Preface
With your new extractor hood, working in the kitchen will be even more fun.
The appliance offers you a number of
advantages:
– a good extraction capacity with low noise
values, – a large number of control functions, – optimum illumination of the cooking surface by
a dimmable halogen light. To ensure that you will be able to use this appli-
ance in all its diversity, read through the operating and assembly instructions conscientiously before operating it for the first time. The instructions contain important notes on use, installation and maintenance of the appliance.
On the following page you will find important notes on safety and operation. These will serve to ensure your personal safety and the lasting value of your appliance.
You will find notes on page 4 that you ought to observe before operating the appliance for the first time.
The chapters entitled “Structure and operating principle” and “Operation” will tell you all the things your extractor hood is capable of doing and how the appliance is operated.
Tips and hints in the chapter entitled “Cleaning and care” will make sure that your appliance will stay operable and beautiful for a long time.
And now we wish you lots of fun with your new extractor hood.
Fig. 1
1.1 For your safety
– Damaged appliances must not be operated. – The appliance must only be connected by an
authorised specialist, paying attention to the relevant regulations of the power supply companies and the regional construction regulations.
Also observe the assembly instructions!
– Connecting cables must not come into contact
with hot cooking surfaces.
– Do not operate the extractor hood without
inserted lamps.
– Never operate the appliance without a grease
filter.
– Hazardous or explosive substances and vapours
must not be extracted!
– The user is responsible for expert use and the
perfect condition of the appliance.
– Only ever operate the appliance under super-
vision.
Caution! Over-greased filters are a fire risk!
Only ever deep-fry under the extractor under constant supervision. Pay attention to cleaning the grease filter on a regular basis.
Fire risk! Do not flambé meals under the
extractor hood!
– Operation of the extractor hood above a hearth
for solid fuels (coal or wood etc.) is only partly permitted.
– Gas appliances may only be used under the
extractor hood when pots and pans are placed on them!
– When using more than 3 gas-operated rings at
the same time, please operate the extractor hood at level 2 or higher. This prevents a build­up of heat in the appliance.
– For safety reasons, do not place any heavy
objects on the top of the appliance.
– Do not clean the appliance with a steam
cleaning apparatus or with water pressure because this poses a risk of short-circuits.
– Isolate the appliance from the mains during
every maintenance operation. To do this, remove the mains plug or actuate the corresponding fuse. If the mains plug is not accessible, the appliance must be deenergised by means of the domestic installation fuse.
– Repairs must be carried out by authorised
specialists, thus ensuring electrical safety.
– No warranty claims can be lodged in the event
of damage caused by failure to observe these instructions.
– Adequate incoming air must be ensured if a
wood, coal, gas or oil heater or an open hearth is operated in the same room as the one in which the hood is installed.
– Safe operation is possible whenever the partial
vacuum in the place where the firing equipment is installed does not exceed 4 Pa (0.04 mbar). This can be achieved whenever the air needed for combustion is able to enter through openings that cannot be sealed, for example in doors, windows, incoming/exhaust air wall boxes or other technical means.
– If the appliance is to be operated only with the
window open (to ensure adequate incoming air), you can use the window switch. A switch (normally open) is fitted on the window. On the appliance, this switch is connected to the window switch terminal on the main electronics. The appliance can now only be operated when the window is open. Important: the window switch must only be connected by an authorised specialist. Note: the light function works without restriction.
– After a power failure, the extactor will not go on
again automatically. You can recommence operation by turning a knob or by pressing any key.
Technical modifications reserved.
3
1. Important notes
1.2 Operating for the first time
Before operating the appliance for the first time, please pay attention to the following notes:
– The appliance must be installed and connected
by a specialist before it is operated for the first time.
– Conscientiously read through the operating and
assembly instructions before operating the appliance for the first time.
– Remove the packaging from the appliance and
dispose of it properly! Pay attention to the fact that there are accessories in the packaging! Keep packaging elements out of the reach of children!
– Thoroughly clean the appliance before using it
for the first time (see chapter “Cleaning and care”).
– Before operating the appliance for the first time,
check that the mains connection is in proper working order.
1.3 About use
– The appliance is intended solely for use in the
household and must not be put to any other uses.
– In the event of malfunctions, first of all check the
household fuses. If the problem has nothing to do with the power supply, please contact your specialist dealer or your local Gaggenau after­sales service.
