No part of this manual may be reproduced, stored in a retrieval system, or transmitted, in any form or by any
means, electronic, mechanical, recording, or otherwise, in whole or part, without prior written permission from
Fujitsu Europe Limited.
Fujitsu Europe Limited shall not be liable for any damages or for the loss of any information resulting from the
performance or use of the information contained herein. Your rights to the software are governed by the license
agreement included with any accompanying software. Fujitsu Europe Limited reserves the right to periodically
revise this manual without notice. Product features and specifications described are subject to change without
notice.
Copyright
Fujitsu Europe Limited
Hayes Park Central
Hayes End Road
Hayes, Middlesex, England UB4 8FE
imageRAID and the imageRAID logo are registered trademarks of Fujitsu Europe Limited, Fujitsu is a registered
trademark of Fujitsu Limited.
Other company and product names herein may be trademarks or registered trademarks of their respective
companies.
Agency Notes
WARNING:Drives and controller/adapter cards described in this manual should only be installed in UL-listed and CSA
certified computers that give specific instructions on the installation and removal of accessory cards (refer to your
computer installation manual for proper instructions).
ATTENTION:Les lecteurs et cartes contrôleurs décrits ici ne doivent être montés que sur des ordinateurs homologués (UL et
CSA) et livrés avec des manuels contenant les instructions d’installation et de retrait des accessoires. Reportezvous au manuel d’installation de votre ordinateur.
SERVICE NOTE: Remove the power cables prior to servicing this equipment.
unique 2U design is optimized to fit in the compact space of today’s data centers
rack environments and as a deskside tower system.
At its core is a Fibre Channel IRF-JBOD storage enclosure which supports up to
twelve hot pluggable 1-inch high Fibre Channel disk drives all in a 2U (3.47-inch)
form factor enclosure. Full component redundancy is provided through hot
pluggable Disk I/O cards, Host I/O cards, cooling fan module, and independent
power supplies. RAID functionality is provided through one or two embedded
imageRAID
for Stand-Alone topologies or dual Controllers for Active-Active topologies.
Controller(s). Available as a single Controller configuration designed
Product Identification
Storage EnclosureNumber of ControllersModel of Controller
IRF-JBOD
IRF-1Sxx-xx
IRF-2Sxx-xx
IRF-1Dxx-xx
IRF-2Dxx-xx
0JBOD
1imageRAID
2imageRAID
1imageRAIDXP
2imageRAIDXP
v
About this Manual
The imageRAID IRF-1Sxx-xx/2Sxx-xx is a 12-Bay 3.5" (2U) rackmount storage
solution with one or two 2 Gbit imageRAID FC-to-FC RAID Controllers. Each
controller has 512 MB of cache memory and a battery-backup unit. The storage
enclosure includes dual Host I/O cards, dual Disk I/O cards, eight optical
transceivers, dual power supplies, dual AC power cords, SES card, and a
removable cooling fan module. It also includes configuration software, DB-9 null
modem cable, and a rackmount rail kit. It is upgradeable to either a imageRAID
IRF-1Dxx-xx or 2Dxx-xx model.
The imageRAID IRF-1Dxx-xx/2Dxx-xx is a 12-Bay 3.5" (2U) rackmount storage
solution with one or two 2 Gbit imageRAIDXP FC-to-FC RAID Controllers. Each
controller has 512 MB of cache memory for each processor providing a total of
1 GB of cache memory and a battery-backup unit. The storage enclosure includes
dual Host I/O cards, dual Disk I/O cards, eight optical transceivers, dual power
supplies, dual AC power cords, SES card, and a removable cooling fan module. It
also includes configuration software, DB-9 null modem cable, and a rackmount
rail kit.
This user’s guide is your complete documentation to set up the storage system
hardware, add components, cable the storage system components, replace parts,
and diagnose/repair your system.
vi
Typographical Conventions
For information on software configuration and management, refer to the software
guide included with your system. Your system includes two VT-100 interfaces
(text-based and menu-based), and one GUI interface, StorView.
Typographical Conventions
The following typographical conventions are used in the user’s guide:
■
Menu items are displayed in the format: “Array Configuration menu,
choose
■
Code font
■
Italic code font
■
Italic
■
Key strokes are enclosed in brackets, e.g., <Esc>, <K>, or <Enter>.
View Unused Drives.”
will indicate literal text used in examples.
indicates a replaceable or variable item in code.
text indicates the item that is selected or chosen.
