Fujitsu R450 User Manual

PRIMERGY R450
System configurator and order-information guide
November 2003
Contents
Instructions Configuration diagram Configurator
0 System software I Basic unit II Processor III Memory IV Graphics V Accessible drives VI Hard disk drives VII SCSI controller VIII Disk array IX Communication/Network X System Management Products XI Miscellaneous XII National accessories packs
Change report
PRIMERGY Server
System configurator and order-information guide
PRIMERGY R450 Status 2003-10-24
Instructions
This document contains basic product and configuration information that will enable you to configure your system via
PC-/ System-Architect.
Only these tools will ensure a fast and proper configuration of your PRIMERGY server or your complete
PRIMERGY Rack system.
You can configure your individual PRIMERGY server in order to adjust your specific requirements.
The System configurator is divided into several chapters that are identical to the current price list and PC-/ System-Architect.
Please follow the lines. If there is a junction, you can choose which way or component you would like to take. Go through
the configurator by following the lines from the top to the bottom.
Section
In one chapter you can only select as many components (here 4x) as the arrow indicates
Please note that there are information symbols which indicate necessary information
Further information in the internet see:
http://www.primergy.com
(internet)
http://extranet.fujitsu-siemens.com/primergy
(extranet)
Prices and availability see price list and PC-/ System-Architect.
Subject to change and errors excepted.
X times
III
S26361-XXX-XXX S26361-XXX-XXX
Memory XXX MB Memory XXX MB
max. X times per system max. X times per system
Memory, example
There are X memory slots which can be equipped with XXX MB It is permissible to make up to X passes through the memory upgrade options
4x
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
2 of 12
System configurator and order-informtion guide
PRIMERGY R450 Status 2003-10-24
TOP VIEW
FRONT VIEW
System unit ( I )
Extension slots
Peripheral Bay ( V )
Graphics ( IV )
3.5"x0.5"
LCD
SCSI controller ( VII )
floppy disk
Disk array ( VIII )
Communication/Network ( IX )
Hard Disk Drives ( VI )
2 channels
Channel 1
18PCI-X long 64 Bit / 100 MHz hot-plug
SCSI-ID 0
SCSI-ID 1
SCSI-ID 2
Channel 0
17PCI-X long 64 Bit / 100 MHz hot-plug
3.5"x1"
3.5"x1"
3.5"x1"
SCSI-ID 0
SCSI-ID 1
SCSI-ID 2
26PCI long 64 Bit / 66 MHz hot-plug
Hot-plug power supply 500W ( I )
35PCI-X long 64 Bit / 100 MHz hot-plug
3. PS
2. PS
1.PS44
PCI-X long 64 Bit / 100 MHz hot-plug
Interface: WIDE SCA (80 pins)
53PCI-X long 64 Bit / 100 MHz hot-plug
62PCI long 32 Bit / 33 MHz
61PCI long 32 Bit / 33 MHz
Memory ( III )
The highest assembled bank
is the hot-spare bank,
if the feature is enabled
Processor ( II )
Processors must be plugged
in order according the picture
Xeon MP 3
Xeon MP 4
Xeon MP 2
Xeon MP 1
5.25"x0.5"
IDE-drive
Slot
PCI Bus
Configuration diagram PRIMERGY R450
3.5"x1" 3.5"x1" 3.5"x1"
Bank 4 (4 modules)
Bank 3 (4 modules)
Bank 2 (4 modules)
Bank 1 (4 modules)
Enterprise Products - PRIMERGY Server
Fujitsu Siemens Computers
3 of 12
System configurator and order-informtion guide
Start "PRIMERGY R450"
PRIMERGY R450 Status 2003-10-24
http://www.primecluster.com
http://vil.mch.fsc.net/vil/pc/vil/primergy/overview/prince/index_en.htm
for internal users:
http://vil.mch.fsc.net/vil/oec/special/primergy/index_en.htm
for partners:
http://vilpart.fujitsu-siemens.de/vil/oec/special/primergy/index_en.htm
SW Configurator
with OEM-Software without OEM-Software
for PRIMERGY Server for PRIMERGY Server
Later use of OEM operating system
Vmware-Software the use of OEM-software apart from OEM software by
- ESX Server 1.5 (OEM) under ESX. VMware and F5
- ESX Server 2.0 (OEM)(planned) Distributions-/ retailware is
- Virtual SMP for ESX 2.0 (OEM) allowed.
