As an EnErgy Star® partner, GE has
determined that this product meets
the EnErgy Star® guidelines for
energy efficiency.
Write the model and serial numbers here:
Model # __________________________
Serial # __________________________
Find these numbers on a label on the
side of the air conditioner.
Air Conditioners
de aire
Manual del propietario
y instrucciones de
instalación
La sección en español empieza en la página 33
In Canada, contact us at:
www.GEAppliances.ca
49-7642 03-10 GE
IMPORTANT SAFETY INFORMATION.
READ ALL INSTRUCTIONS BEFORE USING.
WARNING!
For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock
or personal injury.
Safety InstructionsOperating Instructions
SAFETY PRECAUTIONS
Care and Cleaning
n Use this appliance only for its intended
purpose as described in this Owner’s
Manual.
n This air conditioner must be properly
installed in accordance with the Installation
Instructions before it is used.
n Never unplug your air conditioner by pulling
on the power cord. Always grip plug firmly
and pull straight out from the receptacle.
n Replace immediately all electric service
cords that have become frayed or otherwise
damaged. A damaged power supply cord
must be replaced with a new power supply
cord obtained from the manufacturer and
not repaired. Do not use a cord that shows
cracks or abrasion damage along its length
or at either the plug or connector end.
n Turn the unit OFF and unplug your air
conditioner before cleaning.
n GE does not support any servicing of the
air conditioner. We strongly recommend
that you do not attempt to service the air
conditioner yourself.
n For your safety…do not store or use
combustible materials, gasoline or other
flammable vapors or liquids in the vicinity
of this or any other appliance.
n All air conditioners contain refrigerants,
which under federal law must be removed
prior to product disposal. If you are getting
rid of an old product with refrigerants, check
with the company handling disposal about
what to do.
n If the receptacle does not match the plug,
the receptacle must be changed out by a
qualified electrician.
n These R410A air conditioning systems
require contractors and technicians to
use tools, equipment and safety standards
approved for use with this refrigerant.
DO NOT use equipment certified for
R22 refrigerant only.
Installation InstructionsTroubleshooting TipsConsumer Support
2
HOW TO CONNECT ELECTRICITY
Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord.
For personal safety, this appliance must be
properly grounded.
DO NOT use an adapter plug with this
appliance.
The power cord of this appliance is equipped
with a 3-prong (grounding) plug which mates
with a standard 3-prong (grounding) wall outlet
to minimize the possibility of electric
shock hazard from this appliance.
Power cord includes a current interrupter device.
A test and reset button is provided on the plug
case. The device should be tested on a periodic
basis by first pressing the TEST button and
then the RESET button while plugged into the
outlet. If the TEST button does not trip or if the
RESET button will not stay engaged, discontinue
use of the air conditioner and contact a qualified
service technician.
Have the wall outlet and circuit checked by
a qualified electrician to make sure the outlet
is properly grounded.
Where a 2-prong wall outlet is encountered,
it is your personal responsibility and obligation to
have it replaced with a properly grounded
3-prong wall outlet.
The air conditioner should always be plugged
into its own individual electrical outlet which has
a voltage rating that matches the rating plate.
This provides the best performance and also
prevents overloading house wiring circuits which
could cause a fire hazard from overheated wires.
See the Installation Instructions, Electrical
Requirements section for specific electrical
connection requirements.
WARNING!
USE OF EXTENSION CORDS—115-Volt models only
GEAppliances.com
Because of potential safety hazards under certain
conditions, we strongly recommend against the
use of an extension cord.
However, if you must use an extension cord,
it is absolutely necessary that it be a UL-listed,
14-gauge, 3-wire grounding-type appliance
extension cord having a grounding-type plug
and outlet and that the electrical rating of the
cord be 15 amperes (minimum) and 125 volts.
CAUTION:
DO NOT use an extension cord with any of the
230/208 volt models.
READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY
SAVE THESE INSTRUCTIONS
Lights next to the touch pads on the air conditioner control panel indicate the selected settings.
Light indicates the unit
Safety InstructionsOperating Instructions
is in the temperature or
delay time Set mode.
Delay 1–24hr
Care and Cleaning
Installation InstructionsTroubleshooting TipsConsumer Support
(on some models)
NOTE: The display always shows the room
temperature except when setting the Set
temperature or the Delay timer.