4
5
2. Features
1 Outgoing air ducts 2 Control panel 3 Grease filter 4 Lighting
Installation accessories: Stainless steel-design ventilation duct:
LK 530-010 for ceiling heights of 2.20 - 2.66 m LK 530-020 for ceiling heights of 2.66 - 3.15 m
Aluminium-design ventilation duct:
LK 530-011 for ceiling heights of 2.20 - 2.66 m LK 530-021 for ceiling heights of 2.66 - 3.15 m
Fig. 2
1
2
34
Fig. 3
Motor off
Extraction level 1
Extraction level 2
Extraction level 3
Extraction level intensive
Run-on
Lighting
Grease filter saturation display
6
3. Operation
The AH 530/532-190 is 90 cm wide, and the AH 530/532-120 is 120 cm wide. Operation of both extractor hoods is identical. After they have been pressed, all functions selection keys except 0 (“Motor off”) are backlit in green.
Light
The lighting can be switched on or off, regardless of whether the wall extractor is in operation, by pressing the key (see Fig. 4).
When you briefly press the key, the lighting is increased up to the maximum level.
You can dim the lighting to the required level by keeping the key pressed.
Fan levels
Three fan speeds and one intensive speed are available (see Fig. 5). You set the fan level required for each respective cooking situation by pressing the function selector keys 1, 2, 3 or Int.
Fig. 5
Fig. 4
or or or
7
The Int key for the intensive level should be pressed when browning and frying in an open pan (see Fig. 6). If you have switched on the hood by selecting the intensive level, it will be switched off again automatically after 5 minutes.
If you press the Int key while the hood is running at fan level 1, 2 or 3, the electronic control will switch back automatically to the previously selected fan level after 5 minutes (see Fig. 7).
If you would like to end the intensive level before the five minutes have elapsed, press the 0 key (“Motor off”) or select a different level (see Fig. 8). It is possible to switch off the extraction function at any time by pressing the 0 key (motor “off”).
Fig. 6
Fig. 8
Fig. 7
8
Special functions:
Intensive time: You can set the intensive level running time to 3, 5 or 10 minutes by simultaneously pressing the Int key and the 1, 2 or 3 key and you can store this setting (see Fig. 9). When delivered, the appliance is set to five minutes, i.e. the combination of the Int key and the key 2.
Delayed shut-off: Delayed shut-off is possible at any level. First press the required key 1, 2, 3 or Int and then press the key (see Fig. 10). The delayed shut-off time for all levels is ten minu­tes. After these ten minutes, the ventilation switches off, but the lighting stays on.
Interval ventilation: Interval ventilation is a special feature of this appliance which periodically activates the fan for five minutes every hour. You can activate this function by simultaneously pressing the 0 key and, depending on the required extraction capacity, the 1, 2 or 3 key (see Fig. 11). This mode of operation is indicated by alternating illumination of the key together with the corresponding fan level indicator.
You can switch off interval ventilation by pressing the 0 key (see Fig. 12).
Fig. 12
Fig. 10
or or
or
Fig. 9
or or
Fig. 11
or or
9
Cleaning the grease filters
The grease filter saturation display F flashes after an operating time of 30 hours to you indicate to you that you should clean the grease filter (see Fig. 3). The grease filters can of course be cleaned at any time, even if the grease filter saturation display has not started to flash.
The stainless steel grease filters can be removed easily for cleaning (see Fig. 13):
Disconnect the power supply (switch off the fuse). Grip the grease filter handle and push the slide
towards the rear. Then pull the grease filter downwards out of the holder; repeat the operation for the other grease filters.
You can clean the stainless steel grease filters in a dishwasher at a maximum temperature of 65°C, where it should be supported vertically
to allow
food or rinsing residues to drain off. If possible, the inner parts of the housing should be
wiped out in hot rinsing water when replacing the filters.
Caution:
when cleaning the inside of the housing, beware of protruding parts.
After having cleaned them, re-insert the grease filters in the wall extractor in reverse order.
Important:
the handles of both grease filters must be visible after assembly.
Press the F key to set the elapsed hours counter to zero. Flashing of the indicating lamp goes off.
4. Cleaning and care
Fig. 13
Fig. 14
Cleaning the extractor hood Clean the extractor hood and the aluminium-
design ventilation ducts (LK 530-011/021) with a
soft cloth and mild detergent solution only. Clean the stainless-steel design ventilation
ducts (LK 530-010/020) with mild detergent solution and apply stainless steel care agent to the metal surface using a soft cloth.