For all SW products listed below please refer to the corresponding software configurator accessible via the Extranet under "PC Configurations, Configurator for PRIMERGY SW", URL see below
MS - Software: W **) Novell - Software: ***) PRIMECLUSTER *)
- NT 4.0 Server - NetWare 5.1 - Clustering
- NT 4.0 Server Enterprise Edition - NetWare 6 - Load Balancing
- NT 4.0 Server Terminal Server Edition - NetWare 6.5 (planned)
- Windows 2000 Server - NetWare Cluster Services 1.6 and
- Windows 2000 Advanced Server - NetWare Cluster Services 1.7 Linux - Software: **)
- Windows Server 2003, (planned) with FibreCAT - SuSE Linux Enterprise Server: S Standard Edition CX200, CX400, CX600 - SuSE Professional Linux Enterprise Edition - Red Hat Enterprise Linux
Microsoft does not allowe software is not allowed,
- Red Hat Professional Linux
CITRIX-Software für NT: W1 - UnixWare 7
- Multiuser SW MetaFrame LoadBalancing additional User Lizenzen
MultiPath, Duplex Data easy Mirror for Linux Manager for NT; W2K; Linux NT 4, WIN 2000
FSC System Management Software: V
- RemoteView Software
- RemoteView Service Board
- RemoteView Diagnosis **) Pay attention to release and order information in PRINCE -> Operating System
Backup-Software: U
- ARCserve für NT
You'll find single software configurators and release lists (OS-matrix / system management / security) under following addresses:
*) Pay attention to release information on datasheet under
***) Supply over distribution or procurement from FSC VP BC Software
SCO - Software: **)
Continue with PRIMERGY HW configurator
Enterprise Products - PRIMERGY Server
Fujitsu Siemens Computers
4 of 12
System configurator and order-information guide
Start PRIMERGY R450
PRIMERGY R450 Status 2003-10-24
Section
Rack basic unit 4U including The PRIMERGY R450 basic unit comes with:
1 x Xeon MP CPU - 3 power supply module, hot-plug redundant 2 channel - 2 channel HD PBay with 3 HD bays each
S26361-K845-V200 1,5GHz 1 MB TLC - 2 hot-replace and redundant fans S26361-K845-V201 1,9GHz 1 MB TLC - a CPU Board for up to 4x Xeon CPUs S26361-K845-V202 2 GHz 2 MB TLC - a Memory Board for 16 memory slots
PRIMERGY PRIMECENTER- Rack
I
Basic unit
- 1 floppy disk drive 1,44MB
- I/O section with
- System Management Processor
- Dual LVD/U3W-SCSI controller (Adaptec 7899)
- VGA graphics 8 MB ATI
- LAN 10/100 Mbit with RJ45 connector (Intel 82559)
- 5 64bit / 100 MHz PCI-x slots, 1 64bit / 66 MHz slot, all hot-plug
- 2 32bit / 33 MHz long PCI slots
- ServerStart packet incl. ServerBooks CD, ServerSupport CD and ServerView
Mounting kit for PRIMERGY R450
- 1 pair of telescopic rails (730-810mm)
- 1 pair of carrier rails
- 1 bracket PC-Rack
- 1 cable management PC-racks
Mounting kit for mounting of servers in FSC 19" PRIMECENTER- racks and all server racks conforming to EIA standard EIA-310-D for 19" racks. Therefore the mounting kit is variable in deepth from 730-810mm
SNP:SY-F1647E301-P 2 x RS-232-C (serial, 9 pin) 1 x RS-232-C (serial, 9 pin) Installation ex works for one 1x Centronics (parallel, 25 pin, 1 x RJ45 LAN server or subsystem. EPP/ECP compatible) 1 x Power Jack Hereby the rack will be delivered 1 x keyboard (PS/2) completely pre-mounted and 1 x mouse (PS/2) all wired connections are tested. 1 x VGA (15 pin)
With racks 12U, 24U, 38U: 1 x USB Frontside Systems and components 2 x USB Backside will be delivered installed in the rack 1 x RJ45 LAN With racks 46U: Systems and components will be delivered separately "Rack-mounting ex factory" To be ordered only together with This service is to be ordered once a PRIMERGY- per installable server/storage PRIMECENTER rack subsystem, in order to get the e.g.: server/storage subsystem S26361-K826-V10x mounted into the PRIMERGY racks.
