GE Healthcare FlightPlan Brochure

A breakthrough in liver embolization.
GE Healthcare
Overview
To deliver therapeutic material to tumors during transarterial chemoembolization therapy, identifying the liver’s vessels accurately is essential to the success of intervention.
But the liver’s complex vasculature can make precise identification of
tumor-feeding vessels in 2D and 3D images a challenge, often requiring significant amounts of time, radiation, and contrast media.
Intuitive 3-step operation
streamlines your workflow.
Automatically highlights
vessels traveling to the tumor’s
vicinity.
You can use identified vessels
as 3D roadmaps with Innova* Vision1.
FlightPlan for Liver
Visit us:
www.gehealthcare.com/aw/
applications/
plan their liver embolization procedures. It automatically highlights vessels travelling from the catheter tip to the vicinity of a hypervascular lesion.
Features
FlightPlan for Liver processes Innova 3D models providing you with a guided and intuitive 3-step workflow
Extract the hepatic vasculature
with one click on the catheter’s tip
location
Automatic segmentation of
hepatic atrial tree
Easily select the hypervascular
tumor using the target tool
FlightPlan for Liver automatically
highlights vessels traveling to the tumor’s vicinity
Indications for Use
FlightPlan for Liver is a post processing software package that helps the analysis of 3D X-ray images of the liver arterial tree. Its output is intended as an adjunct means to help identify arteries leading to the vicinity of hypervascular lesions in the liver. This adjunct information may be used by physicians to aid them in their evaluation of hepatic arterial anatomy during embolization procedures.
Regulatory Compliance
This product complies with the European Council Directive 93/42/EEC Medical Device Directive as amended by European Council Directive 2007/47/EC.
Vessels leading to the vicinity of
the lesion highlighted in green
With FlightPlan for Liver, you can also
Manually add or remove vessels
for more accurate evaluation
Show, hide, and change the
opacity vessels separately
Export in a single click the
vessels highlighted by FlightPlan for Liver to Innova Vision1 and overlay them over fluoroscopic image for live 3D guidance
System Requirements
AW VolumeShare 4 or higher
© 2012 General Electric Company.
All rights reserved. Data subject to change.
GE and GE Monogram are trademarks of General Electric Company.
* Trademark of General Electric Company
1
Requires Innova Vision option.