Gardena Comfort 5000/5 LCD, Premium 6000/6 LCD Inox Operator's Manual

Premium 6000/6 LCD Inox Art. 1760Comfort 5000/5 LCD Art. 1759
MENU
EN Operator’s manual
Automatic Home & Garden Pump
3
1
Art. 1723 / Art. 1724
4
3
2
Art. 1752
5
7
6
8
O1
0
9
ß
A
MENU
q
r
O2
9
ß
A
0
a
M1
w
e
9
ß
A
MENU
q
M2
1
2
w
e
M3
t
r
MENU
q
S1
1
MENU
q
T1
z
T2
i
u
p
s
a
o
EN
1. SAFETY ..............................................4
2. INSTALLATION .........................................5
3. OPERATION ...........................................5
4. MENU SETTINGS .......................................6
5. MAINTENANCE ........................................7
6. STORAGE ............................................7
7. TROUBLESHOOTING ...................................7
8. TECHNICAL DATA ......................................8
9. ACCESSORIES ........................................9
10. SERVICE / WARRANTY ...................................9
Translation of the original instructions.
This appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Intended use:
The GARDENA Automatic Home & Garden Pump is intended for private use in the home and hobby garden and is not intended to be used for operatingirrigation equipment and systems in public gardens. It can be used for pumping rainwater, tap water and chlorinated water.
The product is not intended for continuous operation (e. g. industrial applications, continuous circulating operation).
DANGER! Corrosive, easily combustible, aggressive or explosive liquids (such as gasoline, petroleum or nitrothinner), saltwater and food intended for consumption must not be pumped.
Pressure amplification:
If you use the pump for pressure amplification, the maximum permissible internal pressure must not exceed 6 bar (on the pressure side). With this in mind, the pump pressure must be added to the pressure to be amplified.
– Example: pressure at the tap = 1.0 bar.
Maximum pressure of the Automatic Home & Garden Pump Comfort 5000/5 = 4.5 bar. Total pressure = 5.5 bar.
IMPORTANT! Read the operator’s manual carefully before use and keep for future reference.
Symbols on the product:
Read operator’s manual.
General safety warnings Electrical safety
DANGER! Electric shock! Risk of injury due to electric current. v The product must be supplied through a residual current device (RCD)
having a rated residual operating current not exceeding 30 mA.
DANGER! Electric shock! Risk of injury due to electric current. v Disconnect the product from the mains before you maintain or
replace parts. Thereby the disconnected socket must be in the visual range.
Safe operating practices
The water temperature should not exceed 35 °C. The pump must not be used when people are in the water. Leaking lubricants can contaminate the pumped liquid.
Circuit breakers
Dry-running protection: If no water is pumped (undercurrent) the pump switches off automatically.
1. SAFETY
Anti-lock protection: If the motor blocks (overcurrent), the pump switches off automatically.
Additional safety warnings Electrical safety
DANGER! Cardiac arrest!
This product makes an electromagnetic field while it operates. This field may under some conditions interfere with active or passive medical implants. To decrease the risk of conditions that can possibly injure or kill, we recommend persons with medical implants to speak with their physician and the medical implant manufacturer before you operate the product.
DANGER! Electric shock!
The product must not be operated if there are people in the swimming pool or garden pond.
v Make sure that the electrical plug and socket connections are fitted in
an area which cannot be flooded.
v Protect the power plug from moisture.
Connecting cable
DANGER! Electric shock!
With a cut off mains plug, moisture can get into electrical parts via the mains cable and cause a short circuit.
v Do not cut the mains plug off (e. g. to feed through a wall).
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified per­sons in order to avoid a hazard.
According to DIN VDE (German Electrical Engineers’ Association) 0620, mains power cables and extension cables must not have a smaller cross-section than the rubber-sheathed cables of the designation H07RN-F.
