3
1. Important notes
1.1 For your safety
– Damaged appliances must not be operated.
– The appliance must only be connected by an
authorised specialist, paying attention to
the relevant regulations of the power supply
companies and the regional construction
regulations.
Also observe the assembly instructions!
– Connecting cables must not come into contact
with hot cooking surfaces.
– Do not operate the extractor hood without
inserted lamps.
– Never operate the appliance without a grease
filter.
– Hazardous or explosive substances and
vapours must not be extracted!
– The user is responsible for expert use and the
perfect condition of the appliance.
– Only ever operate the appliance under super-
vision.
– Caution! Over-greased filters are a fire risk!
Only ever deep-fry under the extractor under
constant supervision. Pay attention to cleaning
the grease filter on a regular basis.
– Fire risk! Do not flambé meals under the
extractor hood!
– Operation of the extractor hood above a hearth
for solid fuels (coal or wood etc.) is only partly
permitted.
– Gas appliances may only be used under the
extractor hood when pots and pans are placed
on them!
– When using more than 3 gas-operated rings
at the same time, please operate the extractor
hood at level 2 or higher. This prevents a buildup of heat in the appliance.
– Do not place any heavy objects on the appli-
ance; this will have a detrimental effect on
functioning.
– Do not clean the appliance with a steam
cleaning apparatus or with water pressure
because this poses a risk of short-circuits.
– Isolate the appliance from the mains during
every maintenance operation. To do this,
remove the mains plug or actuate the corresponding fuse.
If the mains plug is not accessible, the appliance
must be deenergised by means of the domestic
installation fuse.
– Repairs must be carried out by authorised
specialists, thus ensuring electrical safety.
– No warranty claims can be lodged in the
event of damage caused by failure to observe
these instructions.
– Adequate incoming air must be ensured if a
wood, coal, gas or oil heater or an open hearth is
operated in the same room as the one in which
the hood is installed.
– Safe operation is possible whenever the partial
vacuum in the place where the firing equip-
ment is installed does not exceed 4 Pa
(0.04 mbar). This can be achieved whenever
the air needed for combustion is able to enter
through openings that cannot be sealed, for
example in doors, windows, incoming/exhaust
air wall boxes or other technical means.
– If the appliance is to be operated only with the
window open (to ensure adequate incoming
air), you can use the window switch.
A switch (normally open) is fitted on the window.
On the appliance, this switch is connected to the
window switch terminal on the main electronics.
The appliance can now only be operated when
the window is open.
Important: the window switch must only be
connected by an authorised specialist.
Note: The light function works without restriction.
– After a power failure, the extactor will not go
on again automatically. You can recommence
operation by turning a knob or by pressing any
key.
Technical modifications reserved.