About this Manual
Features
The
imageRAID
requiring the highest performance with uncompromised data reliability, such as
mid-range and enterprise server storage, while maintaining exceptionally high
throughput. The storage system is ideally suited for high bandwidth data intensive
applications, such as electronic commerce, digital video, CAD, seismic research,
digital pre-press, 3-D imaging, and SAN environments.
The following are major features of the imageRAID Series Storage Systems:
■
2 Gb Fibre Channel-to-Fibre Channel storage system enclosure.
■
Hot pluggable disk drives, 12 per enclosure.
■
Hot pluggable cooling fan module and power supplies.
■
SES Enclosure management includes onboard environmental monitoring.
■
Designed to fit standard 19-inch rack enclosures and a deskside tower.
■
Front panel LEDs provide notifications of system component status, and
logical and physical drive status.
■
Support for 16 drives per array and 64 arrays.
Series Storage Systems are designed for mission critical applications
■
RAID Controller uses an Intel XScale 600MHz RISC processor.
■
Transparent failover/failback RAID Controllers in duplex operations.
■
On-board controller-to-host LUN mapping.
■
Mirrored Cache for write-through and write-back operations with a “Save
to Disk” feature for unlimited backup protection.
Operating system independence – no special software or drivers required.
■
Dual 2 Gb/sec (gigabit per second) Fibre Channel ports. Fabric ports are
■
optimized with full duplex operations and auto-negotiate features.
■
Dual 2 Gb/sec disk side ports for high performance, failure resilient paths
to the drives. Full duplex operations optimize disk channels.
■
Capable of sustaining 350 MB/sec sequential RAID 5 reads and up to
100,000 IOPs in active-active configurations.
The base controller installed in the imageRAID has 512 MB cache memory
■
and a total of 1 GB cache memory for the coprocessor models. The
memory is standard PC-100 compatible SDRAM.
■
Support for up to 512 Host LUNs.
Features
vii
About this Manual
Support for RAID levels 0, 1, 5, 10, and 50.
■
Online capacity expansion allowing reconfiguration without interruptions.
■
Dynamic Drive Addressing where the drives do not require hard
■
addressing, allowing for increased flexibility in configurations.
■
Built-in support for drive firmware updates, allowing one or several disk
drives to be updated in parallel.
■
VT-100 interface for configuration and monitoring.
■
StorView module support for a GUI-based interface providing a robust and
easy-to-use configuration and monitoring tool.
Controller firmware updates can be accomplished through a VT-100
■
terminal or StorView Storage Management Software.
■
Host clustering support for maximum data availability.
■
Intel XScale 600MHz RISC co-processor.
■
Dual XOR engines for increased throughput processing (imageRAIDXP).
■
Additional 512 MB cache memory for the coprocessor (imageRAIDXP).
viii
Features
Chapter 1
Getting Started
This chapter provides a description of the enclosure components and its onboard
monitoring systems.
The Components section identifies and gives a complete description of each
major component. The Monitoring section describes the enclosure’s LEDs, and
the manner in which the normal and abnormal conditions are presented.
M
R
A
L
A
T
E
S
E
R
Tower Model
Rack-Mount Model
imageRAID® Series Storage System
R
E
S
E
T
A
L
A
R
M
1
Chapter 1 - Getting Started
At a Glance
The following illustrations show the featured components of the imageRAID
Series Storage System. Familiarize yourself with its components prior to installing
and using the storage system.