The cable length must be at least 10 m. Data indicated on the type plate must match technical data of the mains supply. Disconnect the product from the mains when it is not in use. Protect plug and power cable from heat, oil and sharp edges. Do not use the power cable to carry or to unplug the pump. As an additional safety device an approved safety switch can be used. v Please ask your electrician for his advice. Only use extension cables with earth connectors for operating this pump. A damaged pump must not be used. Before operating the pump look and see if there is any damage to the pump
(especially to the power cable and plug). v In case of damage, please have the pump checked by our GARDENA
Service Centre.
Personal safety
DANGER! Risk of suffocation!
Small parts can be easily swallowed. There is also a risk that the poly­bagcan suffocate toddlers. Keep toddlers away when you assemble the product.
DANGER! Risk of injury due to hot water!
If the electronic control is defective or if the water supply on the intake side of the pump fails, any water remaining in the pump may heat up, generating a risk of injuries caused by hot water on leakage.
v Disconnect the pump from the mains, let the water cool (approx.
10 – 15 min.) and secure the water supply on the intake side before putting into operation again.
Do not use the product while you are tired or under the influence of drugs, alco­hol or medication. A moment of inattention while you operate the product may result in serious personal injury.
When connecting the pump to the water supply system, the country-specific sanitary regulations must be observed to prevent water not of drinking water quality being drawn back in.
When water flows through the pump it is no drinking water anymore. When using the product, cover hair and do not wear scarves and other loose
items of clothing. Make sure that no children or unauthorised persons are within reach of the pump
and the pumped medium without supervision. In order to avoid dry-running of the pump, take care that the end of the suction
hose is always submerged into the water. v Before each operation, fill the pump with liquid to be pumped (approx. 2 to 3 l). The pump must be located on solid, even ground, protected from flooding.
Take care that the pump cannot fall into water. Very fine sand can pass through the integrated filter (mesh size 0.45 mm)
and cause accelerated wear in the hydraulic parts.
4
v For sandy water, you should additionally use the GARDENA Pump
Preliminary Filter, art. 1730 (mesh size 0.1 mm).
The temperature of the pumped liquid must be between 2 °C to 35 °C. Only stow the product in temperatures between 2 °C to 70 °C.
2. INSTALLATION
DANGER! Electric shock!
Risk of injury due to electric current.
v Disconnect the product from the mains before you install the
product.
Installation location [ Fig. I1 ]:
The pump must be installed in a location with sufficient venti­lation in the area of the ventilation slots. It must be at a distance of at least 5 cm from the walls. No dirt contamination (e. g. sand or soil) may be sucked in through the ventilation slots.
Set up the pump so that it is prevented from slipping and that an appro­priately large collecting vessel for draining the pump or the system can be placed under the drain screw
1
.
Install the pump at a safe distance (min. 2 m) from the pumping medium.
If possible, install the pump higher than the surface of the water to be pumped. If this is not possible, install a vacuum-resistant shut-off device between the pump and the suction hose to allow the integrated filter to be cleaned.
If the system is permanently installed, appropriate shut-off devices must be installed on the input and output sides. Important for maintenance and cleaning work on the pump or for shutdown, for example.
Connections:
CAUTION!
The GARDENA connection pieces on the intake and deli­very sides may only be tightened by hand. Check whether the seal ring is present and undamaged before screwing the suction hose onto the suction inlet. When using metal connections, damage could occur on the connection thread due to inapprop­riate assembly. Therefore, screw on the connection fittings with the upmost care. Use sealing tape only for sealing metallic connection fittings.
Suction side:
Do not use modular water hose components on the suction side! A vacuum-tight suction hose must be used e.g.:
– GARDENA Suction Hose Art. 1411 / 1418
– GARDENA Bore Hole Suction Hose Art. 1729
– GARDENA Suction Hose sold by the metre with
GARDENA Hose Clamp Art. 7192 / 7191.
If very fine dirt is present, we recommend the use of a GARDENA pump preliminary filter Art. 1730 / 1731 in addition to the integrated filter.