Light indicates the
delay timer is set.
Air Conditioner Controls
Controls
Power Pad
Turns air conditioner on and off. When turned
on, the display will show the room temperature.
Display
Shows the room temperature or time remaining
on the Delay timer. Shows the Set temperature
while setting the temperature in Cool or Energy Saver modes. The Set light will turn on while
setting.
Temp Increase ▲ /Decrease ▼ Pads
Use to set temperature when in Cool or Energy
Saver mode. The Set light will turn on while
setting.
Delay Timer Increase▲ (+) /Decrease ▼(–)
Pads
Each touch of the Increase▲ / Decrease ▼
pads on the unit or the Increase + / Decrease –
pads on the remote control will set the delay
time when using the Delay 1–24hrtimer ().
The Set light will turn on while setting.
Fan Speed Pads
Use to set the fan speed to Low, Med, High
or Auto on the unit. NOTE: On the remote
control, use the fan speed Increase + /
Decrease –pads to set the fan speeds to Low,
Med or High. Use the Auto pad to turn Auto
fan on.
Delay timer
Decrease
Mode select
Fan speed
Decrease
Temperature
set Increase
and Decrease
FanFan
Remote Control
Mode Pad
Use to set the air conditioner to Cool, Energy
Saver or Fan Only mode.
Delay Pads
Delay ON—When the air conditioner is off, it can
be set to automatically come on in 1 to 24 hours
at its previous mode and fan settings.
Delay OFF—When the air conditioner is on,
it can be set to automatically turn off in 1 to
24 hours.
How to set:
Press the Delay 1–24hr pad on the unit or the
pad on the remote control. Each touch of the
Increase▲/ Decrease▼pads on the unit or
the Increase + / Decrease – pads on
the remote control will set the timer in
1-hour intervals. The Set light will turn on while
setting.
To review the remaining time on the Delay 1–24hr timer, press the Delay 1–24hr pad on the
unit or thepad on the remote control. Use
the Increase▲ / Decrease▼ pads on the unit
or the Increase + / Decrease – pads on the
remote control to set a new time if desired.
To cancel the timer, press the Delay 1–24hr pad
until the light on the Delay 1–24hr pad goes off.
Delay timer
Increase
Auto Fan on
Fan speed
Increase
Unit power
on/off
4
Do Not Operate in Freezing Outdoor Conditions
This cool-only air conditioner was not designed for
freezing outdoor conditions. It must not be used in
freezing outdoor conditions.
Remote Control
n To ensure proper operation, aim the remote
control at the signal receiver on the air
conditioner.
n The remote control signal has a range of
up to 20 feet.
Cool Mode
Use the Cool mode at Low, Med, High or Auto Fan
Speed for cooling. Use the Temperature Increase ▲
/ Decrease▼ pads to set the desired temperature
between 64°F and 86°F in 1°F increments.
An electronic thermostat is used to maintain the room
temperature. The compressor will cycle on
and off to keep the room at the set level of comfort.
Set the thermostat at a lower number and the indoor
air will become cooler. Set the thermostat at a higher
number and the indoor air will become warmer.
NOTE: If the air conditioner is off and is then turned on
while set to a Cool setting or if turned from a fan
setting to a Cool setting, it may take approximately
3 minutes for the compressor to start and cooling to
begin.
GEAppliances.com
n Make sure nothing is between the air conditioner
and the remote control that could block the
signal.
n Make sure batteries are fresh and installed
correctly as indicated on the remote control.
Cooling Descriptions
For Normal Cooling—Select the Cool mode and
High or Med fan with a middle set temperature.
For Maximum Cooling—Select the Cool mode and High fan with a lower set temperature.
For Quieter and Nighttime Cooling—Select the
Cool mode and Low fan with a middle set
temperature.
Operating Instructions Safety Instructions
Care and Cleaning
Energy Saver Mode
Controls the fan.
ON—The fan will cycle on and off with the
compressor. This results in wider variations of room
temperature and humidity. Normally used when the
room is unoccupied. NOTE: The fan may continue to
run for a short time after the compressor cycles off.