refer configurator PC-Rack In case of the 46 U PRIMERGY Rack, max. 1x per System this service has to be ordered,
important notice ! This kit can be ordered,
the mounting kit for PRIMERGY R450 if it is planned to mount the rack is included the basic version and version in an already available will be delivered with every R450 FSC 42/23U rack
External Interfaces External Interfaces for ServerManagement
to get the mounting kits and the cables installed
PRIMERGY 42/23U Rack
S26361-F1331-L141
Mounting kit for 42/23U rack
- 1 pair of carrier rails
- 1 pair of telescopic rails
- 1 cable carrier max. 1x per system
A
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
5 of 12
System configurator and order-information guide
A
PRIMERGY R450 Status 2003-10-24
There are 3 bays for hot-plug power supplies, each with 500W Each basic unit contains 3 modules and provides redundancy for a fully equipped system
up to
Section
II
S26361-F2817-E151 S26361-F2817-E191 S26361-F2817-E202
XEON MP 1,5GHz XEON MP 1,9GHz XEON MP 2GHz with 1 MB TLC on Chip, with 1 MB TLC on Chip, with 2MB TLC on Chip,
Processor
A mix of processors with different clock frequency and different On-Chip cache cannot be used The multi-processor system premises a multi-processor operating system Terminators are not necessary
3x heat sink and "Easy retention" heat sink and "Easy retention" heat sink and "Easy retention"
occupies slot for one CPU occupies slot for one CPU occupies slot for one CPU max. 3x per system max. 3x per system max. 3x per system
Section
III
Memory
There are 16 memory slots available (4 banks, 4 modules each) They can optionally be equipped with 128 MB, 256 MB, 512 MB or 1GB registered DDR-RAM modules (PC1600)
The maximal extension is 16 GB with today available 1GB modules!
Any mix of modules within one memory bank is not allowed ECC with memory scrubbing and chipkill is standard Optional hot-spare memory functionality can be configured in the BIOS (redundant memory bank 3 + 1)
S26361-F2550-E542 S26361-F2550-E543 S26361-F2550-E544 S26361-F2550-E545
Main memory 512MB Main memory 1024MB Main memory 2048MB Main memory 4096MB PC1600 registered DDR RAM PC1600 registered DDR RAM PC1600 registered DDR RAM PC1600 registered DDR RAM
4x
consisting of 4 modules consisting of 4 modules consisting of 4 modules consisting of 4 modules occupies one bank occupies one bank occupies one bank occupies one bank max. 4x per system max. 4x per system max. 4x per system max. 4x per system
Section
IV
B
Graphics
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
6 of 12
System configurator and order-information guide
B
PRIMERGY R450 Status 2003-10-24
Section
SNP:SY-F2313E1-P SNP:SY-F2312E1-P A CD-ROM or DVD-ROM drive is required for
CD-ROM 0,5" 24xATAPI DVD drive 0,5" installing the system with "Sever Start"
V
Accessible drives
1x Connector: LD50 8/24x or faster supplied with the system unit!
incl. description (Ger/US) anthracite bezel
0.5" * 5.25", anthracite bezel occupies one drive bay CD-ROM in the max. 1x per system max. 1x per system basic unit!