To reduce the pump repriming time, we recommend to use a suction hose with backflow preventer, which prevents the suction hose emptying automatically when the Pump is switched off.
Important for fixed installation:
For greater suction heads, use a suction hose with a small diameter (3/4").
Pressure side:
A pressure-resistant hose must be used on the pressure side, e. g.:
– GARDENA Garden Hose (3/4") Art. 18113 with
GARDENA Connection Set Art. 1752.
Important for fixed installation:
If the product is permanently installed in an enclosed space, only flexible hoses (e.g. reinforced hoses) may be used for connecting the service water supply, rather than rigid piping. Flexible hoses will reduce the noise level and prevent damage caused by pressure surges. Install fixed pipes at an upward gradient on the first 2 m only. To avoid damage to the thread, ensure careful and accurate installation when using metal connections.
To connect the suction hose [ Fig. I2 ]:
1. Screw the suction hose fitting
3
onto the suction inlet 4 and tighten
it by hand.
2. Slide the suction hose 2 onto the suction hose fitting 3 and secure
it e.g. with a GARDENA Hose Clamp Art. 7192 / 7191.
3. For suction head exceeding 4 m secure the suction hose (e. g. by fastening it to a wooden post).
The pump and the suction hose are relieved from the weight of the water.
To connect the pressure hose [ Fig. I3 ]:
The pressure hose can be connected either to the delivery side
33.3 mm (G1)-thread of the 120° swivelling connection
5
and / or
of the horizontal connection 8.
1. Screw the tap connector
7
onto the pressure outlet 5 / 8 and tighten
it by hand.
2. Connect the pressure hose with hose connector
6
onto the tap
connector 7.
3. OPERATION
DANGER! Electric shock!
Risk of injury due to electric current.
v Disconnect the product from the mains before you fill the
pump.
To start the Automatic Home & Garden Pump [ Fig. O1 / O2 ]:
NOTE: The specified maximum self-priming level (see 8. TECHNI­CAL DATA) is reached only when the pump is full and the pressu­re hose is held up high directly upstream of the pressure output during the first self-priming phase. This ensures that the pumped medium cannot leak from the pressure hose. When using a full suction hose with a check valve, it is not necessary to hold up the pressure hose.
1. Unscrew the lid
9
of the filter chamber with the spanner > provided.
2. Slowly fill in the liquid to be pumped via the filler connection
0
up to the overflow (approx. 2 to 3 l) until the water level no longer drops under the suction side inlet or the water flows out at the horizontal connector.
3. With fixed installation: Unscrew the cover
r
and fill with liquid until it
flows towards the horizontal connector.
4. Empty any water remaining in the delivery hose so that the air can escape during filling and priming.
5. Open any shut-off devices in the delivery line (watering accessories, tap, etc.) so that air can escape before the priming procedure begins.
6. With fixed installation: If the delivery line cannot be emptied due to fixed installation, unscrew the cover
r
. Considerable amounts of liquid may escape. Please keep a sufficiently large receptacle at hand for collection.
7. Tighten the lid
9
of the filter chamber up to the stopper <.
8. Without fixed installation: Lift up the delivery hose just behind the
pressure outlet.
9. Plug the power plug of the connecting cable into a mains socket.
10. Push the on / off switch
q
to position I.
The on / off switch lights up.
During initial operation, the display language must be selected after the pump is switched on.
11.
Select the desired display language
with the left or right button and confirm with the centre button .
The display shows “Start pump now?”.
12.
Push the left button .
The pump starts after approx. 2 seconds. The display shows “Suction in progress” and the GARDENA sun is rotating in the display during the suction process.
The suction process can take up
to 6 min. If no water is pumped afterwards, the Automatic Home & Garden Pump switches off and the display shows „ERROR 2“ (see 7. TROUBLESHOOTING“).
5
Loading...
+ 7 hidden pages