Process Automation Control Systems |
|
VersaMax Control |
||
|
|
|
|
|
|
Discrete Mixed I/O Modules |
|
|
|
|
Discrete mixed modules provide maximum flexibility by combining inputs and outputs in a single, |
|||
|
compact module.. Discrete input modules receive signals from input devices such as sensors, |
|||
|
pushbuttons, and switches that can have two states: on or off, open or closed.. Discrete output modules |
|||
|
send control signals to devices such as contactors, indicator lamps, and interposing relays that can also |
|||
|
have two states.. Discrete mixed modules provide maximum flexibility by combining inputs and outputs in |
|||
|
a single, compact module.. Modules require a carrier base (IC200CHSxxx).. |
|||
|
IC200MDD840 |
IC200MDD842 |
IC200MDD843 |
|
|
|
|
|
|
|
VersaMax Discrete Mixed Modules, |
VersaMax Discrete Mixed Modules |
VersaMax Discrete Mixed Modules |
|
Product Name |
24 VDC Pos Logic Input 20 points/ |
24 VDC Pos Logic Input 16/Output |
24 VDC Positive Logic Input |
|
|
Output Relay 2..0 A, 12 points |
24 VDC 0..5 A with ESCP |
10/Output Relay 6 |
|
|
|
|
|
|
Lifecycle Status |
Active |
Active |
Active |
|
|
|
|
|
|
Input Voltage |
24 VDC |
24 VDC |
24 VDC |
|
|
|
|
|
|
|
0-125 VDC, 5/24/125 VDC nominal; |
24 VDC |
0-125 VDC, 5/24/125 VDC nominal; |
|
Output Voltage |
0-265 VAC (47-63 Hz), |
|
0-265 VAC (47-63 Hz), |
|
|
120/240 VAC nominal |
|
120/240 VAC nominal |
|
|
|
|
|
|
Number of Points |
20 in/12 out |
16 in/16 out |
10 in/6 out |
|
|
|
|
|
|
Channel to Channel Isolation |
No |
No |
No |
|
|
|
|
|
|
Load Current per Point |
2..0 A for 5-265 VAC, 2..0 A for 5-30 VDC |
0..5 A for 30 VDC |
2..0 A for 5-265 VAC, 2..0 A for 5-30 VDC, 0..2 A |
|
|
|
for 31-125 VDC |
||
|
|
|
||
|
|
|
|
|
Input and Output Response |
0..5 and 10 |
0..5 and 0..5 |
0..5 and 10 |
|
TimeOn/Off(ms) |
||||
|
|
|
||
|
|
|
|
|
Protection |
No internal fuses or snubbers |
Short circuit protection, overcurrent |
No internal fuses or snubbers |
|
|
protection, free-wheeling diodes |
|
||
|
|
|
||
|
|
|
|
|
On State Current |
2..0-5..5 mA |
2..0-5..5 mA |
2..0-5..5 mA |
|
|
|
|
|
|
Off State Current |
0-0..5 mA |
0-0..5 mA |
0-0..5 mA |
|
|
|
|
|
|
External Power Supply |
0-125 VDC, 5/24/125 VDC nominal; 0-265 |
18-30 VDC, 24 VDC nominal |
0-125 VDC, 5/24/125 VDC nominal, 0-265 |
|
VAC (47-63 Hz), 120/240 VAC nominal |
|
VAC (47-63 Hz), 120/240 VAC nominal |
||
|
|
|||
|
|
|
|
|
Input Impedance |
10 kOhms maximum |
10 kOhms maximum |
10 kOhms maximum |
|
|
|
|
|
|
|
2..0 A for 5-265 VAC or |
0..5 Amp at 30 VDC |
10 mA per point minimum, |
|
|
5-30 VDC, 0..2 A for 31-125 VDC |
maximum (resistive); |
8..0 A maximum per module; |
|
|
|
2..0 Amps maximum for |
2..0 Amps for 5 to 265 VAC |
|
Load Current |
|
100ms inrush |
maximum (resistive); |
|
|
|
2..0 Amps for 5 to 30 VDC |
||
|
|
|
||
|
|
|
maximum (resistive); |
|
|
|
|
0..2 Amp for 31 to 125 VDC |
|
|
|
|
maximum (resistive) |
|
|
|
|
|
|
5V Backplane Current |
375 maximum |
100 maximum |
190 maximum |
|