Section
VI
SNP:SY-F2336E118-P SNP:SY-F2336E136-P
Hard disk 18GB Hard disk 36GB 10000rpm, <7ms, min. 4MB Cache 10000rpm, <7ms, min. 4MB Cache
U160 SCSI (160 MB/sec) U160 SCSI (160 MB/sec)
Interface: WIDE SCA (80 pins) Interface: WIDE SCA (80 pins) hot pluggable drive hot pluggable drive occupies 1" bay occupies 1" bay max. 6x per system max. 6x per system
Hard Disk Drives
while stocks last
S26361-F2336-E173 S26361-F2336-E114
Hard disk 73GB Hard disk 146GB 10000rpm, <7ms, min 8MB Cache 10000rpm,<5,5ms,min. 8MB Cache
U160 SCSI (160 MB/sec)
Interface: WIDE SCA (80 pins) Interface: Wide SCA (80-pins) hot pluggable drive hot pluggable drive occupies 1" bay occupies 1" bay max. 6x per system max. 6x per system
Note: There is no
Ultra 160 SCSI (160MB/s)
S26361-F2336-E518 S26361-F2336-E536 S26361-F2336-E573
Hard disk 18GB Hard disk 36GB Hard disk 73GB 15000rpm, <4ms, min. 8MB Cache 15000rpm, <4ms, min. 8MB Cache 15000rpm, <4ms, min. 8MB Cache
Ultra 160 SCSI (160MB/s) Ultra 160 SCSI (160MB/s) Ultra 160 SCSI (160 MB/sec)
Interface: Wide SCA (80-pins) Interface: Wide SCA (80-pins) Interface: Wide SCA (80-pins) hot pluggable drive hot pluggable drive hot pluggable drive
max. 6 occupies 1" bay occupies 1" bay occupies 1" bay
max. 6x per system max. 6x per system max. 6x per system
S26361-F2764-E136 S26361-F2764-E173 S26361-F2764-E114
Hard disk 36GB Hard disk 73GB Hard disk 146GB 10000rpm,<5,5ms, 8MB Cache 10000rpm,<5,5ms, 8MB Cache 10000rpm,<5,5ms, 8MB Cache
Ultra 320 SCSI (320MB/s) Ultra 320 SCSI (320MB/s) Ultra 320 SCSI (320MB/s)
Interface: Wide SCA (80-pins) Interface: Wide SCA (80-pins) Interface: Wide SCA (80-pins) hot plug/hot replace tray hot plug/hot replace tray hot plug/hot replace tray occupies 1" bay occupies 1" bay occupies 1" bay SCSI/RAID controller necessary SCSI/RAID controller necessary SCSI/RAID controller necessary max. 6x per system max. 6x per system max. 6x per system
S26361-F2764-E518 S26361-F2764-E536 S26361-F2764-E573
Hard disk 18GB Hard disk 36GB Hard disk 73GB
15.000rpm,<4ms, 8MB Cache 15.000rpm,<4ms, 8MB Cache 15.000rpm,<4ms, 8MB Cache
Ultra 320 SCSI (320MB/s) Ultra 320 SCSI (320MB/s) Ultra 320 SCSI (320MB/s)
Interface: Wide SCA (80-pins) Interface: Wide SCA (80-pins) Interface: Wide SCA (80-pins) hot plug/hot replace tray hot plug/hot replace tray hot plug/hot replace tray occupies 1" bay occupies 1" bay occupies 1" bay SCSI/ RAID controller necessary SCSI/ RAID controller necessary SCSI/ RAID controller necessary max. 6x per system max. 6x per system max. 6x per system
C
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
7 of 12
System configurator and order-information guide
C
PRIMERGY R450 Status 2003-10-24
Section
VII
A. on-board SCSI Controller for internal hard disks
2-channel U160-SCSI controller on-board; included as standard
The following cabling is standard, if no Disk Array Controller is used
1. Channel A of the U160 controller is connected to the 1st backplane for 3 HDs
2. Channel B of the U160 controller is connected to the 2nd backplane for 3 HDs
S26361-F2287-E15
External on-board SCSI Interface besides the 0-channel RAID Controller is used Cable and external See section Disk Array Controlller connector interface max. 2x per system for external