Drive Status LEDs
(left column of LEDs)
Drive Activity LEDs
(right column of LEDs)
Power On LED
Channel Status LED
Power Supply Status LED
Fan Status LED
Alarm Reset Button
R
E
SE
T A
LAR
M
2
At a Glance
350-watt hot-pluggable
independent power supplies
Dual in-line 80-CFM hot
swappable cooling fans
Disk I/O Cards
SES Controller Card
Host I/O Cards
imageRAID Controllers
DISK I/O
D
1
T
x
T
x
T
x
D
I
D
S
D
K
1
T
I
x
/
O
T
x
R
S
-
2
T
3
x
2
D
S
E
S
A
A
A
D
D
D
0
1
Component Views
A
/W
P
R
/N
ev-1
08-9-96318001
Fibre D
FAI
LU
FO
R
R
IN
E
H
D
S
A
TA
E
R
TE
DW
LL JU
CT
A
R
M
E
P
ER
S
1 &
2
JP
1
F
A
I
L
F
U
O
R
R
E
IN
H
D
S
A
E
T
R
T
A
E
D
L
C
W
L
T
J
A
U
R
M
E
JP
P
E
2
R
S
1
&
2
J
P
1
A
R
T
P
W
A
RT
O
S
R
E
N
K
S
R
U
C
M
E
O
B
V
N
E
IS
T
R
IO
R
0
O
N
8
L
-1
-9
L
E
-9
R
6
J
P
3
2
2
2
0
0
1
2
H
1
OK
2
2G
H
O
S
S
S
T
B
I/O
P
D
1K
P
R
2
D
1
L
2
M
R
Y
T
10/100
1K
10/100
SP
isk IO
LIT BU
A
D
D
LR
JU
S
C
M
M
PE
O
JP
D
R F
E
O
R
1G
O
A
D
PER
D
JU
ATIO
M
P
N
ER FO
R
A
/W
R
P
/N
e
v
J
0
-
F
P
1
8
ib
1
-
re
9
-9
D
6
is
3
S
1
k
P
IO
8
L
0
IT
0
A
L
1
D
B
R
D
C
U
JP
J
S
U
M
2
M
O
P
D
E
E
R
J
P
F
3
O
R
1
G
O
A
P
D
E
D
R
J
A
U
T
M
IO
P
N
E
R
F
O
R
J
P
2
OK
H
0
H
1
1K
O
K
O
H
K
2
H
0
G
O
O
VR
S
10/100
T
CUR
I/O
1K
PR
D
TNR
R
H
T
1
H
A
RS-232 DTE
0
A
O
VR
10/100
CUR
P
W
H
R
1
H
L
0
D
L
1
L
PR
D
TNR
R
H
T
1
H
A
RS-232 DTE
0
A
P
W
H
R
1
H
L
0
D
L
1
L
A/W REV-1
3
D
1
D
A
0
A
D
0
L
D
1
D
A
0
A
D
0
L
P/N 08-9-96319001
FIBRE HOST IO
PIN 8 - VCC
PIN 7 - VCC
PIN 6 - VCC
PIN 5 - C0CH0CH1_ENB
PIN 4 - C0C1_ENB
J
PIN 3 - HUB F
P
2
PIN 2 W
PIN 1 - 1G/2G
AHOO
SWITCH CONNECTIOONS
AILO
VER
A
/W
P
R
/N
E
F
0
V
IB
8
-1
-9
R
E
-9
H
6
3
O
1
S
9
T
0
0
IO
1
PIN
8
P
I
-N
V
7
C
PI
C
-N
V
6
C
P
I
C
-N
V
5
C
PI
C
-N
C
4
P
0
C
I
-N
H
C
3
P
0
0
C
C
I
-N
H
1
H
_
2
P
1
U
E
_
I
B
N
W
N
E
F
N
B
A
1
S
A
B
H
W
-
IL
O
1
I
O
T
G
O
V
C/2
E
H
G
R
CON
NEC
T
IOO
NS
Chapter 1 - Getting Started
Components
This section provides a description of each of the major components that
comprise the imageRAID Series Storage System.
Front Bezel
The front bezel houses the Status LEDs, Drive LEDs, and alarm reset button. When
removed, the user has access to the disk drives. The front bezel can be installed or
removed without interruption to system activities.
Embedded within the front bezel is the electronic package that provides the
communication with the SES controller. The SES controller manages the signals to
the front panel through a smart interface. Power is applied to the front bezel
through the interface edge connector, where a control circuit monitors the bezel
for proper connection. When the bezel is properly installed and power is applied
to the enclosure, the bezel is immediately energized.
Refer to “Control and Monitoring” on page 18 for details on the monitoring
functions.
Drive LEDs
R
e
s
e
t A
la
r
Status LEDs
Alarm Reset Button
m
Removable Front Bezel
To remove the bezel and gain access to the disk drives, use a Phillips screwdriver
to release both bezel fasteners, then grasp and remove the bezel. The fasteners
rotate one-quarter turn clockwise to lock and counter-clockwise to unlock.
Components
3
Chapter 1 - Getting Started
AC Power
The power system consists of two 350-watt hot-pluggable power supplies, each
with independent AC power cords and cooling fans. This power system provides
the enclosure with “N+1” redundant power. Each power supply has auto-switching
circuitry for use with either 100V or 240V AC systems.