Consumption (mA) |
||||
|
|
|
||
|
|
|
|
|
|
One LED per point shows individual |
One LED per point shows individual |
One LED per point shows individual |
|
LED Indicators |
point on/off state (logic side); OK LED |
point on/off state (logic side); OK LED |
point on/off state (logic side); OK LED |
|
|
indicates backplane power is present |
indicates backplane power is present |
indicates backplane power is present |
|
|
|
|
|
|
|
110 mm (4..3 in) x 66..8 mm (2..63 in) x |
110 mm (4..3 in) x 66..8 mm (2..63 in) x |
110 mm (4..3 in) x 66..8 mm (2..63 in) x |
|
Dimensions (W x H x D) |
50 mm (1..956 in), not including the |
50 mm (1..956 in), not including the |
50 mm (1..956 in), not including the |
|
height of the carrier or the |
height of the carrier or the |
height of the carrier or the |
||
|
||||
|
mating connectors |
mating connectors |
mating connectors |
|
|
|
|
|
www.geautomation.com |
Automation & Control Systems 1..123 |
VersaMax Control |
Process Automation Control Systems |
|
|
|
Discrete Mixed I/O Modules |
|
Discrete mixed modules provide maximum flexibility by combining inputs and outputs in a single, |
|
compact module.. Discrete input modules receive signals from input devices such as sensors, |
|
pushbuttons, and switches that can have two states: on or off, open or closed.. Discrete output modules |
|
send control signals to devices such as contactors, indicator lamps, and interposing relays that can also |
|
have two states.. Discrete mixed modules provide maximum flexibility by combining inputs and outputs in |
|
a single, compact module.. Modules require a carrier base (IC200CHSxxx).. |
|
IC200MDD844 |
IC200MDD845 |
IC200MDD846 |
|
|
|
|
|
|
|
VersaMax Discrete Mixed |
VersaMax Discrete Mixed |
VersaMax Discrete Mixed Modules |
|
Product Name |
Modules 24 VDC Positive Logic |
Modules 24 VDC Positive Logic Input |
120 VAC Input 8 points/Outpoints |
|
|
Input 16/Output 24 VDC 0..5 A 16 points |
16/Output Relay 2..0A Isolated 8 points |
Relay 2..0A Isolated 8 points |
|
|
|
|
|
|
Lifecycle Status |
Active |
Active |
Active |
|
|
|
|
|
|
Input Voltage |
24 VDC |
24 VDC |
120 VAC |
|
|
|
|
|
|
|
24 VDC |
0-125 VDC, 5/24/125 VDC nominal; |
0-125 VDC, 5/24/125 VDC nominal; |
|
Output Voltage |
|
0-265 VAC (47-63 Hz), |
0-265 VAC (47-63 Hz), |
|
|
|
120/240 VAC nominal |
120/240 VAC nominal |
|
|
|
|
|
|
Number of Points |
16 in/16 out |
16 in/8 out |
8 in/8 out |
|
|
|
|
|
|
Channel to Channel Isolation |
No |
Yes, outputs |
Yes, outputs |
|
|
|
|
|
|
Load Current per Point |
0..5 A for 30 VDC |
2..0 A for 5-265 VAC, 2..0 A for 5-30 VDC, |
2..0 A for 5-265 VAC, 2..0 A for 5-30 VDC, |
|
|
0..2 A for 31-125 VDC |
0..2 A for 31-125 VDC |
||
|
|
|||
|
|
|
|
|
Input and Output Response |
0..5 and 0..2 ON / 1..0 OFF |
0..5 and 10 |
1 AC cycle minimum and 2 AC cycle |
|
TimeOn/Off(ms) |
(Hz dependent) maximum and 10..0 OFF |
|||
|
|
|||
|
|
|
|
|
Protection |
No internal fuses |
No internal fuses or snubbers |
No internal fuses or snubbers |
|
|
|
|
|
|