B. SCSI - controller for external hard disk extensions and external peripheral devices.
SNP:SY-F1722E1-P S26361-F2399-E1
SCSI Controller UW, DE SCSI U160 Controller Adaptec 2944UW (HBA) Adaptec SCSI card 29160 Supported only in Microsoft Windows 1 channel differential-ended 1 channel: LVD+Fast/Ultra (decoup.) max. 40MB/s; without cable LVD con. for HD, withoud cable
4x
32/33 PCI, min. 170mm int: LD50 + HD68, ext: HD68(S) SW: int: Fast 50-pin or Ultra HD68 max. 2x per system
SCSI-/Fibre-channel controller
This interface is only configurable if a RAID Controller
while stocks last
Fast/Ultra con. access. drives 64/66 (32/33) PCI, min. 180mm
+ LVD HD68; ext: HD68(LVD) SW: max. 2x per system
Controller for the connection of a EMC Symmetrix (only available as option)
NT and Windows 2000 operating systems
5x
C. Fibre Channel controller for subsystems and SAN
SNP:SY-F2244E1-P SNP:SY-F2244E2-P
1GBit/s FC Controller 1GBit/s FC Controller Qlogic Qlogic QLA 2200 QLA 2200F, full height braket 1 Channel 1GBit/sec FC Controller 1 Channel 1GBit/sec FC Controller CU (copper) Interface MMF(Multimode Fibre) Interface incl. SW and description (Ger/US) incl. SW and description (Ger/US) PCI 64Bit / 66MHz, 175mm PCI 64Bit / 66MHz, 175mm
3.3V and 5V tolerant signaling 3.3V and 5V tolerant signaling
4x
max. 4x per system max. 4x per system
while stocks last while stocks last
S26361-F2843-E1 S26361-F2624-E1 suitable for 2GBit/s FC Controller 2GBit/s FC Controller Emulex Emulex LP9802 LP9002L 1 Cannel 2GBit/sec FC Controller 1 Channel 2GBit/sec FC Controller Attention LC Interface for 50um Fiber LC Interface for 50um Fibre 2GBit/s FC Controller PCI 64Bit / 133MHz, 170mm PCI 64Bit / 66MHz, 170mm require other interface
3.3V and 5V tolerant signaling 3.3V and 5V tolerant signaling connectors for the max. 4x per system max. 4x per system
SNP:SY-F1826L1-P FC Ctrl for EMC2 Attachment
Emulex LP8000 1 channel 100MB/s systems. such as switches, GBICs MMF (Multimode Fibre) Interface or cables which can be Connector: Duplex SC Controller for the connection ordered for fibre channel SAN without cable, order seperately of a EMC Symmetrix, FibreCAT attachments. (see price list) incl. SW a. description (Ger/US) (only available as option) PCI 64Bit/33MHz controller max. 4x per system
freigegeben 1GBit/s fibre channel.
