PRIMERGY N800
Configuration of Clustering
Rackmount
Index
1 CPU slot
2 RAM module slot
3 3.5 inch HDD Bay
4 5 inch Bay
5 RS-232C
6 PCI slot
7 ISA slot
8 Redundant PSU
9 Others
Key to
PRIMERGY N800 Datacenter Server
System Configuration Guide (Ver.2) (Jul / 2001
The numbers on the left hand side of each
e correspond to the various options
available with PRIMERGY as follows
2
8
9
r And
Type Rackmount
Product ID PGTN8BHRD2 PGTN8BGRD2
CPU Processor Pentium® lll Xeon™
Frequency 700MHz
Secondary cache 2MB 1MB
Number of CPUs 2 (up to 8)
Memory Standard 1GB (256MB x 4)
5-inch Two (one occupied by DVD-ROM)
CD-ROM/DVD-ROM 8/24X DVD-ROM (IDE)
HDD bay 1inch x4/Hotplug
Available HDD 9.1GB(10000rpm)/18.2GB(10000/15000rpm)/36.4GB(10000rpm)
Maximum 145.6GB (36.4GB x 4)
Expansion slot PCI64bit 66MHz x4, PCI64bit 33MHz x 6
SCSI Interface Internal: Ultra2 Wide SCSI x 1, External: Ultra2 Wide SCSI x 1
RAID controller 2 x Ultra160 (occupying one 64bit/33MHz PCI slot)
Network LAN(10/100 base TX) x 1 (occupying one 64bit/33MHz PCI slot)
Dimension (mm) 445(W)x712(D)x312(H) Rackmount7U
Weight 60kg (max.)
Power consumption 710W (max.)
Power supply Three standard units (the third unit is for redundant)
Operating System Windows2000® Datacenter Server Operating System is bundled
PRIMERGY N800 (Windows®2000 Datacenter Server)
Standard Memory Board
2
5
6
B
#1 #2 #3 #4
#5 #6 #7 #8 #9 #10 #11 #12
#13 #14 #15 #16
2
5
6
B
#1 #2 #3 #4
#5 #6 #7 #8 #9 #10 #11 #12
#13 #14 #15 #16
Additional Memory Board (PG-RB103)
Features of Windows2000 Datacenter Server
The technical features of Windows2000 Datacenter Server include:
Support for up to 64GB of real main memory
4nodes clustering
Load distribution services (NLB Network Load Balancing Service)
Efficient communication between systems (WSDP Windows Socket Direct Path)
Process control
Support for up to 32way SMP (Symmetric Multi Processing) systems
The table below shows a comparison of Windows2000 Server products:
Function
Processor limit 4 8
Memory extension 4GB 8GB 64GB
Network Load Balancing No Yes Yes
Server Clustering No Yes (Max. 2nodes) Yes (Max. 4nodes)
Job Object Job Object API Job Object API Process Control Tool
Winsock Direct No No Yes
Specification of PRIMERGY N800
Windows2000 Server Windows2000 Windows2000
Advanced Server Datacenter Server
32
available wit
Internal Bay
Mounting Additional Memor
A memory board with 16slots is standard equipment and up to 16GB memory can be mounted.
When you add more than 16GB, an additional Memory Board (PG-RB103/PGBRB103) is required.
When using two memory boards in N800, the same memory size must be mounted on each board.
PCI resource area
B
B
B
B
B
A part of address area as below is assi
Operatin
B
stem
Windows®2000 Datacenter Serve
[Maximum Memor
*Up to 32GB Memor
Size:32GB*] 4.0GB ~32.0GB 3.8GB ~4.0GB
can be mounted in one N800.
B
B
B
B
B
ned for PCI resource, cannot be used.
ounte
emory
ze
B
The area for PCI resource
~3.8GB No area for PCI resource
3.8GB ~4.0GB 3.8GB ~4.0GB
- Boot disk can be an external disk. In this case, the disk must be connected to PG-142B RAID Controller.
-
Onboard SCSI Controller
(Ultra2 Wide x 2)
RAID Controller (Standard)
(Ultra160 x 2)
DDS4
(Option)
PRIMERGY S10
(PGUR1BC3)
ChA
Ch0 Ch1
ChB
SCSI Controller
(PG-126)
PRIMERGY S10
(PGUR1BC3)
Install Operating System
Basically, installation should be done by "Installation and Startup Service". So please contact with your local sales representative.
Mountin
devices
- In N800, there are four internal HDD ba
- N800 has one internal 5" bay in chassis for DDS4 (In case of SCSI connection, the DDS4 is available for
dais
-chain connection with HDD
- PRIMERGY S10 (Backup Cabinet) is available if " more then two backup devices" or "backup devices except for DDS4"
are installed.
