregivers
The user interface and menu structure of the Vivo 40 are intuitive and
consistent throughout the Vivo range. This makes the Vivo 40 easy to
learn and easy to teach. It facilitates situations where multiple sta
members work with the device. The optional humidier is completely
regulated through the ventilator and provides additional patient
comfort. If data analysis or reports are required, data can easily be
downloaded to a ash card.
• For paedriatic (>10 kg) and adult use.
• Target Volume stabilizes tidal volume delivery
• Appropriate for invasive and non-invasive use
• eSync feature for synchronized breath delivery
• Designed for use at Home or in the Hospital
• Large, easy-to-read display with simple menu structure
• Designed for a wide range of masks
• Oers 3 Ventilation modes, 2 Device modes,
2 Patient modes (adult/pediatric)
Large screen and
intuitive user interface
Designed for hospital and home environment
With its attractive Scandinavian design and small footprint the
Vivo 40 is highly suitable for both hospital and home environments.
The Vivo 40 will allow for a secure and comfortable transition from
hospital to home.
• Low noise <30dB(A)
• Extensive alarm package
• Internal 3 hour battery
• Integrated Heated Humidier
• Internal data/calendar memory
• Stable device with small footprint
• Large, easy-to-use buttons with backlight
• Worldwide mains power compatibility
• Flexible DC power options
Integrated humidier Enhanced trigger
function
Technical Specications
Settings/Performance
Ventilation Modes • PSV (Pressure Support Ventilation)
• PCV (Pressure Control Ventilation)
• PSV +Target Volume
• PCV +Target Volume
• CPAP (Continuous Positive Airway Pressure)
Patient Modes • Adult
• Paediatric (>10 kg)
Device Modes • Clinical
• Home
IPAP/EPAP 4 to 40 cmH2O / 2 to 20 cmH2O or IPAP -2 cmH2O
CPAP 4 to 20 cmH2O
Breath Rate 4 to 40 BPM
Inspiratory Time 0.3 to 5 s
Rise Time 1 to 9
Inspiratory Trigger (eSync) 1 to 9, O
Expiratory Trigger 1 to 9
Target Volume 200-1500 ml
Expiratory Trigger 1 to 9
Ramp function setting 10 – 60 min, O (PCV, PSV and CPAP mode)
Humidication setting 1 to 9 (10 to 30 mgH2O/L)
Audible alarm setting 1 to 9
Maximum ow > 200 litres/min
Minimal Inspiratory Time O, 0.3 – 3.0 s
Maximal Inspiratory Time 0.3 – 3.0 s, O
Noise level (at 10 cmH2O constant pressure) Less than 30 dB(A)
Indications
Pressure; bar graph and digital data 0 to 40 cmH2O
Calculated tidal volume accuracy ± 20%
Leakage calculation accuracy ± 20%
Total Breath Rate BPM (Breaths Per Minute)
I/E Ratio 1 :10 to 10 :1
Alarms
Audible Alarm Level 45 to 85 dB(A)
Low pressure alarm, High pressure alarm, Low volume alarm, Low breath rate alarm,
High breath rate alarm, Low leakage alarm, High leakage alarm, Low External DC Warning, Low internal battery warning, Low power alarm, Internal function failure alarms.
* Vivo by Breas and eSync are trademarks by General Electric Company.
© 2012 General Electric Company – All rights reserved.
General Electric Company reserves the right to make changes in specications and features
shown herein, or discontinue the product described at any time without notice or obligation.
Contact your GE representative for the most current information.
GE, the GE Monogram and imagination at work are trademarks of General Electric Company.
Breas Medical AB · Företagsvägen 1 · SE-435 33 Mölnlycke · Sweden
Phone +46 31 86 88 00 · Fax +46 31 86 88 10 · breasswe@ge.com · www.breas.com · www.gehealthcare.com
Power Supplies
Mains supply 100 to 240 V AC
Internal battery / External battery Capacity 3.8 Ah / 12/24 V DC
Operating Conditions
Recommended mask leakage 20 to 40 litres/min at 10 cmH2O
Minimum mask leakage 12 litres/min at 4 cmH2O
Dimensions
W x H x D 185 x 240 x 227 mm
Weight 4.0 kg
Air outlet 22 mm male conical standard connector