GE Logix 740C-ET, Logix 760C-ET Quick Start Manual


Autotrol
Series 255 Valve
Series 263 Valve
Series 268 Valve
740C-ET & 760C-ET
Controllers
Quick Start Manual
LOGIX™ SERIES INSTALLER QUICK-START SHEET
LOGIX SERIES CONTROLLERS
740 Controller - Electronic time clock control capable of doing 7-day (day of week) regeneration, or up to a 99 interval day regeneration. This control will operate both in a conditioner (softener) or 3-cycle filter mode with the same controller.
760 Controller - Electronic metered-demand (volumetric) controller which regenerates based on the water usag e of the installation site. A calendar override is a standard feature on this controller.
The Logix Series will operate on both the 255 and Performa valve body series.
LCD Display
SU MO TU WE TH FR SA DAYS
Time & Day
Regen Time & Day
Salt
x2
Capacity
P
Hardness
H
C
DOWN Button
SET Button
INITIAL POWER-UP
Initial Power Up - (CAMSHAFT proceeds to HOME position)
At initial power-up, the camshaft will need to rotate to the HOME (in service) position.
Camshaft may take 1-2 minutes to return to home position.
Err 3 will be displayed until the camshaft returns to home.
If more than 2 minutes elapses, verify that the motor is turning the camshaft. If it is not turning, see the troubleshooting section in Dealer Installation and Service Manual.
Time & Day
Regen Time & Day
Capacity
Hardness
SU MO TU WE TH FR SA DAYS
Salt
INITIAL START-UP STEP-BY-STEP INSTRUCTIONS
PM
MIN
LBS
KG
x100
UP Button
Manual Regeneration
Time & Day
Regen Time & Day
Salt
Capacity
Hardness
Time & Day
Regen Time & Day
Capacity
Hardness
SU MO TU WE TH FR SA DAYS
SU MO TU WE TH FR SA DAYS
Salt
Step 1: Program System Size
This step may have been performed by your system’s OEM manufacturer. In this case, proceed to step 2
• Input tank diameter size in inch (7-8-9-10-11-12-13-14-16).
• Use UP and DOWN buttons to scroll diameter choices.
• "11" value corresponds to 10x44 and 10x54 tank sizes.
To choose a 3-cycle filter operation - press DOWN until an "F" is displayed.
Press SET to accept the system size you’ve selected.
If incorrect setting is programmed, see "Resetting the Control" section below.
.
1
SU MO TU WE TH FR SA DAYS
Time & Day
Capacity
Hardness
Step 2: Program Time of Day
While "12:00" is blinking, set the correct time of day.
Use the UP and DOWN buttons to scroll to the correct time of day.
"PM" is indicated, "AM" is not indicated.
Press SET to accept the correct time of day and advance to the next parameter.
Step 3: Set Day of Week
Time & Day
Regen Time & Day
Capacity
Hardness
Time & Day
Regen Time & Day
Salt
Capacity
Hardness
Time & Day
Regen Time & Day
Salt
Capacity
Hardness
SU MO TU WE THFRSA DAYS
Salt
SU MO TU WE TH FR SA DAYS
SU MO TU WE TH FR SA DAYS
Press SET to make the arrow under SU flash.
Use the UP and DOWN butt ons to advance th e arrow until it is under the co rrect da y of week.
Press SET to accept and advance to the next parameter.
After steps 1-3, the controll er will operate most syste ms. Proce ed to step 4 if further adjustments to your system’s programming is needed.
To exit the programming state, wait 30 seconds and the controller will automatically put you into the normal operating mode.
Step 4: Set Regen Time
2:00 (AM) is the default time of regeneration. To accept this time, press the DOWN button to move to step 5.
To change the regen time, press SET - causing 2: 00 to flash.
Use the UP and DOWN buttons to advance to the desired regen time.
Press SET to accept the time and advance to the next parameter.
Step 5: Set Days to Regenerate (740 Time-clock Control Only)
• If using 760 control - proceed to step 5b
Set number of da ys between time-clock regeneration (regen fr equency).
Default time is 3 days.
Days can be adjusted from 1/2 (.5) to 99 days.
To change, press SET to make the "3" flash.
Use the UP and DOWN but tons to change to the number of days desired.
Press SET to accept the regen frequency, and advance to the next cycle.
To use the 7-day timer option - see full Dealer Installation Manual.
Time & Day
Regen Time & Day
Salt
Capacity
Hardness
2
SU MO TU WE TH FR SA DAYS
Step 5a: Regeneration in a specific day of week (7 days timer)
• To set the regeneration in specific days, set "0" in calendar override.
• Done this, the arrow in the left side of the display indicates hour/ regeneration day.
• Press SET button and a flashing cursor will be displayed at the top under Sunday.
• The day of the week can be adjusted when the cursor at desired position.
• To select or delete the day of week, the triangular cursor has to be under this day.
• If the cursor is in position but fixed, press SET button to make it flashing.
• To move the cursor when is fixed use UP and DOWN buttons, press SET if is flashing.
Loading...