On State Current |
2..0-5..5 mA |
2..0-5..5 mA |
5 mA minimum |
|
|
|
|
|
|
Off State Current |
0-0..5 mA |
0-0..5 mA |
2..5 mA maximum |
|
|
|
|
|
|
External Power Supply |
18-30 VDC, 24 VDC nominal |
0-125 VDC, 5/24/125 VDC nominal; |
0-125 VDC, 5/24/125 VDC nominal; |
|
|
0-265 VAC (47-63 Hz), 120/240 VAC nominal |
0-265 VAC (47-63 Hz), 120/240 VAC nominal |
||
|
|
|||
|
|
|
|
|
Input Impedance |
10 kOhms maximum |
10 kOhms maximum |
8..6 kOhms (reactive) at 60 Hz, typical; |
|
|
|
10..32 kOhms (reactive) at 50 Hz, typical |
||
|
|
|
||
|
|
|
|
|
|
0..5 Amp at 30 VDC maximum (resistive) 2..0 |
10 mA per point minimum |
10 mA per point minimum |
|
Load Current |
Amps maximum for 100ms inrush |
2..0 A for 5 to 265 VAC maximum (resistive) |
2..0 A for 5 to 265 VAC maximum (resistive) |
|
|
2..0 A for 5 to 30 VDC maximum (resistive) |
2..0 A for 5 to 30 VDC maximum (resistive) |
||
|
|
|||
|
|
0..2 A for 31 to 125 VDC maximum (resistive) |
0..2 A for 31 to 125 VDC maximum (resistive) |
|
|
|
|
|
|
5V Backplane Current |
70 maximum |
270 maximum |
300 maximum |
|
Consumption (mA) |
||||
|
|
|
||
|
|
|
|
|
|
One LED per point shows individual |
One LED per point shows individual |
One LED per point shows individual |
|
LED Indicators |
point on/off state (logic side); OK LED |
point on/off state (logic side); OK LED |
point on/off state (logic side); OK LED |
|
|
indicates backplane power is present |
indicates backplane power is present |
indicates backplane power is present |
|
|
|
|
|
|
|
110 mm (4..3 in) x 66..8 mm (2..63 in) x |
110 mm (4..3 in) x 66..8 mm (2..63 in) x |
110 mm (4..3 in) x 66..8 mm (2..63 in) x |
|
Dimensions (W x H x D) |
50 mm (1..956 in), not including the |
50 mm (1..956 in), not including the |
50 mm (1..956 in), not including the |
|
height of the carrier or the |
height of the carrier or the |
height of the carrier or the |
||
|
||||
|
mating connectors |
mating connectors |
mating connectors |
|
|
|
|
|
1..124 Automation & Control Systems |
www.geautomation.com |
Process Automation Control Systems |
|
VersaMax Control |
||
|
|
|
|
|
|
Discrete Mixed I/O Modules |
|
|
|
|
Discrete mixed modules provide maximum flexibility by combining inputs and outputs in a single, |
|||
|
compact module.. Discrete input modules receive signals from input devices such as sensors, |
|||
|
pushbuttons, and switches that can have two states: on or off, open or closed.. Discrete output modules |
|||
|
send control signals to devices such as contactors, indicator lamps, and interposing relays that can also |
|||
|
have two states.. Discrete mixed modules provide maximum flexibility by combining inputs and outputs in |
|||
|
a single, compact module.. Modules require a carrier base (IC200CHSxxx).. |
|||
|
IC200MDD847 |
IC200MDD848 |
IC200MDD849 |
|
|
|
|
|
|
|
VersaMax Discrete Mixed Modules |
VersaMax Discrete Mixed Modules |
VersaMax Discrete Mixed Modules |
|
Product Name |
240 VAC Input 8 points/Output Relay |
120 VAC Input 8 points/Output |
120 VAC Input Isolated 8 points/Output |