Power On LED
(green)
Fault LED
(amber)
Power Supply
Power is applied to the enclosure by pressing each of the two power supply
On/Off switches to their “On” position. A Power On LED located on each power
supply will be illuminated indicating that AC power has been applied. The front
bezels’ Power On LED will also be illuminated indicating that power has been
applied.
Each power supply also incorporates an amber general Fault LED. If the power
supply is installed and power is not applied to the power supply or the power
supply cooling fan fails, the Fault LED will illuminate, along with an audible alarm.
The front bezels’ Power Supply Status LED will illuminate green when both
power supplies are on and operating normally. If only one power supply is
operational, the Power Supply Status LED will be illuminated amber.
Each power supply has an AC Power Cord Module. The module has a power
cord bale incorporated into the design to secure the power cord once it has been
properly inserted. The bale prevents inadvertent disconnects.
4
AC Power
Chapter 1 - Getting Started
Cooling Fan Module
The cooling system consists of two high-performance (80-CFM) cooling fans
mounted in a single fan module which slides into a bay at the rear of the
enclosure. The design of the fan module provides for an easy-to-install user-
replaceable component in a live environment without interruption of service.
If any one fan should fail, cooling redundancy and efficiency are degraded. The
cooling fans and enclosure temperature are constantly monitored by the SES
processor for fault conditions. In the event of a fault condition the front panel Fan
Status LED will change from a green state to a solid amber state in the case of a fan
failure, or to a blinking amber green state in the case of an over-temperature
condition. In both cases an audible alarm sounds. The SES processor will also
provide notification data to monitoring software, such as StorView.
WARNING:
Do not operate the enclosure for extended periods of time (greater
than 5 minutes) with the cooling fan module removed.
Fan Speed Override Control
Jumpers JP1 (Fan 0)
and JP2 (Fan 1)
Cooling Fan Module
The enclosure has temperature sensors in three different areas, the drive bay, the
imageRAID Controllers, and the power supplies. There are several steps the storage
system performs to prevent component damage due to over temperature
conditions.
Cooling Fan Module
5
Chapter 1 - Getting Started
If the drive bay area reaches a temperature of 50°C (122°F) an audible alarm will
sound, the front panel Fan Status LED will toggle amber green, and the monitoring
software will post a warning message. These notifications give the user a warning
that some condition is causing the enclosure temperature to exceed the preset
value, and an action is required by the user to determine the cause and take
corrective measures. It may be due to a blockage of air flow or a low fan speed.
If any controller reaches a temperature of 65°C (149°F) an audible alarm will
sound, the front panel Fan Status LED will alternate amber and green, and the
monitoring software will post a warning message. If the temperature on any
controller continues to rise and reaches 71°C (159°F), the controller will flush its
cache and shutdown. If it is the only controller (Simplex mode) or the only
remaining controller (surviving controller from a failed over operation) then the
controller will also spin down the disk drives at this temperature.
If any power supply reaches 85°C (185°F) the power supply will shut down.
The SES Controller card has a firmware-based VT-100 interface which provides an
option to manage fan speed. This option provides a whisper mode fan operation
for noise sensitive environments. When enabled (default), and based on a set of
conditions, the software will manage the cooling fans RPM speed to maintain the
enclosure temperature while minimizing noise levels. Refer to “Enclosure Fan
Speed Control” on page 122 for more details on using this option.
6
Cooling Fan Module
A manual override of the fan speed control is available for special circumstance
environments. Referring to the illustration on the preceding page, two jumpers are
provided on the fan module printed circuit board to override the software control
of the fan speeds. This hardware setting routes full power voltage to the fans for
maximum operational speed, which is greater than the maximum speed set by the
automatic software control. This configuration is normally used when fan speed
noises are not an issue, and the ambient operating temperature is at or above 30°C
(86°F), thus ensuring that maximum available cooling is being provided.
The jumpers JP1 and JP2 by default are offset, which enables the automatic fan
speed control. The jumper JP1 controls Fan 0 and JP2 controls Fan 1. Placing the
jumper on both pins for each jumper will override the automatic setting and
configure the fans to maximum power.
SES Controller Card
Chapter 1 - Getting Started
WARNING:
The SES Controller card is NOT HOT SWAPPABLE. You must POWER
DOWN the enclosure prior to removing or inserting this card.
The
SES Controller
card provides the built-in environmental and system status
monitoring. It also houses the switches for setting the drive spin up options. This
card is installed at the rear of the enclosure in the lowest slot below the two Disk
I/O cards.