Fan Only Mode
Use the Fan Only Mode at Low, Med or High fan
speed to provide air circulation and filtering without
cooling. Since fan-only settings do not provide
cooling, a Set temperature cannot be entered. The
room temperature will appear
in the display.
Auto Fan Speed
Set to Auto fan speed for the fan speed to
automatically set to the speed needed to provide
optimum comfort settings with the set temperature.
If the room needs more cooling, the fan speed
will automatically increase. If the room needs less
cooling, the fan speed will automatically decrease.
OFF—The fan runs all the time, while the compressor
cycles on and off.
NOTE: Auto Fan Speed cannot be used when in the
Fan Only Mode.
NOTE: Auto Fan Speed cannot be used when in the
Fan Only Mode.
In the case of a power outage or interruption, the
unit will automatically restart in the settings last
used after the power is restored. If the Delay 1–24hr
feature was set, it will resume countdown. You may
need to set a new time if desired.
5
About the controls on the air conditioner
Additional important information.
Air Direction
Use the lever to adjust the air direction left and right
Safety InstructionsOperating Instructions
only.
Care and cleaning of the air conditioner.
Grille and Case
Turn the air conditioner off and remove the plug from
the wall outlet before cleaning.
Air Filter
The air filter behind the front grille should be checked
and cleaned at least every 30 days or
more often if necessary.
To clean, use water and a mild detergent. Do not use
bleach or abrasives.
Care and Cleaning
Installation InstructionsTroubleshooting TipsConsumer Support
To remove:
Open the inlet grille by pulling downward on the tabs
at the top upper corners of the inlet grille until the
grille is in a 45º position. Remove the filter.
Clean the filter with warm, soapy water. Rinse and let
the filter dry before replacing it. Do not clean the filter
in a dishwasher.
CAUTION: DO NOT operate the air
conditioner without a filter because dirt and lint will
clog it and reduce performance.
Outdoor Coils
The coils on the outdoor side of the air conditioner
should be checked regularly. If they are clogged with
dirt or soot, they may be professionally cleaned.
How to Insert the Batteries in the Remote Control
TabTab
Remove the battery cover by sliding it according
1
to the arrow direction.
Insert new batteries, making sure that the (+)
2
and (–) of battery are installed correctly.
Reattach the cover by sliding it back
3
into position.
6
NOTES:
n Use 2 “AAA” (1.5 volt) alkaline batteries. Do not
use rechargeable batteries.
n Remove the batteries from the remote control if
the system is not going to be used for a long time.
n Do not mix old and new batteries. Do not mix
alkaline, standard (carbon-zinc) or rechargeable
(ni-cad, ni-mh, etc) batteries.
Installation
Air Conditioner
Instructions
Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: GEAppliances.com
In Canada, call 1.800.561.3344 or visit www.GEAppliances.ca
BEFORE YOU BEGIN
Read these instructions completely
and carefully.
•
IMPORTANT — Save these instructions
for local inspector’s use.
•
IMPORTANT— Observe all governing
codes and ordinances.
• Note to Installer – Be sure to leave these
instructions with the Consumer.
• Note to Consumer – Keep these instructions for
future reference.
• Skill level – Installation of this appliance
requires basic mechanical skills.
• Completion time –
• We recommend that two people install
this product.
• Proper installation is the responsibility
of the installer.
• Product failure due to improper installation is not
covered under the Warranty.
• You MUST use all supplied parts and use proper
installation procedures as described in these
instructions when installing this air conditioner.
Approximately 1 hour
CAUTION:
Do not, under any circumstances, cut or remove the
third (ground) prong from the power cord.
Do not change the plug on the power cord of this air
conditioner.
Aluminum house wiring may present special
problems—consult a qualified electrician.
TOOLS YOU WILL NEED
Phillips head screwdriver
Flat-blade screwdriver
ELECTRICAL REQUIREMENTS
Some models require a 115/120-volt AC,
60-Hz grounded outlet protected with a
15-amp time-delay fuse or circuit breaker.
The 3-prong grounding plug minimizes the
possibility of electric shock hazard. If the wall outlet you
plan to use is only a 2-prong outlet,
it is your responsibility to have it replaced with
a properly grounded 3-prong wall outlet.