|
|
2..0A Isolated 8 points |
120 VAC 0..5A Isolated 8 points |
Relay 2..0 A Isolated 8 points |
|
|
|
|
|
|
Lifecycle Status |
Active |
Active |
Active |
|
|
|
|
|
|
Input Voltage |
240 VAC |
120 VAC |
0-132 VAC (47 to 63 Hz), 120 VAC nominal |
|
|
|
|
|
|
|
0-125 VDC, 5/24/125 VDC nominal; |
120 VAC |
0-125 VDC, 5/24/125 VDC nominal; |
|
Output Voltage |
0-265 VAC (47-63 Hz), |
|
0-265 VAC (47-63 Hz), |
|
|
120/240 VAC nominal |
|
120/240 VAC nominal |
|
|
|
|
|
|
Number of Points |
8 in/8 out |
8 in/8 out |
8 in/8 out |
|
|
|
|
|
|
Channel to Channel Isolation |
Yes, outputs |
Yes |
Yes |
|
|
|
|
|
|
Load Current per Point |
2..0 A for 5-265 VAC, 2..0 A for 5-30 VDC, |
10 mA min, 0..5 A max.., 5 A for 1 cycle |
2..0 A |
|
0..2 A for 31-125 VDC |
(20 ms) max.. inrush |
|
||
|
|
|||
|
|
|
|
|
Input and Output Response |
1 AC cycle minimum and 2 AC cycle |
1 cycle/2 cycle and |
1 cycle/2 cycle and |
|
TimeOn/Off(ms) |
(Hz dependent) maximum and 10..0 OFF |
<1/2 cycle/<1/2 cycle |
10/10 |
|
|
|
|
|
|
Protection |
No internal fuses or snubbers |
Snubber and MOVs (each output) |
No internal fuses or snubbers |
|
|
|
|
|
|
On State Current |
4 mA minimum |
5 mA minimum |
5 mA minimum |
|
|
|
|
|
|
Off State Current |
1..5 mA maximum |
2..5 mA maximum |
2..5 mA maximum |
|
|
|
|
|
|
External Power Supply |
0-125 VDC, 5/24/125 VDC nominal; |
0-125 VDC, 5/24/125 VDC nominal; |
N/A |
|
0-265 VAC (47-63 Hz), 120/240 VAC nominal |
0-265 VAC (47-63 Hz), 120/240 VAC nominal |
|
||
|
|
|||
|
|
|
|
|
Input Impedance |
38..5 kOhms (reactive) at 60 Hz, typical; |
8..6 kOhms (reactive) at 60 Hz, typical; |
8..6 kOhms (reactive) at 60 Hz, typical; |
|
46..3 kOhms (reactive) at 50 Hz, typical |
10..32 kOhms (reactive) at 50 Hz, typical |
10..32 kOhms (reactive) at 50 Hz, typical |
||
|
||||
|
|
|
|
|
|
10 mA per point minimum |
10 mA minimum per point, |
10 mA per point minimum; |
|
Load Current |
2..0 Amps for 5 to 265 VAC maximum (resistive) |
0..5 A maximum per point, 5..0 A for |
2..0 A for 5-265 VAC maximum (resistive); |
|
2..0 Amps for 5 to 30 VDC maximum (resistive) |
one cycle (20 ms) maximum inrush |
2..0 A for 5-30 VDC maximum (resistive); |
||
|
||||
|
0..2 Amp for 31 to 125 VDC maximum (resistive) |
|
0..2 A for 31-125 VDC maximum (resistive) |
|
|
|
|
|
|
5V Backplane Current |
300 maximum |
125 maximum |
300 maximum |
|
Consumption (mA) |
||||
|
|
|
||
|
|
|
|
|
|
One LED per point shows individual point |
One LED per point shows individual point |
One LED per point shows individual point |
|
LED Indicators |
on/off state (logic side); OK LED indicates |
on/off state (logic side); OK LED indicates |
on/off state (logic side); OK LED indicates |
|
|
backplane power is present |
backplane power is present |
backplane power is present |
|
|
|
|
|
|
|
110 mm (4..3 in) x 66..8 mm (2..63 in) x |
110 mm (4..3 in) x 66..8 mm (2..63 in) x |
110 mm (4..3 in) x 66..8 mm (2..63 in) x |
|
Dimensions (W x H x D) |
50 mm (1..956 in), not including the |