Configuration Chart
2bays/1ch x 2
r
Connection Matrix
PRIMERGY N800
Connection of internal HDD and internal backup devices
Internal HDD Backup device
Connection Pattern One device is connected Two devices are connected
Configuration SCSI Host Cable Internal HDD In case that Except for Narrow Wide Narrow device
Interface DDS4 is DDS4 device x 2 device x 2 and
connected Wide device
Up to four HDDs can be Onboard SCSI (Ultra2 Wide Bch)
Array Standard Cable(X2) installed Onboard SCSI PRIMERGY S10 (PGUR1BC3)
Configuration Ultra160 RAID Controller (Ch0/1) (Standard 1) 9GB, 10,000rpm (Ach) SCSI Cable (PG-CBLS007/008/009)
equipment) 2) 18GB, 10,000rpm or
3) 18GB, 15,000rpm SCSI Controller (PG-126)
4) 36GB, 10,000rpm PRIMERGY S10 (PGUR1BC3)
SCSI Cable (PG-CBLS001/002/003)
- In case of SCSI configuration (Up to four HDDs can be mounted), internal DDS4 can be connected to ChA of Onboard SCSI by daisy chain.
- when connecting RAID Controller with PRIMERGY S30, or SCSI Controller with Internal HDD, both SCSI Channel of Onboard SCSI Controller must be connected
to Internal HDD.
Maximum
number
Cards Product ID Bus
of cards
Total REMARKS
mounted
SCSI Controller PG-123 PCI64 4 4
10
For external disk array
(Ultra Wide Diff)
SCSI Controller PG-126 PCI64 2
(Ultra2 Wide LVD)
Fibre Channel Controller PG-FC102 PCI64 4
RAID Controller Standard PCI64 1 5 Mounted in PCI slot1
(Ultra160 LVD) Equipment
RAID Controller PG-142B/C PCI64 4
(Ultra160 LVD)
EthernetController PG-188 PCI64 2 4
(1000Base-SX)
EthernetController Standard PCI64 1 Mounted in PCI slot3
(100Base-TX) Equipment
EthernetController PG-185 PCI64 2
(100Base-TX)
Remote Service Board PGURSB101 PCI64 1
For Remote Management
Channel 0
Ultra2 Wide A
Ultra2 Wide B
Onboard
SCSI
For Internal HDD/PRIMERGYS30
Channel 1
For Internal Backup device/Internal HDD
Standard
RAID Controller
For PRIMERGY S10/Internal HDD
For Internal HDD/PRIMERGYS30
Mountable I/O options
N800
Connection Table
PGTN8BHRD2 Rackmount Type 2 x Pentium® lll Xeon™ 700MHz(2MB), Memory:1GB(ECC), HDD:Option
PGTN8BGRD2 Rackmount Type 2 x Pentium® lll Xeon™ 700MHz(1MB), Memory:1GB(ECC), HDD:Option
Rackmount Type
<Items>
CPU Field Upgrade : Go to A
Memory addition : Go to B
Standard Memory Conversion : Go to C
Internal Hard Disk Drive connection Go to D
External Hard Disk Drive connection Go to E
Backup devices Go to F
Others (NIC etc.) Go to G
A:
1
GP5-FG20HT/GP5BFG20HT
Standard : 2CPUs
GP5-FG20GT/GP5BFG20GT
Standard memory : 1GB (256MB-DIMMx4) Max. memory: 32GB Additional Memory - 512MB (256MB-DIMMx2)
B:
2
GP5-RM51J/GP5BRM51J
Additional Memory - 1GB (512MB-DIMMx2)
2
Additional Memory Board GP5-RM1J/GP5BRM1J
PG-RB103/PGBRB103
Additional Memory - 2GB (1GB-DIMMx2)
GP5-RM2J/GP5BRM2J
PGBRU2C
Standard Memory Conversion Kit-4GB (1GB SDRAM-DIMMx4)
PGBRU4C
Max : 4 Hard Disk - 9GB (Ultra160 10,000rpm)
D:
6
(Hot Plug)
Standard RAID Controller PG-HDH91B/PGBHDH91B
(Ultra160/2ch/64MB cache)
Hard Disk - 18GB (Ultra160 10,000rpm)
(Hot Plug)
PG-HDH81B/PGBHDH81B
Hard Disk - 18GB (Ultra160 15,000rpm)
(Hot Plug)
PG-HDH85B/PGBHDH85B
Hard Disk - 36GB (Ultra160 10,000rpm)
(Hot Plug)
PG-HDH61B/PGBHDH61B
Memory
CPU
Internal Hard Disk
Standard RAID Controller Conversion Kit
(Standard RAID to PG-142C)
(Ultra160/2ch/64MB Cache/BBU)
PGB1U42C1
Standard Memory Conversion
Max : 8CPUs CPU Field Upgrade Kit - 74 (Pentium III Xeon 700MHz (2MB) x1)
C:
CPU Field Upgrade Kit - 73 (Pentium III Xeon700MHz (1MB) x1)
Standard Memory Conversion Kit-2GB (512MB SDRAM-DIMMx4)