GE Healthcare GSI Viewer Brochure

Confident diagnosis with easier workflow
GE Healthcare
Gemstone Spectral Imaging (GSI) is a novel dual energy application that uses rapid kV switching to acquire the dual energy samples almost simultaneously to generate material density data that can be used for the separation of materials and derivation of monochromatic spectral images using a projection based reconstruction algorithm.
GSI has the exciting potential to be used as a routine scan acquisition mode offering additional anatomical and functional information to help expedite and assist in an accurate CT diagnosis.
Select from 101
monochromatic energy levels for image visualization.
Visualize virtual non-contrast
like image
View material density and
effective atomic number images to discriminate tissue type.
Use image overlay tool to fuse
material and effective atomic number information on monochromatic image
VOI tool to selectively visualize
a volume of interest.
GSI Viewer
Visit us:
www.gehealthcare.com/aw/
applications/gsi-viewer/
Features
Material Decomposed images
allow for the separation of materials like calcium, iodine, and water.
Visualize a virtual non-contrast like
image using the water-iodine basis pair image.
Adjusting monochromatic energy
levels can optimize image contrast and reduce beam-hardening artifacts.
Discriminate different tissue types
based on material density and monochromatic image data.
Image overlays to visualize
different material attributes in a single view.
Vessel analysis to evaluate the
extent of lumen occlusion when used with VesselIQ Xpress
Iodine suppressed images with the
dynamic range of regular CT images in addition to a virtual non­contrast like image using the water-iodine basis pair.
System Requirements
AW Workstation Volume Share 4. AW Server
Recommendations
16 GB RAM 2 display monitors (compatible with one or two monitor systems).
Regulatory Compliance
This product complies with the European CE marking regulation following Medical Devices Directive: Directive 93/42/EEC, dated 14 June
1993.
Intended Use
The GSI Viewer accepts images from a CT System that can acquire CT images using different kV levels of the same anatomical region of a patient in a single rotation from a single source. The differences in the energy dependence of the attenuation coefficient of the different materials provide information about the chemical composition of body materials. This approach enables images to be generated at energies selected from the available spectrum to visualize and analyze information about anatomical and pathological structures. GSI provides information of the chemical composition of renal calculi by calculation and graphical display of the spectrum of effective atomic number. GSI Kidney stone characterization provides additional information to aid in the characterization of uric acid versus non-uric acid stones. it is intended to be used on non-contrast studies as an adjunct to current standard methods for evaluating stone etiology and composition.