With cover/adjustment strip
14 ¹⁵⁄₁₆"
(
380
)
⅛"
(3)
14 ¹⁵⁄₁₆"
(
380
)
⅛"
(3)
14 ¹⁵⁄₁₆"
(
380
)
45
⅛"
(
1146
)
- ⁶⁄₈" -
(20)
44 ⁵⁄₁₆"
±¹⁄₁₆"
(
1126
±2
)
14 ¹⁵⁄₁₆"
(
380
)
⅛"
(3)
35 ¾"
(
808
)
50 ¹³⁄₁₆"
±¹⁄₁₆"
(
1291
)
- ⁶⁄₈" -
(20)
50 ¹⁄₁₆"
±¹⁄₁₆"
(
1271
±2
)
Series
Cut-out dimensions for Vario 400 series combinations.
The drawings below and on the following page show the cut-out dimensions for typical Vario 400 series combinations for a surface-mount
installation. The installer can find suitable cut-out dimensions for combinations most frequently used by referring to the previous pages,
the drawings below, and on the next page. The combinations listed here are only examples.
Depending on the type of installation (with or without cover/adjustment strip), the following connection strips must be used:
VA 420 010 for a surface-mount installation without appliance cover/adjustment strip.
VA 420 011 for a surface-mount installation with appliance cover/adjustment strip.
When installing with the VA 440 appliance cover or VA 450 adjustment strip, additional space for the cut-out depth needs to be considered.
Combination examples without VL 414 downdraft unit:
±¹⁄₁₆"
14 ³⁄₁₆"
14 ¹⁵⁄₁₆"
14 ¹⁵⁄₁₆"
14 ¹⁵⁄₁₆"
44 ⁵⁄₁₆"
14 ¹⁵⁄₁₆" 14 ¹⁵⁄₁₆"
⅛" ⅛"
±¹⁄₁₆"
50 ¹⁄₁₆"
35 ¾"
⅛"
19� ⅜"
±¹⁄₁₆"
⁹⁄₁₆"
⁹⁄₁₆"
20� ½"
20� ¼"
±¹⁄₁₆"
³⁄₁₆"
21� ¹⁄₁₆"
⁹⁄₁₆"
78 Vario cooktops
Numbers indicated
inside parenthesis ( ) = mm
Combination examples with VL 414 downdraft unit:
With cover/adjustment strip
14 ¹⁵⁄₁₆"
(
380
)
⅛"
(3)
4 ⁵⁄₁₆"
(
110
)
⅛"
(3)
14 ¹⁵⁄₁₆"
(
380
)
⅛"
(3)
4 ⁵⁄₁₆"
(
110
)
⅛"
(3)
14 ¹⁵⁄₁₆"
(
380
)
54
"
(
1372
)
- ⁶⁄₈" -
(20)
53 ¼"
±¹⁄₁₆"
(
1352
±2
)
(3)⅛"(3)⅛"(3)⅛"(3)⅛"(3)⅛"(3)
14 ¹⁵⁄₁₆"
(
380
)
⅛"
(3)
4 ⁵⁄₁₆"
(
110
)
⅛"
(3)
14 ¹⁵⁄₁₆"
(
380
)
⅛"
(3)
4 ⁵⁄₁₆"
(
110
)
⅛"
(3)
14 ¹⁵⁄₁₆"
(
380
)
⅛"
(3)
4 ⁵⁄₁₆"
(
110
)
⅛"
(3)
14 ¹⁵⁄₁₆"
(
380
)
73 ⁹⁄₁₆"
(
1868
)
- ⁶⁄₈" -
(20)
72 ¾"
±¹⁄₁₆"
(
1848
±2
)
±¹⁄₁₆"
3 ⁹⁄₁₆"
14 ¹⁵⁄₁₆"
4 ⁵⁄₁₆"
53 ¼"
4 ⁵⁄₁₆" 4 ⁵⁄₁₆"
14 ¹⁵⁄₁₆"
±¹⁄₁₆"
72 ¾"
±¹⁄₁₆"
⅛"
14 ¹⁵⁄₁₆"
19� ⅜"
±¹⁄₁₆"
⁹⁄₁₆"
⁹⁄₁₆"
20� ½"
20� ¼"
±¹⁄₁₆"
³⁄₁₆"
21� ¹⁄₁₆"
⁹⁄₁₆"
4 ⁵⁄₁₆"
14 ¹⁵⁄₁₆"
14 ¹⁵⁄₁₆"
4 ⁵⁄₁₆"
14 ¹⁵⁄₁₆"
4 ⁵⁄₁₆"
14 ¹⁵⁄₁₆"
⅛"
Numbers indicated
inside parenthesis ( ) = mm
Vario cooktops 79
With cover/adjustment strip
14 ¹⁵⁄₁₆"
(
380
)
⅛"
(3)
14 ¹⁵⁄₁₆"
(
380
)
⅛"
(3)
14 ¹⁵⁄₁₆"
(
380
)
45
¹⁄₁₆"
(
1146
)
- ⁶⁄₈" -
(20)
44 ⁵⁄₁₆"
±¹⁄₁₆"
(
1126
±2
)
+ ⁶⁄₈"
+ (20
)
+ ¼"
+ (6
)
45 ⅜"
±¹⁄₁₆"
(
1152
±2
)
50 ¹⁄₁₆"
±¹⁄₁₆"
(
1271
±2
)
51 ¹⁄₁₆"
±¹⁄₁₆"
(
1297
±2
)
Cut-out dimensions for Vario 400 series combinations. Flush installation.
The drawings below and on the following page show the cut-out dimensions for typical Vario 400 series combinations for a flush-mount in-
stallation. The installer can find suitable cut-out dimensions for combinations most frequently used by referring to the previous pages and
the drawings below and on the next page. The combinations listed here are only examples.
Depending on the type of installation (with or without cover/adjustment strip), the following connection strips must be provided:
VA 420 000 for a flush installation without appliance cover/adjustment strip.
VA 420 001 for a flush installation with appliance cover/adjustment strip.
If installing with the VA 440 appliance cover or VA 450 adjustment strip, additional space for the cut-out depth needs to be considered.
Furthermore, you must ensure that there is an asymmetrical alignment in the cut-out depth.
Combination examples without VL 414 downdraft unit:
15 ¹³⁄₁₆"
±¹⁄₁₆"
14 ³⁄₁₆"
14 ¹⁵⁄₁₆"
14 ¹⁵⁄₁₆"
45 ¾"
44 ⁵⁄₁₆"
14 ¹⁵⁄₁₆"
51 ¹⁄₁₆"
50 ¹⁄₁₆"
±¹⁄₁₆"
±¹⁄₁₆"
±¹⁄₁₆"
14 ¹⁵⁄₁₆"
⅛"
19 ⅜"
±¹⁄₁₆"
¹¹⁄₁₆"
⁵⁄₁₆"
20 ½" 20 20 ¼" 21 21 ⁵⁄₁₆"
¹¹⁄₁₆"
¹¹⁄₁₆"
14 ¹⁵⁄₁₆"
80 Vario cooktops
35 ¾"
⅛"
Numbers indicated
inside parenthesis ( ) = mm