The SES processors continuously monitor the enclosure for temperature status,
fan status, power supply status, and FC loop status. The processors are
responsible for reporting environmental and system status to the front bezel
LEDs/audible alarms, SES Monitoring software (VT-100), and external monitoring
software such as StorView.
J
P
2
A
R
T
P
W
A
R
O
S
T
R
E
N
S
K
C
U
R
M
O
E
B
V
N
E
I
T
S
R
R
I
O
08
O
N
L
-
-
L
9
E
1
-9
R
6
3
2
2
001
RS-232 Service Port
RS-232
SES
A
A
A
D
S
D
S
B
D
0
P
D
1
P
R
D
2
1
L
2
M
R
Y
T
SES Switches
SES Controller Card
At power up, the SES processors will read the switch settings and execute a
self-test. The cards’ firmware also contains software functions for enclosure
monitoring and management. This firmware is flash upgradeable using the SES
RS-232 Service port located on the card face plate. Refer to “Uploading SES
Controller Card Firmware” on page 119 for more details.
The SES protocol uses the drives installed in slots 1 and 7 to maintain its
communication link. You must install drives in both of these slots to ensure fault
tolerance for the SES communications link.
SES Controller Card
7
Chapter 1 - Getting Started
Below is an illustration depicting the drive slot identification. Drive slot numbers
are not the drive device IDs. Drive slots appearing in gray are the SES
communication slots.
Drive Device ID Settings
Located on the SES Controller card face plate are a set of switches. These
switches will configure the enclosure base Fibre address which configures the
disk drives in each drive slot with a device ID, as well as drive delay spin-up and
remote spin-up options. The default settings is all switches are set to their DOWN
position.
Viewed from the front of the enclosure
Slot 1Slot 4Slot 7Slot 10
Slot 2Slot 5Slot 8Slot 11
Slot 3Slot 6Slot 9Slot 12
Drive Slot Location
S
A
A
A
S
B
D
RS-232
SES
D
0
12
D
1
P
D
P
D
L
1
2
2
R
Y
345678
R
M
T
Up position
Down position
8
Drive Device ID Settings
SES Controller Card Switches
The left three switches (AD0, AD1 and AD2) will configure drive slots with a
series of pre-determined device IDs. Refer to the table below:
A
A
D
Switch
Ranges
IDs 0-11
IDs 16-27
IDs 32-43
IDs 48-59
IDs 64-75
IDs 80-91
IDs 96-107
IDs 112-123
0
Down
DownDown
Down
UpDown
Down
UpUp
Down
Down
UpUpUp
Disk Device ID Switch Settings
A
D
D
1
2
DownUp
Down
UpDown
UpUpDown
UpUp
Chapter 1 - Getting Started
For example, if the setting for switches 1 through 3 are “Down.” the device ID
addresses for the drive slots 1 - 12 would be 0 - 11 respectively.
NOTE:
If a hard address ID conflict occurs during Fibre Channel loop
initialization, the Fibre Channel protocol will dynamically set the drive
IDs. This could cause problems with some software products.
Switches 4, 5, and 6 are not used.
Spin-Up Settings
Switches 7 and 8 control the drive spin-up functions. The switches are directly
attached to all of the drive slot start signals. Switch 7 controls the “Start_1” signal
(Delay Spin-up) and switch 8 controls the “Start_2” signal (Remote Spin-up).
The table below describes the function of each switch.
“DL” Switch 7“RM” Switch 8Drive Spin-up Mode
Down (0)*Down (0)*Drive motor spins up at DC power on.
Down (0)Up (1)Drive motor spins up only on SCSI “start”
commands.
Up (1)Down (0)Drive motor spins up after a delay of 12
(may vary depending on drive type) seconds
times the numeric ID setting of the
associated drive.
Up (1)Up (1)Drive motor will not spin-up.
* Default setting for proper operation.
Spin-Up Settings
9
Chapter 1 - Getting Started
Disk I/O Card
The Disk I/O card is provided for drive channel expansion. By connecting daisy
chained IRF-JBOD enclosures to the Disk I/O cards additional enclosures and
drives can be added to your system. This card’s design incorporates an active
hub, and provides automatic loop regeneration (LRC) and port bypass. The loop
regeneration function will “heal” the FC-AL (Fibre Channel-Arbitrated Loop)
when components become disconnected or faulty.
There are two Disk I/O cards installed at the rear of the enclosure adjacent to the
cooling fan bay. The upper Disk I/O card provides the connection to the “Loop
0” side of the disk drives, and the lower Disk I/O card provides the connection to
the “Loop 1” side of the disk drives.