Supported only in Microsoft Windows NT and Windows 2000 operating There are other components
while stocks last
64Bit/66MHz PCI-Slot
optical cables than
to be continued For the configuration of external cabling see the configurator for external storage systems on next page
D
All controllers for the connection of external storage systems are delivered without cables
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
8 of 12
System configurator and order-information guide
D
PRIMERGY R450 Status 2003-10-24
4x
Section
VIII
D. 0-channel Ultra RAID Controller
The following cabling is standard, if any Disk Array Controller is used
1. Channel A of the RAID Controller is connected to the 1st backplane for 3 HDs
2. Channel B of the RAID Controller is connected to the 2nd backplane for 3 HDs
S26361-F2728-E48
Zero-channel RAID Controller Adaptec 2000 S 48MB SDRAM ECC Cache in combination with on-board U160 SCSI Controller without cable S26361-F2569-E64 incl. SW and description (Ger/US) 64/66 PCI Controller Mylex / LSI
3.3V signaling max. 1x per system 64MB SDRAM ECC Cache
S26361-F2385-E32
2-channel RAID Controller U160 Adaptec 3200 S 64/33 PCI Controller, 330mm 32MB SDRAM ECC Cache BBU optional connector: int. 2x HD68; ext. 2x VHDCI without cable S26361-F2569-E10 incl. SW and description (Ger/US) 64/33 PCI Controller, 330mm max. 1x per Controller
3.3V and 5V tolerant signaling max. 4x per system
Disk Array
zero-channel RAID Controller Adaptec 2000S is always to be installed in slot 6
2-channel RAID Controller U160
AcceleRAID 352 (Leopard)
BBU optional
The cables for the connection of the external: 2x VHDCI RAID Controller to the disks in the system are included within the basic unit. incl. SW and description (Ger/US)
The cables of the connection from the subsystems (SX30 / S60) to the RAID Controllers, see configurator SX30 / S60
Connector: internal 2x HD68;
without cable
3.3V and 5V tolerant signaling max. 4x per system
RAID Ctrl, Battery Backup Unit
4x
Max. 8 controllers in basic unit
to be continued on previous page
S26361-F2386-E32 S26361-F2190-E128
RAID Ctrl, Cache Upgrade 32MB 32 MB SDRAM ECC Cache Mylex / LSI max. 1x per Controller eXtremeRAID 2000 (Big Apple)
S26361-F2386-E10 connector: internal: 2x HD 68; RAID Ctrl, Battery Backup Unit external: 4x VHDCI max. 1x per Controller incl. SW and description (G/USA)
as soon as available max. 4x per system
S26361-F2752-E128
2-channel RAID Controller U320 Adaptec 2200S 128MB SDRAM ECC Cache BBU optional plug: internal 2x HD68; external: 2x VHDCI without cable incl. SW and description (Ger/US) 64/66 PCI controller, 180mm
3.3V and 5V tolerant signaling max. 4x per system
S26361-F2752-E10
Cache Battery Backup Unit max. 1x per controller
4-channel RAID Controller U160
128MB SDRAM ECC Cache BBU
64/33 PCI Controller, 330 mm
3.3V and 5V tolerant signaling
E
The fitting connection cables can be found in the configurator "external storage systems"
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
9 of 12
System configurator and order-information guide
E
PRIMERGY R450 Status 2003-10-24
Section
4x
IX
on-board LAN Controller
Fast Ethernet Contr. on-board The Intel LAN controllers 10/100TX, 1000SX, 1000TX Intel Ethernet Express Pro100+ can be used with the on-board controller in Teaming Mode. Server Adapter, Intel ext: for RJ 45-connector SW: AFT, VLAN, Fast Channel
A) Adapters with Teaming capability 10-1000TX/SX
S26361-F2643-E1 S26361-F2839-E1
Fast Ether. Contr. 10/100TX Gigabit Ethernet Contr. 1000TX Intel 100S Server Adapter Intel Pro/1000 MT Adapter AFT unter NT, W2k, NW also with on-board LAN, WOL, load bal. ext: for RJ45-plug, Cat 5 32/33 PCI , min 120 mm, hp ext: for RJ45-connector SW: VLAN, Fast Etherchannel max. 4x per system
S26361-F2732-E1 S26361-F2730-E2
Gigabit Ethernet Contr. 1000SX Gigabit Ethernet Contr.1000TX-G2 Intel Pro/1000 XF Server Adapter Intel Pro/1000 XT Server Adapter Adapter Teaming Support Adapter Teaming Support PCI-X (all PCI slots), min 163 mm PCI-X (all PCI slots), min 163 mm ext: for Duplex SC-connector ext: for RJ45-Connector, Cat 5
SW: VLAN, Fast Etherchannel SW: VLAN, Fast Etherchannel max. 4x per system max. 4x per system
Communication / Network
PCI 32 (33/66MHz), min 122 mm
connection with Cat 5 cabling SW: VLAN, Fast Etherchannel max. 4x per System
Connection with Cat 5 cabling
freigegeben.