Cleaning the glass plates Apply commercially available window cleaning
agent with a soft, moist cloth. To facilitate cleaning, you can detach the glass plates as follows: Detach the grease filters. In the extractor hood, you will find three openings on the upper side through which you can lift the glass plates singly with a blunt object (e.g. handle of a wooden spoon) to detach them with greater ease. If they are extremely soiled, the glass plates can be cleaned in a dishwasher at a maximum temperature of 55 °C. Note: when putting the glass plates back in place, make sure that you do not scratch the chimney. Replace the glass plates with the printed side facing down. Position the glass plates at the chimney side first.
Cleaning the aluminium panel Clean the control panel with a sponge and mild
detergent solution only. Dry with a soft, dry cloth. Do not use any strong or caustic cleaning agents or brushes and abrasive cleaner to clean it. Do not use strongly alkaline cleaning agents (such as oven spray) because these are aggressive to the aluminium surface. Do not use any abrasive sponges either.
10
Fig. 15
First disconnect the appliance from the mains before carrying out any repairs.
In the event of malfunctions, first of all check the household fuses.
If the power supply is in proper working order, but the appliance is nevertheless not functioning, then please contact your specialist dealer or your responsible Gaggenau after-sales service. Specify the appliance type (see rating plate).
Repairs must only be carried out by authorised specialists, thus ensuring the safety of the appliance. Improper tampering will render all warranty claims null and void.
Lamp replacement Caution: disconnect the power supply before
replacing lamps (switch off the fuse)! Caution: lamps may still be hot shortly after use!
Risk of burns. – Detach the ring from the lamp cover. Note: make
sure that the glass will not fall out (Fig. 16).
– Pull out the lamp (Fig. 17). Defective lamps must only be replaced by lamps of
the same type! (12 V/20 W/G4 lampholder)
Inserting the lamp
– Insert the lamp in the lampholder.
Note: do not touch the halogen lamps with your hands. Use a cloth and touch the lamp only on its
edges. – Engage the lamp cover. – Connect the appliance to the mains again.
11
5. Maintenance
Fig. 16
Fig. 17
12
6.1 Technical data
AH 530-190: Weight: 23.5 kg
Dimensions: 898 x 550 mm
AH 532-190: Weight: 21.5 kg
Dimensions: 898 x 550 mm
AH 530-120: Weight: 27.5 kg
Dimensions: 1198 x 550 mm
AH 532-120: Weight: 25.5 kg
Dimensions: 1198 x 550 mm
Electrical connection
Pay attention to the rating plate data. The mains connecting cable must at least
correspond to the type H 05 VV-F G 0,75. The appliance must only be connected by an
authorised specialist. The specialist is respon­sible for perfect functioning of the appliance at its installation location. He must explain the operating principle of the appliance to the user with refe­rence to the operating instructions. He must explain to the user how the appliance can be isolated from the mains whenever required.
Connection possibilities
The plug of the connecting cable is inserted into the socket that is located behind the duct cover on the wall. If this is not possible, the disconnection of all the poles of the appliance from the mains must be achieved by way of the domestic fuse, or by using an accessible disconnecting device with a contact gap of at least 3 mm.
6.2 Installation
The applicable regulations of the energy supply companies and the regional construction regulations must be observed when installing the hood.
The minimum distance from the worktop to the bottom edge of the wall hood is for electrical appliances 600 mm and for gas appliances 700 mm.
The wall hood was conceived for the exhaust air mode. The exhaust air can be routed into a separate exhaust air shaft or directly into the open through the outside wall.
It is not allowed to pass the exhaust air into a flue or exhaust air chimney that is in operation or into a shaft that is linked to the heating basement. Consult the chimney sweep responsible for your district whenever you wish to pass the exhaust air into a chimney that is not in operation.
During the course of planning, a chimney sweep must be consulted if a room air-dependent hearth is operated in the same room as the one in which a hood is operated in the exhaust air mode. Adequate incoming air must be ensured. The applicable construction and safety regulations must be observed.
Adequate incoming air must be ensured if a wood, coal, gas or oil heater or an open hearth is operated in the same room as the one in which the hood is installed.
Safe operation is possible whenever the partial vacuum in the place where the firing equipment is installed does not exceed 4 Pa (0.04 mbar). This can be achieved whenever the air needed for combustion is able to enter through openings that cannot be sealed, for example in doors, windows, incoming/exhaust air wall boxes or other technical means.