Each Disk I/O card supports Small Form-Factor Pluggable (SFP) cages to accept
either optical or copper transceivers. They are designed to support NCITS T11
Fibre Channel compliant devices at speeds of 1.0625 Gb per sec or 2.125 Gb per
second. The speed is set through a hardware jumper (JP4) located on the Disk
I/O card. Set the jumper on one pin only or offset for 2Gb mode. If you need to
configure the system for 1Gb mode, position the jumper to both pins. An LED on
the card’s faceplate will illuminate to indicate the 2 Gb mode.
10
Disk I/O Card
FC-AL Loop Port
Loop Status LED
2 Gb/1 Gb Mode LED
P1
DISK I/O
OK
2G
OK
P2
A/W Rev-1
P/N 08-9-96318001
FAILURE DETECT
FOR HARDWARE
INSTALL JUMPERS 1 & 2
1G OPERATION
JP2
ADD JUMPER FOR
JP4
JP1
Disk I/O Card
SPLIT BUS MODE
ADD JUMPER FOR
Fibre Disk IO LRC
JP3
Jumpers JP1 and JP2
must be installed on
both pins .
Jumper JP3 must be offset
or installed on one pin only.
This enables Single Bus mode.
Jumper JP4 must be set
to one pin only for 2Gb mode.
Position it on both pins for
1Gb mode.
Chapter 1 - Getting Started
The jumper, (JP3), must be set to one pin only or offset. This configures the bus
to single bus mode.
The jumpers JP1 and JP2 must be installed on both pins. They provide hardware
failure detect signals.
NOTE:The Disk I/O cards are universal and can be interchanged.
Host I/O Card
The Host I/O card provides the fibre connectivity from the host computer(s) to
the Fibre Channel controller ports. This hot swappable card is designed to
support NCITS T11 Fibre Channel compliant devices at speeds of 1.0625 Gb per
sec or 2.125 Gb per sec. Each card has two SFP cages that house optical or
copper SFP transceivers. They are labeled “H0” and “H1.”
The Host I/O cards are installed at the rear of the enclosure, above the controller
slots. The right Host I/O card provides connectivity to controller’s port 0 (C0P0 and
C1P0) of both controllers, and the left card provides connectivity to controller’s
port 1 (C0P1 and C1P1) of both controllers.
LEDs on the card’s face plate will illuminate to indicate 2 Gb speed mode, host
link status, and activity.
FC Host Ports
Link Status LED
H0
O
K
H1
2
H
G
O
O
S
K
T
I/O
A/W
P/N 08-9-96319003
R
EV-1
E H
OST IO
S
W
I
T
H
C
O
H
S
P
T
C
O
T
S
S
R
P
I
T
L
E
H
I
E
M
O
U
D
N
O
B
D
H
F
E
O
A
O
I
N
S
L
O
/
T
C
O
V
T
H
1
F
E
L
G
0
F
R
R
H
/
D
2
D
0
1
G
U
I
P
L
S
A
0
I
/
L
N
E
P
D
K
N
A
1
I
S
C
A
/
T
E
D
I
N
V
I
S
E
A
/
E
D
N
I
S
A
/
E
D
N
I
S
A
G
/
E
N
N
D
A
G
/
V
N
C
D
C
/
V
C
C
2 Gb/1 Gb Mode LED
FIBR
Host I/O Card
SwitchName
1
HOST SPEED 1G/2G
2
CTRL MODE DIS/ENA
3
HUB FAILOVER DIS/ENA
4
HOST H0H1 LINK DIS/ENA
5
CTRL0 P0P1 LINK DIS/ENA
6
DUAL ACTIVE DIS/ENA
7
GND/VCC
8
GND/VCC
Switch Settings
2 Gb
imageRAID
Enabled
Enabled
Not Used
Enabled
Not Used
Not Used
Function
UP (ON) DOWN (OFF)
1 Gb
Not Used
Disabled
Disabled
Not Used
Disabled
Not Used
Not Used
Host I/O Card
11
Chapter 1 - Getting Started
The following table defines the function of each switch:
SwitchNameFunction
1HOST SPEEDSets the FC Loop speed to 1 Gb or 2 Gb. An LED on the
card will illuminate to indicate 2 Gb mode. The “up”
position sets 2 Gb mode and the “down” position will set
the loop to 1 Gb mode.