B) Dual Port Adapter 100TX
S26361-F2606-E1 restriction for several countries.
Fast Ethernet dual 10/100TX IPsec No restriction to countries of the EU and: Intel Pro 100S Dual Port Server - Australia, Controller with IPsec 3DES - Canada, AFT under NT, W2k, NW also with on-board LAN, WOL, load bal. - Hungary 64/66 bit PCI, min 120 mm, hp - Japan, ext: for 2 x RJ45-connector - New Zealand, SW: VLAN, Fast Etherchannel max. 2x per system - Poland,
C) Token Ring Adapter
S26361-F2117-E502
Token Ring Controller Smart Ringnode MK4 100/16/4 Mbit, Madge
2x
AFT (NT4, W2K) with 2 Contr., 2 redundant rings with 4 contr. 32/33 PCI, min. 164 mm ext: for RJ45 or SUB-D9-plug SW: max. 2x per system
while stocks last
IPsec with 3DES (156 bit key) has export
- Czech Republic,
- Norway,
- Switzerland,
- United States
F
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
10 of 12
System configurator and order-information guide
F
PRIMERGY R450 Status 2003-10-24
Section
Section
X
S26361-F1790-E219 RemoteView Software V3.10
remote maintenance software, manual
S26361-F2116-E8 RemoteView Diagnosis
IDE Chipdisk at the on-board IDE-Controller occupies 1* IDE slot max. 1x pro System
S26361-F2425-E220
RemoteView Battery Backup Unit for on-board System Management Processor max. 1x per system
XI
System Management Products (RemoteView)
Miscellaneous
without graphical console redirection
RemoteView external Power Supply
S26361-F2425-L300 incl. power cord (with cold device- and Euro plug)
Section
XII
S26361-F1652-L4
Modem external 56kbps (V.90) MultiTech MT5643ZBA-Global international approval incl. 2m Telephon cord RJ11/RJ11 Adapter Plug RJ11/TAE Serial Interface cable DB25m / DB9f AC-Adapter w. German Power Cord occupies one COM port max. 1x per system
needed for RemoteView
National accessories packs
Options and other peripherals
For other options, refer to separate "Product specific options" These options are supplied lose with the shipment For suitable peripherals for this product, please refer to the section "Peripherals/communication"
Country specific power cords are not required for rack versions, except for USA&Canada. Power cords are shipped in a rack version with inlet connector for non-heating apparatus. Description in englisch. Both included in basic unit. (1x with Standard PSU, 3x with hot plug upgrade)
T26139-Y1742-L10 USA, Canada
For shipments to USA&Canada, you have to order one power cord (1,8m, grey) per power supply.