50 mm (1..956 in), not including the |
50 mm 1..956 in), not including the |
|
height of the carrier or the |
height of the carrier or the |
height of (the carrier or the |
||
|
||||
|
mating connectors |
mating connectors |
mating connectors |
|
|
|
|
|
www.geautomation.com |
Automation & Control Systems 1..125 |
VersaMax Control |
Process Automation Control Systems |
|
|
|
Discrete Mixed I/O Modules |
|
Discrete mixed modules provide maximum flexibility by combining inputs and outputs in a single, |
|
compact module.. Discrete input modules receive signals from input devices such as sensors, |
|
pushbuttons, and switches that can have two states: on or off, open or closed.. Discrete output modules |
|
send control signals to devices such as contactors, indicator lamps, and interposing relays that can also |
|
have two states.. Discrete mixed modules provide maximum flexibility by combining inputs and outputs in |
|
a single, compact module.. Modules require a carrier base (IC200CHSxxx).. |
|
IC200MDD850 |
IC200MDD851 |
|
|
|
|
VersaMax Discrete Mixed Modules |
VersaMax Discrete Mixed Modules |
Product Name |
240 VAC Input Isolated 4 points/Output |
5/12 VDC Input 16 points/Output |
|
Relay 2..0 A Isolated 8 points |
12/24 VDC 16 points |
|
|
|
Lifecycle Status |
Active |
Active |
|
|
|
Input Voltage |
0-264 VAC (47-63 Hz), 240 VAC nominal |
0 to 15 VDC, +5/12 VDC nominal |
|
|
|
|
0-125 VDC, 5/24/125 VDC nominal; |
+10..2 to +30 VDC, +12/24 VDC nominal |
Output Voltage |
0-265 VAC (47-63 Hz), |
|
|
120/240 VAC nominal |
|
|
|
|
Number of Points |
8 out/4 in |
16 out/16 in |
|
|
|
Channel to Channel Isolation |
Yes |
No |
|
|
|
Load Current per Point |
2..0 A |
0..5 Amps at 30 VDC maximum (resistive) |
|
2..0 Amps maximum for 100ms inrush |
|
|
|
|
|
|
|
Input and Output Response |
1 cycle/2 cycle |
0..25ms maximum/0..2ms ON |
TimeOn/Off(ms) |
and 10/10 |
and 1..0ms OFF maximum |
|
|
|
Protection |
No internal fuses or snubbers |
No internal fuses or snubbers |
|
|
|
On State Current |
4 mA minimum |
1..45 mA minimum |
|
|
|
Off State Current |
1..5 mA maximum |
0 to 0..7 mA maximum |
|
|
|
External Power Supply |
N/A |
+10..2 to +30 VDC, +12/24 VDC nominal |
Input Impedance
Load Current
38..5 kOhms (reactive) at 60 Hz, typical; |
2..4kOhms typical @ 12 VDC |
46..3 kOhms (reactive) at 50 Hz, typical |
|
10 mA per point minimum; |
0..5 Amps at 30 VDC maximum (resistive); |
2..0 A for 5-265 VAC maximum (resistive); |
2..0 Amps maximum for 100ms inrush |
2..0 A for 5-30 VDC maximum (resistive); |
|
0..2 A for 31-125 VDC maximum (resistive) |
|
5V Backplane Current |
260 maximum |
115 maximum |
|
Consumption (mA) |
|||
|
|
||
|
|
|
|
|
One LED per point shows individual point |
One LED per point shows individual point |
|
LED Indicators |
on/off state logic side); OK LED indicates |
on/off state (logic side); OK LED indicates |
|
|
backplane power is present |
backplane power is present |
|
|
|
|
|
|
110 mm (4..3 in) x 66..8 mm (2..63 in) x |
110 mm (4..3 in) x 66..8 mm (2..63 in) x |
