Preface
With your new extractor hood, working in the kitchen will be even more fun.
The appliance offers you a number of
advantages:
– A good extraction capacity with low noise
values,
– a large number of control functions,
– optimum illumination of the cooking surface by
a dimmable halogen light.
To ensure that you will be able to use this appli­ance in all its diversity, read through the operating and assembly instructions conscientiously before operating it for the first time. The instructions contain important notes on use, installation and maintenance of the appliance.
On the following page you will find important notes on safety and operation. These will serve to ensure your personal safety and the lasting value of your appliance.
You will find notes on Page 4 that you ought to observe before operating the appliance for the first time.
The chapters entitled “Features” and “Operation” will tell you all the things your extractor hood is capable of doing and how the appliance is operated.
Tips and hints in the chapter entitled “Cleaning and care” will make sure that your appliance will stay operable and beautiful for a long time.
And now we wish you lots of fun with your new extractor hood.
Fig. 1
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a.) Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the manufacturer.
b.) Before servicing or cleaning unit, switch power
off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
CAUTION:
FOR GENERAL VENTILATION USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS.
WARNING - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE.
a.) Never leave surface units unattended at high
settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
b.) Always turn hood ON when cooking at high heat
or when cooking flaming foods.
c.) Clean ventilating fans frequently. Grease should
not be allowed to accumulate on fan or filter.
d.) Use proper pan size. Always use cookware
appropriate for the size of the surface element.
WARNING - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:
a.) SMOTHER FLAMES with a close-fitting lid,
cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
b.) NEVER PICK UP A FLAMING PAN - You may be
burned.
c.) DO NOT USE WATER, including wet dishcloth or
towels - a violent steam explosion will result.
d.) Use an extinguisher ONLY if:
1. You know you have Class ABC extinguisher, and you already know how to operate it.
2. The fire is small and contained in the area where it started.
3. The fire department is being called.
4. You can fight the fire with your back to an exit.
Safety notes
3
Read And Save These Instructions.
1.1 For your safety
– Damaged appliances must not be operated. – The appliance must only be connected by an
authorised specialist, paying attention to the relevant regulations of the power supply companies and the regional construction regulations.
Also observe the assembly instructions!
– Connecting cables must not come into contact
with hot cooking surfaces.
– Do not operate the extractor hood without
inserted lamps.
– Never operate the appliance without a grease
filter.
– Hazardous or explosive substances and vapours
must not be extracted!
– The user is responsible for expert use and the
perfect condition of the appliance.
– Only ever operate the appliance under super-
vision.
Caution! Over-greased filters are a fire risk!
Only ever deep-fry under the extractor under constant supervision. Pay attention to cleaning the grease filter on a regular basis.
Fire risk! Do not flambé meals under the
extractor hood!
– Operation of the extractor hood above a hearth
for solid fuels (coal or wood etc.) is only partly permitted.
– Gas appliances may only be used under the
extractor hood when pots and pans are placed on them!
– When using more than 3 gas-operated rings at
the same time, please operate the extractor hood at level 2 or higher. This prevents a build­up of heat in the appliance.
– For safety reasons, do not place any heavy
objects on the top of the appliance.
– Do not clean the appliance with a steam
cleaning apparatus or with water pressure because this poses a risk of short-circuits.
– Isolate the appliance from the mains during
every maintenance operation. To do this, actuate the corresponding fuse.
– Repairs must be carried out by authorised
specialists, thus ensuring electrical safety.
– No warranty claims can be lodged in the event
of damage caused by failure to observe these instructions.
– Adequate incoming air must be ensured if a
wood, coal, gas or oil heater or an open hearth is operated in the same room as the one in which the hood is installed.
– Safe operation is possible whenever the partial
vacuum in the place where the firing equipment is installed does not exceed 4 Pa (0.04 mbar). This can be achieved whenever the air needed for combustion is able to enter through openings that cannot be sealed, for example in doors, windows, incoming/exhaust air wall boxes or other technical means.
– If the appliance is to be operated only with the
window open (to ensure adequate incoming air), you can use the window switch. A switch (normally open) is fitted on the window. On the appliance, this switch is connected to the window switch terminal on the main electronics. The appliance can now only be operated when the window is open. Important: The window switch must only be connected by an authorised specialist. Note: The light function works without restriction.
– After a power failure, the extactor will not go on
again automatically. You can recommence operation by turning a knob or by pressing any key.
Technical modifications reserved.
4
1. Important notes
1.2 Operating for the first time
Before operating the appliance for the first time, please pay attention to the following notes:
– The appliance must be installed and connected
by a specialist before it is operated for the first time.
– The rating plate for this appliance is included
with the instructions on a separate sheet. Store the rating plate in the same location as your operating and assembly instructions. You need the rating plate for possible damage and warranty cases.
– Conscientiously read through the operating and
assembly instructions before operating the appliance for the first time.
– Remove the packaging from the appliance and
dispose of it properly. Pay attention to the fact that there are accessories in the packaging. Keep packaging elements out of the reach of children!
– Thoroughly clean the appliance before using it
for the first time (see chapter entitled “Cleaning and care”).
– Before operating the appliance for the first time,
check that the mains connection is in proper working order.
1.3 About use
– The appliance is intended solely for use in the
household and must not be put to any other uses.
– In the event of malfunctions, first of all check the
household fuses. If the problem has nothing to do with the power supply, please contact your specialist dealer or your local Gaggenau after­sales service.
5
6
2. Features
1 Outgoing air duct
2 Control panel
3 Grease filter
4 Lighting
Installation accessories:
Stainless steel-design ventilation duct: LK 530-010 for ceiling heights of
7 ´´ 3 ´ ´ - 8 ´´ 6 ´ ´ / 2.20 - 2.66 m
LK 530-020 for ceiling heights of
8 ´´ 6 ´ ´ - 10 ´´ 1 ´ ´ / 2.66 - 3.15 m
Aluminium-design ventilation duct: LK 530-011 for ceiling heights of
7 ´´ 3 ´ ´ - 8 ´´ 6 ´ ´ / 2.20 - 2.66 m
LK 530-021 for ceiling heights of
8 ´´ 6 ´ ´ - 10 ´´ 1 ´ ´ / 2.66 - 3.15 m
Fig. 2
1
2
34
Fig. 3
Motor off
Extraction level 1
Extraction level 2
Extraction level 3
Extraction level intensive
Run-on
Lighting