Some models require 230/208-volt AC,
protected with a time-delay fuse or circuit
breaker. These models should be installed on
their own single branch circuit for best
performance and to prevent overloading
house or apartment wiring circuits, which
could cause a possible fire hazard from
overheating wires.
Ruler or tape measurePencil
Level
Power cord includes a current interrupter
device. A test and reset button is provided on the
plug case. The device should be tested on a periodic
basis by first pressing the TEST button and then the
RESET button while plugged into the outlet. If the
TEST button does not trip or if the RESET button will not
stay engaged, discontinue use of the air conditioner
and contact a qualified service technician.
7
Scissors or knife
Installation Instructions
PARTS INCLUDED
(Appearance may vary)
Top mounting rail
Air
conditioner
Window
sash seal
Foam top window
gasket
Right
accordion
panel
Left
accordion
panel
Type A (4)Type B (6)
Top mounting rail
seal strip
Window locking
bracket (1)
8
Installation Instructions
WINDOW REQUIREMENTS
1
•These instructions are for a standard double-hung
window. You will need to modify them for other types
of windows.
•The air conditioner can be installed without the
accordion panels if needed to fit in a narrow
window. See the window opening dimensions.
•All supporting parts must be secured
to firm wood, masonry or metal.
•The electrical outlet must be within reach of the
power cord.
•Follow the dimensions in the table and illustration
for your model.
13.5”
21”- 38.1”
(With accordion panels)
3
ATTACH THE TOP MOUNTING
RAIL SEAL STRIP
(Some models may have the seal strip
already attached to the top mounting rail.
If applicable, skip this step.)
Remove the backing from the top mounting
rail seal strip and attach the seal strip to the
bottom of the top mounting rail, along the
front edge.
Top mounting rail
FRONT VIEW
Top mounting rail
Remove
backing
from seal
strip
STORM WINDOW REQUIREMENTS
2
A storm window frame will not allow the air
conditioner to tilt toward the outside, and will keep it
from draining properly.
To adjust for this, attach a piece of wood to the sill.
WOOD PIECES
WIDTH: 2”
LENGTH: Long enough to fit inside the window
frame.
THICKNESS: To determine the thickness, place a
piece of wood on the sill to make it 1/2” higher than
the top of the storm window frame or the vinyl
frame.
Attach securely with nails or screws provided by the
installer.
1/2” higher
than vinyl frame
(on some windows)
1/2” higher
than storm
window
frame
Storm window
frame
Sill
Vinyl frame
Wood
Seal strip
4
PREPARE THE AIR CONDITIONER
Install the top mounting rail with 4 Type A
A
screws from the outside of the case.
Top mounting rail
Bottom mounting rail
Hold the accordion panel in one hand and
B
gently pull back to free the open end.
9
Installation Instructions
PREPARE THE AIR CONDITIONER (cont.)
4
Slide the free end of the accordion panel
C
into the side panel rails. Slide the panel
down. Be sure to leave enough space to
slip the top and bottom of the frame into
the rails on the cabinet.
NOTE: There is a right and a left accordion
panel. Be sure to use the proper panel for
each side.
Slide the left and right accordion panels
D
into the top and bottom mounting rails.
INSTALL THE AIR CONDITIONER
6
IN THE WINDOW
A
Place the air conditioner on the sill with
the bottom mounting rail against its back
edge. Center it and close the window
securely behind the top mounting rail.
It should be level or slightly tilted to the
outside. Use a level; about a 1/3 bubble
will be the correct case slant to the outside.
or
Type B screws
Extend the left and right accordion panels
B
to the vertical window sashes and attach,
through the holes in the panels, with 5 Type
B screws, as appropriate.
or
Top left
Bottom mounting rail
PREPARE THE WINDOW
5
Cut the window sash seal to the proper length.
Peel off the backing and attach the seal to the
underside of the window sash.
Top mounting rail
Top right
INSTALL SUPPORT BRACKET AND
7
FOAM TOP WINDOW GASKET
A
B
C
CAUTION:
To prevent broken glass or
damage to windows, on
vinyl or other similarly
constructed windows,
attach the window locking
bracket to the window
side jamb with one Type B
screw.
Cut the foam top window gasket to the window
width.
Stuff the foam
between the glass
and the window
to prevent air and
insects from getting
into the room.