2CTRL MODESets the enclosure for a specific controller model. This
switch must be set to the “up” position for the
“imageRAID” Controller. The “down” position is not
applicable.
3HUB FAILOVERThis switch is not used.
4HOST H0H1 LINKThis switch when enabled, “up” position, provides the
link between the Host I/O card H0 and H1 ports. This
switch should be set to the “down” position when Switch
6 is enabled (‘up’ position).
5CTRL0 P0P1 LINKThis switch is not used.
6DUAL ACTIVEThis switch is enabled (up position) when dual
controllers are installed. It is used to enable automatic
internal hub failover during a controller failure.
7GND/VCCThis switch is not used.
8GND/VCCThis switch is not used.
12
SFP Transceiver
Each card contains Port Bypass Circuits (PBC) that allows for hot swapping,
improved signal quality and valid FC signal detection. An onboard Clock
Recovery Units (CRU) is provided to improve the signal quality, determine
whether the input is a valid FC signal, and amplification and jitter removal for
optimum quality signals.
Cabling diagrams are provided in the Installation chapter for each supported
topology. To ensure proper connectivity, failover and failback operations, and
LUN presentation, follow the cabling diagram for your selected topology.
SFP Transceiver
The Host I/O and Disk I/O cards incorporate SFP cages which support optical
hot-swappable Small Form-Factor Pluggable (SFP) transceivers.
The optical SFP transceiver is Class 1 Laser safety compliant and conforms to
Class 1 eye safety standards.
CAUTION:
Do not look into the laser light beam for any extended period of time.
Chapter 1 - Getting Started
Ejector Release Lever
Ejector Release Tab
Ejector Release Lever
SFP Optical Transceiver Models
NOTE:Refer to the Installation chapter for transceiver installation procedures.
Dust covers are provided to protect the transceivers’ optics. It is highly recommend
that the dust covers be installed when a connector is not in place.
A
/W
P
R
/N
e
08
Fibre D
v-1
-9-9FA
IL
F
U
O
R
R
E
H
D
A
T
E
R
A
TE
D
L
L JU
W
C
A
T
R
M
E
PE
RS 1
&
2
JP
1
FA
I
LU
FO
R
R HA
E
IN
D
S
E
TA
R
TE
DW
LL JU
C
T
A
R
M
E
JP
P
E
2
R
S
1 &
D
2
I
S
D
K
1
JP1
T
I
x
T
x
DISK I/O
D1
T
x
T
x
RS-232
S
E
A
/
R
O
T
P
W
AR
O
T
R
N
K
S
R
U
C
M
E
O
B
V
N
E
IS
T
T
R
IO
RO
x
0
N
8
L
-1
-9LE
-9R
6
JP
32
2
200
D
1
2
H
1
T
x
O
K
D2
S
A
A
H
A
OST
D
S
D
S
D
B
0
P
D
1
1
P
K
R
2
D
1
L
2
M
R
Y
T
1
0
/
1
0
0
1
K
1
0
/1
0
0
S
P
6318
isk IO
L
A
IT
D
B
0
D
IN
L
01
U
JU
R
S
S
C
M
MP
O
JP
E
D
R
E
F
O
R
1
G
O
A
D
P
E
D
R
JU
A
TIO
M
P
N
E
R FO
R
A
/W
R
P
/N
ev-1
J
08-9-9
Fibre
P1
D
6318001
isk IO
SP
LIT
AD
LR
BU
D
C
JP
JU
S
M
2
M
O
P
D
E
E
R
F
O
R
1G
O
A
P
D
E
D
R
JU
ATIO
M
PE
N
R
FOR
SE
JP
2
O
H
K
2
0
G
I/O
H
1
1
K
O
K
O
K
2
H
G
O
O
S
V
R
T
1
0
C
/
I/O
1
U
0
0
R
1
K
P
D
R
T
N
R
R
T
RS-232 DTE
O
V
R
1
0
C
/
1
U
0
0
R
P
W
R
P
D
R
T
N
R
R
T
RS-232 DTE
P
W
R
A
3
/W
P
R
/N
E
F
0
V
IB
8
-1
-R
9
E
-
9
H63
O
1
S
9
T
0
IO01
PIN
8
PI
-N
V
7
P
C
JP
I
C
-N
V
3
6
P
C
I
C
-N
V
5
P
C
I
C
-N
C
J
4
P
0
P
I
C
-N
C
2
H
3
P
0
0
I
C
C
-N
H
1
H
2
P
_
U
1
E
I
_
B
N
W
N
E
F
1
A
S
B
N
A
H
W
B
-
IL
O
1
IT
O
G
O
C
V
/2
H
E
G
R
CON
N
ECTIO
ONS
PIN
8
PI
-N
V
7
C
I
C
-N
V
6
C
C
-VC
C
-
C0CH
0C
H
1
_
1
E
_
N
E
N
B
B
I
L
O
VER
H
0
H
1
H
A
0
D
A
1
D
A
0
A
H
1
H
L
0
D
L
1
D
L
0
L
H
1
H
A
0
D
A
1
D
A
0
A
H
1
H
L
0
D
L
1
D
L
0
L
Install the Dust Covers
when the optical transceiver
port is not in use.