|
Dimensions (W x H x D) |
50 mm (1..956 in), not including the |
50 mm (1..956 in), not including the |
|
height of the carrier or the |
height of the carrier or the |
||
|
|||
|
mating connectors |
mating connectors |
|
|
|
|
1..126 Automation & Control Systems |
www.geautomation.com |
Process Automation Control Systems |
VersaMax Control |
|
|
Discrete Input Modules
Discrete input modules receive signals from input devices such as sensors, pushbuttons, and switches that can have two states: on or off, open or closed.. Modules require a carrier base (IC200CHSxxx)..
|
IC200MDL140 |
IC200MDL141 |
IC200MDL143 |
|
|
|
|
|
|
|
VersaMax Discrete Input |
VersaMax Discrete Input |
VersaMax Discrete Input |
|
Product Name |
Module 120 VAC, |
Module 240 VAC, |
Module 120 VAC Isolated, |
|
|
8 points |
8 points |
8 points |
|
|
|
|
|
|
Lifecycle Status |
Active |
Active |
Active |
|
|
|
|
|
|
Input Voltage |
0-132 VAC |
0-264 VAC |
0-132 VAC |
|
|
|
|
|
|
Number of Points |
8 |
8 |
8 |
|
|
|
|
|
|
Channel to Channel Isolation |
No |
No |
Yes |
|
|
|
|
|
|
Input and Output Response |
1 cycle/2 cycles |
1 cycle/2 cycles |
1 cycle/2 cycles |
|
TimeOn/Off (ms) |
||||
|
|
|
||
|
|
|
|
|
Points per Common |
1 group of 8 |
1 group of 8 |
8 groups of 1 |
|
|
|
|
|
|
On State Current |
5 mA minimum |
7 mA minimum |
5 mA minimum |
|
|
|
|
|
|
Off State Current |
2..5 mA maximum |
1..5 mA maximum |
2..5 mA maximum |
|
|
|
|
|
|
Input Impedance |
8..6 kOhms (reactive) at 60 Hz, typical; |
38..5 kOhms (reactive) at 60 Hz, typical; |
8..6 kOhms (reactive) at 60 Hz, typical; |
|
10..32 kOhms (reactive) at 50 Hz, typical |
46..3 kOhms (reactive) at 50 Hz, typical |
10..32 kOhms (reactive) at 50 Hz, typical |
||
|
||||
|
|
|
|
|
5V Backplane Current |
55 maximum |
55 maximum |
50 maximum |
|
Consumption (mA) |
||||
|
|
|
||
|
|
|
|
|
|
One LED per point shows |
One LED per point shows |
One LED per point shows |
|
LED Indicators |
individual point ON/OFF status.. |
individual point ON/OFF status.. |
individual point ON/OFF status.. |
|
OK LED indicates backplane |
OK LED indicates backplane |
OK LED indicates backplane |
||
|
||||
|
power is present |
power is present |
power is present |
|
|
|
|
|
|
|
110 mm (4..3 in) x 66..8 mm (2..63 in) x |
110 mm (4..3 in) x 66..8 mm (2..63 in) x |
110 mm (4..3 in) x 66..8 mm (2..63 in) x |
|
Dimensions (W x H x D) |
50 mm (1..956 in), not including the |
50 mm (1..956 in), not including the |
50 mm (1..956 in), not including the |
|
height of the carrier or the |
height of the carrier or the |
height of the carrier or the |
||
|
||||
|
mating connectors |
mating connectors |
mating connectors |
|
|
|
|
|
www.geautomation.com |
Automation & Control Systems 1..127 |
VersaMax Control |
Process Automation Control Systems |
|
|
Discrete Input Modules
Discrete input modules receive signals from input devices such as sensors, pushbuttons, and switches that can have two states: on or off, open or closed.. Modules require a carrier base (IC200CHSxxx)..