NOTE: If the gasket supplied does not fit your
window, obtain appropriate material locally to
provide a proper installation seal.
Vinyl
Wood
10
Troubleshooting Tips.GEAppliances.com
Problem Possible Causes What To Do
Air conditioner The air conditioner •Make sure the air conditioner plug is pushed
does not start is unplugged. completely into the outlet.
The fuse is blown/circuit • Check the house fuse/circuit breaker box and replace
breaker is tripped. the fuse or reset the breaker.
Power failure. •The unit will automatically restart in the settings last
used after the power is restored.
•There is a protective time delay (approximately
3 minutes) to prevent tripping of the compressor
overload. For this reason, the unit may not start
normal cooling for 3 minutes after it is turned back on.
The current interrupter •Press the RESET button located on the power cord plug.
use of the air conditioner and contact a qualified
service technician.
device is tripped.
•If the RESET button will not stay engaged, discontinue
Operating Instructions Safety Instructions
Air conditioner does Airflow is restricted. • Make sure there are no curtains, blinds or furniture
not cool as it should blocking the front of the air conditioner.
The temp control may • Turn the temperature knob to a higher number.not be set correctly.
The air filter is dirty. • Clean the filter at least every 30 days.
See the Care and Cleaning section.
The room may have been hot. • When the air conditioner is first turned on, you need
to allow time for the room to cool down.
Cold air is escaping. • Check for open furnace registers and cold air returns.
Cooling coils have iced up. •See “Air conditioner freezing up” below.
Air conditioner Ice blocks the air flow • On models with control knobs, set the mode control at
freezing up and stops the air conditioner High Fan or High Cool with the Temp at 1 or 2.
Water drips outside Hot, humid weather. • This is normal.
Water drips indoors The air conditioner is not • For proper water disposal, make sure the air conditioner
tilted to the outside. slants slightly from the case front to the rear.
Water collects in Moisture removed from air • This is normal for a short period in areas with little
base pan and drains into base pan. humidity; normal for a longer period in very humid areas.
from cooling the room.
Care and Cleaning
Normal Operating Sounds
n You may hear a pinging noise caused by
water being picked up and thrown against the
condenser on rainy days or when the humidity
is high. This design feature helps remove
moisture and improve efficiency.
GE Air Conditioner—One-Year Limited Warranty. (For customers in the U.S.A.)
Staple your receipt here.
Proof of the original purchase date
is needed to make a warranty claim.
For The Period Of: We Will Replace:
One Year Replacement unit for any product which fails due to a defect in materials or workmanship.
From the date of the The replacement unit is warranted for the remainder of your product’s original one-year
original purchase warranty period.
In Order to Make a Warranty Claim:
n Properly pack your unit. We recommend using the
original carton and packing materials.
n Return the product to the retail location where it
was purchased.
n Include in the package a copy of the sales receipt or
other evidence of date of original purchase. Also print
your name and address and a description of the defect.
What Is Not Covered:
n Customer instruction. This owner’s manual provides
information regarding operating instructions and
user controls.
n Improper installation, delivery or maintenance. If you
have an installation problem, or if the air conditioner is
of improper cooling capacity, contact your dealer or
installer. You are responsible for providing adequate
electrical, plumbing and other connecting facilities.
n Failure of the product resulting from modifications to
the product or due to unreasonable use, including failure
to provide reasonable and necessary maintenance.
n Replacement of house fuses or resetting of circuit
breakers.
n Failure due to corrosion on models not corrosion-
protected.
n Damage to the product caused by improper power
supply voltage, accident, fire, floods or acts of God.
n Incidental or consequential damage caused by possible
defects with this air conditioner.
n Damage caused after delivery.
Operating Instructions Safety Instructions
Care and Cleaning
EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product replacement as provided in this Limited
Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are
limited to one year or the shortest period allowed by law.
This warranty is extended to the original purchaser and any succeeding owner for products purchased for home
use within the USA.
Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives
you specific legal rights, and you may also have other rights which vary from state to state. To know what your
legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.
Exclusion of implied warranties: Except where prohibited or restricted by law, there are no warranties, whether
express, oral or statutory which extend beyond the description on the face hereof, including specifically the
implied warranties of merchantability or fitness for a particular purpose.
Warrantor: General Electric Company. Louisville, KY 40225