In connection with rack configurations the install variant of the modem (S26361-F1652-E4) has to be ordered (see rack configurator)
End PRIMERGY R450
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
11 of 12
Change report
Date
Order number
Change
System configurator and order-information guide
PRIMERGY R450 Status 2003-10-24
2003-08-13 2003-08-13 2003-08-13 2003-08-13 2003-08-13 2003-08-13 2003-08-13 2003-08-13 2003-07-22 2003-07-22 2003-06-24 2003-05-22 2003-04-25 2003-03-19 2003-02-12 S26361-F2606-E1 Dual Fast Ethernet 10/100TX Ipsec - max. 2x per system possible 2003-01-24 Section Communication / Network: Number of Ethernet Controllers changed 2003-01-22 S26361-F2336-E114 Hard disk 146GB 10000rpm - now available 2002-12-12 S26361-F2636-E361 2002-12-12 S26361-F2636-E350 2002-12-12 S26361-F2636-E161 2002-12-12 S26361-F2636-E150 2002-12-12 S26361-F2636-E140 2002-12-12 2002-12-12 2002-12-12 2002-10-23 S26361-F2636-E361 2002-10-23 S26361-F2636-E350 2002-10-15
2002-10-15
2002-08-21 2002-08-20 S26361-F2425-L300 RemoteView external Power Supply inclusive power cable G and power cable rack - now available
2002-08-19 2002-08-19 2002-07-23 2002-06-24 2002-06-24 2002-06-14 2002-04-18 S26361-F2636-E361 Special action 3 Xeon processors 1,6GHz - now available 2002-04-18 S26361-F2636-E350 Special action 3 Xeon processors 1,5GHz - now available 2002-03-14
S26361-F2764-E573 Hard disk 73GB 15.000rpm Ultra 320 SCSI - now available S26361-F2764-E536 Hard disk 36GB 15.000rpm Ultra 320 SCSI - now available S26361-F2764-E518 Hard disk 18GB 15.000rpm Ultra 320 SCSI - now available S26361-F2764-E114 Hard disk 146GB 10.000rpm Ultra 320 SCSI - now available S26361-F2764-E173 Hard disk 73GB 10.000rpm Ultra 320 SCSI - now available S26361-F2764-E136 Hard disk 36GB 10.000rpm Ultra 320 SCSI - now available S26361-F2752-E10 Cache Battery Backup Unit - now available S26361-F2752-E128 2-channel RAID controller U320 Adaptec 2200S - now available S26361-F2730-E2 Gigabit Ethernet Controller 1000TX-G2 - now available S26361-F2730-E1 Gigabit Ethernet Controller 1000TX - no longer available S26361-F2843-E1 2GBit/s FC Controller Emulex LP9802 - now available T26139-Y1742-L10 Power cord for direct deliverys to USA, Can - now available S26361-F2336-E573 S26361-F2839-E1
S26361-K845-V102 S26361-K845-V101 S26361-K845-V100
S26361-F2817-E151 S26361-F2817-E191 S26361-F2817-E202 S26361-K845-V200 S26361-K845-V201 S26361-K845-V202 S26361-F2636-E350 3x XEON 1,5GHz/512 - no longer available
S26361-F1652-L4 SNP:SY-F1652L3-A Section VII B. SCSI - controller for external hard disk extensions ... - now 4x available SNP:SY-F2244E2-P FC Controller 66MHz, MMF Interface - available further on SNP:SY-F2244E1-P FC Controller 66MHz, Cu Interface - available further on
Hard disk 73 GB 15000rpm, U160 SCSI - now available Gigabit Ethernet Contr. 1000TX Intel Pro/1000 MT Adapter - now available
3 Xeon Processors - 1,6GHz 1MB TLC - Special action - no longer available 3 Xeon Processors - 1,5GHz 512KB TLC - Special action - no longer available Xeon Processor MP 1,6GHz 1MB TLC - no longer available Xeon Processor MP 1,5GHz 512KB TLC - no longer available Xeon Processor MP 1,4GHz 512KB TLC - no longer available Basic Unit 1,6GHz 1MB TLC - no longer available Basic Unit 1,5GHz 512KB TLC - no longer available Basic Unit 1,4GHz 512KB TLC - no longer available 3 Xeon processors - 1,6GHz/1Mb - special action - now available 3 Xeon processors - 1,5GHz/512Kb - special action - now available new processors: 1,5GHz 1 MB iL3 - now available 1,9GHz 1 MB iL3 2 GHz 2 MB iL3 new basic units: 1,5GHz 1 MB iL3 - now available 1,9GHz 1 MB iL3 2 GHz 2 MB iL3
power cable UK/US removed Modem extern 56kbps (V.90); Multitech - now available
Modem extern 56kbps (V.90); Microlink - no longer available
Rack mounting: universal installation kit - now available
First release
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
12 of 12
Loading...