Installing and Removing Optical Transceiver Dust Covers
E
V
-16
31
90
01
P
P
IN5
PIN
4
P
I
-N
C
3
P0C
I
-N
H
2
P
U
I
B
N
W
F
A
1
S
A
H
W
-
O
1
IT
G
O
C/2
H
G
CO
NNE
C
TIOO
N
S
A/W
P
R
/N
FIB
0
8
-9R
E
-9 H
O
ST IO
SFP Transceiver
13
Chapter 1 - Getting Started
RAID Controllers
The imageRAID Series Storage System is designed to house one or two hot
pluggable imageRAID Controllers. They are next generation dual port
high-performance 2 Gb/second Fibre Channel-to-Fibre Channel RAID controllers
supporting RAID levels 0, 1, 5, 10, and 50.
There are two models of the
a FC-FC RAID Controller with a single RISC processor. The
imageRAID
Controller. The base
imageRAID
imageRAID
XP model is
model is
the base controller plus a co-processor.
The controllers are
designed for “I/O Intensive” and “Bandwidth Intensive”
applications, providing simplex (stand-alone) and duplex (active-active)
configurations designed for existing and future Fibre Channel topologies.
simplex operations, the controller operates autonomously. In
duplex
In
configurations, the two controllers operate as a pair. In the event one controller
fails, fault tolerance is maintained via hardware failover allowing either controller to
take over the operations of the other controller.
1K
1
10
K
/10
0
Over Current & Partner Controller Status
RS-232 Service Port
Controller Status LEDs
O
V
R
10
C
/100
U
R
P
DRT
R
T
N
R
H1A
H0A
R
D1A
S-232
D0A
DTE
PWR
H1L
H0L
D1L
D0L
14
Fibre Channel-Fibre Channel imageRAID Controller
Each controller has two Fibre Channel ports and two Fibre Channel disk ports for
a “2x2” configuration (dual host-dual drive). In duplex configurations, it can
process up to 80,000 I/O’s per second (IOPS). The active-active pair of RAID
controllers can feed data to SAN nodes at a sustained rate of 320 MB/sec, and
process RAID 5 write operations at 220 MB/sec.
RAID Controllers
Chapter 1 - Getting Started
The core processor of the controller is based on an Intel XScale™ RISC processor
running at 600 MHz. The processor has integrated instructions and data caches
that allow for the most frequent instructions to be executed without having to
access external memory. Coupled with the micro kernel, it processes commands
and I/O’s at extremely high rates.
The processor’s companion chip implements dual independent 64-bit 66MHz PCI
busses. Devices on these busses have independent access to the shared 512 MB
of SDRAM. Also, an integrated XOR accelerator is included for RAID 5 or 50
parity generation.
The imageRAID Controller disk drive interface uses QLogic ISP 2312 dual Fibre
Channel controllers which takes full advantage of the dual fibre loops on each
disk drive. The controller’s host interface also uses QLogic ISP 2312 dual Fibre
Channel controllers which provides two independent ports for host connectivity.
Each port can operate at either 1 Gb/sec or 2 Gb/sec, and the controller will
automatically detect the correct rate. The ports are sometimes referred to as “Host
Loops.”
Located on the controller face plate are Activity, Link and Status LEDs. Refer to
the table below and the illustration on the following page for descriptions for
each LED.
NOTE:The “TXRX-LNK” and “1K-10/100” LEDs are provisions for future options.
RAID Controller Face Plate LEDs
PWR
OVR CUR
PRTNR
TXRX - LNK
1K - 10/100
Indicates power is applied.
Indicates controller over current condition exceeds +5V.
If on, it will indicate that the partner controller has failed.