6. Assembly instructions
13
Flexible aluminium pipes, corrosion-protected sheet metal pipes and exhaust air pipes whose material conforms to fire B1 in accordance with DIN 4102 can be used. Exhaust air pipes should have a nominal diameter of 150 mm.
Pay particular attention to ensuring that – the exhaust air ducts and pipes are kept as short
as possible
– the pipes are not laid at an acute angle, but as
bends and that they are inserted into the shaft at an inclined upward angle and
– there are no cross-sectional constrictions in the
upward direction (this reduces the volume flow).
As standard, the blow-out opening of the wall hood is in the upward direction.
To pass exhaust air through the outer wall, we recommend the use of our telescopic wall box TM 150-045 (Ø 150).
Note:
To prevent the ingress of water, e.g. condensate or rain water from an uncovered exhaust air shaft, our condensate separator RV 060-150 must be installed in the exhaust air line. The condensate separator must still be acciessible after installation.
The duct units listed below are available depending on the height of the ceiling:
Stainless steel-design ventilation duct:
LK 530-010 for ceiling heights of 2.20 - 2.66 m LK 530-020 for ceiling heights of 2.66 - 3.15 m
Aluminium-design ventilation duct:
LK 530-011 for ceiling heights of 2.20 - 2.66 m LK 530-021 for ceiling heights of 2.66 - 3.15 m
The dimensions above refer to a distance of 1.60 m from the floor to the bottom edge of the hood.
If required, custom made duct units are available at an extra charge.
The socket must be place behind the duct cover on the wall.
Fig. 18
550
260
100
480
1600
600 - 1550 Hood height
min. 600
over electric cooker
min. 700
over gas cooker
2.20 - 3.15 Ceiling height
The following note applies to extractor hood AH 532-190 or AH 532-120 only; these models do not have an integrated fan:
The extractor hood can only be used in exhaust air mode. The exhaust air is conveyed upwards through an externally attached fan via a ventilation shaft or directly into the open air through the outer wall.
The extraction function is realised by an external fan module. We recommend the fan modules GB 032-107 or GB 052/053-140 from our Gaggenau range; the extractor's electronic circuitry is optimised for these fan modules.
For the electrical connection between the extractor hood and external fan see installation instructions for the external fan.
For safety reasons, if the connecting cable to the external fan has been damaged, it must be replaced by the manufacturer or the after sales service or similarly qualified persons.
14
15
Proceed as follows:
– From the bottom edge of the hood, mark a center
line on the wall. – With the aid of the drilling template, mark the
positions of the screws on the wall (Fig. 19). – Pay attention to the minimum clearance of 600 mm
for electric cookers and 700 mm for gas cookers.
The bottom edge of the template corresponds to
the bottom from edge of the hood. – Using the drilling template, drill the 6 holes for
the hood (area I of the drilling template) and the
two holes for suspending the chimney (area II of
the drilling template). In the top two securing
holes for the hood, fix the two hooks d with the
countersunk screws c. Make sure that the hooks
lie flatly on the wall. In certain circumstances you
may have to countersink the drill holes. Fit the
included dowels a in the other drill holes. Note: pay attention to any special accessories that
you may have to fit. – Screw on the retaining bracket for the chimney
paneling. – Detach the grease filters. – Hang the hood on the two hooks. Adjust the
suspended element with the recessed head
screw and align the hood using a spirit level
(Fig. 20).
396
62
270
300
15
310
mind. 600 Elektro mind. 700 Gas
230
76,5
782/1082
Fig. 19
Fig. 20
Important: before marking the securing holes, make sure that no electricity or water lines or other lines are laid at the drilling points in the wall.
min. 600 electric min. 700 gas
– Secure the hood on the wall with the four screws
b (Fig. 21). – Establish the pipe connection. – Establish the electrical connection. – Stainless steel chimney only (LK 530-010/020):
pull the protective film off the chimney’s trims. Note: avoid damaging the sensitive metal surfaces. – Fit the top chimney duct unit into the base. Make
sure that the fastening holes on the side are at the
top. – Put both chimney duct units onto the hood. – Pull the top chimney duct unit up into its final
position and secure it with 2 screws on the ceiling
holder (Fig. 22). Note: avoid scratches when pulling the elements
apart by placing the assembly template, for example, over the edge of the bottom chimney paneling to protect it.
– Reinsert the grease filters. – Place the glass plates on the appliance with the
printed side facing down. Note: when putting the glass trays in place, make
sure that you do not scratch the chimney.
16 5750202534 en 12.02 SK
Fig. 21
Fig. 22
Loading...