|
IC200MDL144 |
IC200MDL240 |
IC200MDL241 |
|
|
|
|
|
|
|
VersaMax Discrete Input |
VersaMax Discrete Input |
VersaMax Discrete Input |
|
Product Name |
Module 240 VAC Isolated, |
Module, 120 VAC Positive Logic, |
Module, 240 VAC Positive Logic, |
|
|
4 points |
16 points |
16 points |
|
|
|
|
|
|
Lifecycle Status |
Active |
Active |
Active |
|
|
|
|
|
|
Input Voltage |
0-264 VAC |
0-132 VAC |
0-264 VAC |
|
|
|
|
|
|
Number of Points |
4 |
16 |
16 |
|
|
|
|
|
|
Channel to Channel Isolation |
Yes |
No |
No |
|
|
|
|
|
|
Input and Output Response |
1 cycle/2 cycles |
1 cycle/2 cycles |
1 cycle/2 cycles |
|
TimeOn/Off (ms) |
||||
|
|
|
||
|
|
|
|
|
Points per Common |
4 groups of 1 |
2 groups of 8 |
2 groups of 8 |
|
|
|
|
|
|
On State Current |
7 mA minimum |
5 mA minimum |
4 mA minimum |
|
|
|
|
|
|
Off State Current |
3 mA maximum |
2..5 mA maximum |
1..5 mA maximum |
|
|
|
|
|
|
Input Impedance |
38..5 kOhms (reactive) at 60 Hz, typical; |
8..6 kOhms (reactive) at 60 Hz, typical; |
38..5 kOhms (reactive) at 60 Hz, typical; |
|
46..3 kOhms (reactive) at 50 Hz, typical |
10..32 kOhms (reactive) at 50 Hz, typical |
46..3 kOhms (reactive) at 50 Hz, typical |
||
|
||||
|
|
|
|
|
5V Backplane Current |
30 maximum |
110 maximum |
110 maximum |
|
Consumption (mA) |
||||
|
|
|
||
|
|
|
|
|
|
One LED per point shows |
One LED per point shows |
One LED per point shows |
|
LED Indicators |
individual point ON/OFF status.. |
individual point ON/OFF status.. |
individual point ON/OFF status.. |
|
OK LED indicates backplane |
OK LED indicates backplane |
OK LED indicates backplane |
||
|
||||
|
power is present |
power is present |
power is present |
|
|
|
|
|
|
|
110 mm (4..3 in) x 66..8 mm (2..63 in) x |
110 mm (4..3 in) x 66..8 mm (2..63 in) x |
110 mm (4..3 in) x 66..8 mm (2..63 in) x |
|
Dimensions (W x H x D) |
50 mm (1..956 in), not including the |
50 mm (1..956 in), not including the |
50 mm (1..956 in), not including the |
|
height of the carrier or the |
height of the carrier or the |
height of the carrier or the |
||
|
||||
|
mating connectors |
mating connectors |
mating connectors |
|
|
|
|
|
1..128 Automation & Control Systems |
www.geautomation.com |